You are on page 1of 24

FORMULA E JAKARTA 2023

NOTE :

- Anchored by steel anchor / Dynalot into


the ground
CABLE HOLE - Light 400 Lux
15.00
A
PVC CURTAIN PVC CURTAIN

PVC PVC
CURTAIN CURTAIN
ANCHOR ANCHOR

TENT 10X15X4
10.00 TEND 10X15X4
B

PVC PVC
CURTAIN CURTAIN

0.30 0.30
PVC CURTAIN PVC CURTAIN PVC CURTAIN

TENT PLAN 10X15X4

DETAIL ANCHOR

Roof Beam
Roof Beam

Beam Pole

1.82 1.50

5.82
5.82

4.00
4.00

15.00 10.00

VIEW A VIEW B

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

LOGISTIC STORE LOGISTIC STORE LOG.04.01 REFERENCE : SCALE


TENT 10X15X4
NTS
FORMULA E JAKARTA 2023
NOTE :

- Anchored by steel anchor / Dynabolt into


the ground
- Working Lights
25.00 - AC 5 HP : 9 Unit
A - Without Wall

ANCHOR ANCHOR
TENT 10X25X4
10.00 TEND 10X15X4
B

0.30 0.30

TENT PLAN 10X25X4

DETAIL ANCHOR

Roof Beam Roof Beam

Beam Pole

1.82
1.50

5.82 5.82

4.00 4.00

25.00 10.00

VIEW A VIEW B

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

POD ROOF POD ROOF BRD.01.07 REFERENCE : SCALE


TENT 10X25X4
NTS
FORMULA E JAKARTA 2023
NOTE :

- Anchored by steel anchor / Dynabolt into


the ground
- Working Lights
PVC CURTAIN
- Flooring + Standart Carpet Grey Colour
- AC 5 HP : 4 Unit

PVC CURTAIN PVC CURTAIN

TEND 10X10X4 TEND 10X15X4

B 10.00
ANCHOR ANCHOR

PVC CURTAIN PVC CURTAIN

A
10.00 0.30 0.30

TENT PLAN 10X10X4

DETAIL ANCHOR

Roof Beam

Beam Pole

1.50

5.82 5.82

4.00 4.00

10.00 10.00

VIEW A VIEW B

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

FANS STORE 1 FANS STORE 1 FVL.04.01 REFERENCE : SCALE


TENT 10X10X4
NTS
FORMULA E JAKARTA 2023
NOTE :

- Anchored by steel anchor / Dynabolt into


the ground
- Working Lights

B
ANCHOR ANCHOR
TEND 10X5X4 5.00

PVC CURTAIN

A
10.00

0.30 0.30

TENT PLAN 10X5X4

DETAIL ANCHOR

Roof Beam

Beam Pole

1.82
1.50

5.82 5.82

4.00 4.00

5.00
10.00

VIEW A VIEW B

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

ACREDITITATION CENTRE TENT ACREDITITATION CENTRE ACR.01.02 REFERENCE : SCALE


TENT 10X5X4 TENT
NTS
FORMULA E JAKARTA 2023
NOTE :

- Anchored by dynabolt/ballast concrete into the


ground
- Working Lights
- AC 5HP 2 Unit

AC

PVC MEMBRANE PVC MEMBRANE


5.00

5.35

3.45

AC 2.50

5.00

5.00

TENT PLAN 5X5X2.5 VIEW A

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

EMOTION WELCOME DESK WELCOME DESK TENT HOS.01.05 REFERENCE : SCALE


TENT 5X5X2.5
NTS
FORMULA E JAKARTA 2023
NOTE :

- Anchored by dynabolt/ballast concrete


- AC 5 HP : 2 Unit
- Flooring + Standart New Carpet Grey Colour
- Working Lights

PVC CURTAIN

AC

PVC CURTAIN PVC CURTAIN


5.00 5.35

3.45

2.50

AC
PVC CURTAIN
5.00 0.08

5.00

TENT PLAN 5X5X2.5 VIEW A

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

- PODIUM FOH 1 - PODIUM FOH 1 FVL.01.05


- PODIUM FOH 2 - PODIUM FOH 2 FVL.01.06
- POWER OPERATION 1 - POWER OPERATION 1 PWR.04.02 REFERENCE : SCALE
- POWER OPERATION 2 - POWER OPERATION 2 PWR.04.03
TENT 5X5X2.5 NTS
FORMULA E JAKARTA 2023
NOTE :

- Anchored by dynabolt/ballast concrete


- AC 5 HP : 2 Unit
- Flooring + Standart New Carpet Grey Colour
- Working Lights

PVC CURTAIN

AC

PVC CURTAIN PVC CURTAIN


5.00 5.35

3.45

2.50

AC
PVC CURTAIN
5.00 0.08

5.00

TENT PLAN 5X5X2.5 VIEW A

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

- SECURITY TENT - SECURITY TENT SEC.03


- FIRST AID 01 - FIRST AID 01 MED.01.01
- FIRST AID 02 - FIRST AID 02 MED.01.02 REFERENCE : SCALE
- FIRST AID 03 - FIRST AID 03 MED.01.03
NTS
TENT 5X5X2.5
FORMULA E JAKARTA 2023
NOTE :

- Anchored by dynabolt/ballast concrete


- AC 5 HP : 1 Unit
- Working Lights

PVC CURTAIN

PVC CURTAIN PVC CURTAIN


3.00
4.17

3.20

AC 2.50

PVC CURTAIN

3.00

3.00

A
TENT PLAN 3X3X2.5 VIEW A

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

TVC UPS TENT TVC UPS TENT PWR.06 REFERENCE : SCALE


TENT 3X3X2.5
NTS
FORMULA E JAKARTA 2023
NOTE :

- Anchored by dynabolt/ballast concrete


- AC 5 HP : 1 Unit

PVC CURTAIN

PVC CURTAIN PVC CURTAIN


5.00

5.35

3.45

AC 2.50

PVC CURTAIN
5.00
0.08

5.00

TENT PLAN 5X5X2.5 VIEW A

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

BRANDING OFFICE BRA.01.01


BRANDING OFFICE REFERENCE : SCALE
TENT 5X5X2.5
NTS
FORMULA E JAKARTA 2023
NOTE :

- Anchored by dynabolt/ballast concrete


- AC 5 HP : 2 Unit
- Working Lights

PVC CURTAIN

AC

PVC CURTAIN PVC CURTAIN


5.00 5.35

3.45

2.50

AC
PVC CURTAIN
5.00 0.08

5.00

TENT PLAN 5X5X2.5 VIEW A

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

TEAM ORDER STORAGE


TEAM ORDER STORAGE CAT.02 REFERENCE : SCALE
TENT 5X5X2.5
NTS
FORMULA E JAKARTA 2023
NOTE :

- All Structure Anchored by Steel Anchor


/ Dynabolt into The Ground
- Working Lights
- TV STUDIO ( AC 5 HP : 7 Unit )

CABLE HOLE ( 1x200mmx200mm ) CABLE HOLE ( 1x200mmx200mm ) CABLE HOLE ( 1x200mmx200mm )

BRANDING
HARD ACP HARD ACP HARD ACP HARD ACP
(Aluminium Composite Panel) (Aluminium Composite Panel) (Aluminium Composite Panel) (Aluminium Composite Panel)
AC AC AC

HARD ACP HARD ACP


(Aluminium Composite Panel) (Aluminium Composite Panel)
SPT 02.04 SPT 02.03 BRD 05
TEND 10X15X4

C F E AC AC B 10.00
10X20X4 10X15X4 10X5X4
HARD ACP HARD ACP
(Aluminium Composite Panel) (Aluminium Composite Panel)

AC AC

PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN

50.00

TENT PLAN 10X50X4

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

HANKOOK SPT 02.04


OFFICIAL CARS SPT 02.03
HANKOOK + OFFICIAL CARS + TV STUDIO
TV STUDIO BRD 05 REFERENCE : SCALE
TENT 10X50X4
NTS
FORMULA E JAKARTA 2023
NOTE :
Roof Beam
- All Structure Anchored by Steel Anchor
/ Dynabolt into The Ground
- Working Lights
Facade / Branding Facade / Branding Facade / Branding
- TV STUDIO ( AC 5 HP : 7 Unit )
1.50

5.82

4.00

ANCHOR ANCHOR

50.00

VIEW A
Roof Beam

1.82

0.30 0.30

5.82

4.00

DETAIL ANCHOR
50.00

VIEW D

Roof Beam Roof Beam

Branding
Branding Beam Pole
Branding

1.50
Facade / Branding

5.82
5.82

4.00
4.00

10.00
10.00

VIEW B VIEW E

Roof Beam
Roof Beam
Beam Pole
Branding Beam Pole
Branding

5.82
5.82
4.00
4.00

10.00
10.00

VIEW C VIEW F

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

HANKOOK SPT 02.04


OFFICIAL CARS SPT 02.03
HANKOOK + OFFICIAL CARS + TV STUDIO
TV STUDIO BRD 05 REFERENCE : SCALE
TENT 10X50X4
NTS
FORMULA E JAKARTA 2023
NOTE :
D
- All Structure Anchored by Steel Anchor /
Dynabolt into The Ground
CABLE HOLE ( 1x200mmx200mm ) - Working Lights
- SPARES TENT ( AC 5 HP : 7 Unit )
BRANDING
HARD ACP HARD ACP HARD ACP - ABB GARAGE ( AC 5 HP : 4 Unit )
(Aluminium Composite Panel) (Aluminium Composite Panel) (Aluminium Composite Panel)
- T&C SHADES AREA ( Misty Fan : 3 Unit & Astrotuff
AC AC AC AC AC
10X5 m )

HARD ACP PVC CURTAIN


(Aluminium Composite Panel) ANCHOR ANCHOR
SPT 02.05 SPT 02.07 CAT 01.99
TEND 10X15X4

C AC F AC E 10.00 B
10X15X4 10X10X4 10X5X4
HARD ACP
(Aluminium Composite Panel)

PVC CURTAIN
AC AC AC AC
0.30 0.30

PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN
BRANDING

30.00

DETAIL ANCHOR
A

TENT PLAN 10X50X4

Roof Beam Roof Beam Roof Beam

Beam Pole Beam Pole


Branding
Branding

Facade / Branding Facade / Branding Facade / Branding 1.50 1.50

5.82 5.82 5.82

4.00 4.00 4.00


AC AC

30.00 10.00 10.00

VIEW A VIEW B VIEW E


Roof Beam Roof Beam Roof Beam

Beam Pole Beam Pole


Branding Branding

1.82

5.82 5.82 5.82

4.00 4.00 4.00


AC AC AC

30.00 10.00 10.00

VIEW D VIEW C VIEW F

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

FE SPARES SPT 02.05


ABB SPT 02.07
FE SPARES + ABB + T&C SHADER
T&C SHADER CAT 01.99 REFERENCE : SCALE
TENT 10X30X4
NTS
FORMULA E JAKARTA 2023
D NOTE :

- All Structure Anchored by Steel Anchor /


Dynabolt into The Ground
- Working Lights
- WAE ( AC 5 HP : 4 Unit )
PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN

AC AC

HARD ACP HARD ACP


(Aluminium Composite Panel) (Aluminium Composite Panel)
SPT 02.06 TEC 04.02 TEC 04.01
ANCHOR ANCHOR
TEND 10X15X4

C E F 10.00 B
10X10X4 10X10X4 10X15X4
HARD ACP
(Aluminium Composite Panel)

AC AC

HARD ACP HARD ACP HARD ACP 0.30 0.30


(Aluminium Composite Panel) (Aluminium Composite Panel) (Aluminium Composite Panel)

CABLE HOLE CABLE HOLE CABLE HOLE


35.00

A
DETAIL ANCHOR

TENT PLAN 10X35X4

Roof Beam Roof Beam Roof Beam

Beam Pole Beam Pole

1.82

5.82 5.82 5.82

4.00 4.00 4.00


AC AC

35.00 10.00 10.00


VIEW E
VIEW A VIEW B
Roof Beam Roof Beam Roof Beam

Beam Pole Beam Pole

1.82

5.82 5.82 5.82

4.00 4.00 4.00

35.00 10.00 10.00

VIEW D VIEW C VIEW F

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

WAE SPT 02.06


TATA TEC 04.02
WAE + TATA + AL Kamel
AL KAMEL TEC 04.01 REFERENCE : SCALE
TENT 10X35X4
NTS
FORMULA E JAKARTA 2023
NOTE :

- All Structure Anchored by Steel Anchor / Dynabolt


into The Ground
- Working Lights
- AC 7 HP : 60 Unit
KITCHEN : 10 Unit
DINING AREA : 60 Unit
- FLOORING
- CARPET
C KITCHEN : NON - SLIP
DINING AREA : Standart Carpet New Grey

PVC CURTAIN PVC CURTAIN PVC CURTAIN GLASS PANEL GLASS PANEL GLASS PANEL GLASS PANEL GLASS PANEL

ABS WALL

GLASS PANEL
PVC CURTAIN 5.00

ABS WALL

PVC CURTAIN PVC CURTAIN 5.00


B
ANCHOR ANCHOR
D KITCHEN
DINNING AREA 20.00
ABS WALL 20X10
GLASS PANEL
PVC CURTAIN 5.00

ABS WALL

0.30 0.30
GLASS PANEL
PVC CURTAIN PVC CURTAIN 5.00

PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN PVC CURTAIN DETAIL ANCHOR

5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00

50.00

TENT PLAN 20X50X4

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

T & C DINING AREA T&C DINING AREA CAT.01.01 REFERENCE : SCALE


T & C KITCHEN
TENT 10X35X4 T&C KITCHEN CAT.01.04
NTS
FORMULA E JAKARTA 2023
NOTE :

- All Structure Anchored by Steel Anchor / Dynabolt


into The Ground
- Working Lights
- AC 7 HP : 60 Unit
KITCHEN : 10 Unit
DINING AREA : 60 Unit
- FLOORING
- CARPET
KITCHEN : NON - SLIP
DINING AREA : Standart Carpet New Grey

3.25

4.00

50.00

VIEW A

3.25

4.00

50.00

VIEW C

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

T & C DINING AREA T&C DINING AREA CAT.01.01 REFERENCE : SCALE


T & C KITCHEN
TENT 10X35X4 T&C KITCHEN CAT.01.04
NTS
FORMULA E JAKARTA 2023
NOTE :

- All Structure Anchored by Steel Anchor / Dynabolt


into The Ground
- Working Lights
- AC 7 HP : 60 Unit
KITCHEN : 10 Unit
DINING AREA : 60 Unit
- FLOORING
- CARPET
KITCHEN : NON - SLIP
Roof Beam DINING AREA : Standart Carpet New Grey
Beam Pole

3.25

4.00

20.00

VIEW B

Roof Beam

Beam Pole

3.25

4.00

20.00

VIEW D

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

T & C DINING AREA T&C DINING AREA CAT.01.01 REFERENCE : SCALE


T & C KITCHEN
TENT 10X35X4 T&C KITCHEN CAT.01.04
NTS
FORMULA E JAKARTA 2023
NOTE :
HAND RAIL
C 5X5 SHADES
DECKING - BEC Kitchen Tent Structure Use Ballast
Concrete
- Boss Emotion Club Tent Structure Use Ballast
Concrete From FE Properties
- Height Platform 100cm-110cm From Ground
- Main Entrance Ramps Boss Emotion Club Use
Glass Railing
- Entrance Ramps Kitchen BEC Railing by Steel
- Stairs For Committee Acces 3 Unit
- AC For BEC Kitchen 5 HP : 10 Unit
- Carpet Non slip For BEC Kitchen 15x25 m
- Tent Connecting 5x5m From FE Properties
- Platform Structure 7x50m + 30x50m + 5x5m +
15X25m

5.00

18.00 3.00

B
BOSS - EMOTION

D 30X50M

KITCHEN
15X25

2.50

5.30 0.30

TENT PLAN EMOTION 30X50X4 2.50

TENT PLAN KITCHEN 15X25X4


3.00 9.50

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

BOSS EMOTION BOSS EMOTION HOS.01.02


TENT 30X50X4
BOSS KITCHEN HOS.01.07 REFERENCE : SCALE
BOSS KITCHEN
TENT 15X25X4 NTS
FORMULA E JAKARTA 2023
NOTE :

- BEC Kitchen Tent Structure Use Ballast


Concrete
- Boss Emotion Club Tent Structure Use Ballast
Concrete From FE Properties
- Height Platform 100cm-110cm From Ground
- Main Entrance Ramps Boss Emotion Club Use
Glass Railing
- Entrance Ramps Kitchen BEC Railing by Steel
- Stairs For Committee Acces 3 Unit
- AC For BEC Kitchen 5 HP : 10 Unit
- Carpet Non slip For BEC Kitchen 15x25 m
- Tent Connecting 5x5m From FE Properties
4.87 - Platform Structure 7x50m + 30x50m + 5x5m +
15X25m

10.38

4.00 3.00
18.00

1.50
0.60

5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
Ringlock
Ballast 1.2x0.6x0.75

55.00

VIEW A

4.87

10.38

4.00 3.00
18.00

1.50

5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00

Ringlock Ballast 1.2x0.6x0.75

50.00

VIEW C

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

BOSS EMOTION BOSS EMOTION HOS.01.02 REFERENCE : SCALE


TENT 30X50X4
NTS
FORMULA E JAKARTA 2023
NOTE :

- BEC Kitchen Tent Structure Use Ballast


Concrete
- Boss Emotion Club Tent Structure Use Ballast
Concrete From FE Properties
- Height Platform 100cm-110cm From Ground
- Main Entrance Ramps Boss Emotion Club Use
Glass Railing
- Entrance Ramps Kitchen BEC Railing by Steel
- Stairs For Committee Acces 3 Unit
Beam Pole
- AC For BEC Kitchen 5 HP : 10 Unit
Roof Beam
- Carpet Non slip For BEC Kitchen 15x25 m
15.89 - Tent Connecting 5x5m From FE Properties
- Platform Structure 7x50m + 30x50m + 5x5m +
5x5 Shades
Hard PVC Wall
15X25m
8.87 5.00
7.02
Hand Rail
5.35
4.00

1.00

1.50

5.00 5.00 5.00 5.00 5.00 5.00 7.00


Ballast 1.2x0.6x0.75 Ringlock

37.00

VIEW B

Beam Pole
Roof Beam

15.89

5x5 Shades
Hard PVC Wall

8.87
5.00

7.02

Hand Rail 5.35

4.00

1.00

1.50

7.00 5.00 5.00 5.00 5.00 5.00 5.00

Ringlock Ballast 1.2x0.6x0.75

37.00

VIEW D

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

BOSS EMOTION BOSS EMOTION HOS.01.02 REFERENCE : SCALE


TENT 30X50X4
NTS
FORMULA E JAKARTA 2023
NOTE :

- BEC Kitchen Tent Structure Use Ballast


Concrete
- Boss Emotion Club Tent Structure Use Ballast
Concrete From FE Properties
- Height Platform 100cm-110cm From Ground
- Main Entrance Ramps Boss Emotion Club Use
C -
Glass Railing
Entrance Ramps Kitchen BEC Railing by Steel
- Stairs For Committee Acces 3 Unit
- AC For BEC Kitchen 5 HP : 10 Unit
- Carpet Non slip For BEC Kitchen 15x25 m
25.00 - Tent Connecting 5x5m From FE Properties
- Platform Structure 7x50m + 30x50m + 5x5m +
15X25m

KITCHEN
D 15X25
15.00 B

2.50

5.30 0.30

2.50

3.00 12.29
15.29

A
TENT PLAN KITCHEN 15X25X4

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

BOSS KITCHEN BOSS KITCHEN HOS.01.07 REFERENCE : SCALE


TENT 15X25X4
NTS
FORMULA E JAKARTA 2023
NOTE :

- BEC Kitchen Tent Structure Use Ballast


Concrete
- Boss Emotion Club Tent Structure Use Ballast
Concrete From FE Properties
- Height Platform 100cm-110cm From Ground
Roof Beam - Main Entrance Ramps Boss Emotion Club Use
Beam Pole
Glass Railing
7.93 - Entrance Ramps Kitchen BEC Railing by Steel
- Stairs For Committee Acces 3 Unit
2.40 2.40 - AC For BEC Kitchen 5 HP : 10 Unit
- Carpet Non slip For BEC Kitchen 15x25 m
- Tent Connecting 5x5m From FE Properties
- Platform Structure 7x50m + 30x50m + 5x5m +
7.90
4.00 5.00 4.00 15X25m
12.31

1.50 1.50

2.50 5.00 5.00 5.00


5.00 5.00 5.00 5.00 5.00
Ringlock
Ballast 1.2x0.6x0.75
25.00 Ringlock Ballast 1.2x0.6x0.75
15.00

VIEW A VIEW B

Roof Beam

Beam Pole
7.93

2.40 2.40

7.90
4.00 5.00 4.00

1.50 1.50

5.00 5.00 5.00


5.00 5.00 5.00 5.00 5.00
Ringlock
Ringlock Ballast 1.2x0.6x0.75
Ballast 1.2x0.6x0.75
25.00 15.00

VIEW C VIEW D

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

BOSS KITCHEN BOSS KITCHEN HOS.01.07 REFERENCE : SCALE


TENT 15X25X4
NTS
FORMULA E JAKARTA 2023

2.00

CARPET GREY

8.00

2.00

0.20

8.00

0.20

2.00

0.20

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

PRESSCON PLATFORM PRESSCON PLATFORM PRS.01.07


REFERENCE : SCALE
8 X 2 X 0.2 M
NTS
FORMULA E JAKARTA 2023

CARPET GREY

6.00

1.00

0.20

6.00

0.20

1.00

0.20

AREA Comment : SPACE NAME SPACE CODE DRAWING NUMBER : REVISION

CAMERA PLATFORM CAMERA PLATFORM PRS.01.08


REFERENCE : SCALE
6 X 1 X 0.2 M
NTS