COP 1838+ / 1838HD+ / 1838AW+ Ver. F

Worksite: ___________________________________________________________________

Drill rig type: ___________ Serial No.: ___________ Manufacturing No.: ___________ Feed No.: __

COP: ___________ Serial No.: AVO _____________ Rotation motor size: _____________

Make sure the hydraulic oil have reached normal working temperature before adjusting the base settings.
The rock drill pressures in this document refers to the pressure at the rock drill intakes. The hydraulic
pressure at the operator panel is usually 5-10 bar above the pressure at the rock drill.

Max. Base settings Actual settings

Intake accumulator (HP)


charged to collaring pressure minus 40 bar 100 bar 90 bar . . . . . . . . . . bar

Damper accumulator (D) charged to 25 bar 25 bar . . . . . . . . . . bar

Return accumulator (LP)


atmospheric pressure (ATM) inside when plug is fitted ATM ATM . . . . . . . . . . bar

Damper idle pressure 35 bar . . . . . . . . . . bar


Damper idle pressure (measured at operators panel) - . . . . . . . . . . bar
(damper flow 9 l/min)

Lubricating air pressure at rock drill 3 bar > 2.5 bar . . . . . . . . . . bar

ECL-lubricant pulses/minute (pulses/min) 25 > 20 pulses/min . . . . pulses/min

Percussion pressure during:


Collaring 130 bar . . . . . . . . . . bar
Drilling 230 bar 200 bar . . . . . . . . . . bar

Damper pressure at operators panel during:


Collaring 40 - 50 bar . . . . . . . . . . bar
Drilling 150 bar 50 - 100 bar . . . . . . . . . . bar

Rotational speed of drill bit (will vary depending on local


conditions and rock type):
Bit diameter = 45 mm Approx. 210 rpm . . . . . . . . . rpm
Bit diameter = 51 mm Approx. 210 rpm . . . . . . . . . rpm
Bit diameter = 89 mm Approx. 120 rpm . . . . . . . . . rpm
Bit diameter = 102 mm (reaming from 51 mm) Approx. 170 rpm . . . . . . . . . rpm

(Frequency approx. 55 Hz at 200 bar percussion pressure)

Other drilling rig settings:


Idle feed pressure (over the entire feed length) Max 15 - 35 bar . . . . . . . . . . bar
Water flushing pressure 25 bar - . . . . . . . . . . bar
RPCF-pressure, above idling rotation pressure 15 - 30 bar . . . . . . . . . . bar
Anti-jamming pressure, above RPCF pressure 15 - 30 bar . . . . . . . . . . bar

Settings carried out by

……………………………………………… …………………..
Service engineer in charge No. Date