Pre-Qualification Ventilation Fans

Index:

 Company Profile
 Governmental documents

 Quality And Management Assurance Certificates


 Products Certificates

 Projects list-KSA
 Approvals
 Products catalogue
Company Profile
COMPANY www.moroojp.com
PROFILE
2021

Company Profile www.moroojp.com


1
GET TO KNOW
A L M O R O O J PA L A C E C O N T R A C T I N G

Company Profile www.moroojp.com


ABOUT US

ALMOROOJ PALACE Est is a installation and commissioning


well-established Organization of wide rang of the equipment.
in the king dom of saudi Arabia, ALMOROOJ PALACE Est in the
Located in Riyadh, specialized in partener and the sole agent
pump, ecology units,water and of an international reputable
waste water treatment bussiness, word wide companies that pro-
power genetation and firesupres- vides innovation technologies
sion sys. ALMOROOJ PALACE pro- across the entire water world
vide solutions and full technical Also with all the mentioned
support in all our products.With us scopes we have construction sec-
you will find consultancy, supply, tion and specialest in landscaping

Company Profile www.moroojp.com


Our
Company
Vision &
Mission

VISION
• Providing an integrated solution in electro-mechanical field

MISSION
• To cover the needs of the clients in the field of water, waste-
water, power generation and in the envirosystems and safty
through professional specialised teams in supply, installation, oper-
ation and maintenance beside providing professional consultancy.

Values
• Seeking to achieve quality in all our works.
• Encouraging continuous learning.
• Promoting fairness and integrity in our work with our clients.
• Working together as one to achieve our goals.
• Encouraging our employees to maximize their creative and innovation
potentials.
• Fulfilling the obligations, we have towards our clients and employees.

Strength
• Increase the sources of income
• Developing sales in the field of industrial sector.
• Continuously developing the work process and achieving
the clients’ satisfaction.
• Achieving the financial targets.

Company Profile www.moroojp.com


• ALMOROOJ PALACE Est is a well-established Organization in the
Kingdom of Saudi Arabia, located in Riyadh, specialized in mechanical
and electrical bussiness. ALMOROOJ PALACE Est provide solutions and
full technical supports in water, wastewater, power generation and in
the envirosystems and safty. With us you will find the consultancy , sup-
ply, installation and commissioning of a wide range of the equipment..
• ALMOROOJ PALACE Est is the partner and the sole agent
of an international reputable world wide companies that pro-
vides innovative technologies across the entire water world.

The products range of our equipment

1. Water solution as
• muncipal waste water treatment Equipment.
• Industrial waste water treatment Equipment.
• reverse osmosis plant & water softening equipments.
• water & firefighting Pumps.
2. Ecology systems
3. Ventaltion systems
4. Suppression System (novec , co2 , foam, ansul R102
5. Grease Trap

• ALMOROOJ PALACE Est in cooperation with it’s partners is


participating and playing a vital rule in the construction and upgrading
of many sewerage and industrial waste water treatment plants for the
goverment and for the private sectors in the Kindom of Saudi Arabia..

Company Profile www.moroojp.com


Our Partner

Polet Group Water

Sempa Pumps-Turkey
OUR WATTS
PARTNER
Rydair-Span
ANSUL

Company Profile www.moroojp.com


1
AQUALINE

We work through the Pollet Water Group for sustainable solutions and continuous

network with 5 manufacturers and 18 improvement, and recruitment of talented

distribution companies & 1 engineering employees. The Pollet Group is part of

office. We draw on over 1000 employees, Group J. Pollet, which also owns a chain of

an extensive distribution network with ten retail stores in franchise with Carrefour.

daily shipments, 24/7 delivery, and export The Pollet Water Group is an expert when

capability worldwide. We invest in product it comes to water treatment. We supply

development by building environmentally standard solutions as well as made-

friendly solutions, personalised products to-measure concepts. To maintain our

and collaboration with top brands. We offer technological lead, we continuously invest in

dedicated customer service with technical our manufacturers. The Pollet Water Group

support, water analyses, calculations, has production facilities in Germany, France,

costings, commissioning and installation. Turkey, Belgium and the UK. We analyse,

We focus on water treatment companies, design and engineer solutions for your

OEMs, DIY, public authorities and sanitary water facilities. We attach great importance

wholesale. Join our mission. Make water count. to an environmentally and technologically

The Pollet Water Group is part of the Pollet responsible selection of resources. Our

Group, which is active in three sectors: water R&D teams constantly search for new and

treatment, swimming pools, and health sustainable solutions. Our manufacturing

care. Within these three areas, the Group has capability gives our partners a competitive

companies across Europe, the Middle East advantage through highly reliable energy-

and Africa. We work closely with dedicated and water-saving solutions with optimised

partners all over the world. Our programme of return on investment. Our manufacturers

continuous expansion is based on intensive export worldwide and have global presence.

cooperation with our customers, our striving

Company Profile www.moroojp.com


Our Companies
• Herco
• euraquaUK.
• Cappers.
• Es;i.
• Delta.

Products range of equipment for waste


and industrial wastewater treatment
• RQ’S
• Filtration systems
• ULTRA FILTRATION SYSTEM
• POINT OF USE DEVICES.
• BOOSTER UNITS
• BLOEDOWN SYSTEM
• WATER STORGE TANKS
• DESTILLO MIXED BED SOLUTIONS.

For detailed products range, please visit our web-site:


www.aqualine-me.com

Company Profile www.moroojp.com


2
SEMPA

Sempa Limited Company was founded Emphasis on Professional work in the pump

under the nameOJ MSM in 1972 in Konya industry, our company has been modernized

Region (Turkey) to meet the needs of themachinestoproducehighqualityproducts

surface water pumps Depending on the At the same time, has provided to balance the

vexical shaft surface water retreat in 1989 market price without compromising quality

staxed the production oJ deep well pumps All manufactured pumps have TSE

Developmenl in the construclion sector Quality and iso goo1:z000 Qualily

lowards to 2000s, Sempa expanded 1he Management System Certificate-In 2013

product range to meet the needs of sector we have moved in the new own factory

and became the leader oJ 1he pump sector which has 10-000 m2 close ,20 000 m2 open

Company Profile www.moroojp.com


Products range of equipment for water pumps
From SEMPA Factory: (Origin :Turkey)

• Single and multistage • Submersible sewage


centrifugal pumps.Chiller pumps.
System • Submersible deep well
• In line centrifugal pumps. pumps.
• Spilt case centrifugal • Booster pumps
pumps. • Fire Fighting Pumps.
• Self-priming centrifugal
pumps.
• Vertical multistage centrif-
ugal pumps.

Company Profile www.moroojp.com


3
RydAir

Contaminated air is drawn by the blower pass into the collector plates section made up

(external) through a washable metal mesh of equally spaced parallel plates. Each alternate

pre-filter which traps large dust particles. plate is charged with the same polarity as the

The remaining particles, some as small as particles, which repel, while the interleaving

0.01micron, pass through a strong electrical field plates are grounded, which attract and collect

(ionizing section) where the particulates receive the contaminants. The contaminants are

an electrical charge. The charged particles then held on these plates until they are washed off.

Products range of equipment for


Ecology system

• Electrostatic Air Cleaners


• AirTreatment Products for Kitchen ex-
haust offices and factories

Company Profile www.moroojp.com


5
ANSUL

Commercial kitchen areas are a significant fire The new technical standard helps harmonies

risk to many buildings, including restaurants, legislation across the industry by creating

hotels and schools with café or canteen facilities. consistent hazard classifications, performance

At Johnson Controls, we strive to develop testing and service and maintenance

innovative products to meet specific guidelines. The standard moves the restaurant

customer needs and protect lives, property industry toward more effective commercial

and businesses. ANSUL® brand restaurant kitchen fire protection helping to better

fire suppression systems have been designed safeguard valued people, property and business

to rapidly detect and combat kitchen fires.

Products range of equipment for


kitchen protection

• Fire suppression systems > Aerosol


• FM200
• Novec 1230.
• Co2 systems
• kitchen Hood
• Foam systems

Company Profile www.moroojp.com


6
WATTS

Watts hydro-mechanical grease, facilities. Our interceptors separate

oil, and commercial sediment effluents and solids from wastewater

interceptors protect downstream at the source, collecting and storing the

piping and wastewater treatment unwantedsubstancesforlaterremoval.

Products range of equipment for


drainage system

Company Profile www.moroojp.com


Quality And Management Assurance Certificates
ACCREDITED LABORATORY
The laboratory of

Maico Gulf LLC


Al Ghail Industrial Park Plot No. P299 & 301
P.O. Box 9014 - Al Ghail Ras Al Khaimah, UAE

is accredited with AMCA International as being


qualified to conduct tests in accordance with

AMCA Standard 210


Figures 12, 15
AMCA Standard 300
Figures 1, 2, 3

Laboratory Director

EXECUTIVE DIRECTOR

Feb 23, 2016 Feb 23, 2025


ORIGINAL ACCREDITATION ACCREDITATION EXPIRATION
DATE DATE

AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC.


30 WEST UNIVERSITY DRIVE, ARLINGTON HEIGHTS, ILLINOIS 60004-1893 U.S.A.
Products Certificates
9/20/21, 5:27 PM Certificate review

)/(

EN


...Aboud Salem Jaham

Certificate of Conformity
for Regulated Products
Certificate of conformity
for regulated products
We (……………..UL Middle East FZ LLC………………………………………………….. ....... ) office number
(......04539......) are bearing full responsibility for the product described below is conforms to the
conformity assessment procedure conducting the relevant technical regulations and standards which
mentioned during this certificate.

Certificate  26514-045-21-481393  07/08/2022 Expire  07/08/2023


Issue Date
Number Date

 Certificate of conformity for Commercial  1010950396


Certificate Type
regulated products Registration No

Establishment
 Riyadh - Al-Malaz District
Address

Product and Manufacturer Data

Model Name  TA-HP Trade Mark Dynair

Product Name  DIRECT DRIVEN AXIAL FAN

Product  DIRECT DRIVEN AXIAL FAN


Description

Country of origin  United Arab Emirates

HS Code  841459009999

Technical  GCC Technical Regulation for Low Voltage Electrical Equipment and Applications
Regulation

Manufacturer  MAICO GULF LLC


name

Product test data

Report number  

Report Date  

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfw… 1/2
9/20/21, 5:27 PM Certificate review

Decision of confidence  Product Approved


assessment

CB Organization Office
CB Organization Office
Responsabile Manager 09/20/2021 04:27
Stamp
signature

 details Model number details

)back (/ContactOfficer/MyRequests/HRRequests

Terms and Conditions (/Home/Terms)


| Contact us (/home/ContactUs)
| Authority Portal

)(http://www.saso.gov.sa/ar/contactus/Pages/default.aspx

Develop and run


Under supervision


Saudi Standards, Metrology and Quality Organization  2021

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfw… 2/2
9/20/21, 5:27 PM Certificate review

)/(

EN


...Aboud Salem Jaham

Certificate of Conformity
for Regulated Products
Certificate of conformity
for regulated products
We (……………..UL Middle East FZ LLC………………………………………………….. ....... ) office number
(......04539......) are bearing full responsibility for the product described below is conforms to the
conformity assessment procedure conducting the relevant technical regulations and standards which
mentioned during this certificate.

Certificate  26514-045-21-481396  07/08/2022 Expire  07/08/2023


Issue Date
Number Date

 Certificate of conformity for Commercial  1010950396


Certificate Type
regulated products Registration No

Establishment
 Riyadh - Al-Malaz District
Address

Product and Manufacturer Data

Model Name  TA-HT Trade Mark Dynair

Product Name  INDUSTRIAL FANS

Product  INDUSTRIAL FANS- AXIAL FAN


Description

Country of origin  United Arab Emirates

HS Code  841459009999

Technical  GCC Technical Regulation for Low Voltage Electrical Equipment and Applications
Regulation

Manufacturer  MAICO GULF LLC


name

Product test data

Report number  

Report Date  

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfwel… 1/2
9/20/21, 5:27 PM Certificate review

Decision of confidence  Product Approved


assessment

CB Organization Office
CB Organization Office
Responsabile Manager 09/20/2021 04:27
Stamp
signature

 details Model number details

)back (/ContactOfficer/MyRequests/HRRequests

Terms and Conditions (/Home/Terms)


| Contact us (/home/ContactUs)
| Authority Portal

)(http://www.saso.gov.sa/ar/contactus/Pages/default.aspx

Develop and run


Under supervision


Saudi Standards, Metrology and Quality Organization  2021

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfwel… 2/2
9/20/21, 5:27 PM Certificate review

)/(

EN


...Aboud Salem Jaham

Certificate of Conformity
for Regulated Products
Certificate of conformity
for regulated products
We (………………SGS Gulf Limited (Dubai)……………………………………….. ........ ) office number
(......03932......) are bearing full responsability for the product described below is conforms to the
conformity assessment procedure Conduct the relevant technical regulations and standards which
mentioned during this certificate.

Certificate  26514-039-21-484883  07/13/2022 Expire  07/13/2023


Issue Date
Number Date

 Certificate of conformity for Commercial  1010950396


Certificate Type
regulated products Registration No

Establishment
 Riyadh - Al-Malaz District
Address

Product and Manufacturer Data

Model Name  Box-T Trade Mark Dynair

Product Name  Belt Driven Centrifugal Fan

Product  
Description

Country of origin  United Arab Emirates

HS Code  841459009999

Technical  GCC Technical Regulation for Low Voltage Electrical Equipment and Applications
Regulation

Manufacturer  MAICO GULF LLC


name

Product test data

Report number  SAPC/2021/016396

Report Date  07/13/2021

Decision of confidence  Product Approved


assessment
https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfzk… 1/2
9/20/21, 5:27 PM Certificate review

CB Organization Office
CB Organization Office
Responsabile Manager 09/20/2021 04:27
Stamp
signature

 details Model number details

)back (/ContactOfficer/MyRequests/HRRequests

Terms and Conditions (/Home/Terms)


| Contact us (/home/ContactUs)
| Authority Portal

)(http://www.saso.gov.sa/ar/contactus/Pages/default.aspx

Develop and run


Under supervision


Saudi Standards, Metrology and Quality Organization  2021

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfzk… 2/2
9/20/21, 5:26 PM ‫استعراض الشهادة‬

)/(

EN 
...‫
عبود سالم جهام‬

‫شهادة مطابقة للمنتجات‬


‫الخاضعة للوائح‬
Certificate of conformity
for regulated products
We (....................SGS Gulf Limited (Dubai).............................. ) office number (......03932......) are
bearing full responsability for the product described below is conforms to the conformity assessment
procedure
Conduct the relevant technical regulations and standards which mentioned during this
certificate.

Certificate  26514-039-21-484885  13/07/2022 Expire  13/07/2023


Issue Date
Number Date

 Certificate of conformity for Commercial  1010950396


Certificate Type
regulated products Registration No

Establishment
 ‫ حي الملز‬- ‫الرياض‬
Address

Product and Manufacturer Data

Model Name  Box-T HT Trade Mark Dynair

Product Name  Belt Driven Centrifugal Fan

Product  
Description

Country of origin  United Arab Emirates

HS Code  841459009999

Technical  GCC Technical Regulation for Low Voltage Electrical Equipment and Appliances
Regulation

Manufacturer  MAICO GULF LLC


name

Product test data

Report number  SAPC/2021/016396

Report Date  13/07/2021

Decision of confomity  Product Approved


assessment

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfy4… 1/2
9/20/21, 5:26 PM ‫استعراض الشهادة‬

CB Organization Office
CB Organization Office
Responsabile Manager 20/09/2021 04:26
Stamp
signature

 ‫تفاصيل‬ ‫تفاصيل أرقام الموديالت‬

)ContactOfficer/MyRequests/HRRequests/( ‫عودة‬

‫)
|
بوابة الهيئة‬home/ContactUs/( ‫)
|
اتصل بنا‬Home/Terms/( ‫أحكام وشروط‬

)http://www.saso.gov.sa/ar/contactus/Pages/default.aspx(


تحت اشراف
تطوير و تشغيل‬

2021  ‫الهيئة السعودية للمواصفات والمقاييس والجودة‬

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfy4… 2/2
9/20/21, 5:26 PM Certificate review

)/(

EN


...Aboud Salem Jaham

Certificate of Conformity
for Regulated Products
Certificate of conformity
for regulated products
We (………………SGS Gulf Limited (Dubai)……………………………………….. ........ ) office number
(......03932......) are bearing full responsability for the product described below is conforms to the
conformity assessment procedure Conduct the relevant technical regulations and standards which
mentioned during this certificate.

Certificate  26514-039-21-484886  07/13/2022 Expire  07/13/2023


Issue Date
Number Date

 Certificate of conformity for Commercial  1010950396


Certificate Type
regulated products Registration No

Establishment
 Riyadh - Al-Malaz District
Address

Product and Manufacturer Data

Model Name  TMF Trade Mark Dynair

Product Name  Circular type direct driven centrifugal fan.

Product  
Description

Country of origin  United Arab Emirates

HS Code  841459009999

Technical  GCC Technical Regulation for Low Voltage Electrical Equipment and Applications
Regulation

Manufacturer  MAICO GULF LLC


name

Product test data

Report number  SAPC/2021/016396

Report Date  07/13/2021

Decision of confidence  Product Approved


assessment
https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2BbfyQ… 1/2
9/20/21, 5:26 PM Certificate review

CB Organization Office
CB Organization Office
Responsabile Manager 09/20/2021 04:26
Stamp
signature

 details Model number details

)back (/ContactOfficer/MyRequests/HRRequests

Terms and Conditions (/Home/Terms)


| Contact us (/home/ContactUs)
| Authority Portal

)(http://www.saso.gov.sa/ar/contactus/Pages/default.aspx

Develop and run


Under supervision


Saudi Standards, Metrology and Quality Organization  2021

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2BbfyQ… 2/2
9/20/21, 5:25 PM ‫استعراض الشهادة‬

)/(

EN 
...‫
عبود سالم جهام‬

‫شهادة مطابقة للمنتجات‬


‫الخاضعة للوائح‬
Certificate of conformity
for regulated products
We (....................SGS Gulf Limited (Dubai).............................. ) office number (......03932......) are
bearing full responsability for the product described below is conforms to the conformity assessment
procedure
Conduct the relevant technical regulations and standards which mentioned during this
certificate.

Certificate  26514-039-21-484888  13/07/2022 Expire  13/07/2023


Issue Date
Number Date

 Certificate of conformity for Commercial  1010950396


Certificate Type
regulated products Registration No

Establishment
 ‫ حي الملز‬- ‫الرياض‬
Address

Product and Manufacturer Data

Model Name  PRL-TC Trade Mark Dynair

Product Name  Belt driven centrifugal fan

Product  
Description

Country of origin  United Arab Emirates

HS Code  841459009999

Technical  GCC Technical Regulation for Low Voltage Electrical Equipment and Appliances
Regulation

Manufacturer  MAICO GULF LLC


name

Product test data

Report number  SAPC/2021/016396

Report Date  13/07/2021

Decision of confomity  Product Approved


assessment

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfw9j… 1/2
9/20/21, 5:25 PM ‫استعراض الشهادة‬

CB Organization Office
CB Organization Office
Responsabile Manager 20/09/2021 04:25
Stamp
signature

 ‫تفاصيل‬ ‫تفاصيل أرقام الموديالت‬

)ContactOfficer/MyRequests/HRRequests/( ‫عودة‬

‫)
|
بوابة الهيئة‬home/ContactUs/( ‫)
|
اتصل بنا‬Home/Terms/( ‫أحكام وشروط‬

)http://www.saso.gov.sa/ar/contactus/Pages/default.aspx(


تحت اشراف
تطوير و تشغيل‬

2021  ‫الهيئة السعودية للمواصفات والمقاييس والجودة‬

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfw9j… 2/2
9/20/21, 5:25 PM ‫استعراض الشهادة‬

)/(

EN


...Aboud Salem Jaham

Certificate of Conformity
for Regulated Products
Certificate of conformity
for regulated products
We (………………SGS Gulf Limited (Dubai)……………………………………….. ........ ) office number
(......03932......) are bearing full responsability for the product described below is conforms to the
conformity assessment procedure Conduct the relevant technical regulations and standards which
mentioned during this certificate.

Certificate  26514-039-21-484887  13/07/2022 Expire  13/07/2023


Issue Date
Number Date

 Certificate of conformity for Commercial  1010950396


Certificate Type
regulated products Registration No

Establishment
 ‫ حي الملز‬- ‫الرياض‬
Address

Product and Manufacturer Data

Model Name  QCM Trade Mark Dynair

Product Name  Plate mounted axial fans

Product  
Description

Country of origin  Italy

HS Code  841459009999

Technical  GCC Technical Regulation for Low Voltage Electrical Equipment and Appliances
Regulation

Manufacturer  Maico Italia S.p.A


name

Product test data

Report number  SAPC/2021/016396

Report Date  13/07/2021

Decision of confomity  Product Approved


assessment

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2BbfwQ… 1/2
9/20/21, 5:25 PM ‫استعراض الشهادة‬

CB Organization Office
CB Organization Office
Responsabile Manager 20/09/2021 04:25
Stamp
signature

 ‫تفاصيل‬ ‫تفاصيل أرقام الموديالت‬

)ContactOfficer/MyRequests/HRRequests/( ‫عودة‬

‫)
|
بوابة الهيئة‬home/ContactUs/( ‫)
|
اتصل بنا‬Home/Terms/( ‫أحكام وشروط‬

)http://www.saso.gov.sa/ar/contactus/Pages/default.aspx(


تحت اشراف
تطوير و تشغيل‬

2021  ‫الهيئة السعودية للمواصفات والمقاييس والجودة‬

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2BbfwQ… 2/2
9/20/21, 5:24 PM ‫استعراض الشهادة‬

)/(

EN 
...‫
عبود سالم جهام‬

‫شهادة مطابقة للمنتجات‬


‫الخاضعة للوائح‬
Certificate of conformity
for regulated products
We (....................SGS Gulf Limited (Dubai).............................. ) office number (......03932......) are
bearing full responsability for the product described below is conforms to the conformity assessment
procedure
Conduct the relevant technical regulations and standards which mentioned during this
certificate.

Certificate  26514-039-21-484890  13/07/2022 Expire  13/07/2023


Issue Date
Number Date

 Certificate of conformity for Commercial  1010950396


Certificate Type
regulated products Registration No

Establishment
 ‫ حي الملز‬- ‫الرياض‬
Address

Product and Manufacturer Data

Model Name  DRF Trade Mark Dynair

Product Name  Direct Driven Centrifugal Roof Fan.

Product  
Description

Country of origin  United Arab Emirates

HS Code  841459009999

Technical  GCC Technical Regulation for Low Voltage Electrical Equipment and Appliances
Regulation

Manufacturer  MAICO GULF LLC


name

Product test data

Report number  SAPC/2021/016396

Report Date  13/07/2021

Decision of confomity  Product Approved


assessment

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfw… 1/2
9/20/21, 5:24 PM ‫استعراض الشهادة‬

CB Organization Office
CB Organization Office
Responsabile Manager 20/09/2021 04:24
Stamp
signature

 ‫تفاصيل‬ ‫تفاصيل أرقام الموديالت‬

)ContactOfficer/MyRequests/HRRequests/( ‫عودة‬

‫)
|
بوابة الهيئة‬home/ContactUs/( ‫)
|
اتصل بنا‬Home/Terms/( ‫أحكام وشروط‬

)http://www.saso.gov.sa/ar/contactus/Pages/default.aspx(


تحت اشراف
تطوير و تشغيل‬

2021  ‫الهيئة السعودية للمواصفات والمقاييس والجودة‬

https://saber.sa/ContactOfficer/HRRequest/HRCoCProductCertificate?query=2N4HkkyWHYCZQKC7Da6v18bw4Y%2FbLeVVtqqNNRG%2Bbfw… 2/2
LGAI Technological Center, S.A. (APPLUS)
Campus UAB - Ronda de la Font del Carme s/n
08193 Bellaterra (Barcelona)
T +34 93 567 20 00
F +34 93 567 20 01
www.applus.com

CERTIFICATE
No. 0370-CPR-1366
No.
CERTIFICATE OF CONSTANCY OF PERFORMANCE
In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the
Construction Products Regulation or CPR), this certificate applies to the construction product:

SMOKE AND HEAT CONTROL SYSTEMS. PART 3: SPECIFICATION FOR POWERED SMOKE AND HEAT
CONTROL VENTILATORS (FANS)
TRADEMARK: DYNAIR MODELS: CC-JC 250 HT F300 (60) & CC-JC 300 HT F300 (60)

Place on the market under the name of:

MAICO GULF LLC


AL GHAIL INDUSTRIAL PARK, PLOT No 299 & 301
P.O. BOX 9014
RAS AL KHAIMAH (UAE)

And produced in the manufacturing plant:

AL GHAIL INDUSTRIAL PARK, PLOT No 299 & 301


P.O. BOX 9014
RAS AL KHAIMAH (UAE)

This certificate attests that all provisions concerning the assessment and verification of constancy of performance
described in Annex ZA of the standard

EN 12101-3:2015

under system 1 are applied and that the product fulfils all the prescribed requirements set out above.

This certificate was first issued on 20th July 2012 and will remain valid as long as the test methods and/or factory
production control requirements included in the harmonised standard, used to assess the performance of the
declared characteristics, do not change, and the product, and the manufacturing conditions in the plant are not
modified significantly. It is confirmed on 29th June 2018.

The monitoring assessment will be done before July 2019

Bellaterra, 29th June 2018

Xavier Ruiz Peña


Managing Director, Product Conformity B.U.

This document is not valid without its technical annex, whose number coincides with the number of certificate
Page 1 / 2
LGAI TECHNOLOGICAL CENTER, S.A. CIF: A-63207492
LGAI Technological Center, S.A. (APPLUS)
Campus UAB - Ronda de la Font del Carme s/n
08193 Bellaterra (Barcelona)
T +34 93 567 20 00
F +34 93 567 20 01
www.applus.com

CERTIFICATE
No. 0370-CPR-2563
No.
CERTIFICATE OF CONSTANCY OF PERFORMANCE
In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the
Construction Products Regulation or CPR), this certificate applies to the construction product:

SMOKE AND HEAT CONTROL SYSTEMS. PART 3: SPECIFICATION FOR POWERED SMOKE AND HEAT
CONTROL VENTILATORS (FANS)
TRADEMARK: DYNAIR, MODEL: CC JD 312 F400 (120)

Place on the market under the name of:

MAICO GULF LLC


AL GHAIL INDUSTRIAL PARK, PLOT No 299 & 301
P.O. BOX 9014
RAS AL KHAIMAH (UAE)

And produced in the manufacturing plant:

AL GHAIL INDUSTRIAL PARK, PLOT No 299 & 301


P.O. BOX 9014
RAS AL KHAIMAH (UAE)

This certificate attests that all provisions concerning the assessment and verification of constancy of performance
described in Annex ZA of the standard

EN 12101-3:2015

under system 1 are applied and that the product fulfils all the prescribed requirements set out above.

This certificate was first issued on 18th March 2016 and will remain valid as long as the test methods and/or factory
production control requirements included in the harmonised standard, used to assess the performance of the
declared characteristics, do not change, and the product, and the manufacturing conditions in the plant are not
modified significantly. It is confirmed on 29th June 2018.

The monitoring assessment will be done before July 2019

Bellaterra, 29th June 2018

Xavier Ruiz Peña


Managing Director, Product Conformity B.U.

This document is not valid without its technical annex, whose number coincides with the number of certificate
Page 1 / 2

LGAI TECHNOLOGICAL CENTER, S.A. CIF: A-63207492


LGAI Technological Center, S.A. (APPLUS)
Campus UAB - Ronda de la Font del Carme s/n
08193 Bellaterra (Barcelona)
T +34 93 567 20 00
F +34 93 567 20 01
www.applus.com

CERTIFICATE
No. 0370-CPR-2196
No.
CERTIFICATE OF CONSTANCY OF PERFORMANCE
In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the
Construction Products Regulation or CPR), this certificate applies to the construction product:

SMOKE AND HEAT CONTROL SYSTEMS. PART 2: NATURAL SMOKE AND HEAT EXHAUST VENTILATORS
RANGE: DYNAVENT DDSV

Place on the market under the name of:

MAICO GULF LLC


AL GHAIL INDUSTRIAL PARK, PLOT No 299 & 301
P.O. BOX 9014
RAS AL KHAIMAH (UAE)

And produced in the manufacturing plant:

AL GHAIL INDUSTRIAL PARK, PLOT No 299 & 301


P.O. BOX 9014
RAS AL KHAIMAH (UAE)

This certificate attests that all provisions concerning the assessment and verification of constancy of performance
described in Annex ZA of the standard

EN 12101-2:2003

under system 1 are applied and that the product fulfils all the prescribed requirements set out above.

This certificate was first issued on 31st July 2015 and will remain valid as long as the test methods and/or factory
production control requirements included in the harmonised standard, used to assess the performance of the
declared characteristics, do not change, and the product, and the manufacturing conditions in the plant are not
modified significantly. It is confirmed on 29th June 2018.

The monitoring assessment will be done before July 2019

Bellaterra, 29th June 2018

Xavier Ruiz Peña


Managing Director, Product Conformity B.U.

This document is not valid without its technical annex, whose number coincides with the number of certificate

Page 1 / 3
LGAI TECHNOLOGICAL CENTER, S.A. CIF: A-63207492
LGAI Technological Center, S.A. (APPLUS)
Campus UAB - Ronda de la Font del Carme s/n
08193 Bellaterra (Barcelona)
T +34 93 567 20 00
F +34 93 567 20 01
www.applus.com

CERTIFICATE
No. 0370-CPR-2769
No.
CERTIFICATE OF CONSTANCY OF PERFORMANCE
In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the
Construction Products Regulation or CPR), this certificate applies to the construction product:

SMOKE AND HEAT CONTROL SYSTEMS. PART 2: NATURAL SMOKE AND HEAT EXHAUST VENTILATORS
RANGE: DYNAVENT - DSV

Place on the market under the name of:

MAICO GULF LLC


AL GHAIL INDUSTRIAL PARK, PLOT No 299 & 301
P.O. BOX 9014
RAS AL KHAIMAH (UAE)

And produced in the manufacturing plant:

AL GHAIL INDUSTRIAL PARK, PLOT No 299 & 301


P.O. BOX 9014
RAS AL KHAIMAH (UAE)

This certificate attests that all provisions concerning the assessment and verification of constancy of performance
described in Annex ZA of the standard

EN 12101-2:2003

under system 1 are applied and that the product fulfils all the prescribed requirements set out above.

This certificate was first issued on 7th July 2017 and will remain valid as long as the test methods and/or factory
production control requirements included in the harmonised standard, used to assess the performance of the
declared characteristics, do not change, and the product, and the manufacturing conditions in the plant are not
modified significantly. It is confirmed on 29th June 2018.

The monitoring assessment will be done before July 2019

Bellaterra, 29th June 2018

Xavier Ruiz Peña


Managing Director, Product Conformity B.U.

This document is not valid without its technical annex, whose number coincides with the number of certificate

Page 1 / 3
LGAI TECHNOLOGICAL CENTER, S.A. CIF: A-63207492
Appendix to the License Agreement To Use The AMCA
Certified Ratings Program Seal
Appendix No. : 31
In accordance with the License Agreement issued on March 18, 2009 by Air Movement and Control Association International, Inc.,
Maico Gulf LLC is hereby authorized to use the AMCA Certified Ratings Seal on the specific air movement and control devices
listed below. Such use shall in all respects be governed by and subject to the provisions of said License Agreement.

Centrifugal Fans

Product Line Catalog ID

DCF Exhaust Ceiling Fan - 50/60 Hz Blowdyn 2.0 V2.21, July 2021

Size Model No Size Model No Size Model No


150 DCF-10-24SL 130 DCF-10-21S 184 DCF -15-27SL
184 DCF- 15-27SL 150 DCF-10-24SH 184 DCF-15-32S
184 DFC-15-32S 184 DCF-15-27SH

* License to Bear The AMCA Seal For Sound and Air Performance.

Please verify current certification status in the AMCA International Directory of Licensed Products located at www.amca.org.
Granted on August 10, 2021

Unit of Measure: mm

Nazme Mohsina Revised :


Technical Director
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

This license appendix may not be reproduced, except in full, without the written approval of AMCA International, Inc.
NL PL IT EN
Bij twijfel over de vertaling wordt alleen de tekst in het Italiaans W przypadku jakichkolwiek wątpliwości dotyczących tłumaczenia, Per qualsiasi dubbio sulla traduzione solo il testo in italiano sarà In case of incorrect or doubtful translation, only the Italian text
als geldig beschouwd (Vertaling
������������������������������������������
van de oorspronkelijke gebruik- jedynie tekst w języku włoski uznaje się za obowiązujący ritenuto valido (Istruzioni originali). applies (Translation of the original instructions).
saanwijzing). Tłumaczenie instrukcji oryginalnych).

EU-Conformiteitsverklaring Deklaracja zgodności UE Dichiarazione di conformità UE EC Declaration of Conformity

Product model/Product: ECOLINE 100 - ECOLINE 120 - Model produktu/produkt: ECOLINE 100 - ECOLINE 120 -
ECOLINE 150 ECOLINE 150 Modello di apparecchio/Prodotto: ECOLINE 100 - Product model/product: ECOLINE 100 - ECOLINE 120 -
ECOLINE 120 - ECOLINE 150
Naam en adres van de fabrikant: Nazwa i adres producenta: ECOLINE 150
Maico Italia S.p.A. Maico Italia S.p.A. Name and address of the manufacturer:
Via Maestri del Lavoro, 12 Via Maestri del Lavoro, 12 Nome e indirizzo del fabbricante: Maico Italia S.p.A.
I-25017 Lonato d/Garda BS I-25017 Lonato d/Garda BS Maico Italia S.p.A. Via Maestri del Lavoro, 12
no.02835680170 (BS) no.02835680170 (BS) Via Maestri del Lavoro, 12 I-25017 Lonato d/Garda BS
I-25017 Lonato d/Garda BS no.02835680170 (BS)
Deze conformiteitsverklaring wordt verstrekt onder volledige Niniejsza deklaracja zgodności wydana zostaje na wyłączną no.02835680170 (BS)
verantwoordelijkheid van de fabrikant. odpowiedzialność producenta. This declaration of conformity is issued under the sole
La presente dichiarazione di conformità è rilasciata sotto la re- responsibility of the manufacturer.
Voorwerp van de verklaring: Przedmiot deklaracji: sponsabilità esclusiva del fabbricante.
HELICOÏDALE WAND-, PLAFOND- EN/OF RAAMVENTILA- WENTYLATOR WYCIĄGOWY OSIOWY DO MONTAŻU Object of the declaration:
TOR ŚCIENNEGO, SUFITOWEGO I/LUB W OKNIE Oggetto della dichiarazione: WALL- AND/OR CEILING-MOUNTED AND/OR WINDOW-FIT-
ASPIRATORE ELICOIDALE DA PARETE E/O SOFFITTO E/O TED AXIAL EXTRACTOR FAN
Het hierboven beschreven voorwerp is in overeenstemming Wymieniony powyżej przedmiot niniejszej deklaracji jest zgodny VETRO
met de desbetreffende harmonisatiewetgeving van de Unie: z odnośnymi wymaganiami unijnego prawodawstwa harmoniza- The object of the declaration described above is in con-
cyjnego: L’oggetto della dichiarazione di cui sopra è conforme alle perti- formity with the relevant Union harmonisation legislation:
Richtlijnen 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU nenti normativa di armonizzazione dell’Unione:
(Rohs-2), 2009/125/EC (ErP). Dyrektywy 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU (Rohs-2),
Geharmoniseerde technische normen vastgesteld: (Rohs-2), 2009/125/EC (ErP). Direttive 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU 2009/125/EC (ErP) Directives.
EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006+A1 Zharmonizowane normy techniczne przyjęte: (Rohs-2), 2009/125/EC (ErP). The following harmonized standards have been used:
3: 2008+A14:2010+A15:2011, EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006+A1 Norme tecniche armonizzate adottate: EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006+A1
EN60335-2-80:2003+A1:2004+A2:2009, 3: 2008+A14:2010+A15:2011, EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006+A1 3: 2008+A14:2010+A15:2011,
EN62233:2008, EN60335-2-80:2003+A1:2004+A2:2009, 3: 2008+A14:2010+A15:2011, EN60335-2-80:2003+A1:2004+A2:2009,
EN55014-1:2006+A1:2009+A2:2011, EN62233:2008, EN60335-2-80:2003+A1:2004+A2:2009, EN62233:2008,
EN55014-2:1997+A1:2001+A2:2008, EN55014-1:2006+A1:2009+A2:2011, EN62233:2008, EN55014-1:2006+A1:2009+A2:2011,
EN61000-3-2:2006+A1:2009+A2:2009, EN55014-2:1997+A1:2001+A2:2008, EN55014-1:2006+A1:2009+A2:2011, EN55014-2:1997+A1:2001+A2:2008,
EN61000-3-3:2013, EN61000-3-2:2006+A1:2009+A2:2009, EN55014-2:1997+A1:2001+A2:2008, EN61000-3-2:2006+A1:2009+A2:2009,
EN61000-6-3:2007+A1:2011, EN61000-3-3:2013, EN61000-3-2:2006+A1:2009+A2:2009, EN61000-3-3:2013,
EN50581:2012, EN61000-6-3:2007+A1:2011, EN61000-3-3:2013, EN61000-6-3:2007+A1:2011,
EN5801:2008, EN50581:2012, EN61000-6-3:2007+A1:2011, EN50581:2012,
Reg. 1253/2014. EN5801:2008, EN50581:2012, EN5801:2008,
Reg. 1253/2014. EN5801:2008, Reg. 1253/2014.
Het product, zoals door ons ontworpen, gebouwd en op de markt Reg. 1253/2014.
gebracht, in overeenstemming is met de gezondheids- en veilig- Niniejszym oświadczamy, że opisywane w tej deklaracji urzą- The product, ��������������������������������������������������
as designed, constructed and sold by us, is in ac-
heidseisen van de hierboven vermelde EU-richtlijnen, mits deze dzenie, zaprojektowane, skonstruowane i sprzedawane przez Il prodotto, così come da noi progettato, costruito e commercia- cordance with the relevant safety and health requirements of
volgens de instructiehandleiding geïnstalleerd en onderhouden naszą firmę, jest zgodne z wymogami bezpieczeństwa i higieny lizzato, è conforme ai requisiti di salute e sicurezza delle Diret- the EC Council Directives mentioned above, provided that it is
wordt. Indien er wijzigingen aan de machine aangebracht wor- pracy zamieszczonych niżej dyrektywy UE, pod warunkiem, że tive sopra riportate, a condizione che venga installato e mante- installed and maintained according to the instructions manual.
den is deze verklaring niet geldig meer. zostanie zainstalowane i będzie poddawane konserwacji zgod- nuto in accordo al manuale di istruzioni. Qualora la macchina If alterations are made to the machinery, this declaration will no
nie z instrukcją obsługi. W przypadku naruszenia lub wprowa- venga manomessa o modificata la presente dichiarazione non longer apply.
Ondertekend voor en namens Maico Italia SpA. dzenia zmian do maszyny niniejsza deklaracja zgodności traci potrà ritenersi valida.
ważność. Signed for and on behalf of Maico Italia S.p.A.
Lonato d/G, 20/04/2016 Firmato a nome e per conto di Maico Italia S.p.A.
Podpisano w imieniu Maico Italia S.p.A. Lonato d/G, 20/04/2016
Virgilio Montorio, Algemeen Directeur Lonato d/G, 20/04/2016
Lonato d/G, 20/04/2016 Virgilio Montorio, General Manager
Virgilio Montorio, Direttore Generale
Virgilio Montorio, Dyrektor Główny
FR DE ES PT
En cas de doute sur la traduction, seul le texte en italien est In Zweifelsfällen bezüglich der Übersetzung hat der italienische Para cualquier duda referente a la traducción solamente se con- Para qualquer dúvida sobre a tradução somente o texto em Ital-
valable (Traduction de la notice originale). Text vorrang (Übersetzung der Originalanweisungen). siderará válido el texto en italiano (Traducción
���������������������������
de las instruc- iano será válido (Tradução das instruções originais).
ciones originales).

Déclaration de Conformité CE EG-Konformitätserklärung Declaración UE de Conformidad Declaração UE de Conformidade

Modèle de produit/produit: ECOLINE 100 - ECOLINE 120 - Produktmodell/Produkt: ECOLINE 100 - ECOLINE 120 - Modelo de producto/producto: ECOLINE 100 - ECOLINE 120 - Modelo do produto/produto: ECOLINE 100 - ECOLINE 120 -
ECOLINE 150 ECOLINE 150 ECOLINE 150 ECOLINE 150

Nom et adresse du fabricant: Name und Anschrift des Herstellers: Nombre y dirección del fabricante: Nome e endereço do fabricante:
Maico Italia S.p.A. Maico Italia S.p.A. Maico Italia S.p.A. Maico Italia S.p.A.
Via Maestri del Lavoro, 12 Via Maestri del Lavoro, 12 Via Maestri del Lavoro, 12 Via Maestri del Lavoro, 12
I-25017 Lonato d/Garda BS I-25017 Lonato d/Garda BS I-25017 Lonato d/Garda BS I-25017 Lonato d/Garda BS
no.02835680170 (BS) no.02835680170 (BS) no.02835680170 (BS) no.02835680170 (BS)

La présente déclaration de conformité est établie sous la Die alleinige Verantwortung für die Ausstellung dieser Konformi- La presente declaración de conformidad se expide bajo la A presente declaração de conformidade é emitida sob a exclu-
seule responsabilité du fabricant. tätserklärung trägt der Hersteller. exclusiva responsabilidad del fabricante. siva responsabilidade do fabricante.

Objet de la déclaration: Gegenstand der Erklärung: Objeto de la declaración: Objeto da declaração:


EXTRACTEUR HÉLICOÏDAL MURAL ET/OU AU PLAFOND AXIALVENTILATOR FÜR WAND-, DECKEN-UND/ODER FEN- EXTRACTOR HELICOIDAL MURAL Y/O DE TEJADO Y/O ASPIRADOR HELICOIDAL DE PAREDE E/OU TECTO E/OU
ET/OU POUR VITRE STEREINBAU VENTANA JANELA

L’objet de la déclaration décrit ci-dessus est conforme à la Der oben beschriebene Gegenstand der Erklärung erfüllt die El objeto de la declaración descrita anteriormente es conforme O objeto da declaração acima descrito está em conformidade
législation d’harmonisation de l’Union applicable: einschlägigen Harmonisierungsrechtsvorschriften der Union: con la legislación de armonización pertinente de la Unión: com a legislação de harmonização da União aplicável:

Directives 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU (Rohs-2), Directivas 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU Directivas 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU
(Rohs-2), 2009/125/EC (ErP). 2009/125/EC (ErP) Richtlinien. (Rohs-2), 2009/125/EC (ErP). (Rohs-2), 2009/125/EC (ErP).
Normes harmonisées utilisées: Harmonisierter technischer Standards angenommen: Normas técnicas armonizadas adoptadas: Normas técnicas harmonizadas adoptadas:
EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006+A1 EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006+A1 EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006+A1 EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006+A1
3: 2008+A14:2010+A15:2011, 3: 2008+A14:2010+A15:2011, 3: 2008+A14:2010+A15:2011, 3: 2008+A14:2010+A15:2011,
EN60335-2-80:2003+A1:2004+A2:2009, EN60335-2-80:2003+A1:2004+A2:2009, EN60335-2-80:2003+A1:2004+A2:2009, EN60335-2-80:2003+A1:2004+A2:2009,
EN62233:2008, EN62233:2008, EN62233:2008, EN62233:2008,
EN55014-1:2006+A1:2009+A2:2011, EN55014-1:2006+A1:2009+A2:2011, EN55014-1:2006+A1:2009+A2:2011, EN55014-1:2006+A1:2009+A2:2011,
EN55014-2:1997+A1:2001+A2:2008, EN55014-2:1997+A1:2001+A2:2008, EN55014-2:1997+A1:2001+A2:2008, EN55014-2:1997+A1:2001+A2:2008,
EN61000-3-2:2006+A1:2009+A2:2009, EN61000-3-2:2006+A1:2009+A2:2009, EN61000-3-2:2006+A1:2009+A2:2009, EN61000-3-2:2006+A1:2009+A2:2009,
EN61000-3-3:2013, EN61000-3-3:2013, EN61000-3-3:2013, EN61000-3-3:2013,
EN61000-6-3:2007+A1:2011, EN61000-6-3:2007+A1:2011, EN61000-6-3:2007+A1:2011, EN61000-6-3:2007+A1:2011,
EN50581:2012, EN50581:2012, EN50581:2012, EN50581:2012,
EN5801:2008, EN5801:2008, EN5801:2008, EN5801:2008,
Reg. 1253/2014. Reg. 1253/2014. Reg. 1253/2014. Reg. 1253/2014.

Le produit, tel
��������������������������������������������������
que nous l’avons conçu, fabriqué et commercia- Das Produkt, so wie sie von uns konzipiert, gebaut und in den La máquina cumple, tal y como la hemos diseñado, fabricado O produto, assim como por nós projectado, fabricado e comer-
lisé, est conforme aux exigences de santé et de sécurité des Verkehr gebracht wurde, den Gesundheits- und Sicherheitsan- y comercializado, con los requisitos de salud y seguridad de cializado, é conforme aos requisitos de saúde e segurança das
directives EU susmentionnées, à condition qu’il soit installé et forderungen der oben aufgeführten EU-Richtlinien entspricht, las directivas EU que se recogen aquí arriba, con tal de que se directivas EU acima descritas, sob a condição que seja ins-
entretenu conformément au manuel d’instructions. En cas d’al- soweit sie der Betriebsanleitung entsprechend installiert und ge- instale y mantenga de acuerdo con el manual de instrucciones. talado e conservado em acordo com o manual de instruções.
térations ou de modifications apportées à la machine, la pré- wartet wird. Jede an der Maschine vorgenommene, nicht autori- La presente declaración ha de considerarse no válida en el caso Sempre que a máquina seja violada ou modificada, a presente
sente déclaration perd sa validité. sierte Änderung führt zum Gültigkeitsverfall dieser Erklärung. de que la máquina se altere o modifique. declaração não poderá ser considerada válida.

Signé par et au nom de Maico Italia S.p.A. Unterzeichnet für und im Namen von Maico Italia S.p.A. Firmado en nombre de Maico Italia S.p.A. Assinado por e em nome de Maico Italia S.p.A.

Lonato d/G, 20/04/2016 Lonato d/G, 20/04/2016 Lonato d/G, 20/04/2016 Lonato d/G, 20/04/2016

Virgilio Montorio, Directeur général Virgilio Montorio, Der Geschäftsführer Virgilio Montorio, Director general Virgilio Montorio, Director Geral
Appendix to the License Agreement To Use The AMCA
Certified Ratings Program Seal
Appendix No. : 26
In accordance with the License Agreement issued on March 18, 2009 by Air Movement and Control Association International, Inc.,
Maico Gulf LLC is hereby authorized to use the AMCA Certified Ratings Seal on the specific air movement and control devices
listed below. Such use shall in all respects be governed by and subject to the provisions of said License Agreement.

Centrifugal Fans

Product Line Catalog ID

TMF Centrifugal Inline Fan – 50/60 Hz Blowdyn 2.0 V2.20, July 2020

Size Model No Size Model No Size Model No


190 TMF 75 190 TMF 125 190 TMF 100
193 TMF 125-P 192 TMF 100-P 192 TMF 75-P
230 TMF 140 224 TMF 160 220 TMF-150-P
252 TMF 200 250 TMF 250 228 TMF 150 A
280 TMF 315 280 TMF 300

* License to Bear The AMCA Seal For Sound and Air Performance.

Please verify current certification status in the AMCA International Directory of Licensed Products located at www.amca.org.
Granted on January 11, 2021

Unit of Measure: mm

Nazme Mohsina Revised :


Technical Director
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

This license appendix may not be reproduced, except in full, without the written approval of AMCA International, Inc.
Appendix to the License Agreement To Use
The AMCA Certified Ratings Program Seal
Appendix No: 17
In accordance with the License Agreement issued on March 18, 2009 by Air Movement and Control Association
International, Inc., Maico Gulf LLC, is hereby authorized to use the AMCA Certified Ratings Seal on the specific air
movement and control devices listed below. Such use shall in all respects be governed by and subject to the
provisions of said License Agreement.

Centrifugal Fans
Product Line Catalog ID
Box-T BOX-T-01-07 December, 2017
Size Model Name Size Model Name Size Model Name

9.05 Box T 10-10* 9.05 Box T- 10-8* 9.92 Box T 12-12*


9.96 Box T 12-9* 12.28 Box T 15-15* 14.29 Box T 18-13*
14.29 Box T 18-18* 7.87 Box T- 200* 8.86 Box T -225*
9.84 Box T- 250* 11.02 Box T- 280* 12.4 Box T- 315*
13.98 Box T- 355* 15.75 Box T- 400* 17.72 Box T- 450*
19.68 Box T- 500* 22.04 Box T- 560* 24.8 Box T- 630*
7.08 Box T- 7-7* 8.35 Box T 9-7* 8.35 Box T 9-9*

*License to Bear the AMCA Seal for FEG Sound & Air Performance and FEG where indicated.
Only models shown in bold and indicated with * are licensed for FEG.
Please verify current certification status in the AMCA International Directory of Licensed Products located at
www.amca.org.
Granted This 12th day of December, 2017.

Nazme Mohsina
Associate Director of Certification
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

This license appendix may not be reproduced, except in full, without the written approval of AMCA International, Inc. Page 1 of 1
Appendix to the License Agreement To Use
The AMCA Certified Ratings Program Seal
Appendix No: 16
In accordance with the License Agreement issued on March 18, 2009 by Air Movement and Control Association
International, Inc., Maico Gulf LLC, is hereby authorized to use the AMCA Certified Ratings Seal on the specific air
movement and control devices listed below. Such use shall in all respects be governed by and subject to the
provisions of said License Agreement.

Centrifugal Fans
Product Line Catalog ID
DBC Double Inlet Centrifugal Fan Backward Impeller DBC-01 January, 2017
Size Model Name Size Model Name Size Model Name

1000 DBC 1000* 200 DBC 200* 225 DBC 225*


250 DBC 250* 280 DBC 280* 315 DBC 315*
355 DBC 355* 400 DBC 400* 450 DBC 450*
500 DBC 500* 560 DBC 560* 630 DBC 630*
710 DBC 710* 800 DBC 800* 900 DBC 900*

*License to Bear the AMCA Seal for FEG Sound & Air Performance and FEG where indicated.
Only models shown in bold and indicated with * are licensed for FEG.
Please verify current certification status in the AMCA International Directory of Licensed Products located at
www.amca.org.
Granted This 22nd day of February, 2017.

Dan Manole
Director of Certification Programs
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

This license appendix may not be reproduced, except in full, without the written approval of AMCA International, Inc. Page 1 of 1
Appendix to the License Agreement To Use
The AMCA Certified Ratings Program Seal
Appendix No: 15
In accordance with the License Agreement issued on March 18, 2009 by Air Movement and Control Association
International, Inc., Maico Gulf LLC, is hereby authorized to use the AMCA Certified Ratings Seal on the specific air
movement and control devices listed below. Such use shall in all respects be governed by and subject to the
provisions of said License Agreement.

Centrifugal Fans
Product Line Catalog ID
DCE Ceiling Exhaust Fan DCE 02-14 March, 2014
Size Model Name Size Model Name Size Model Name

3.82 DCE 100A - 50 Hz 3.82 DCE 100A - 60 Hz 4.25 DCE 100B - 50 Hz


4.25 DCE 100B - 60 Hz 4.72 DCE 200A - 50 Hz 4.72 DCE 200A - 60 Hz
5.51 DCE 200B - 50 Hz 5.51 DCE 200B - 60 Hz 3.34 DCE 50A - 50 Hz
3.34 DCE 50A - 60 Hz

*License to Bear the AMCA Seal for Sound and Air Performance

Please verify current certification status in the AMCA International Directory of Licensed Products located at
www.amca.org.
Granted This 10th day of March, 2014.

Lisa R. Ullrich
Certified Ratings Program Manager
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

Page 1 of 1
Appendix to the License Agreement To Use The AMCA
Certified Ratings Program Seal
Appendix No. : 21
In accordance with the License Agreement issued on March 18, 2009 by Air Movement and Control Association International, Inc.,
Maico Gulf LLC is hereby authorized to use the AMCA Certified Ratings Seal on the specific air movement and control devices
listed below. Such use shall in all respects be governed by and subject to the provisions of said License Agreement.

Power Roof Ventilators

Product Line Catalog ID

FCS Roof Exhaust Centrifugal Fan, Direct Drive Blowdyn 2.0 V2.20, July 2020

Size Model No Size Model No Size Model No


355 FCS 355 D 300 FCS 300 D 500 FCS 500 D
400 FCS 400 D 450 FCS 450 D 800 FCS 800 D
630 FCS 630 D 710 FCS 710 D

* License to Bear The AMCA Seal For Sound and Air Performance.

Please verify current certification status in the AMCA International Directory of Licensed Products located at www.amca.org.
Granted This 2/6/2020

Unit of Measure: mm

Nazme Mohsina Revised :


Technical Director
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

This license appendix may not be reproduced, except in full, without the written approval of AMCA International, Inc.
Appendix to the License Agreement To Use
The AMCA Certified Ratings Program Seal
Appendix No: 11
In accordance with the License Agreement issued on March 18, 2009 by Air Movement and Control Association
International, Inc., Maico Gulf LLC, is hereby authorized to use the AMCA Certified Ratings Seal on the specific air
movement and control devices listed below. Such use shall in all respects be governed by and subject to the
provisions of said License Agreement.

Centrifugal Fans
Product Line Catalog ID
PRL-TC SISW Backward Curve Centrifugal Fan PRL TC 01-13 May, 2013
Size Model Name Size Model Name Size Model Name

39 PRL-TC 1000* 44 PRL-TC 1120* 12 PRL-TC 315*


14 PRL-TC 355* 16 PRL-TC 400* 18 PRL-TC 450*
20 PRL-TC 500* 22 PRL-TC 560* 25 PRL-TC 630*
28 PRL-TC 710* 30 PRL-TC 800* 35 PRL-TC 900*

*License to Bear the AMCA Seal for FEG Sound & Air Performance and FEG where indicated.
Only models shown in bold and indicated with * are licensed for FEG.
Please verify current certification status in the AMCA International Directory of Licensed Products located at
www.amca.org.
Granted This 7th day of June, 2013.

Lisa R. Ullrich
Certified Ratings Program Manager
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

Page 1 of 1
Appendix to the License Agreement To Use The AMCA
Certified Ratings Program Seal
Appendix No. : 19
In accordance with the License Agreement issued on March 18, 2009 by Air Movement and Control Association International, Inc.,
Maico Gulf LLC is hereby authorized to use the AMCA Certified Ratings Seal on the specific air movement and control devices
listed below. Such use shall in all respects be governed by and subject to the provisions of said License Agreement.

Axial Fans

Product Line Catalog ID

TAHP High Performance Ducted Axial Fans Blowdyn 2.0 V2.19, July 2019

MG-TA-HP-01-19 January 2019

Size Model No Size Model No Size Model No


1112 TAHP-1120-297-6-6* 1112 TAHP-1120-406-12-12* 1112 TAHP-1120-406-12-9*
1112 TAHP-1120-406-12-6* 1242 TAHP-1250-406-12-6* 1242 TAHP-1250-297-6-6*
1242 TAHP-1250-406-12-9* 1400 TAHP-1400-523-9-9* 1242 TAHP-1250-406-12-12*
1598 TAHP-1600-523-9-6* 1400 TAHP-1400-523-9-6* 1598 TAHP-1600-523-9-9*
397 TAHP-400-240-12-6 397 TAHP-400-150-6-6* 397 TAHP-400-240-12-9
446.5 TAHP-450-150-6-6* 446.5 TAHP-450-240-12-6 397 TAHP-400-240-12-12
446.5 TAHP-450-240-12-9 496 TAHP-500-150-6-6* 446.5 TAHP-450-240-12-12
496 TAHP-500-240-12-9* 496 TAHP-500-240-12-6* 496 TAHP-500-240-12-12*
556 TAHP-560-240-12-6* 556 TAHP-560-150-6-6* 556 TAHP-560-240-12-9*
626 TAHP-630-240-12-12* 556 TAHP-560-240-12-12* 626 TAHP-630-150-6-6*
705 TAHP-710-240-12-9* 626 TAHP-630-240-12-6* 705 TAHP-710-240-12-6*
705 TAHP-710-240-12-12* 626 TAHP-630-240-12-9* 705 TAHP-710-150-6-6*
793 TAHP-800-297-6-6* 793 TAHP-800-406-12-9* 793 TAHP-800-406-12-6*
894 TAHP-900-406-12-6* 793 TAHP-800-406-12-12* 894 TAHP-900-297-6-6*
993 TAHP-1000-297-6-6* 894 TAHP-900-406-12-12* 894 TAHP-900-406-12-9*
993 TAHP-1000-406-12-6* 993 TAHP-1000-406-12-12* 993 TAHP-1000-406-12-9*

* License to Bear The AMCA Seal For Air Performance, FEG Air Performance, Sound and Air Performance, FEG Sound & Air
Performance.
Only models shown in bold and indicated with * are licensed for FEG.
Please verify current certification status in the AMCA International Directory of Licensed Products located at www.amca.org.
Granted This 1/15/2019

Unit of Measure: mm

Nazme Mohsina Revised : 7/8/2019


Technical Director
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

This license appendix may not be reproduced, except in full, without the written approval of AMCA International, Inc.
Appendix to the License Agreement To Use The AMCA
Certified Ratings Program Seal
Appendix No. : 24
In accordance with the License Agreement issued on March 18, 2009 by Air Movement and Control Association International, Inc.,
Maico Gulf LLC is hereby authorized to use the AMCA Certified Ratings Seal on the specific air movement and control devices
listed below. Such use shall in all respects be governed by and subject to the provisions of said License Agreement.

Axial Fans

Product Line Catalog ID

VA-HT (F400) Blowdyn 2.0 V2.20, July 2020 (Electronic)

Size Model No Size Model No Size Model No


1105 VAHT-1120-406-12-12-9* 1105 VAHT-1120-406-12-6-5* 1105 VAHT-1120-406-12-9-7*
1234 VAHT-1250-406-12-9-7* 1105 VAHT-1120-297-6-6-5* 1234 VAHT-1250-406-12-6-5*
395 VAHT-400-150-6-6-5* 1234 VAHT-1250-297-6-6-5* 395 VAHT-400-240-12-9-7*
395 VAHT-400-240-12-12-9* 1234 VAHT-1250-406-12-12-9* 444 VAHT-450-240-12-12-9*
444 VAHT-450-240-12-6-5* 395 VAHT-400-240-12-6-5* 493.5 VAHT-500-240-12-9-7*
493.5 VAHT-500-150-6-6-5* 444 VAHT-450-150-6-6-5* 493.5 VAHT-500-240-12-12-9*
552 VAHT-560-240-12-12-9* 444 VAHT-450-240-12-9-7* 552 VAHT-560-150-6-6-5*
552 VAHT-560-240-12-6-5* 493.5 VAHT-500-240-12-6-5* 622 VAHT-630-240-12-6-5*
622 VAHT-630-240-12-9-7* 552 VAHT-560-240-12-9-7* 622 VAHT-630-240-12-12-9*
701 VAHT-710-150-6-6-5* 622 VAHT-630-150-6-6-5* 701 VAHT-710-240-12-9-7*
789 VAHT-800-406-12-6-5* 701 VAHT-710-240-12-6-5* 888 VAHT-900-297-6-6-5*
789 VAHT-800-297-6-6-5* 701 VAHT-710-240-12-12-9* 888 VAHT-900-406-12-12-9*
789 VAHT-800-406-12-9-7* 789 VAHT-800-406-12-12-9* 987 VAHT-1000-297-6-6-5*
888 VAHT-900-406-12-6-5* 888 VAHT-900-406-12-9-7* 987 VAHT-1000-406-12-12-9*
987 VAHT-1000-406-12-6-5* 987 VAHT-1000-406-12-9-7*

* License to Bear The AMCA Seal For FEG Sound & Air Performance.
Only models shown in bold and indicated with * are licensed for FEG.

Please verify current certification status in the AMCA International Directory of Licensed Products located at www.amca.org.
Granted This 9/4/2020

Unit of Measure: mm

Nazme Mohsina Revised :


Technical Director
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

This license appendix may not be reproduced, except in full, without the written approval of AMCA International, Inc.
NOTICE OF COMPLETION
AND
AUTHORIZATION TO APPLY THE UL MARK

MAICO GULF L L C
Plot #P 299 & 301
Al Ghail Industrial Park
Po Box 9014
Ras Al Khaimah
AE

Our Reference: File E356822, Vol. 1 Sec. 1 Project Number : 4788521157.2


Your Reference: Project No. 4788521157
Project Scope: cULus File E356822, Vol. 1 Sec. 1: revision File to extend the Listing to 60 Hz and to expand
the Listing of the fans series “TA-HT” tested under Test Record No. 1

Dear Sir,
Congratulations! UL's investigation of your products have been completed under the above Reference Number and
the product was determined to comply with the applicable requirements. This letter temporarily supplements the UL
Follow-Up Services Procedure and serves as authorization to apply the UL Mark at authorized factories under UL's
Follow-Up Service Program. To provide your manufacturer(s) with the intended authorization to use the UL Mark,
you must send a copy of this notice to each manufacturing location currently authorized under File E356822, Vol. 1
and including any special instructions as indicated in the addendum to this letter.

Records in the Follow-Up Services Procedure covering the product are now being prepared and will be sent in the
near future. Until then, this letter authorizes application of the UL Mark for 90 days from the date indicated above.

Additional requirements related to your responsibilities as the Applicant can be found in the document “Applicant
responsibilities related to Early Authorizations” that can be found at the following web-site: http://www.ul.com/
EAResponsibilities

Any information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC
(UL) or any authorized licensee of UL.

We are excited you are now able to apply the UL Mark to your products and appreciate your business. Feel free to
contact me or any of our Customer Service representatives if you have any questions.

Very truly yours, Reviewed by:

Mauro V. Cerioli Bruce A. Mahrenholz


+39 02 9252 6536 847-664-3009
Senior Project Engineer CPO Director
Mauro.Cerioli@ul.com Bruce.A.Mahrenholz@ul.com

NBK9404-83FBE4

This is an electronically generated letter. Signatures are not required for this document to be valid. Page 1 of 1
6/12/2021 VENTILATORS, POWER | UL Product iQ

ZACT.E356822 - VENTILATORS, POWER

Ventilators, Power
See General Information for Ventilators, Power

MAICO GULF L L C E356822


Plot #P 299 & 301
Al Ghail Industrial Park
Po Box 9014
Ras Al Khaimah, UNITED ARAB EMIRATES

Power Ventilators, Fan, "TA-HP", Model(s) TA-HP, TA-HP1000, TA-HP1120, TA-HP1250, TA-HP1400, TA-HP1600, TA-HP400, TA-HP450, TA-HP500,
TA-HP560, TA-HP630, TA-HP710, TA-HP800, TA-HP900

Power Ventilators, Fan, "TA-HT", Model(s) TA-HT, TA-HT1000, TA-HT1120, TA-HT1250, TA-HT1400, TA-HT1600, TA-HT400, TA-HT450, TA-HT500,
TA-HT560, TA-HT630, TA-HT710, TA-HT800, TA-HT900

Power ventilators, roof mounted, belt drive, Model(s) FCVS-B06+, FCVS-B08+, FCVS-B10+, FCVS-B12+, FCVS-B15+, FCVS-B18+, FCVS-B21+,
FCVS-B24+, FCVS-B30+, FCVS-B36+, FCVS-B42+, FCVS-B48+

Power ventilators, roof mounted, direct drive, Model(s) FCVS-D06+, FCVS-D08+, FCVS-D10+, FCVS-D12+, FCVS-D15+, FCVS-D18+

Power ventilators, wall mounted, Model(s) QCSB20, QCSB24, QCSB30, QCSB36, QCSB42, QCSB48, QCSD09, QCSD10, QCSD11, QCSD12,
QCSD13, QCSD14, QCSD15, QCSD16, QCSD17, QCSD18, QCSD19, QCSD20, QCSD21

+ - Followed by suffixes.

Last Updated on 2021-12-06

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading
manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission
from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following
format: "© 2019 UL LLC"

https://iq.ulprospector.com/en/profile?e=241923 1/1
Projects list-KSA
1of8

PROJECT LIST FOR DYNAIR FANS (KSA)


SR. NO. PROJECTS MEP CONTRACTOR CLIENT / CONSULTANT

1 King Abdullah Sport City. NESMA ARAMCO.

Omrania /King Salman Center For


2 Radisson Blue Hotel Project Riyadh Riyadh Development Company
Disability Research.

3 Prince Sultan Bussiness center Al Tameer Contracting Co. ODEC

4 Tabouk Hotel El Seif Contracting Co. El Seif Contracting Co.

5 National Guard Housing Projects EFECO SBG

6 National Guard Housing Projects Axal Arabia Saudi Bin Laden

7 Hail Hotel El Seif Contracting Co. El Seif Contracting Co.

8 National Guard Housing Projects Orascom Saudi SBG

9 National Guards Housing Project Haramain Gate SBG

10 Al Jawahar Tower-Jeddah Drake and Scull Al Salama Structural Engineers

El Seif Engineering Contracting


11 Head Office-Renovation,CAP-006 El Seif Engineering Contracting Co.
Co.

12 King Faisal Speciality Hospital Al Bawani Contracting Co. Ministry Of Health

El Seif Engineering Contracting Saudconsult/University Higher


13 Hail Mall at Hail City
Co. Education Fund.

Al Sayed & Partners Contracting


14 Sulaiman Al Habib Hospital Sulaiman Al Habib Hospitals
Co. Ltd

15 Haya Rabaw Compound, Club House Saudi Inteltec Al Latifiah Contracting Co.

16 Najran Housing Project Bait Al Saquie Ministry Of Defence

El Seif Engineering Contracting


17 ESEC Extn Office Basement floor HVAC El Seif Engineering Contracting Co.
Co.

Four Horizons SA & Emmar


18 Rehab. & Expansion of SWTP, Yanbu Yanbu Est. General Contracting POSCO
and Constructions.
2of8

19 Rafal Living Center Sterling & Wilson Erga Saudi

Saudconsult/General Authority Of
20 KKIA Terminal-5 (T5) Project AKFA Contracting Co.
Civil Aviation

21 Bateel Sheikh Avenue (Al Khobar) Saudi Icon Bateel Café

22 Bateel Sheikh Avenue (Riyadh) Saudi Icon Bateel Café

23 Nandos Restaurant. Saudi Icon Nandos Restaurant.

24 Operation Falafeel Saudi Icon Saudi Icon

25 Qurtuba Villa Project Mimar International Saudi Diyar

26 Toki Restaurant Modern Electric Contractors V3 Middle East

United Constructors Contracting


27 Princess Noura Beach House Design Engineering Partners
Co. Ltd

28 Al Rajhi Bank Headquater Tower Samsung CCEJV Al Rajhi Investment Co.

El Seif Engineering Contracting


29 KFAB-Tabuk Flight Training Facility El Seif Engineering Contracting Co
Co

30 King Fahad Medical City Drake and Scull Ministry Of Health

Hail Mall+Tabuk Hotel(P122+P124) Saudconsult/University Higher


31 El-Seif Contracting Co.
additional Fans Education Fund.

King Faisal Airbase (HAWK-T165),


32 El-Seif Contracting Co. Royal Saudi Airforce
Tabuk(GSE- Building)

King Faisal Airbase (HAWK-T165),


33 El-Seif Contracting Co. Royal Saudi Airforce
Tabuk(CC and MPDF- Building)

King Faisal Airbase (HAWK-T165),


34 El-Seif Contracting Co. Royal Saudi Airforce
Tabuk(Fans For EB Facility)
3of8

King Faisal Airbase (HAWK-T165),


35 El-Seif Contracting Co. Royal Saudi Airforce
Tabuk(IMF Hanger)

36 Al Raidah Housing Project MAPA KEO

37 Cocacola Factory, Sudair Saudi Amana Contracting Co. Cocacola

38 Landmark Warehouse Saudi Amana Contracting Co. Landmark Properties

39 KAP2A Site8 & Site9 Elseif Contracting Co. NKY

40 Marriott Hotel Project Specialized Contracting Co. DUR

41 Al Salamah Compound Shell Western Contracting Co. ARABTECH

42 Rafal Residence Al Futtaim Engineering Erga Saudi

43 El Seif-MEP head office El Seif Contracting Co. El Seif Contracting Co.

44 DQ Marriott Shapoorji Pallonji Mideast Co. DUR

45 RC-Labour Camp 21 C09 Abdullah Mishal Contracting Co. RCJ

46 Radisson Blu Convention Center Al Latifia Contracting Co. HYKAL

47 Burger Boutique. Fresh Air Fans Saudi Icon Burger Boutique

Dr. Sulaiman Al Habib Hospital


48 Saudi Aircon Dr. Sulaiman Al Habib
(Al Khobar)

49 Hospital King Faisal Naval Base-Jeddah Tawareef Contracting Co. Ministry Of Defence

Beijing Emirates Construction


50 Mayasem Development Jeddah KPFF Global
Co.

51 Bank Albilad Headquarter, Riyadh Astrum Electromechanical Al Mutlaq & Bu-Nahayah

52 United Compounds Factory Asia General Contracting Polyca

IKEA Al Hofouf Order and Collection Point


53 DOSAN IKEA/V3 Middle East
Al Ahsa mall
4of8

PROJECT LIST FOR DYNAIR FANS (UAE)


SR. NO. PROJECTS MEP CONTRACTOR CLIENT / CONTRACTOR

1 Dubai Industrial City Al Hamad Contracting MEECON

3B+G+13 Res. Bldg Plot No 134-1036/134-


2 Conversion National Engineering Bureau
1037 at Al Mamzar

3 Sky View Tower Eagle Electromechanical National Engineering Bureau

4 NMC Hospital Menasco Consultair

5 Marina Pinacle Tiger Contracting National Engineering Bureau

6 Aweer Gas Power Station Phase 2 ETA Mott Macdonald

7 Aweer Gas Power Station Phase 3 ETA Mott Macdonald

8 3B+G+3P+12 (Ivory 1) Sobha National Engineering Bureau

9 3B+G+3P+12 (Ivory 2) Sobha National Engineering Bureau

10 Comm / Off Bldg Port Saeed Prime Star DAR

11 The Palladium Bin Shafar Electro Mechanical Elite Engineering

Substations (Palm-Deira, Jebel Ali,


12 Essa Engineering Mott Macdonald
Jumeirah)

13 Qasco Factory Sobha Chawla Architects

14 G+7 Al Ittihad Style Consultants

15 Labour Accommodation Aikah MEECON


5of8

16 2B+G+5P+22 at Tecom Al Reyami Electro Mechanical National Engineering Bureau

17 Jumeirah Park Villas ETA DAR

18 Al Ghurair City Expansion Phase 2 ETA Whitby & Bird

19 B+G+2 at Aweer Al Naboodah Power Choice

20 3B+G+2P+14 (Murad Tower) Aikah Shadid Engineering

Ian Banham & Associates &


21 Sky Courts China State
LACASA

22 Bay Gate Tower China State Whitby & Bird

23 Mirdiff Villas & Apartments China State Kling Consultant

24 183 Villas Bindasmal Dynamic

25 Badrah Development Waterfront Bauer Whitby & Bird

26 Jumeirah Park Villas Power Point DAR

27 2B+G+24 Bindasmal Bel Yoahah

28 3 Towers for Mazaya Radiant National Engineering Bureau

29 The Buildings By DAMAN @ DIFC ETA Arif & Bintoak

30 G+30 at Sharjah ETTS Syr Consultants

31 G+4 Knowledge Village ETTS National Engineering Bureau

32 Doora Bay Tower Al Reyami Electro Mechanical National Engineering Bureau


6of8

33 HS101 - 9 buildings Al Habtoor Ian Banham

34 International City - Package 13 Ranya - Test Contracting ACE International

35 The Palm Jumeirah - Shoreline Apartments Bin Belaila Baytur LLC ACE International

Dubai Civil Engineering / Dubai


36 Jumeirah Int'l Staff Accommodation Rice Perry Ellis
Properties

37 F2 and T2 tower Trinity Engineering National Engineering Bureau

Eagle Electromechanical Co.


38 The Palm Jumeirah - Shoreline Apartments ACE International
LLC

Emirates Electromechanical &


39 The Palm Jumeirah - Shoreline Apartments ACE International
Industry

40 International City - Package 11 Dhabi Contracting ACE International

41 International City - Package 09 Nurol LLC ACE International

42 International City - Package 07 ARJ Engineering Services ACE International

Dubai Masters Electro


43 G+2 Building (18 nos.) Labour Accommodati LACASA
Mechanical

44 2B+G+10 Flrs CDB-16 Bin Shafar Electro Mechanical National Engineering Bureau

45 Majestic Tower Universal Voltas CAB

46 G+P+13 Storied Bldg+Clubhouse Omega Engineering Archon Consultants

47 B+G+8 at Al Barsha DAMCO LLC Al Ajmi Consultants

48 Palm Jumeirah Emirates Watertech SPP Consultants

49 96 villas Strabag Mario Associates


7of8

50 2B+G+10 at Al Warsan Bin Shafar Electro Mechanical National Engineering Bureau

51 Warehouse for Landmark Grp Roshan Contracting Chawla Architects

52 B+G+12 Tower, Abu Hail Al Futtaim Engineering Al Injaz Consultants

53 Indigo Tower Project Drake and Scull W.S. Atkins

54 Garden Tower Dubai Geco Mechanical Shadid Engineering

55 3B+G+30Res. Tower, Dubai Marina Al Hamad Contracting Gemac Consultants

56 Modern Plastic Al Shirawi Arif & Bintoak

57 Military Tank Sheds Rusdi & Partners Ministry of Defence

58 Deira City Centre Al Futtaim Engineering Mott Macdonald

59 Medical Disposal Plant Amana Steel Mott Macdonald

60 SHJ 007 MW 1890 Amana Steel Ministry of Defence

61 G + 10 Bldg at Sharjah Emjem Al Turath

62 Gulf Advanced Lighting FNC Model Engineering

63 B + G + 4 Residential Complex Transgulf Development Consultants

64 Harman House - Jebel Ali FNC RMJM

65 Leo Burnet Office at Media City Sensaire Mario Associates

66 United Motors Amana Steel In House


8of8

67 Danzas Emirates Amana Steel PHB Group

68 B + G + 15 at Sharjah Al Hamad Contracting Test Consultants

69 Gharood Appartments RAS Engineering Khatib & Alami

70 Al Rostamani Building Al Rostamani Ian Banham

71 Jumeirah Islands Technomat - GIT Diar

72 Fardan Ali Fardan Al Hamad Contracting Ian Banham

73 Police Camp RAS Engineering Dubai Police

74 B+G+7 Mr.Nasser Lootah Test Consultants

75 Police Camp Power Point Dubai Police

76 Warehouses for ADWEA Shepherd Contracting ADWEA

H.H. Sheikh Ahmed Bin


77 126 Feet Dhow DIMC
Makhtoum

78 New Hotel at Dhafra Damas Contracting Syna Consultants

79 Al Hosham Pan Gulf FNC Orion

80 Sharjah Science Museum Ministry of Heritage Khatib & Alami


Approvals
Saudi Aramco E-Reference No. 0003038

Registration Approval Letter


September 29, 2020

Attention : HIRA INDUSTRIES L.L.C.

CR Number : 1010950396
Country : Saudi Arabia
We are pleased to inform you that HIRA INDUSTRIES L.L.C. is now registered in the Saudi Aramco Supplier
Management System under Vendor Code No. 10067242, provided your company continues to meet all
relevant Saudi Arabian and Saudi Aramco standards.

This registration, however, should not be construed as a commitment by Saudi Aramco to procure from you.
Being registered as a supplier only grants your company the opportunity, along with other registered
sources, to respond to requests for submitting proposals in accordance with Saudi Aramco's established
policies and procedures. All procurement instruments including but not limited to service contracts, purchase
agreements, or purchase orders will be issued based on the name and address included in your commercial
registration (CR), as stated in your Supplier Registration.

Saudi Aramco wishes to remind you that being recognized as a supplier carries with it serious obligations
and responsibilities to act in a legal and ethical manner. We wish to remind you of the Saudi Aramco
Supplier Code of Conduct (SCOC) which you acknowledged. Failure to abide by the principles set forth in
the SCOC can result in adverse actions being taken by Saudi Aramco against you including suspension of
you as a supplier. Saudi Aramco also expects each of its suppliers to satisfy each of the requirements of any
procurement instrument which might be placed and to act responsibly and reliably as a supply chain supplier.

Material Suppliers should apply for Saudi Aramco Supplier Portal access by forwarding a request to
portal-registration@aramco.com. The Supplier Portal is the main electronic business tool used between
Saudi Aramco and its suppliers and serves to improve the flow and accuracy of key supply chain information.

For further information or assistance please contact the Saudi Aramco Supplier Help Desk by forwarding a
request to SupplierHelpDesk@aramco.com or via the unified call center +966 (13) 874-2222.

Dawoud Suliman Al Nuwais, Supervisor


Supplier Registration Unit
Supplier Relationship Management Div

It is the responsibility of the supplier to update Saudi Aramco Supplier Registration Profile thorugh Ariba for
the following:
1. Change of Name / Commercial Registration Number / Address / Owner(s)
2. Any change of the supplier location
3. Discontinue supply of approved commodities (9COMs and 9CATS)

This is an electronically generated letter by Saudi Aramco. To verify Supplier approval status, please contact
Supplier Help Desk at supplierhelpdesk@aramco.com
1/20/22, 10:11 AM Aconex

Ayman Negm Final (WF-009369) 14-4800000322/000-IN-Project Mana… 30/12/2021


AECOM WORKFLOW TRANSMITTAL ACM-WTRAN-021766

14 Outer Regions
Riyadh, KSA
Riyadh
Saudi Arabia

MAIL TYPE MAIL NUMBER REFERENCE NUMBER


Workflow Transmittal ACM-WTRAN-021766 ACM-WTRAN-021766

Final (WF-009369) 14-4800000322/000-IN-Project Management - IFR-PQD

From Mr Ayman Negm - AECOM

To
(2) Mr Ayman Negm - AECOM (+1 more...)

Cc
(7) Mr Soner Keskinel - AECOM (+6 more...)

Sent Thursday, 30 December 2021


11:38:19 AM AST (GMT +03:00)

Status N/A


DOCUMENT ATTACHMENTS
(2)

(0 selected)

Revision
File Document No Revision Title Status
Date

4800000322/000 - Pre-Qualification Of HUSSEIN A - Work


14-662000-4800000322-
01 20/12/2021 G.I. SHAKER TRADING EST For Ventilation May
MOB-MEC-CRS-000039
System (Fans) Proceed

4800000322/000 - Pre-Qualification Of HUSSEIN A - Work


14-662000-4800000322-
01 20/12/2021 G.I. SHAKER TRADING EST For Ventilation May
MOB-MEC-PQD-000015
System (Fans) Proceed


MESSAGE

Workflow Review History

The attached documents have completed the "14-4800000322/000-IN-Project Management - IFR-PQD" workflow with the following results :

This transmittal was automatically generated.

Doc No Step Participant Review Outcome Comments

14-662000-4800000322- NEOM/AECOM_Review A Negm A - Work May Proceed No Objection

https://ksa1.aconex.com/Logon?mainTarget=%2FViewCorrespondence%3FCorrespondence_ID%3D1351756138%26CORRESPONDENCE_MAILBO… 1/2
1/20/22, 10:11 AM Aconex

MOB-MEC-PQD-000015

14-662000-4800000322-
NEOM/AECOM_Review A Negm A - Work May Proceed No Objection
MOB-MEC-CRS-000039

https://ksa1.aconex.com/Logon?mainTarget=%2FViewCorrespondence%3FCorrespondence_ID%3D1351756138%26CORRESPONDENCE_MAILBO… 2/2
Products catalogue
A

INDUSTRIAL AND BUILDING


VENTILATION FANS
60HZ

NOW MADE IN UAE


VENTILATOREN

Maico Elektroapparate-Fabrik GmbH


Residential and industrial ventilation

Aerex HaustechnikSysteme GmbH

GULF

Residential and industrial ventilation Certificates

ITALIA

Residential and industrial ventilation Member of

Italian Electric and Electronical Association

Italian Association of Aeraulic Companies


GROUP

BSB Engineering Service Ltd.


Dampers and fire dampers

Italian HVAC Association

Commercial subsidiary

®
Fan Company Air Movement and Control Association

USA - Commercial subsidiary

Home Ventilation Institute


CHINA

Commercial subsidiary

Italian Fire Protection Association


POLAND

Commercial subsidiary

HUNGARIA

Commercial subsidiary

INDIA

Commercial subsidiary
INDUSTRIAL AND BUILDING VENTILATION FANS 1
INDEX Technical Introduction
FCS FCVS DRF sez.

Roof fans
LISTED LISTED
1
Pg. 13

TA-HP sez.

Ducted axial fans


LISTED
2
Pg. 57

PRL-TC sez.
SISW Backward curved belt
driven centrifugal fans 3
Pg. 111

TMF sez.

In line centrifugal fans 4


Pg. 131

BOX-D TW-D sez.


Box type direct driven
centrifugal fans 5
Pg. 141

DCE sez.

Ceiling exhaust fan


6
Pg. 161

BOX-T TW-D/ T sez.


Box type belt driven
centrifugal fans 7
Pg. 167

sez.

Speed regulators 8
Pg. 197

AMCA Certified performance


LISTED
2
Technical Introduction

1. DEFINITIONS 1.2 STATIC, DYNAMIC AND TOTAL PRESSURE

Fan performance are usually expressed through a characteristic When a fluid is in movement, there are three types of pressures
curve that, for a certain revolution per minute of the impeller involved. Pressure is normally expressed in pascal (Pa), mil-
and for specific air conditions, provides the value of the static limetres of water gate (mmH2O 0mm WG) or inches of water
pressure (ps) or total pressure (pt), given the volumetric flow gate (inWG).
rate (Q). Also, the value of the absorbed mechanical power (Pw)
and the efficiency (n) are expressed given the volumetric flow Static pressure (ps)
rate (Q). It is defined as the pressure applied by the fluid to the wall of
the duct or of the container in which its held. It expresses the
1.1 FLOW RATE potential energy suitable to overcome the resistance given by
the system to the fluid transit. It acts equally in every direction
Volumetric flow rate is the fluid volume that passes through the and it is independent from fluid speed.
fan in a specific amount of time. It is normally expressed in cu-
bic meters per hour (m3/h), cubic meters per second (m3/s) or With reference to environment pressure, static pressure is posi-
cubic feet per minute (cfm). tive when it is bigger than ambient pressure and negative when
it is lower.
The relationship between the flow rate of a ducted fan, the speed
of the fluid in the duct and the cross section area of the duct Dynamic pressure (pd)
itself is expressed by the following formula: It is defined as the pressure related to the energy that belongs
to the mass unit of the fluid because of its speed. It expresses
Q the kinetic energy of the fluid in movement. It acts in the same
V= (1.1) direction of the fluid movement and it is always positive.
A*3600 The dynamic pressure is function of fluid speed and density and
it is expressed by the following formula:

where: pd = 1/2 * r * V² (1.2)


V = fluid average speed in m/s
Q = flow rate in m3/h where:
A = duct cross section area in m² pd = dynamic pressure in Pa
r = fluid density in kg/m3
V = fluid speed in m/s
Total pressure (pt)

Total pressure (pt) 1.3 ABSORBED POWER AND EFFICIENCY


It is defined as the algebraic sum of static pressure (ps) and
dynamic pressure (pd): A fan needs some mechanical power to give a certain flow
rate at a certain total pressure. This mechanical power de-
pt = ps + pd (1.3) pends on the efficiency of the fan and is expressed by the
following formula:
When a fan is operating with shut inlet or outlet, flow rate is Q*pt *100
null. So, fluid speed and consequently, dynamic pressure are Pw= (1.4)
null. Therefore, the result is: h
where:
pt = ps Pw = mechanical power in W
Q = flow rate in m3/s
This working condition corresponds to the start point (on the pt = total pressure in Pa
left) of the fan performance curve. h = fan aeraulic efficiency in %
When a fan is operating with free inlet and outlet (both inlet Mechanical power is given by an electric motor that absorbs
and outlet not ducted), static pressure is null. Therefore, the a certain electrical power from the power supply network.
result is: Following formulas are commonly used:
pt = pd - three-phase motor
Pe= V * I * √
Pw
This working condition corresponds to the end point (on the 3 * cos ϕ = (1.5)
right) of the fan performance curve. h mot
- mono-phase motor
Pw
Pe= V * I * cos ϕ = (1.6)
h mot
where:
Pe = electrical power absorbed from power supply network in W
Pw = mechanical power in W
I = absorbed power in A
V = supply voltage in V
hmot = motor efficiency in %

3
1.4 WORKING POINT A fan installed in a system will give airflow corresponding to the
value of static pressure necessary to overcome the resistance to
The energy that a fan receives from the electric motor is trans- the air movement in the system.
ferred to the volume unit of fluid in transit in the form of pres-
sure. The pressure that a fan can give is not constant but, it is If the static pressure curve of the fan (fan characteristic curve)
a function of the flow rate according to the fan characteristic and the aeraulic resistance curve (system characteristic curve)
curve. Also, the absorbed power varies with the flow rate. are drawn on the same diagram, the crossing point of the two
curves will be the working point (see Fig 1).
To have a certain amount of air circulating in a system, it is nec-
essary to apply to the fluid a certain energy, in the form of pres-
sure, to win the frictions encountered in the movement. P System characteristic curve

The pressure to be applied varies with the flow rate and is given Max Fan pressure
by the following formula:

p= Kr * Q² (1.7) 1

Required pressure
where: Fan performance curve
p = pressure needed by the system
Kr = factor depending on system characteristics
Q = airflow
Kr factor remains constant for variations not too big of the air-
flow and can be obtained starting from the 1.7 in a certain work- Q
ing point, calculated or measured.
Once Kr factor is obtained, it is possible to draw a curve of p Required airFlow
against Q, that is the system characteristic curve.
FIG. 1

Introduzione Tecnica

Technical Introduction

1.5 VARIATION IN AIR DENSITY 2 FANS CLASSIFICATION


The characteristics of fans in the Dynair catalogue refer to Fans are rotational machines that are able to create a continu-
working conditions with air at 15°C and at 0 m above sea lev- ous air flow with an aerodynamic action. There are substantially
el, that means with density r = 1,225 kg/m3. In case working two types of fans, axials and centrifugals. In axial fans, the air
conditions are different from standard, it is recommended stream is parallel to the impeller rotation axis and air discharge
to adjust required performance in order to make the selec- is in the same direction of the air inlet. In centrifugal fans, the
tion with performance in standard conditions (+15 °C at 0 m air stream is pushed in the radial direction from the impeller ro-
above sea level). tation axis and typically air discharge is at 90° from the air inlet.
To adjust the pressure (static or total) from real working con- Axial fans can have the impeller with metal sheet blades (gen-
ditions to standard conditions, the following formula is used: erally cut and pressed in shape) or with airfoil blades (gener-
ally in technopolimer or in aluminum alloy). There are fans for
wall, duct or roof application. Generally, given static pressure
is not high.
r0
p0 = p1* (1.8)
r1 Centrifugal fans can have forward curved, backward curved
or radial blades. There are several types: with volute casing,
in-line, roof-fans, etc. Compared to axials, they normally give
where: higher static pressure.
p0 = pressure adjusted to standard density
p1 = pressure required in real working conditions Forward curved centrifugal fans are normally small/medium
items. They are cheap and not highly efficient. As working point
r1 = air density in real working conditions moves towards free inlet/outlet condition absorbed power
r0 = standard air density (1,225 kg/m3) grows rapidly, becoming even higher than the maximum value
of the motor. Double inlet versions, direct drive or belt driven
The same relationship is valid for the fan absorbed power. are normally used in box fans or air handling units.
Airflow, instead, remains substantially unchanged.
Backward curved centrifugal fans have higher efficiency and
In section 6 of Dynair industrial catalogue, there is a table can reach bigger dimensions. Absorbed power remains with-
with air density values against variation of temperature and in motor limit, even in free inlet/outlet condition.
altitude.

4
3 FAN LAWS 4.1 SOUND POWER AND PRESSURE
Performance of Dynair geometrically similar fans can be cal- The generation of a sound (or noise) occurs when an item vi-
culated using the following relationships between rotational brates and the sound is propagated in every mean that can vi-
speed, impeller diameter and air density. brate. The sound in the air source produces alternate pressure
fluctuations around the barometric equilibrium pressure, caus-
3.1 Given a certain impeller diameter, air density and changing ing compressions and de-compressions that are propagated
the rotational speed (rpm): creating a sound wave. The value (effective value) of such fluc-
tuations are called sound pressure and measured in pascal (Pa).
2 3
rpm2 rpm2 rpm2
Q2 = Q1* p2 = p1* Pw2 = Pw1* (3.1) Human ear and any microphone sense the sound pressure it-
rpm1 rpm1 rpm1 self. Conventionally, it’s been introduced the sound pressure
level (Lp) has been expressed as:

p
3.2 Given a certain rotational speed, air density and changing Lp = 20 * log (4.1)
the impeller diameter (D): p0
3 2 5
D2 D2 D2
Q2 = Q1* p2 = p1* Pw2 = Pw1* (3.2) where:
D1 D1 D1 Lp = sound pressure level in dB
p = actual sound pressure in Pa
po = reference sound pressure (2*10^-5 Pa)
The sound emission by a certain machine implies a loss of a
certain amount of energy. Such energy, referred to time mea-
4 NOISE AND VIBRATIONS sure unit, is the sound power and is measured in watt (W). Con-
ventionally, its been introduced as the sound power level (Lw):
Fans are rotating mechanical machines so they inevitably gener-
ate noise and vibrations. The problem for designers or users is Pw
not the generation of noise and vibrations. The level of noise and Lw = 10 * log (4.2)
vibrations generated and if it is compatible with project needs Pw0
is a concern.
where:
Lw = sound power level in dB
Pw = actual sound power in W
-12
Pwo = reference sound power (1*10 W)

The same noise source with the same sound power generates The term DI represents the effect of the source directional-
different sound pressure levels depending on the distance of ity, with Q defined as directionality factor. The factor Q has
the receiving point on the position of the noise source (how different values generally between 1 and 8. It is an empiri-
close from a reflecting surface), on the environment confor- cal value, estimated according to experience. Some publica-
mation (more 0 less reverberating) and other factors. tions suggest an estimation of such values according to the
position of the fan against reflecting walls, others according
The sound power level (Lw) is an absolute quantity for each to the mutual position between the fan and the auditor in a
fan. certain environment. Indeed it is often ignored, because the
directionality effects of the sound source are covered by dif-
The sound pressure level (Lp) is the quantity perceived by the fusion phenomena created by objects and surfaces present
user and it depends on the installation, on the environment in the sound field.
and on the position of the user against the fan.
ATTENTION: The sound pressure level (Lp) indicated in every Known the sound pressure level Lp1 in a certain point 1, lo-
fan manufacturers catalogue is measured in particular test- cated at distance r1 from noise source, the Lp2 level in point
ing conditions and may be different from what is obtained in 2, at distance r2 in the same direction, can be calculated us-
a real installation. ing the following formula

4.2 SOUND PRESSURE CALCULATION


r1
Supposing there is a free field spherical propagation in an Lp2= Lp1 + 20 * log [dB] (4.4)
ideal elastic medium, the sound pressure level (Lp) at a dis- r2
tance r from a noise source with sound power level (Lw) can
be calculated with the following formula
Example:
Lp = Lw - 10 * log 4 p 2r+ DI Lp1 = Sound pressure level at 3m = 60 dB
Lp2 = Sound pressure level at 1m = 60 + 20*log3 = 69,5 dB
or
Lp = Lw - 20 * log r+ DI-11 [dB] (4.3)

where
DI = 10 * log Q

5
In case of two sources with different noise levels, the combined 4.3 SOUND SPECTRUM
value can be calculated using the following chart:
3 Normally every sound or noise consists of a mix of sounds at
[dB] different frequencies. To describing a sound better, it is some-
2
times necessary to use sound octave bands (frequencies of 63,

Increase in noise
125, 250, 500, 1000, 2000, 4000 and 8000 Hz are universally
used), indicating for each frequency the level of sound power
1 or pressure.

0 The human ear is more sensible to certain frequencies rather


0 4 8 12 16 20[dB]24 than others. For this reason, the sound pressure level is often
Difference in sound levels “weighted” (i.e. giving more weight to some frequencies rather
than others), obtaining a total sound pressure value, starting
Example: from the values at each frequency, that better reflects the hear-
Two sources have sound values of 60 and 65 dB respectively. ing sensation of the auditor. The “A” weighting scale, according
The difference is 5 dB and in the graph gives 1 as adding value. to ISO 3744 is universally the one more often used and the cal-
The combined sound level is 65 + 1 = 66 dB culated total value is normally indicated in dBA or dB(A).
In case of various sources with the same sound level, the global
value can be calculated using the following chart:
4.4 FAN LAWS FOR NOISINESS

For fan noisiness, there is a similitude law like the ones ex-
plained in Chapter 3. According to AMCA 300/67, there are fol-
lowing relationships:

rpm2
Lp2= Lp1 + 50 * log (4.5)
rpm1
Example:
Five sources have a sound level of 60 dB D2
From the graph, the adding value is 7 Lp2= Lp1 + 70 * log (4.5)
The global sound level is 60 + 7 = 67 dB D1

Introduzione Tecnica

Technical Introduction

4.5 VIBRATIONS AND BALANCING For sinusoidal vibrations the effective value of the vibrations
is equal to *еω or 0,71 еω, therefore, the effective value
The vibrations generated by a fan are normally due to the (rms) maximum acceptable is normally 4,5 mm/s.
residual unbalancing of the impeller and for this reason, es-
sentially of sinusoidal shape, with frequency equal to the ro- To minimize vibrations emission, impellers are subject to bal-
tational frequency of the impeller itself. In time, it is possible ancing. It can be either static or dynamic. The static balanc-
that the impeller residual unbalancing can increase because ing process consists of in case an impeller of mass M has
of corrosion phenomena or more commonly because of dirt a heavier side (and so a residual eccentricity equal to e), in
accumulation. Therefore, it is essential during periodical the addition of an additional weight m at a distance m dia-
maintenance to clean the impeller from such dirt deposits. metrically opposite, on the same perpendicular plane to the
impeller axis, such as
Other sources of vibrations can be the presence of turbu-
lences in the airflow (especially on fan inlet side), excessive
pressure drop, natural frequency of the support structure too
close to the fan speed, problems on motor bearings etc. An impeller can be perfectly balanced from a static point of
view, but still present a oscillating vibration in correspon-
Typical solution against vibrations transmission, from the fan dence of its shaft. This problem generally happens on impel-
to the support structure or to the duct system to which the lers of a certain thickness (generally those of the centrifugal
fan is connected, is the use of anti-vibration supports (oppor- fans).The dynamic balancing foresees the addition of addi-
tunely selected for the type of installation and for the weight tional masses on two different planes both perpendicular to
of the fan) and of anti-vibration joints. impeller axis, such to compensate the oscillating motion.
Vibrations are normally measured and described by the vi-
bration speed V [mm/s]. In case of sinusoidal vibrations, the
maximum speed of vibration is equal to the product еω,
where е is the residual eccentricity of the impeller barycen-
ter and ω is the angular speed.
The norm ISO 1940 describes the acceptable vibrations levels
according to balancing degrees (G1 - G2,5 - G6,3 - etc.). The
balancing degree normally approved for fans up to 15kW is
G6,3. The degree of balancing points out the maximum speed
of the vibrations.

6
5 MOTORS AND DRIVES

Motors installed on Dynair fans are of different types, depending


on fan typology, on application, on size etc. They can be shaded
poles motors, external rotor motors, squirrel cage motors etc.
In case of special applications, high temperature or explosion-
proof motors are used. Please refer to specific catalogue section
to know which motor type is installed on each fan range.
5.1 POWER SUPPLY
The rated power supply tension of the motors used by Dynair is
generally 230V for single-phase motors and 230/400V or 400/
690V for 3-phase motors. The frequency is 50Hz. In case of dif-
ferent tension and/or frequency, please refer to Dynair.
If the 3-phase power supply is 400V, 230/400V motors have
to be connected in star and 400/690V motors have to be con-
nected in delta.
Corrective mass 5.2 STARTING
There are different methods for starting a motor. The D.O.L.
(Direct On Line) system, or direct starting is the more common-
ly used. It has, however the disadvantage to require an elevated
starting current and this, especially in case of motors of big di-
mensions, can create problems to with power supply system
and/or towards the energy supplying company. For 400/690V
3-phase motors the most immediate solution is to use (if pos-
The balancing process can be made through rotating or non- sible) a star/delta starting. This reduces both the starting cur-
rotating machines. The balancing process made through a ro- rent and torque down to approximately one third of the values
tating machine is frequently confused with the “dynamic” bal- that would occur in case of direct starting in delta. The connec-
ancing, but the two things are completely different (being the tion in star must be done only at motor starting and for a brief
real meaning of dynamic balancing explained above). period of time.

More sophisticated starting methods foresee the use of In the case of single-phase motor with capacitor, it is ad-
drives (inverter or soft-starter) that partiality supply frequen- visable (especially in case of use of an electronic controller)
cy or tension at the start-up. that the supply tension is varied only on the primary winding,
leaving the secondary one (with capacitor) with full tension
5.3 SPEED CONTROLLING (“3-wires” connection, as described in the specific catalogue
section).
The need of controlling the performances of a ventilation
system depends on various factors: increase in comfort, FREQUENCY VARIATION
reduction noise emission, adaptation to the environmental
conditions, reduction of absorbed electric power etc. The The speed of a squirrel cage motor can be effectively con-
performances of a ventilation system can be easily controlled trolled varying the supply power frequency by means of an
by modifying the fans rotational speed. The absorption of inverter. The way of speed controlling is ideal, although gen-
mechanical power to the fan shaft is reduced by the third erally more expensive. So, it is more frequently used on big-
power of the variation of rotational speed (if speed is halved, ger size motors, in case of several motors controlled by the
the power is reduced to an eighth of the absorption at full same inverter or in case it is requires an extremely precise
speed). However, by how much the absorbed electric power speed control. Attention: not all motors can be controlled
is reduced, depends on the characteristics of motor and con- through the inverter. It is recommended to take advise from
trol drive. Dynair in advance.
There are different methods for controlling the speed of a fan. As the motor cooling impeller is fitted, as standard, to the
Below are listed the more common ones, that can be used motor shaft, consequently the cooling of the motor is re-
with Dynair fans. duced. On the other hand, the power absorbed by the motor
is reduced. In any case, it is recommendable not to reduce
TENSION VARIATION the rotational speed below 50% of nominal speed (so not
In small dimensions motors, speed can be regulated through to reduce supply frequency below 25 Hz). For motors of a
the variation of the supply tension. This type of regulation is certain size (and value), it is appropriate to foresee for the
especially suitable for shaded pole and external rotor motors. motor, a protection system against overheating (for example
There are essentially two types of controllers: electronic and using PTCs).
autotransformer. The ones with autotransformer are gener-
ally more expensive, but they increase the stability of the mo- If it is required to control a fan of small dimensions and mo-
tor, being the tension supplied independent from the load. no-phase power supply is available, a valid solution (with bet-
The tension regulation is not recommendable on 2-poles ter efficiency) is to use a small inverter with mono-phase inlet,
motors. three-phase outlet and a fan with three-phase motor.

7
DOUBLE POLARITY MOTORS - type of application (industrial, commercial, domestic etc.)
- type of installation (air intake or supply free, ducted etc.)
- kind of carried fluid (clean air, with gas or dust, tempe
It is possible to install on certain fan ranges, double polarity mo- rature, presence of explosive elements etc.)
tors. Typically 2/4, 4/6, 4/8 and 6/8 pole motors are used. This - place of installation (wall, roof, false ceiling etc.) and even
solution allows to get different fan speed simply by selecting tual limitation of space and dimensions
the polarity of the motor itself. 4/6 e 6/8 pole motors have two - eventual noise level limits
separate windings. However, 2/4 e 4/8 pole motors can have - type of power supply (tension, frequency etc.)
a single winding (Dahlander, the most commonly used as it is - eventual required accessory (anti-vibration supports or
cheaper) or two separate windings. joints, speed controller etc.)
DELTA / STAR SWITCHING
But obviously, the most important parameters for the selection
are the flow rate and in case of ducted installation, pressure
Normally three-phase motors can be started in star connection drop.
and then quickly switched to delta connection. But, they cannot
run continuously in star connection. Some specific Dynair fan 6.1 FLOW RATE
ranges (indicated in our catalogue with “2V”) are fitted with spe-
cial increased slip motors and can be run continuously in star To design a ventilation system, the first step is to know the re-
connection. The result is to have a double speed motor, similar quired air volume to be extracted or supplied from or to a certain
to a 4/6 poles motor, but more economical. environment in a certain period of time.
VARIATION OF RAPPORTO DI TRASMISSIONE
There are several criterias to calculate such air volume. Fre-
quently, different criterias can be applied at the same time to a
It is only possible only for belt driven fans and for setting the certain environment: in this case, it is recommended to use the
system during installation and commissioning. By changing one indicating the higher air volume. See below a short list of
ratio between pulleys diameters, it is possible to have any re- some of these criterias.
quired fan rotational speed and adapt very precisely fan the per-
formance to system requirements. *N° OF AIR CHANGES PER HOUR RECOMMENDED FOR
6 VENTILATION SYSTEM DESIGN A CERTAIN ENVIRONMENT TYPOLOGY
The airflow required (in m³/h) is given by environment volume
To design a ventilation system and to choose the appropriate (in m³) multiplied by recommended number of air changes per
fan and ducting (if necessary) type, it is necessary to take into hour. See table below (note: values are indicative).
account all the following elements:

Technical Introduction

*N° OF AIR CHANGES PER HOUR RECOMMENDED BY 6.2 PRESSURE DROP


NUMBER OF PEOPLE IN THE ENVIRONMENT

The airflow required (in m³/h) is given by the number of In case of ducted ventilation, it is necessary to know the
people normally present in a certain environment multiplied pressure drop given by the system. A ventilation system
by the fresh airflow rate recommended by local norms (every is composed by various elements (ducting, bends, filters,
country has normally its own rules).Generally, the recom- grilles etc.) and has a static pressure drop given the sum of
mended fresh air flow rate is between 20 and 30 m³/h per each elements resistance.
person, increased by 10-20 m³/h in case smoke is allowed.
The calculation of the system pressure drop is essential for
* HEAT QUANTITY TO BE EXTRACTED FROM A CERTAIN a correct design and for a correct fan selection. Please refer
ENVIRONMENT to specialized publications, dedicated software or specialist
consultancy.

P 3600
Q= * (6.1)
ρ*cp*∆T
where:
Q = flow rate in m³/h
P = heat to be extracted in kW
ρ = air density in kg/m³
∆T = temperature difference between air intake and outlet in °C
cp = air specific heat capacity ( 1)

8
Environment Air changes Halls 6÷20
Chicken Farm 8÷15 Milk (working) 15
Cattle Farm 15÷25 Cleaners - Dyers 20÷30
Hotel Halls 4 Boiler Houses (engine rooms) 20÷30
Garage (parking) 8 Warehouses for perishable goods 15
Garage (repairing) 10÷20 Warehouses for non perishable goods 5
Lavatories - Showers 6 Tobacco Processing 12
Galvanic Bath 25÷30 Canteens 4÷6
Banks 4 Motors (engine rooms) 5÷10
Cafes - Pubs 10 Mills 15÷30
Carpentry 10÷12 Shops 5
Paper Hill 15÷20 Work Shops 6÷10
Heating Plants 50÷60 Hospitals 6
Churches 10÷15 Gymnasium 10÷20
Cinemas / Theaters 10÷15 Swimming Pools 20÷30
Dyers 15÷20 Pump Rooms 6÷12
Tannery (drying) 35 Restaurant (kitchens) 20÷40
Tannery (working) 18 Restaurant (rooms) 12
Chromium Plating Plants 6÷10 Environment
Rubber Factories 10÷20 Waiting Rooms 10
Bakeries 6÷10 Dancing Halls 8÷16
Chemical Factories 15÷20 Casino 10÷20
Environment Meeting Rooms 6÷8
Factories (general) 6÷10 Meeting Halls 10÷20
Woodworks 6÷15 Schools 6
Textile - Factories 5 Dusty Plants 10÷20
Foundries 20÷30 Plants Metallurgic 5÷10
Bread Oven 20÷30 Supermarket 5÷10
Electric Ovens 30 Typography 15÷25
Industrial Ovens 20 Toilet 30
Furnace Rooms 20÷30 Transformer Rooms 12÷30
Mushroom Bed 10÷20 Technical Rooms 15

7 CONVERSION FACTORS
AIRFLOW
Multiply for to have Multiply for to have Multiply for to have
60 m3/min 0,0003 m3/s 0,000016 m3/s
3600 m3/h 0,0167 m3/min 0,001 m3/min
m3/s 1000 l/s m3/h 0,2778 l/s l/min 0,06 m3/h
60000 l/min 16,667 l/min 0,0167 l/s
2118,9 CFM 0,58858 CFM 0,03531 CFM
0,0167 m3/s 0,001 m3/s 0,0004719 m3/s
60 m3/h 0,06 m3/min 0,02832 m3/min
m3/min 16,667 l/s l/s 3,6 m3/h CFM 1,699 m3/h
1000 l/min 60 l/min 0,47195 l/s
35,315 CFM 2,1189 CFM 28,317 l/min

PRESSURE
Multiply for to have Multiply for to have Multiply for to have
1 mmH2O 0,10215 kgf/m2 25,4 kgf/m2
0,07343 mmHg 0,10215 mmH2O 25,4 mmH2O
9,7898 Pa 0,007501 mmHg 1,8651 mmHg
kg/m2 0,0000966 Atm Pa 0,0000099 Atm in-wg 248,66 Pa
0,00142 psi 0,000145 psi 0,002454 Atm
0,03937 in-wg 0,004022 in-wg 0,03607 psi
0,002891 in-Hg 0,0002953 in-Hg 0,07343 in-Hg
1 kgf/m2 10350 kgf/m2 345,91 kgf/m2
0,07343 mmHg 10350 mmH2O 345,91 mmH2O
9,7898 Pa 760 mmHg 25,4 mmHg
mmH2O 0,0000966 Atm Atm 101300 Pa in-Hg 3386,4 Pa
0,00142 psi 14,696 psi 0,03342 Atm
0,03937 in-wg 407,48 in-wg 0,49115 psi
0,002891 in-Hg 29,921 in-Hg 13,619 in-wg
13,619 kgf/m2 704,28 kgf/m2
13,619 mmH2O 704,28 mmH2O
133,32 Pa 51,715 mmHg
mmHg 0,001316 Atm psi 6894,8 Pa
0,01934 psi 0,06805 Atm
0,53616 in-wg 27,728 in-wg
0,03937 in-Hg 2,036 in-Hg

9
AIRFLOW
Multiply for to have Multiply for to have Multiply for to have
60 m/min 0,0254 m/s 0,00508 m/s
39,37 in/sec 1,524 m/min 0,3048 m/mm
m/s in/sec fpm
3,2808 fps 0,0833 fps 0,2 in/sec
196,85 fpm 5 fpm 0,0167 fps
0,0167 m/s 0,3048 m/s
0,65617 in/sec 18,288 m/min
m/min fps
0,05468 fps 12 in/sec
3,2808 fpm 60 fpm

DENSITY
Multiply for to have Multiply for to have Multiply for to have
kg/m3 0,06243 Ib/ft3 Ib/ft3 16,02 kg/m3

8 INSTALLATION TIPS Such distance is generally equal to 2,5 times the duct diameter,
for an average air speed lower than 12,5 m/s (in case of rectan-
gular duct use, equivalent diameter). Above such air speed val-
During design and installation of a ventilation system, there are ue, it is necessary to add one diameter for each 5 m/s increase.
some tricks that reduce the creation of turbulence. Turbulences
unavoidably result in performance reduction, compared to what
is mentioned in the Catalogue (that is the result of laboratory
test, made in ideal conditions according to precise reference
norms) and an increase of noise emission.
Find below a selection of these tips.
Before installing a “disturbing” element in the ducting (bend,
split element, filter etc.), it is necessary to foresee, between
the fan outlet and such element, a distance that allows the
airflow to achieve a regular speed profile (see picture below).

Introduzione Tecnica

Technical Introduction

* In case of an axial fan installation with free inlet (not duct-


ed), it is opportune to foresee a bell inlet cone.

Air passage area


at the casing tapering
Casing Outlet Ducting
tapering area at outlet

25% NOT RECOMMENDED RECOMMENDED

50%

75%
* In case of fan installation with anti-vibration joint, it is op-
Centrifugal fan 100% of the lenght of the ducting necessary
to have a regular air flow profile
portune that the same is installed reasonably tight.

Axial fan

NOT RECOMMENDED RECOMMENDED

10
* During installation, it is opportune that ducting doesn’t have a
bend as such to create air whirls at fan inlet.

NOT RECOMMENDED RECOMMENDED NOT RECOMMENDED RECOMMENDED

* During installation, it is opportune that ducting is well aligned * It is opportune that eventual bends close to the fan inlet have
with fan inlet (and outlet). air rectifiers.

NOT RECOMMENDED RECOMMENDED NOT RECOMMENDED RECOMMENDED

* Eventual duct diameter changes, especially if close to fan * If it is necessary to install setting shutters along the duct, it
inlet. must be smooth, possibly with small angle. is preferable to use shutters with opposite blades to reduce
creation of whirls and turbulence.

NOT RECOMMENDED RECOMMENDED NOT RECOMMENDED RECOMMENDED

* If it is necessary to install a bend close to fan outlet, it is


necessary for the bend to be smooth and with air rectifiers.
9 CONCLUSIONS

This section of the present catalogue has a divulgative purpose.


Dynair cannot be held responsible in case of possible inaccura-
cies, errors and/or omissions.
According to our policy of continuous development, all data
included in Dynair catalogue can be modified without prior or
successive notice.
Dynair remains at your disposal for consultancies, fan selections
and offers.

NOT RECOMMENDED RECOMMENDED

11
1
part

ROOF FANS

Centrifugal Roof Fan


FCS Pg. 15
sez.
Roof Exhaust Downblast
LISTED

1
FCVS Pg. 33
Roof Exhaust Upblast
LISTED

DRF Pg. 51
Centrifugal Roof Fan

13
FCS
Roof Exhaust Downblast

GENERAL DESCRIPTION
FCS -D (Direct drive) and FCS-B (Belt drive) fans are ideal for general purpose exhaust ap-
plications including bathrooms, garages, general kitchen areas, offices, churches, dormitories,
factories, large warehouses and other relatively clean air applications.

They feature a weather-resistant, seamless spun aluminum housing which works in conjunction
with special wheel design and deeply spun inlets to provide smooth and quiet airflow through
the ventilator.

Wheels are backward inclined centrifugal curved for higher efficiency and quieter operation.

CONSTRUCTION (DIRECT DRIVE)


• Base frame made from sheet steel in HDG.
• Backward curved wheel in aluminum / cold rolled sheet steel.
• Motor: Asynchronous single / three-phase TEFC motor manufactured according to IEC
standard. Suitable for 60 Hz supply.

CONSTRUCTION (BELT DRIVE)


• Belts and Drives: Belts shall be oil and heat resistant. Drives shall be precision machined
cast iron type, keyed and securely attached to the wheel and motor shafts.
• Self-Aligning Bearings: Heavy-duty bearings are sized for a minimum L50 life in excess of
200,000 hours of operation. 100% factory tested, they are designed for air handling
applications.

LISTED ACCESSORIES
• Gravity shutter
• On/ Off switch
• Liquidtight conduit

Maico Gulf certifies that the DYNAIR model FCS are


licensed to bear the AMCA Seal. The ratings shown
are based on tests and procedures performed in
accordance with AMCA Publication 211 and AMCA
Publication 311 and comply with the requirements
of the AMCA Certified Ratings Program. Perfor-
mance certified is for installation type C – Ducted
inlet, Free outlet. Power rating (watts, kW, or BHP)
includes transmission losses. Performance ratings
do not include the effects of appurtenances (acces-
sories).

15
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
Selection - FCS 300 D FCS 300 D

sez. 500

1
400

300
Psta (Pa)

200

100

0
0.3
Pabs (kW)

0.2

0.1

0.0
80
Tot. Eff. (%)

60
40
20
0
0 500 1000 1500 2000 2500 3000
Q - Volume Flow (m³/h)

Technical data

FCS 300 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
2624 460 55/F 66 -20 / 82 0.37 2.7 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

16
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCS 355 D
Selection - FCS 355 D

700 sez.

600
1
500

400
Psta (Pa)

300

200

100

0
0.6
Pabs (kW)

0.4

0.2

0.0
80
Tot. Eff. (%)

60
40
20
0
0 1000 2000 3000 4000 5000
Q - Volume Flow (m³/h)

Technical data

FCS 355 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
4071 600 55/F 62 -20 / 82 0.55 4 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

17
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCS 400 D
Selection - FCS 400 D

sez. 800

1 700

600

500
Psta (Pa)

400

300

200

100

0
1.5
Pabs (kW)

1.0

0.5

0.0
80
Tot. Eff. (%)

60
40
20
0
0 1000 2000 3000 4000 5000 6000 7000
Q - Volume Flow (m³/h)

Technical data

FCS 400 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
5770 750 55/F 66 -20 / 82 1.1 6.1 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

18
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCS 450 D
Selection - FCS 450 D

1000 sez.

900 1
800

700

600
Psta (Pa)

500

400

300

200

100

0
1.5
Pabs (kW)

1.0

0.5

0.0
80
Tot. Eff. (%)

60
40
20
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
Q - Volume Flow (m³/h)

Technical data

FCS 450 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
8179 920 55/F 75 -20 / 82 2.2 4.08 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

19
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCS 500 D

Selection - FCS 500 D

sez. 1400

1 1200

1000

800
Psta (Pa)

600

400

200

0
3
Pabs (kW)

0
80
Tot. Eff. (%)

60
40
20
0
0 2000 4000 6000 8000 10000 12000 14000
Q - Volume Flow (m³/h)

Technical data

FCS 500 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
11113 1150 55/F 78 -20 / 82 3.7 6.8 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

20
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCS 630 D
Selection - FCS 630 D

800 sez.

700
1
600

500
Psta (Pa)

400

300

200

100

0
3
Pabs (kW)

0
80
Tot. Eff. (%)

60
40
20
0
0 2000 4000 6000 8000 10000 12000 14000 16000 18000
Q - Volume Flow (m³/h)

Technical data

FCS 630 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
14641 730 55/F 68 -20 / 82 3 7.3 1150 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

21
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCS 710 D
Selection - FCS 710 D

sez. 1000

1 900

800

700

600
Psta (Pa)

500

400

300

200

100

0
6
Pabs (kW)

0
80
Tot. Eff. (%)

60
40
20
0
0 5000 10000 15000 20000 25000
Q - Volume Flow (m³/h)

Technical data

FCS 710 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
21704 930 55/F 73 -20 / 82 5.5 10.6 1150 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

22
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCS 800 D

Selection - FCS 800 D


1400 sez.

1200
1
1000

800
Psta (Pa)

600

400

200

0
8
6
Pabs (kW)

4
2
0
80
Tot. Eff. (%)

60
40
20
0
0 5000 10000 15000 20000 25000 30000 35000
Q - Volume Flow (m³/h)

Technical data

FCS 800 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
30510 1200 55/F 78 -20 / 82 7.5 18.2 1150 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

23
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCS 300 B
FEG75
p = 1.2kg/m3

sez.

1
40% 50% 62% 60% 50% 40% 30%
0.2
500

0.1

300

200

100
0.017 60dB(A)
70

Speed N (rpm)
Pt (Pa)

50 80dB(A) 1800
1700
1600
1500
30 75dB(A)
1400

1300

20 1200
70dB(A)
1100

1000
65dB(A)
900
10
800

0.1 0.2 0.3 0.5 0.7 1 2 3 Q (m3/s)

Q (m3/h)
200 300 500 1,000 2,000 3,000 5,000 10,000

V (m/s)
1 2 3 5 10 20 30

PV (Pa)
0.5 1 5 10 50 100 500

Pv = (V/1.3)²

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
FCS 300 B
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

24
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCS 355 B
FEG71
p = 1.2kg/m3

sez.

1
40% 50% 60% 63.8% 60% 50% 40% 30%
0.4
0.3
700

0.2
500

0.1
300

200

0.028

Speed N (rpm)
100
Pt (Pa)

70 85dB(A) 2000

50
65dB(A) 1800

80dB(A) 1600

1400
30
75dB(A)
1200
20
70dB(A)
1000

10 800

0.1 0.2 0.3 0.5 0.7 1 2 3 Q (m3/s)

Q (m3/h)
300 500 1,000 2,000 3,000 5,000 10,000

V (m/s)
1 2 3 5 10 20 30

Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²

• Performance certified is for installation type C - ducted inlet, free outlet. FCS
Power355 B
rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

25
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCS 400 B
FEG63
p = 1.2kg/m3

sez.

1 1,000 0.6
0.8
40% 50% 58.2% 50% 40% 30%

0.4
700
0.3
500
0.2

300 0.1

200

0.052

Speed N (rpm)
Pt (Pa)

100

70dB(A) 90dB(A) 2000


70
1800

50 85dB(A) 1600

1400

30 80dB(A)
1200

20 75dB(A) 1000

800

10

7
0.1 0.2 0.3 0.5 0.7 1 2 3 5 Q (m3/s)

Q (m3/h)
500 1,000 2,000 3,000 5,000 10,000 20,000

V (m/s)
1 2 3 5 10 20 30

Pv (Pa)
0.5 1 5 10 50 100 500

Pv = (V/1.3)²

• Performance certified is for installation type C - ducted inlet,FCS 400 BPower rating(watts, kW, or BHP) does not include transmission losses.
free outlet.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

26
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCS 450 B
FEG67
p = 1.2kg/m3

sez.

1
40% 50% 62.7% 60% 50% 40% 30%
1 1.5
1,000
0.8
0.6
700 0.4
0.3
500
0.2

300
0.1

200

65dB(A)
0.061

Speed N (rpm)
Pt (Pa)

100
90dB(A) 1900

70 1750
1700

50
85dB(A) 1500

1300

80dB(A)
30
1100

20 75dB(A)
900

70dB(A)
700
10

0.2 0.3 0.5 0.7 1 2 3 5 7 Q (m3/s)

Q (m3/h)
500 1,000 2,000 3,000 5,000 10,000 20,000 30,000

V (m/s)
1 2 3 5 10 20 30

Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²

FCS 450 B
• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

27
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCS 500 B
FEG71
p = 1.2kg/m3

sez.

1
40% 50% 60% 67.6% 60% 50% 40%
1.5 2
1
1,000 0.8
0.6
700
0.4
500 0.3

0.2
300

200

65dB(A)

Speed N (rpm)
0.059
Pt (Pa)

100 1800

1600
90dB(A)
70
1400

50 85dB(A) 1200

30 80dB(A) 1000

70dB(A)
20 75dB(A) 800

600
10

0.2 0.3 0.5 0.7 1 2 3 5 7 10 Q (m3/s)

Q (m3/h)
1,000 2,000 3,000 5,000 10,000 20,000 30,000

V (m/s)
1 2 3 5 10 20 30 50

Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²

FCS 500 B
• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

28
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCS 630 B
FEG63
p = 1.2kg/m3

sez.

3
40%
4
50% 59.9% 50% 40% 30%
1
2
1,000 1.5
1
700 0.8
0.6
500
0.4
0.3
300
0.2
200
0.1

1500
100
90dB(A) 1300

Speed N (rpm)
70
1100
85dB(A)
Pt (Pa)

50 0.033
55dB(A) 900
80dB(A)
30
700
20 75dB(A)

70dB(A)
500
10
65dB(A)
7

5 60dB(A)
300

1
0.2 0.3 0.5 0.7 1 2 3 5 7 10 Q (m3/s)
0.7
Q (m3/h)
0.5 1,000 2,000 3,000 5,000 10,000 20,000 30,000 50,000

V (m/s)
0.3 0.5 1 2 3 5 10 20 30

0.2 Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²
0.1

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation TypeFCS 630 inlet,
C: ducted B free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

29
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCS 710 B
FEG67
p = 1.2kg/m3

sez.

1
40% 50% 60% 63.9% 60% 50% 40%
3
1,000 2
1.5
700
1
0.8
500
0.6
0.4
300 0.3
0.2
200

0.1

100
1200

70 90dB(A) 1100

Speed N (rpm)
1000
0.047
50 900
Pt (Pa)

85dB(A)
60dB(A) 800

30 700
80dB(A)
20 600
75dB(A)
500

70dB(A)
10
400

7 65dB(A)
5 300

1
0.3 0.5 0.7 1 2 3 5 7 10 20 Q (m3/s)
0.7
Q (m3/h)
0.5 1,000 2,000 3,000 5,000 10,000 20,000 30,000 50,000

V (m/s)
0.30.5 1 2 3 5 10 20 30 50

Pv (Pa)
0.2
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²
0.1

• Performance certified is for installation type C - ducted inlet, freeFCS 710


outlet. B rating(watts, kW, or BHP) does not include transmission losses.
Power
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

30
PERFORMANCE FCS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCS 800 B

FEG71
p = 1.2kg/m3

sez.

1
40% 50% 60% 67.9% 60% 50% 40%
5 6
4
3
1,000
2
700 1.5

1
500
0.8
0.6

300 0.4
0.3
200

Speed N (rpm)
0.19
Pt (Pa)

1200
100 1100
95dB(A)
1000
70
900

50
90dB(A) 800

700
85dB(A)
30
75dB(A) 600

20
80dB(A)
500

400

10

0.5 0.7 1 2 3 5 7 10 20 30 Q (m3/s)

Q (m3/h)
2,000 3,000 5,000 10,000 20,000 30,000 50,000 100,000

V (m/s)
1 2 3 5 10 20 30 50

Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for FCS 800dBA
LwA only. B levels are not licensed by AMCA International.

31
DIMENSIONS FCS

sez. Models FCS - D

1 Model No
FCS 300
A
534
B
650
C(sq)
600
D
40
Weight (Kg)
21
FCS 355 580 720 660 40 28
FCS 400 636 780 700 40 34
FCS 450 689 840 780 40 43
FCS 500 765 930 830 40 54
FCS 630 977 1080 950 40 63
FCS 710 1195 1200 1100 40 75
FCS 800 1332 1438 1160 50 87
C(sq)
All dimension’s are in ‘mm’
*Approximate weight without motor.

Models FCS - B

Model No A B C(sq) D Weight (Kg)*


FCS 300 685 680 600 40 38
FCS 355 702 720 660 40 44
FCS 400 718 780 700 40 52
FCS 450 774 830 780 40 69
FCS 500 882 940 830 40 86
FCS 630 1047 1080 950 40 124
FCS 710 1265 1200 1100 40 186
FCS 800 1402 1438 1160 50 269
FCS 900^ 1524 1608 1370 50 332
FCS 1000^ 1600 1780 1410 50 390

All dimension’s are in ‘mm’.


C(sq) *Approximate weight without motor.
^Performance upon request.

32
FCVS
Roof Exhaust Upblast

GENERAL DESCRIPTION
FCVS -D (Direct drive) and FCVS-B (Belt drive) fans are ideal for general purpose exhaust ap- sez.
plications including bathrooms, garages, general kitchen areas, offices, churches, dormitories,
factories, large warehouses and other relatively clean air applications. 1
They feature a weather-resistant, seamless spun aluminum housing which works in conjunc-
tion with special wheel design and deeply spun inlets to provide smooth and quiet airflow
through the ventilator.

Wheels are backward inclined centrifugal curved for higher efficiency and quieter operation.

Certified performance in accordance with AMCA 210 and 300.

CONSTRUCTION (DIRECT DRIVE)


• Base frame made from sheet steel in HDG.
• Backward curved wheel in aluminum / cold rolled sheet steel.
• Motor: Asynchronous single / three-phase TEFC motor manufactured according to IEC stan -
dard. Suitable for 60 Hz supply.

CONSTRUCTION (BELT DRIVE)


• Belts and Drives: Belts shall be oil and heat resistant. Drives shall be precision machined
cast iron type, keyed and securely attached to the wheel and motor shafts.
• Self-Aligning Bearings: Heavy-duty bearings are sized for a minimum L50 life in excess of
200,000 hours of operation. 100% factory tested, they are designed for air handling applica-
LISTED tions.

ACCESSORIES (UPON REQUEST)


• Gravity shutter
• On/Off switch
• Liquidtight conduit
• Grease collector

Maico Gulf certifies that the DYNAIR model FCVS are


licensed to bear the AMCA Seal. The ratings shown
are based on tests and procedures performed in
accordance with AMCA Publication 211 and AMCA
Publication 311 and comply with the requirements
of the AMCA Certified Ratings Program. Perfor-
mance certified is for installation type C – Ducted
inlet, Free outlet. Power rating (watts, kW, or BHP)
includes transmission losses. Performance ratings
do not include the effects of appurtenances (acces-
sories).

33
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
Selection - FCS 300 D FCVS 300 D

sez. 500

1
400

300
Psta (Pa)

200

100

0
0.3
Pabs (kW)

0.2

0.1

0.0
80
Tot. Eff. (%)

60
40
20
0
0 500 1000 1500 2000 2500 3000
Q - Volume Flow (m³/h)

Technical data

FCVS 300 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
2624 460 55/F 66 -20 / 82 0.37 2.7 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

34
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCVS 355 D
Selection - FCS 355 D

700 sez.

600
1
500

400
Psta (Pa)

300

200

100

0
0.6
Pabs (kW)

0.4

0.2

0.0
80
Tot. Eff. (%)

60
40
20
0
0 1000 2000 3000 4000 5000
Q - Volume Flow (m³/h)

Technical data

FCVS 355 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
4071 600 55/F 62 -20 / 82 0.55 4 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

35
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCVS 400 D
Selection - FCS 400 D

sez. 800

1 700

600

500
Psta (Pa)

400

300

200

100

0
1.5
Pabs (kW)

1.0

0.5

0.0
80
Tot. Eff. (%)

60
40
20
0
0 1000 2000 3000 4000 5000 6000 7000
Q - Volume Flow (m³/h)

Technical data

FCVS 400 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
5770 750 55/F 66 -20 / 82 1.1 6.1 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

36
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCVS 450 D
Selection - FCS 450 D

1000 sez.

900 1
800

700

600
Psta (Pa)

500

400

300

200

100

0
1.5
Pabs (kW)

1.0

0.5

0.0
80
Tot. Eff. (%)

60
40
20
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
Q - Volume Flow (m³/h)

Technical data

FCVS 450 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
8179 920 55/F 75 -20 / 82 2.2 4.08 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

37
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCVS 500 D

Selection - FCS 500 D

sez. 1400

1 1200

1000

800
Psta (Pa)

600

400

200

0
3
Pabs (kW)

0
80
Tot. Eff. (%)

60
40
20
0
0 2000 4000 6000 8000 10000 12000 14000
Q - Volume Flow (m³/h)

Technical data

FCVS 500 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
11113 1150 55/F 78 -20 / 82 3.7 6.8 1750 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

38
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCVS 630 D
Selection - FCS 630 D

800 sez.

700
1
600

500
Psta (Pa)

400

300

200

100

0
3
Pabs (kW)

0
80
Tot. Eff. (%)

60
40
20
0
0 2000 4000 6000 8000 10000 12000 14000 16000 18000
Q - Volume Flow (m³/h)

Technical data

FCVS 630 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
14641 730 55/F 68 -20 / 82 3 7.3 1150 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

39
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCVS 710 D
Selection - FCS 710 D

sez. 1000

1 900

800

700

600
Psta (Pa)

500

400

300

200

100

0
6
Pabs (kW)

0
80
Tot. Eff. (%)

60
40
20
0
0 5000 10000 15000 20000 25000
Q - Volume Flow (m³/h)

Technical data

FCVS 710 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
21704 930 55/F 73 -20 / 82 5.5 10.6 1150 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

40
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

DIRECT DRIVE
FCVS 800 D

Selection - FCS 800 D


1400 sez.

1200
1
1000

800
Psta (Pa)

600

400

200

0
8
6
Pabs (kW)

4
2
0
80
Tot. Eff. (%)

60
40
20
0
0 5000 10000 15000 20000 25000 30000 35000
Q - Volume Flow (m³/h)

Technical data

FCVS 800 D
Air Flow Pressure IP/CL Sound Operating Temp Rated Power Max. Current Nominal Speed
Power Supply
m3/h Pa dB(A) Min/Max (°C) kW A RPM
30510 1200 55/F 78 -20 / 82 7.5 18.2 1150 380V/ 3 Ph/ 60Hz

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

41
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCVS 300 B
FEG75
p = 1.2kg/m3

sez.

1 0.2
40% 50% 62% 60% 50% 40% 30%

500

0.1

300

200

100
0.017 60dB(A)
70

Speed N (rpm)
Pt (Pa)

50 80dB(A) 1800
1700
1600
1500
30 75dB(A)
1400

1300

20 1200
70dB(A)
1100

1000

65dB(A)
900
10
800

0.1 0.2 0.3 0.5 0.7 1 2 3 Q (m3/s)

Q (m3/h)
200 300 500 1,000 2,000 3,000 5,000 10,000

V (m/s)
1 2 3 5 10 20 30

PV (Pa)
0.5 1 5 10 50 100 500

Pv = (V/1.3)²

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.
FCS 300 B

42
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCVS 355 B
FEG71
p = 1.2kg/m3

sez.

0.4
40% 50% 60% 63.8% 60% 50% 40% 30%
1
0.3
700

0.2
500

0.1
300

200

0.028

Speed N (rpm)
100
Pt (Pa)

70 85dB(A) 2000

50
65dB(A) 1800

80dB(A) 1600

1400
30
75dB(A)
1200
20
70dB(A)
1000

10 800

0.1 0.2 0.3 0.5 0.7 1 2 3 Q (m3/s)

Q (m3/h)
300 500 1,000 2,000 3,000 5,000 10,000

V (m/s)
1 2 3 5 10 20 30

Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
FCS 355
Performance ratings do not include the effects of appurtenances B
(accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

43
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCVS 400 B
FEG63
p = 1.2kg/m3

sez.

1 0.8
40% 50% 58.2% 50% 40% 30%

1,000 0.6

0.4
700
0.3
500
0.2

300 0.1

200

0.052

Speed N (rpm)
Pt (Pa)

100

70dB(A) 90dB(A) 2000


70
1800

50 85dB(A) 1600

1400

30 80dB(A)
1200

20 75dB(A) 1000

800

10

7
0.1 0.2 0.3 0.5 0.7 1 2 3 5 Q (m3/s)

Q (m3/h)
500 1,000 2,000 3,000 5,000 10,000 20,000

V (m/s)
1 2 3 5 10 20 30

Pv (Pa)
0.5 1 5 10 50 100 500

Pv = (V/1.3)²
• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
FCS 400 B
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

44
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCVS 450 B
FEG67
p = 1.2kg/m3

sez.

1
40% 50%
1.5
62.7% 60% 50% 40% 30%
1
1,000
0.8
0.6
700 0.4
0.3
500
0.2

300
0.1

200

65dB(A)
0.061

Speed N (rpm)
Pt (Pa)

100
90dB(A) 1900

70 1750
1700

50
85dB(A) 1500

1300

80dB(A)
30
1100

20 75dB(A)
900

70dB(A)
700
10

0.2 0.3 0.5 0.7 1 2 3 5 7 Q (m3/s)

Q (m3/h)
500 1,000 2,000 3,000 5,000 10,000 20,000 30,000

V (m/s)
1 2 3 5 10 20 30

Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²

FCS 450 B
• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

45
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCVS 500 B
FEG71
p = 1.2kg/m3

sez.

1 40%
1.5
50%
2
60% 67.6% 60% 50% 40%

1
1,000 0.8
0.6
700
0.4
500 0.3

0.2
300

200

65dB(A)

Speed N (rpm)
0.059
Pt (Pa)

100 1800

1600
90dB(A)
70
1400

50 85dB(A) 1200

30 80dB(A) 1000

70dB(A)
20 75dB(A) 800

600
10

0.2 0.3 0.5 0.7 1 2 3 5 7 10 Q (m3/s)

Q (m3/h)
1,000 2,000 3,000 5,000 10,000 20,000 30,000

V (m/s)
1 2 3 5 10 20 30 50

Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²

FCS 500 B
• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

46
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCVS 630 B
FEG63
p = 1.2kg/m3

sez.

3
40%
4
50% 59.9% 50% 40% 30%
1
2
1,000 1.5
1
700 0.8
0.6
500
0.4
0.3
300
0.2
200
0.1

1500
100
90dB(A) 1300

Speed N (rpm)
70
1100
85dB(A)
Pt (Pa)

50 0.033
55dB(A) 900
80dB(A)
30
700
20 75dB(A)

70dB(A)
500
10
65dB(A)
7

5 60dB(A)
300

1
0.2 0.3 0.5 0.7 1 2 3 5 7 10 Q (m3/s)
0.7
Q (m3/h)
0.5 1,000 2,000 3,000 5,000 10,000 20,000 30,000 50,000

V (m/s)
0.3 0.5 1 2 3 5 10 20 30

0.2 Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²
0.1

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
FCS 630
• Values shown are for outlet LwoA sound power levels for: Installation Type B
C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

47
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCVS 710 B
FEG67
p = 1.2kg/m3

sez.

1 2
3
40% 50% 60% 63.9% 60% 50% 40%

1,000
1.5
700
1
0.8
500
0.6
0.4
300 0.3
0.2
200

0.1

100
1200

70 90dB(A) 1100

Speed N (rpm)
1000
0.047
50 900
Pt (Pa)

85dB(A)
60dB(A) 800

30 700
80dB(A)
20 600
75dB(A)
500

70dB(A)
10
400

7 65dB(A)
5 300

1
0.3 0.5 0.7 1 2 3 5 7 10 20 Q (m3/s)
0.7
Q (m3/h)
0.5 1,000 2,000 3,000 5,000 10,000 20,000 30,000 50,000

V (m/s)
0.30.5 1 2 3 5 10 20 30 50

Pv (Pa)
0.2
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²
0.1

• Performance certified is for installation type C - ducted inlet, free outlet.FCS 710
Power B
rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
calculated per AMCA International Standard 301. The values are certified for LwA only. dBA levels are not licensed by AMCA International.

48
PERFORMANCE FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

BELT DRIVE
FCVS 800 B
FEG71
p = 1.2kg/m3

sez.

1
40% 50% 60% 67.9% 60% 50% 40%
5 6
4
3
1,000
2
700 1.5

1
500
0.8
0.6

300 0.4
0.3
200

Speed N (rpm)
0.19
Pt (Pa)

1200
100 1100
95dB(A)
1000
70
900

50
90dB(A) 800

700
85dB(A)
30
75dB(A) 600

20
80dB(A)
500

400

10

0.5 0.7 1 2 3 5 7 10 20 30 Q (m3/s)

Q (m3/h)
2,000 3,000 5,000 10,000 20,000 30,000 50,000 100,000

V (m/s)
1 2 3 5 10 20 30 50

Pv (Pa)
0.5 1 5 10 50 100 500 1,000

Pv = (V/1.3)²

• Performance certified is for installation type C - ducted inlet, free outlet. Power rating(watts, kW, or BHP) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
• Values shown are for outlet LwoA sound power levels for: Installation Type C: ducted inlet, free outlet. The A-weighted sound ratings shown have been
FCS 800
calculated per AMCA International Standard 301. The values are certified B only. dBA levels are not licensed by AMCA International.
for LwA

49
DIMENSIONS FCVS

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

Models FCVS- D

sez.
Model No A B C(sq) D Weight (Kg)*

1 FCVS 300
FCVS 355
FCVS 400
559
575
609
710
780
850
600
660
700
40
40
40
31
39
52
FCVS 450 741 980 780 40 66
FCVS 500 765 1050 830 40 85
FCVS 630 971 1190 950 40 98
FCVS 710 1188 1350 1100 40 114
FCVS 800 1322 1484 1160 50 132

All dimension’s are in ‘mm’.


*Approximate weight without motor.

C(sq)

C(sq)

Models FCVS- B

Model No A B C(sq) D Weight (Kg)*


FCVS 300 664 710 600 40 42
FCVS 355 679 780 660 40 49
FCVS 400 688 850 700 40 57
FCVS 450 821 980 780 40 75
FCVS 500 872 1050 830 40 94
FCVS 630 1041 1190 950 40 136
FCVS 710 1258 1350 1100 40 204
FCVS 800 1392 1484 1160 50 295
C(sq) FCVS 900^ 1515 1650 1370 50 365
FCVS 1000^ 1593 1700 1410 50 429

All dimension’s are in ‘mm’.


*Approximate weight without motor.
^Performance upon request.

C(sq)

50
DRF
Centrifugal Roof Fan

GENERAL DESCRIPTION
DRF is a versatile and robust range of centrifugal roof extract unit that is available in 6 sizes and
suitable for vertical and horizontal installation. Highly resistant protection cowl in aluminum is sez.
perfectly adapted for exposed areas. DRF is a compact design model and ease of installation
is made to satisfy the requirements of efficient ventilation in residential, commercial and light
industrial applications.
1
INSTALLATION
• Compact centrifugal roof fan for free or ducted application.
• Horizontal and vertical installation.
• Can be mounted on an exterior wall when roof access is not available.
• Easy solution for a multipoint ventilation need.
• Added benefits of the outdoor installation: free interior space, maximised ventilation and
noiseless operation.

MOTOR SPECIFICATION
• Ball bearing motor, permanently lubricated for maintenance -free operation and continuous
operation.
• Fan and motor assembly balanced for a quiet and vibration-free operation.
• Motor is IP44 protected.

PRODUCT SPECIFICATION
• Available in 6 sizes with performances rating from 240 m³/h to 1430 m³/h (20 to 680 Pa).
• Suitable for clean air temperature from – 10°C up to +60°C.
• Cowl in highly resistant aluminum.
• The cowl is removable for access to the motor and wiring connections.
• Self-cleaning backward bladed impeller with high efficiency and low noise level.
• Protection guard is electroplated.
• Speed controllable.
• CE marked.
• Comply with EN 60335-2-80, B.T. 2006/95/CE,EMC 2004/108/CE.

ACCESSORIES
• Speed regulators.

APPLICATIONS

AIRFLOW

FILTERS

FILTE

51
PERFORMANCE DRF

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

400

350

300 DRF 100


sez. Air Flow Pressure IP/CL Sound Operating Temp

1
250

m3/h Pa dB(A) Min/Max (°C)


Psta (Pa)

200 220 350 44/F 42 -30 / 60

150

100
Rated Power Max. Current Nominal Speed Capacitor Power Supply

50 W A RPM uF
61 0.3 2509 3 220-240 V/1 Ph /60hz
0
0 50 100 150 200 250
Q-Volume Flow (m³/h)

400

DRF 125
300
Air Flow Pressure IP/CL Sound Operating Temp

m3/h Pa dB(A) Min/Max (°C)


310 370 44/F 44 -30 / 60
Psta (Pa)

200

Rated Power Max. Current Nominal Speed Capacitor Power Supply


100
W A RPM uF
62 0.31 2318 3 220-240 V/1 Ph /60Hz

0
0 50 100 150 200 250 300 350
Q-Volume Flow (m³/h)

600

500
DRF 150
Air Flow Pressure IP/CL Sound Operating Temp
400
m3/h Pa dB(A) Min/Max (°C)
560 500 44/F 51 -30 / 60
Psta (Pa)

300

200

Rated Power Max. Current Nominal Speed Capacitor Power Supply

W A RPM uF
100
119 0.5 2477 3 220-240 V/1 Ph /60Hz

0
0 100 200 300 400 500 600 700
Q-Volume Flow (m³/h)

52
PERFORMANCE DRF

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

500

400
DRF 200
Air Flow Pressure IP/CL Sound Operating Temp sez.
300
m3/h Pa dB(A) Min/Max (°C)
1
Psta (Pa)

800 440 44/F 46 -30 / 60

200

Rated Power Max. Current Nominal Speed Capacitor Power Supply


100

W A RPM uF
252 1.01 2763 5 220-240 V/1 Ph /60Hz

0
0 100 200 300 400 500 600 700 800 900
Q-Volume Flow (m³/h)

500

400
DRF 250
Air Flow Pressure IP/CL Sound Operating Temp
300
m3/h Pa dB(A) Min/Max (°C)
Psta (Pa)

900 450 44/F 45 -30 / 60

200

Rated Power Max. Current Nominal Speed Capacitor Power Supply


100
W A RPM uF
251 0.99 2616 5 220-240 V/1 Ph /60Hz

0
0 100 200 300 400 500 600 700 800 900 1000
Q-Volume Flow (m³/h)

500

400

DRF 315
Air Flow Pressure IP/CL Sound Operating Temp
300
m3/h Pa dB(A) Min/Max (°C)
Psta (Pa)

1100 440 44/F 58 -30 / 60

200

Rated Power Max. Current Nominal Speed Capacitor Power Supply


100

W A RPM uF
304 1.22 2665 7 220-240 V/1 Ph /60Hz
0
0 200 400 600 800 1000 1200 1400
Q-Volume Flow (m³/h)

53
DIMENSIONS DRF

D2

sez.

H
D1

DIMENSIONS (mm)
MODEL D1 D2 H
DRF 100 98 333 225
DRF 125 125 333 225
DRF 150 147 405 266
DRF 200 198 405 266
DRF 250 247 405 266
DRF 315 315 484 322

Curb DIMENSIONS (mm)


MODEL 0A B Kg
DRF 100 109 304 1.5
DRF 125 133 304 1.5
DRF 150 158 404 1.8
DRF 200 209 404 1.8
DRF 250 259 404 1.8
DRF 315 325 404 1.8

54
sez.

55
2
part

DUCTED AXIAL FANS

TA-HP Pg. 59
sez.
High Performance Ducted Axial Fans

LISTED
2
Accessories - TA-HP Pg. 108

57
TA-HP
High Performance Ducted Axial Fans

DESCRIPTION
The tube axial fans of TA-HP series are used for ducted / non-ducted installation requiring
large air flow with relatively low to medium pressure drop, general ventilation and extrac-
tion, cooling and refrigeration in industrial, naval, commercial, civil, energy fields, electro-
mechanical cooling, environmental control and crop storage, petrochemical process venti-
lation. This series has the advantage of being smaller in dimension and easier to install. The
sez.
series consist of different sizes with impeller diameter from 400 to 1600 mm. TA-HP fans
can be fitted with motor of different polarity depending upon performances requirements.
Suitable for conveying clean air with temperature from -10ºC to 60ºC. 2
CONSTRUCTION
• Long casing in mild steel with fixing flanges manufactured according to UNI ISO
6580-EUROVENT standard.
• Protected against atmospheric agents by HDG (Hot Dip Galvanizing) coating.
• Axial impeller with X-ray inspected airfoil profile blades and hub in die cast aluminum
with multiple blade configurations for optimum performance.
• Impellers are statically and dynamically balanced according to ISO1940, G 2.5 and AMCA
204, BV-04 standard.
• Impellers provided with variable pitch angles ranging from 16 to 52 degrees.

MOTOR
Asynchronous three-phase motor according to international standard IEC 600034, IEC
LISTED 60072, EMC 2004/108/CE LVD 2006/95/CE Marked IP 55,IE 2 (only single speed motors)
CL F.

ACCESSORIES
• Flat (CCr) protection guard
Maico Gulf LLC certifies that the DYNAIR • Flexible connector (CCga).
model TA -HP 400 to TA-HP 1600 shown • Inlet / Outlet bell mouth (CCbo).
herein are licensed to bear the AMCA Seal. • Silencer with or without pod, in three lengths (CCsa & CCsb).
The ratings shown are based on tests and • Counter Flange (CCf)/ counter Flange with collar (CCfc)
procedures performed in accordance with • Anti-Vibration mounts
AMCA Publication 211 and AMCA Publica-
tion 311 and comply with the requirements BEYOND STANDARD PRODUCT
of the AMCA Certified Ratings Program. • Casing protection by epoxy paint and stainless steel
The AMCA Certified Ratings Seal applies • Higher fan diameters up to 2.0 meters.
to Sound, Air and FEG performance for • Multi-stage versions for higher pressure development
Models TA-HP 400 to TA-HP 1600 only. • IE3 motors (only single speed)
• Backdraft damper
• Completely reversible impeller

The AMCA Certified Ratings Seal ap-


plies to Sound and Air performance for
models TA-HP-400-240-12-6,TA-HP-400-
240-12-9,TA-HP-400-240-12-12,TA-HP-
450-240-12-6,TA-HP-450-240-12-9,TA-
HP-450-240-12-12.

59
PERFORMANCE TA-HP

60Hz
TA-HP-400-150-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
50
34

40 32 36
38 40 50 52
30 42 44 46 48
28
30 24
26
22
20
20
18
16

10
sez.

2
0
Absorbed Power (kW)
0.20 6
0.08
0.6 5
52
0.07 50
0.15 0.5 48
0.06 4 46
44
0.05 0.4 42

0.04 0.10 3 40
0.3 38

0.03
36
2
0.2
34
32
0.02 0.05 26
28 30

1
24
0.1
22
0.01 18 20
16

0.00 0.00 0.0 0


Static Pressure (Pa)
1000
100
Lw(A) at 3600 rpm
900
90
50 200
800
80

700
40 70
150
600
60 90
91

30 500
50

100
40 400 92 90

20
30 300

50 200
90
20 94
10

10 100
Speed
Pa]
Pv[
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
86 90 94
0 0 0 0
3600
0 2000 4000 6000 8000 10000 12000 14000 16000 2 Pole

1750
0 1000 2000 3000 4000 5000 6000 7000 4 Pole

1160
0 1000 2000 3000 4000 5000 6 Pole

875
0 1000 2000 3000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.011 0.013 0.016 0.019 0.021 0.023 0.026 0.029 0.031 0.034 0.038 0.042 0.046 0.051 0.055 0.060 0.065 0.069 0.074
-34
motor 0.04 0.06 0.09
1160 0.025 0.031 0.037 0.043 0.049 0.054 0.060 0.067 0.073 0.079 0.087 0.098 0.108 0.118 0.129 0.140 0.151 0.162 0.173
-27
motor 0.04 0.06 0.09 0.12 0.18
1750 0.087 0.107 0.127 0.148 0.169 0.186 0.207 0.229 0.250 0.272 0.300 0.335 0.371 0.406 0.443 0.480 0.517 0.555 0.594
-17
motor 0.09 0.12 0.18 0.25 0.37 0.55 0.75
3600 0.757 0.931 1.110 1.291 1.475 1.615 1.803 1.991 2.179 2.368 2.613 2.920 3.228 3.538 3.856 4.177 4.502 4.832 5.168
0
motor 1.1 1.5 2.2 3 4 5.5
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 3 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

60
PERFORMANCE TA-HP

60Hz
TA-HP-400-240-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
50

40

30
34 36 38
20
32 40 42 44 46 48 50 52
30
28
26
24
22
20
10 16 18

sez.

2
0
Absorbed Power (kW)
0.20 6
0.08
0.6 5
0.07 50
52

0.15 0.5
0.06
48
4 44
46

0.05 0.4 42

0.10 3
40
0.04 0.3 36
38

0.03 2 32
34
0.2 30
0.05
28
0.02 22
24
26

0.1 1 20
0.01
18
16

0.00 0.00 0.0 0


Static Pressure (Pa)
1100
250
60 1000
Lw(A) at 3600 rpm
100

900
50 200
800
80

700
40
150
600
60

30 500 91

100 93
40 400
91
20
300 94

50 200
90
20 96
10

100
Speed
a]
Pv [P 16
89
18 20 22 24 26 28 30 32
92 34 36 38 40 42 44 46 48
96 50 52
0 0 0 0
3600
0 2000 4000 6000 8000 10000 12000 2 Pole

1750
0 1000 2000 3000 4000 5000 4 Pole

1160
0 1000 2000 3000 6 Pole

875
0 500 1000 1500 2000 2500 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.012 0.015 0.018 0.021 0.023 0.026 0.027 0.030 0.032 0.035 0.038 0.042 0.046 0.050 0.055 0.059 0.063 0.067 0.071
-34
motor 0.04 0.06 0.09
1160 0.028 0.035 0.041 0.048 0.055 0.061 0.063 0.069 0.075 0.081 0.089 0.099 0.108 0.118 0.127 0.137 0.146 0.156 0.165
-27
motor 0.04 0.06 0.09 0.12 0.18
1750 0.097 0.119 0.142 0.165 0.187 0.210 0.217 0.238 0.259 0.280 0.306 0.338 0.371 0.404 0.436 0.469 0.502 0.534 0.568
-17
motor 0.12 0.18 0.25 0.37 0.55 0.75
3600 0.847 1.038 1.236 1.433 1.631 1.829 1.891 2.072 2.254 2.434 2.661 2.945 3.230 3.514 3.799 4.083 4.368 4.652 4.944
0
motor 1.1 1.5 2.2 3 4 5.5
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 2 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

61
PERFORMANCE TA-HP

60Hz
TA-HP-400-240-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
50

40

30

20
34 36
32 38 40 42 44 46 48 50 52
30
28
26
24
10
22
20
16 18

sez.

2
0
Absorbed Power (kW)
0.10 0.8 7
0.20 0.7 6
52

0.08
50

0.6 5 46
48

0.15 0.5 44
0.06 4 42

0.4
40
38
0.04 0.10 3 36
0.3 32
34
2 30
0.2
28
0.05
26
0.02
24
22
1
20
0.1 16
18

0.00 0.00 0.0 0


Static Pressure (Pa)
70 1200
120
Lw(A) at 3600 rpm
250
60 1000
100

50 200
800
80

40
150
600
60 91

30 93

100
40 400
20 95

93 92
50 200
20
10

Speed
a]
Pv[ P
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
90 92 97
0 0 0 0
3600
0 2000 4000 6000 8000 10000 12000 14000 2 Pole

1750
0 1000 2000 3000 4000 5000 6000 4 Pole

1160
0 1000 2000 3000 4000 6 Pole

875
0 500 1000 1500 2000 2500 3000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.015 0.018 0.021 0.024 0.027 0.029 0.032 0.035 0.038 0.041 0.045 0.050 0.055 0.060 0.065 0.070 0.076 0.081 0.087
-34
motor 0.04 0.06 0.09
1160 0.035 0.042 0.049 0.056 0.063 0.067 0.074 0.081 0.089 0.096 0.105 0.116 0.127 0.139 0.151 0.164 0.177 0.190 0.204
-27
motor 0.04 0.06 0.09 0.12 0.18 0.25
1750 0.119 0.144 0.168 0.192 0.217 0.229 0.254 0.279 0.305 0.330 0.362 0.399 0.437 0.477 0.519 0.563 0.606 0.651 0.699
-17
motor 0.12 0.18 0.25 0.37 0.55 0.75
3600 1.038 1.250 1.462 1.673 1.885 1.992 2.212 2.430 2.651 2.871 3.149 3.477 3.805 4.150 4.519 4.898 5.277 5.668 6.083
0
motor 1.1 1.5 2.2 3 4 5.5 7.5
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 4 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

62
PERFORMANCE TA-HP

60Hz
TA-HP-400-240-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
50

40

30

20 34 36 38 40 42 44 46 48 50 52
32
30
28
10
26
24
22
18 20
16
sez.

2
0
Absorbed Power (kW)
8
0.25
0.10 0.8 7 50
52

0.20 6
48

0.08 46
0.6 5 44

0.15
42
0.06 4
40

0.4
38

0.10 3
36
0.04 32
34
30
2
28
0.2
26
0.05
24
0.02 20
22
1 16
18

0.00 0.00 0.0 0


Static Pressure (Pa)
1400
80 140

300
Lw(A) at 3600 rpm
70 1200
120

250
60 1000
100

50 200 93
800
80

40 93 91
150
60 600

30

100 400
40
20 95

50 200
20
10
Speed
a]
Pv[ P 16
90
18 20 22 24 26 28 30 32
93
34 36 38 40 42 44 46 48 50
98
52

0 0 0 0
3600
0 2000 4000 6000 8000 10000 12000 14000 2 Pole

1750
0 1000 2000 3000 4000 5000 6000 4 Pole

1160
0 1000 2000 3000 4000 6 Pole

875
0 500 1000 1500 2000 2500 3000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.018 0.022 0.026 0.030 0.029 0.033 0.036 0.040 0.044 0.048 0.052 0.058 0.064 0.069 0.075 0.081 0.088 0.095 0.102
-34
motor 0.04 0.06 0.09 0.12
1160 0.042 0.051 0.061 0.070 0.067 0.076 0.085 0.094 0.103 0.112 0.122 0.135 0.148 0.161 0.175 0.189 0.204 0.221 0.237
-27
motor 0.06 0.09 0.12 0.18 0.25
1750 0.144 0.176 0.209 0.241 0.230 0.261 0.291 0.322 0.353 0.383 0.420 0.464 0.508 0.553 0.599 0.649 0.702 0.757 0.814
-17
motor 0.18 0.25 0.37 0.55 0.75 1.1
3600 1.254 1.535 1.817 2.100 2.003 2.269 2.536 2.804 3.071 3.338 3.656 4.041 4.426 4.810 5.218 5.653 6.109 6.594 7.087
0
motor 1.5 2.2 3 4 5.5 7.5
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 1 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

63
PERFORMANCE TA-HP

60Hz
TA-HP-450-150-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG63
60
50
34
36 38 52
40
32 40 42 44 46 48 50
30
28
30
26
24
22
16 18 20
20
10
sez.

2
0
Absorbed Power (kW)
0.30 1.0 9 52
0.12 8 50
0.25 48
0.10 0.8 7 46
44
0.20 6
0.08 42
0.6 5 40

0.06 0.15 38
4 36
0.4 34
0.04 0.10 3 30
32
28
2
26
0.2
24
0.05
22
0.02 20
1 16
18

0.00 0.00 0.0 0


Static Pressure (Pa)
70 1200
120
Lw(A) at 3600 rpm
250
60 1000
100

50 200
800
80

40
150 91
600
60

30
95 94
100
40 400
20

96

50 200
20
10

Speed
Pa]
Pv[ 89
16 18 20 22 24 26 28 30 32
93
34 36 38 40 42 44 46 48 50 52
99
0 0 0 0
3600
0 5000 10000 15000 20000 25000 2 Pole

1750
0 2000 4000 6000 8000 10000 12000 4 Pole

1160
0 1000 2000 3000 4000 5000 6000 7000 8000 6 Pole

875
0 1000 2000 3000 4000 5000 6000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.015 0.019 0.024 0.028 0.033 0.038 0.042 0.047 0.052 0.056 0.062 0.069 0.075 0.082 0.090 0.098 0.106 0.114 0.123
-34
motor 0.04 0.06 0.09 0.12 0.18
1160 0.034 0.044 0.055 0.066 0.076 0.088 0.098 0.110 0.120 0.131 0.145 0.160 0.176 0.192 0.209 0.228 0.247 0.266 0.286
-27
motor 0.04 0.06 0.09 0.12 0.18 0.25 0.37
1750 0.118 0.152 0.188 0.225 0.262 0.301 0.338 0.376 0.412 0.450 0.496 0.550 0.603 0.658 0.719 0.782 0.847 0.914 0.982
-17
motor 0.12 0.18 0.25 0.37 0.55 0.75 1.1
3600 1.023 1.323 1.637 1.959 2.285 2.619 2.940 3.275 3.589 3.921 4.321 4.785 5.250 5.729 6.259 6.810 7.371 7.958 8.545
0
motor 1.1 1.5 2.2 3 4 5.5 7.5 11
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 7 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

64
PERFORMANCE TA-HP

60Hz
TA-HP-450-240-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
50

40

30 34 36
38 40 42 44 46 48 50 52
32
30
20 28
26
24
22
10 16
18
20

sez.

2
0
Absorbed Power (kW)
0.30 1.0 9
0.12 8 50
52

0.25 48
0.10 0.8 7 46
44
0.20 6
0.08
42

0.6 5 38
40

0.06 0.15
4
36
34
0.4 32

0.04 0.10 3 28
30
26
2 24
0.2
22
0.02 0.05 18
20
1 16

0.00 0.00 0.0 0


Static Pressure (Pa)
70 1200
120
Lw(A) at 3600 rpm
250
60 1000
100

50 200
800
80

40
150
600 94
60
95

30
95
100
40 400 97

20

93
50 200
20
10

Speed
Pa]
Pv [
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
90 94 100
0 0 0 0
3600
0 5000 10000 15000 20000 2 Pole

1750
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 4 Pole

1160
0 1000 2000 3000 4000 5000 6000 6 Pole

875
0 1000 2000 3000 4000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.018 0.023 0.029 0.034 0.040 0.042 0.047 0.052 0.057 0.062 0.067 0.074 0.080 0.087 0.093 0.100 0.107 0.114 0.121
-34
motor 0.04 0.06 0.09 0.12 0.18
1160 0.042 0.054 0.067 0.080 0.093 0.097 0.109 0.120 0.132 0.144 0.156 0.172 0.187 0.202 0.216 0.232 0.249 0.265 0.282
-27
motor 0.06 0.09 0.12 0.18 0.25 0.37
1750 0.143 0.184 0.230 0.275 0.321 0.333 0.373 0.413 0.453 0.493 0.537 0.589 0.641 0.693 0.741 0.797 0.854 0.911 0.968
-17
motor 0.18 0.25 0.37 0.55 0.75 1.1
3600 1.242 1.605 2.002 2.398 2.794 2.895 3.244 3.595 3.944 4.295 4.675 5.128 5.580 6.033 6.448 6.942 7.436 7.930 8.424
0
motor 1.5 2.2 3 4 5.5 7.5 11
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 6 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

65
PERFORMANCE TA-HP

60Hz
TA-HP-450-240-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
50

40

30
34 48 50 52
36 38 40 42 44 46
32
20
30
28
26
24
22
20
10 16 18

sez.

2
0
Absorbed Power (kW)
0.4 12
0.16
1.2
52

0.14 10 50
48
0.3 1.0
0.12
46
8 44

0.10 0.8
42
40

0.08 0.2 6 38
0.6 36

0.06
34
4 32
0.4 30
0.1
28
0.04 24
26

0.2 2 20
22
0.02 16
18

0.00 0.0 0.0 0


Static Pressure (Pa)
1600
90 160
350 Lw(A) at 3600 rpm
1400
80 140
300
70 1200
120

250
60 1000
100

50 200
800
80 95

40
150 95
600
60
30 97

100 400
40
20
96

50 200
10 20
Speed
Pa]
Pv[ 16
92
18 20 22 24 26 28 30 32
95
34 36 38 40 42 44 46 48 50
100
52

0 0 0 0
3600
0 5000 10000 15000 20000 2 Pole

1750
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 4 Pole

1160
0 1000 2000 3000 4000 5000 6000 6 Pole

875
0 1000 2000 3000 4000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.024 0.030 0.036 0.042 0.048 0.055 0.055 0.061 0.067 0.073 0.080 0.088 0.097 0.106 0.115 0.124 0.134 0.143 0.153
-34
motor 0.04 0.06 0.09 0.12 0.18
1160 0.056 0.070 0.084 0.099 0.113 0.127 0.128 0.142 0.156 0.170 0.187 0.206 0.226 0.247 0.268 0.290 0.311 0.333 0.356
-27
motor 0.06 0.09 0.12 0.18 0.25 0.37
1750 0.192 0.241 0.290 0.339 0.387 0.436 0.440 0.488 0.537 0.585 0.642 0.706 0.775 0.847 0.920 0.994 1.069 1.143 1.222
-17
motor 0.25 0.37 0.55 0.75 1.1 1.5
3600 1.669 2.095 2.521 2.947 3.373 3.799 3.829 4.250 4.673 5.095 5.585 6.147 6.749 7.374 8.012 8.657 9.303 9.948 10.640
0
motor 2.2 3 4 5.5 7.5 11
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 8 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

66
PERFORMANCE TA-HP

60Hz
TA-HP-450-240-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
50

40

30 52
48 50
34 42 44 46
36 38 40
32
20 28
30
26
24
22
10 16 18
20

sez.

2
0
Absorbed Power (kW)
0.20 1.6 14
0.4 1.4 12 52
50
0.15 1.2 10 48
46
0.3 1.0 44
8 42

0.10 0.8 40

0.2 6
38

0.6 34
36

4
32
30
0.05 0.1 0.4 24
26
28

2
22
0.2 16
18
20

0.00 0.0 0.0 0


Static Pressure (Pa)
1800

100 400
Lw(A) at 3600 rpm
1600

150
1400
80
300
1200

95
60 1000
100

200
800

40
98 95
600

50
100
400
20 97

200
Speed
Pa]
Pv[ 16
92
18 20 22 24 26 28 30 32
95
34 36 38 40 42 44 46 48 50
100
52

0 0 0 0
3600
0 5000 10000 15000 20000 2 Pole

1750
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 4 Pole

1160
0 1000 2000 3000 4000 5000 6000 6 Pole

875
0 1000 2000 3000 4000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.033 0.040 0.046 0.053 0.050 0.057 0.064 0.071 0.078 0.085 0.094 0.103 0.111 0.120 0.129 0.139 0.149 0.158 0.169
-34
motor 0.04 0.06 0.09 0.12 0.18
1160 0.077 0.092 0.108 0.123 0.117 0.133 0.149 0.165 0.181 0.198 0.218 0.239 0.260 0.281 0.302 0.324 0.346 0.369 0.394
-27
motor 0.09 0.12 0.12
0.18 0.18 0.25 0.37 0.55
1750 0.264 0.317 0.370 0.422 0.400 0.457 0.513 0.567 0.623 0.679 0.749 0.820 0.892 0.964 1.036 1.111 1.188 1.268 1.352
-17
motor 0.37 0.55 0.75 1.1 1.5
3600 2.302 2.760 3.218 3.677 3.486 3.977 4.468 4.936 5.424 5.911 6.522 7.141 7.765 8.390 9.017 9.670 10.343 11.037 11.767
0
motor 3 4 5.5 7.5 11 15
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 5 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

67
PERFORMANCE TA-HP

60Hz
TA-HP-500-150-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
50 34
36
32 38
40 42 44
40 30 46 48 50 52
28
30 24
26

22
20 18
20
16
10
sez.

2
0
Absorbed Power (kW)
0.20 1.6 14
1.4
52
0.4 12 50

0.15 1.2
48
10 46
0.3 1.0
44

8 42

0.10 0.8
40
38
0.2 6
0.6
36
32 34
4 30
0.05 0.4
28
0.1 24 26
22
2
20
0.2
18
16

0.00 0.0 0.0 0


Static Pressure (Pa)
70 1200
120
Lw(A) at 3600 rpm
250
60 1000
100

50 200
800
80

40 93

150
600
60

30
98
100
40 400
20

98

50 200
20
10

Speed
Pa]
Pv[
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
95 95 100
0 0 0 0
3600
0 5000 10000 15000 20000 25000 30000 2 Pole

1750
0 2000 4000 6000 8000 10000 12000 14000 4 Pole

1160
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 6 Pole

875
0 1000 2000 3000 4000 5000 6000 7000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.028 0.033 0.038 0.043 0.048 0.054 0.059 0.065 0.070 0.076 0.084 0.095 0.107 0.118 0.130 0.141 0.153 0.165 0.177
-34
motor 0.04 0.06 0.09 0.12 0.18
1160 0.064 0.076 0.089 0.099 0.112 0.125 0.138 0.151 0.164 0.177 0.195 0.222 0.249 0.275 0.302 0.329 0.356 0.384 0.413
-27
motor 0.09 0.12 0.18 0.25 0.37 0.55
1750 0.221 0.261 0.305 0.342 0.385 0.430 0.474 0.519 0.563 0.608 0.669 0.761 0.853 0.945 1.038 1.130 1.222 1.319 1.418
-17
motor 0.25 0.37 0.55 0.75 1.1 1.5
3600 1.921 2.275 2.651 2.973 3.355 3.741 4.128 4.516 4.904 5.293 5.826 6.628 7.430 8.231 9.033 9.835 10.637 11.485 12.342
0
motor 2.2 3 4 5.5 7.5 11 15
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 11 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

68
PERFORMANCE TA-HP

60Hz
TA-HP-500-240-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
60
FEG57
50

40 34
32 36
38 40
30 30 42 44 46 48 50 52
28
26

20
24
22
20
18
16
10
sez.

2
0
Absorbed Power (kW)
16
0.5
0.20 14 52
1.5 50
0.4 12 48
46
0.15 10 44

0.3 1.0
42

8
40

0.10
38

0.2 6
36
32 34
0.5
30
4 26 28
0.05 0.1 20
22
24

2
18
16

0.00 0.0 0.0 0


Static Pressure (Pa)
1400
80 140

300
Lw(A) at 3600 rpm
70 1200
120

250
60 1000
100

50 200
800
80
95
40
150
60 600
99
30 95

100 400
40
20 96

50 200
20
10
Speed
Pa]
Pv[ 92 16 18 20 22 24 26 28 30 32
95 34 36 38 40 42 44 46 48 50
100 52

0 0 0 0
3600
0 5000 10000 15000 20000 25000 2 Pole

1750
0 2000 4000 6000 8000 10000 12000 4 Pole

1160
0 1000 2000 3000 4000 5000 6000 7000 8000 6 Pole

875
0 1000 2000 3000 4000 5000 6000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.032 0.038 0.046 0.050 0.056 0.063 0.069 0.076 0.082 0.088 0.095 0.108 0.120 0.133 0.145 0.158 0.170 0.183 0.197
-34
motor 0.04 0.06 0.09 0.12 0.18 0.25
1160 0.074 0.090 0.108 0.117 0.132 0.146 0.161 0.176 0.191 0.206 0.222 0.251 0.280 0.309 0.338 0.367 0.396 0.427 0.459
-27
motor 0.09 0.12 0.18 0.25 0.37 0.55
1750 0.255 0.308 0.370 0.401 0.452 0.503 0.554 0.605 0.656 0.707 0.761 0.861 0.961 1.061 1.161 1.261 1.361 1.468 1.575
-17
motor 0.37 0.55 0.75 1.1 1.5 2.2
3600 2.218 2.677 3.222 3.491 3.934 4.377 4.820 5.265 5.710 6.155 6.629 7.499 8.368 9.237 10.107 10.976 11.845 12.777 13.711
0
motor 3 4 5.5 7.5 11 15
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 10 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

69
PERFORMANCE TA-HP

60Hz
TA-HP-500-240-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
60
FEG57
50

40
34
36
32 38
30
40 42 44 46 48 50 52
30
28
26
20 22
24
20
18
10 16

sez.

2
0
Absorbed Power (kW)
20
0.25 0.6 2.0 52
50
0.5 15 48
0.20
1.5
46

0.4
44
42
0.15 10 40
0.3 1.0 38
36
0.10
0.2
34
32
5
30
28
0.5 24 26
0.05 0.1 18 20
22
16

0.00 0.0 0.0 0


Static Pressure (Pa)
1600
90 160
350 Lw(A) at 3600 rpm
1400
80 140
300
70 1200
120

250
60 1000
100 97

50 200
800
80

40 99 96
150
600
60
30
100 400
40
99

20

50 200
10 20
Speed
Pa ]
P v[
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
94 97 102
0 0 0 0
3600
0 5000 10000 15000 20000 25000 30000 2 Pole

1750
0 2000 4000 6000 8000 10000 12000 14000 4 Pole

1160
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 6 Pole

875
0 1000 2000 3000 4000 5000 6000 7000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.036 0.045 0.055 0.060 0.068 0.077 0.086 0.094 0.103 0.111 0.117 0.132 0.148 0.163 0.179 0.194 0.209 0.226 0.243
-34
motor 0.04 0.06 0.09 0.12 0.18 0.25
1160 0.085 0.106 0.127 0.140 0.160 0.179 0.199 0.219 0.239 0.260 0.272 0.308 0.344 0.380 0.416 0.452 0.488 0.526 0.566
-27
motor 0.09 0.12 0.18 0.25 0.37 0.55 0.75
1750 0.292 0.363 0.437 0.479 0.548 0.616 0.685 0.753 0.822 0.891 0.934 1.058 1.182 1.305 1.429 1.552 1.676 1.807 1.944
-17
motor 0.37 0.55 0.75 1.1 1.5 2.2
3600 2.542 3.158 3.801 4.174 4.768 5.362 5.960 6.558 7.158 7.757 8.135 9.210 10.286 11.361 12.437 13.512 14.588 15.730 16.920
0
motor 3 4 5.5 7.5 11 15 18.5
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 12 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

70
PERFORMANCE TA-HP

60Hz
TA-HP-500-240-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
60
FEG57
50

40
34
30
36 38 48 50 52
32 40 42 44 46
30
28
20 26
24
22
10
20
18
16
sez.

2
0
Absorbed Power (kW)
0.35 25
0.8
0.30 0.7 2.5
20 50
52

0.25 0.6 2.0 48


46
0.5 15
0.20 1.5 42
44

0.4 40
0.15 10 38
0.3 1.0 36
0.10 34
0.2 30 32
5
28
0.5 24 26
0.05
22
0.1 16 18 20

0.00 0.0 0.0 0


Static Pressure (Pa)
2500
250
140
Lw(A) at 3600 rpm
500
120 2000
200

100 400

1500
150
80 99

300

60 1000
100 103
200

40

50 500
100
20

Speed
Pa]
Pv[ 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52

0 0 0 0
3600
0 5000 10000 15000 20000 25000 30000 2 Pole

1750
0 2000 4000 6000 8000 10000 12000 14000 4 Pole

1160
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 6 Pole

875
0 1000 2000 3000 4000 5000 6000 7000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.047 0.058 0.070 0.072 0.082 0.092 0.103 0.113 0.123 0.134 0.138 0.157 0.176 0.194 0.213 0.232 0.250 0.269 0.288
-34
motor 0.06 0.09 0.12 0.18 0.25 0.37
1160 0.109 0.136 0.163 0.167 0.191 0.215 0.239 0.263 0.287 0.311 0.323 0.366 0.410 0.453 0.496 0.540 0.583 0.627 0.670
-27
motor 0.12 0.18 0.25 0.37 0.55 0.75
1750 0.375 0.466 0.558 0.573 0.656 0.738 0.821 0.903 0.986 1.069 1.108 1.257 1.406 1.555 1.705 1.854 2.003 2.152 2.302
-17
motor 0.55 0.75 1.1 1.5 2.2 3
3600 3.264 4.061 4.858 4.987 5.707 6.426 7.146 7.865 8.585 9.304 9.643 10.942 12.241 13.541 14.840 16.139 17.438 18.737 20.037
0
motor 4 5.5 7.5 11 15 18.5 22
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 9 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

71
PERFORMANCE TA-HP

60Hz
TA-HP-560-150-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
34
50 32
36
38 40 42 44 46 48 50 52
30
40 28
26
30 22
24

20
20 16
18

10
sez.

2
0
Absorbed Power (kW)
0.35 25
0.8
0.30 0.7 2.5
20 52

0.25 0.6 2.0 48


50

0.5 15 46
0.20 1.5
44
0.4 42

0.15 10
40

0.3
38
1.0 36
0.10
0.2 32 34
30
0.5 5 24 26 28

0.05 0.1 18 20 22
16

0.00 0.0 0.0 0


Static Pressure (Pa)
1400
80 140

300
Lw(A) at 3600 rpm
70 1200
120

250
60 1000
100

50 200
800
80
97
40
150
60 600

30 101

100 400
40
20
101

50 200
20
10
Speed
a]
Pv[ P 9916 18 20 22 24 26 28 30 97
32 34 36 38 40 42 44 46 102 50
48 52
0 0 0 0
3600
0 5000 10000 15000 20000 25000 30000 35000 40000 2 Pole

1750
0 5000 10000 15000 4 Pole

1160
0 2000 4000 6000 8000 10000 12000 6 Pole

875
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.032 0.040 0.050 0.060 0.067 0.076 0.085 0.095 0.104 0.113 0.129 0.146 0.163 0.181 0.199 0.218 0.237 0.255 0.276
-34
motor 0.04 0.06 0.09 0.12 0.18 0.25 0.37
1160 0.075 0.094 0.116 0.140 0.157 0.178 0.199 0.220 0.242 0.263 0.301 0.341 0.381 0.422 0.464 0.508 0.551 0.595 0.642
-27
motor 0.09 0.12 0.18 0.25 0.37 0.55 0.75
1750 0.257 0.321 0.399 0.481 0.539 0.611 0.684 0.756 0.829 0.902 1.034 1.171 1.308 1.449 1.595 1.743 1.892 2.042 2.205
-17
motor 0.37 0.55 0.75 1.1 1.5 2.2 3
3600 2.238 2.797 3.472 4.183 4.688 5.319 5.951 6.586 7.220 7.855 9.002 10.193 11.385 12.617 13.884 15.174 16.475 17.780 19.192
0
motor 3 4 5.5 7.5 11 15 18.5 22
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 15 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

72
PERFORMANCE TA-HP

60Hz
TA-HP-560-240-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG60
60
50
34
36
40
32 38 40
30 42 44 46 48 50 52
28
30
26
24
22
20
20
16 18

10
sez.

2
0
Absorbed Power (kW)
0.35 25
0.8
0.30 0.7 2.5 52

20
50
48
0.25 0.6 2.0 46
44
0.5 15
0.20
42
1.5 40
0.4 38
0.15 10 36
0.3 1.0 32
34
0.10 30
0.2
28
26
0.5 5 22
24
0.05 0.1 16
18
20

0.00 0.0 0.0 0


Static Pressure (Pa)
1600
90 160
350 Lw(A) at 3600 rpm
1400
80 140
300
70 1200
120

250
60 1000
100
96
50 200
800
80

40
150 101
600
60
30
101
100 400
40
20

50 200
10 20
Speed
Pa]
Pv[
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
94 98 104
0 0 0 0
3600
0 5000 10000 15000 20000 25000 30000 35000 40000 2 Pole

1750
0 5000 10000 15000 4 Pole

1160
0 2000 4000 6000 8000 10000 12000 6 Pole

875
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.040 0.050 0.064 0.077 0.084 0.096 0.107 0.119 0.131 0.142 0.158 0.177 0.195 0.214 0.233 0.253 0.273 0.293 0.313
-34
motor 0.04 0.06 0.09 0.12 0.18 0.25 0.37
1160 0.092 0.118 0.148 0.179 0.196 0.223 0.250 0.277 0.304 0.331 0.369 0.412 0.454 0.499 0.544 0.590 0.636 0.683 0.729
-27
motor 0.12 0.18 0.25 0.37 0.55 0.75
1750 0.317 0.404 0.509 0.614 0.675 0.767 0.859 0.952 1.044 1.137 1.266 1.413 1.560 1.712 1.867 2.024 2.184 2.344 2.504
-17
motor 0.37 0.55 0.75 1.1 1.5 2.2 3
3600 2.762 3.516 4.432 5.348 5.873 6.678 7.482 8.287 9.092 9.897 11.025 12.300 13.581 14.905 16.256 17.622 19.013 20.404 21.795
0
motor 3 4 5.5 7.5 11 15 18.5 22
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 14 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

73
PERFORMANCE TA-HP

60Hz
TA-HP-560-240-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
60
FEG60
50
34
40 32
36 38
40 42 44 46 48 50 52
30

30 26
28

24

20 20
22
18
16

10
sez.

2
0
Absorbed Power (kW)
1.0 30
0.4 52
3.0 25
50
0.8 48

0.3 2.5 46
20 44

0.6 2.0
42
40

0.2 15 38
1.5
0.4 36

10 34
1.0
32
30
0.1
28
26
0.2 5
24
0.5
22
20
18
16

0.0 0.0 0.0 0


Static Pressure (Pa)
2000
200
Lw(A) at 3600 rpm
100 400

1500
150
80
300

60 1000 99
100

200

40
103

50 500
100
101
20

Speed
P a]
Pv[ 16
98
18 20 22 24 26 28 30 32
99
34 36 38 40 42 44 46 48 50 52
105
0 0 0 0
3600
0 10000 20000 30000 40000 50000 2 Pole

1750
0 5000 10000 15000 20000 4 Pole

1160
0 2000 4000 6000 8000 10000 12000 14000 16000 6 Pole

875
0 2000 4000 6000 8000 10000 12000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.049 0.064 0.081 0.098 0.103 0.118 0.132 0.147 0.162 0.176 0.196 0.217 0.239 0.264 0.289 0.314 0.340 0.367 0.395
-34
motor 0.06 0.09 0.12 0.18 0.25 0.37 0.55
1160 0.115 0.149 0.188 0.228 0.240 0.274 0.308 0.342 0.377 0.411 0.456 0.506 0.558 0.614 0.673 0.732 0.791 0.854 0.920
-27
motor 0.12 0.18 0.25 0.37 0.55 0.75 1.1
1750 0.394 0.512 0.647 0.782 0.824 0.941 1.059 1.176 1.293 1.411 1.566 1.739 1.916 2.109 2.310 2.514 2.717 2.933 3.158
-17
motor 0.55 0.75 1.1 1.5 2.2 3 4
3600 3.428 4.457 5.632 6.807 7.170 8.192 9.215 10.237 11.260 12.283 13.630 15.136 16.677 18.362 20.112 21.885 23.657 25.534 27.495
0
motor 4 5.5 7.5 11 15 18.5 22 30
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* Performance
The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 16 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

74
PERFORMANCE TA-HP

60Hz
TA-HP-560-240-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
60
FEG60
50

40 34
36 38 44 46 48 50 52
32 40 42

30
30
28
26

20 22
24

20
18
10
16

sez.

2
0
Absorbed Power (kW)
0.5 4 35
52

1.0 30 50
0.4 48
3 25 46
0.8 44
0.3 20
42

0.6 2 38
40

0.2 15 36
0.4 34
10 32
1
30
28
0.1
26
0.2
24
5
22
20
18
16

0.0 0.0 0 0
Static Pressure (Pa)
2500
250
140
Lw(A) at 3600 rpm
500
120 2000
200

100 400

1500
150
80 99

300

60 1000
100 103 99
200

40

50 500 102
100
20

Speed
Pa ]
P v[ 98
16 18 20 22 24 26 28 30 32
100
34 36 38 40 42 44 46 48 50
105
52
0 0 0 0
3600
0 10000 20000 30000 40000 50000 2 Pole

1750
0 5000 10000 15000 20000 4 Pole

1160
0 2000 4000 6000 8000 10000 12000 14000 16000 6 Pole

875
0 2000 4000 6000 8000 10000 12000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.063 0.081 0.101 0.121 0.125 0.143 0.161 0.180 0.198 0.216 0.241 0.268 0.295 0.322 0.349 0.377 0.406 0.436 0.466
-34
motor 0.09 0.12 0.18 0.25 0.37 0.55
1160 0.147 0.189 0.235 0.281 0.291 0.334 0.376 0.419 0.461 0.504 0.561 0.624 0.687 0.750 0.813 0.879 0.947 1.016 1.086
-27
motor 0.18 0.25 0.37 0.55 0.75 1.1
1750 0.505 0.649 0.807 0.965 1.001 1.146 1.292 1.438 1.584 1.731 1.927 2.143 2.360 2.576 2.793 3.018 3.250 3.487 3.728
-17
motor 0.55 0.75 1.1 1.5 2.2 3 4
3600 4.393 5.649 7.024 8.399 8.711 9.979 11.247 12.515 13.789 15.067 16.773 18.659 20.544 22.429 24.316 26.276 28.294 30.355 32.456
0
motor 5.5 7.5 11 15 18.5 22 30 37
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 13 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

75
PERFORMANCE TA-HP

60Hz
TA-HP-630-150-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60 34
36 52
38 48 50
50 32 40 42 44 46

30

40 28
26
30 24
22
20
20 16
18

10
sez.

2
0
Absorbed Power (kW)
1.0 30
0.4 52

3.0 25
50

0.8
48

0.3 2.5 46

20 44

0.6
42
2.0 40

0.2 15 38
1.5
0.4
36
34
10 32
1.0 28
30
0.1 26
0.2
24

0.5 5 18
20
22
16

0.0 0.0 0.0 0


Static Pressure (Pa)
1400
80 140

300
Lw(A) at 3600 rpm
70 1200
120

250
60 1000
100

50 200
800
80

40
150
60 600

30

100 400
40
20

50 200
20
10
Speed
Pa ]
Pv[ 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52

0 0 0 0
3600
0 10000 20000 30000 40000 50000 60000 2 Pole

1750
0 5000 10000 15000 20000 25000 4 Pole

1160
0 5000 10000 15000 6 Pole

875
0 2000 4000 6000 8000 10000 12000 14000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.038 0.054 0.070 0.086 0.101 0.117 0.133 0.149 0.165 0.181 0.204 0.228 0.253 0.277 0.301 0.326 0.350 0.375 0.401
-34
motor 0.04 0.06 0.09 0.12 0.18 0.25 0.37 0.55
1160 0.088 0.125 0.162 0.201 0.236 0.274 0.311 0.348 0.385 0.423 0.475 0.532 0.589 0.645 0.702 0.759 0.815 0.874 0.933
-27
motor 0.09 0.18 0.25 0.37 0.55 0.75 1.1
1750 0.303 0.428 0.557 0.690 0.812 0.940 1.067 1.195 1.323 1.451 1.632 1.827 2.021 2.215 2.410 2.605 2.800 3.000 3.205
-17
motor 0.37 0.55 0.75 1.1 1.5 2.2 3 4
3600 2.634 3.728 4.848 6.003 7.066 8.179 9.293 10.406 11.520 12.633 14.208 15.901 17.594 19.287 20.981 22.674 24.372 26.118 27.897
0
motor 3 4 5.5 7.5 11 15 18.5 22 30
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 19 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

76
PERFORMANCE TA-HP

60Hz
TA-HP-630-240-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG63
60
34
50 32
36
38 40
42 44 46 48 50 52
30
40 28
26
24
30 20
22
16 18

20
10
sez.

2
0
Absorbed Power (kW)
40
0.5 1.2 4 35 52
50
1.0 30
0.4
48

3
46
25
0.8
44
42
0.3 20 40
0.6 2 38

0.2 15 34
36

0.4 32
10
30
1
28
26
0.1 0.2
22
24
5 16
18
20

0.0 0.0 0 0
Static Pressure (Pa)
1600
90 160
350 Lw(A) at 3600 rpm
1400
80 140
300
70 1200
120

250
60 1000
100

50 200
800
80

40
150
600
60
30
100 400
40
20

50 200
10 20
Speed
Pa]
Pv[
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52

0 0 0 0
3600
0 10000 20000 30000 40000 50000 60000 2 Pole

1750
0 5000 10000 15000 20000 25000 4 Pole

1160
0 5000 10000 15000 6 Pole

875
0 2000 4000 6000 8000 10000 12000 14000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.049 0.067 0.086 0.104 0.123 0.142 0.160 0.179 0.198 0.217 0.243 0.271 0.299 0.327 0.355 0.384 0.414 0.446 0.479
-34
motor 0.06 0.09 0.12 0.18 0.25 0.37 0.55
1160 0.114 0.156 0.201 0.243 0.286 0.330 0.374 0.417 0.461 0.505 0.566 0.631 0.697 0.762 0.828 0.895 0.966 1.040 1.117
-27
motor 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5
1750 0.391 0.537 0.689 0.833 0.983 1.133 1.283 1.433 1.584 1.734 1.943 2.168 2.393 2.617 2.842 3.073 3.316 3.570 3.834
-17
motor 0.55 0.75 1.1 1.5 2.2 3 4
3600 3.402 4.676 6.000 7.254 8.558 9.863 11.170 12.478 13.787 15.096 16.912 18.870 20.828 22.785 24.743 26.756 28.864 31.079 33.380
0
motor 4 5.5 7.5 11 15 18.5 22 30 37
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 18 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

77
PERFORMANCE TA-HP

60Hz
TA-HP-630-240-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
50 34
36
32 38 48 50 52
40 42 44 46
40 28
30

30
26
24
22
20
20
18
16

10
sez.

2
0
Absorbed Power (kW)
0.7 50
1.6
0.6 1.4 5 52

40
50
48
0.5 1.2 4 46

30
44
0.4 1.0 42
3
0.8 40

0.3 20
38
0.6 2
36

0.2
34
32
0.4 30
10
28
1 24 26
0.1 0.2 18
20
22
16

0.0 0.0 0 0
Static Pressure (Pa)
2500
250
140
Lw(A) at 3600 rpm
500
120 2000
200

100 400

1500
150
80
300

60 1000
100
200

40

50 500
100
20

Speed
Pa]
Pv [ 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52

0 0 0 0
3600
0 10000 20000 30000 40000 50000 60000 2 Pole

1750
0 5000 10000 15000 20000 25000 4 Pole

1160
0 5000 10000 15000 6 Pole

875
0 2000 4000 6000 8000 10000 12000 14000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.064 0.086 0.113 0.132 0.156 0.179 0.203 0.226 0.250 0.273 0.304 0.341 0.379 0.419 0.461 0.503 0.546 0.589 0.633
-34
motor 0.09 0.12 0.18 0.25 0.37 0.55 0.75
1160 0.149 0.200 0.262 0.308 0.363 0.418 0.472 0.527 0.582 0.637 0.708 0.795 0.883 0.977 1.073 1.172 1.271 1.372 1.475
-27
motor 0.18 0.25 0.37 0.55 0.75 1.1 1.5
1750 0.512 0.687 0.901 1.058 1.246 1.434 1.622 1.810 1.998 2.186 2.430 2.730 3.033 3.354 3.685 4.023 4.365 4.712 5.063
-17
motor 0.55 0.75 1.1 1.5 2.2 3 4 5.5
3600 4.459 5.978 7.840 9.209 10.846 12.483 14.120 15.757 17.394 19.031 21.156 23.762 26.402 29.199 32.082 35.019 38.001 41.020 44.079
0
motor 5.5 7.5 11 15 18.5 22 30 37 45
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 20 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

78
PERFORMANCE TA-HP

60Hz
TA-HP-630-240-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG63
60
50
34 50 52
36 46 48
40
38 40 42 44
32
30

30
28
26
24
20
22
20
16 18

10
sez.

2
0
Absorbed Power (kW)
2.0 60
0.8
6 50
52
0.7 50

1.5 5
48
0.6 40
46
44
0.5 4 42

0.4 1.0 30 40
3 38

0.3
36
20
2 34
0.5
32
0.2 26 28
30

1 10 22
24
0.1 16 18
20

0.0 0.0 0 0
Static Pressure (Pa)
700 3000
300
Lw(A) at 3600 rpm
150 600 2500
250

500
2000
200

100 400

1500
150

300

100 1000
50 200

50 500
100

Speed
Pa]
Pv[
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52

0 0 0 0
3600
0 10000 20000 30000 40000 50000 60000 70000 2 Pole

1750
0 5000 10000 15000 20000 25000 30000 4 Pole

1160
0 5000 10000 15000 20000 6 Pole

875
0 2000 4000 6000 8000 10000 12000 14000 16000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.088 0.115 0.147 0.169 0.199 0.229 0.258 0.288 0.318 0.347 0.383 0.429 0.474 0.520 0.566 0.611 0.659 0.708 0.759
-34
motor 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1
1160 0.206 0.268 0.342 0.395 0.464 0.533 0.602 0.671 0.740 0.809 0.893 0.999 1.106 1.212 1.318 1.424 1.536 1.651 1.769
-27
motor 0.25 0.37 0.55 0.75 1.1 1.5 2.2
1750 0.708 0.920 1.174 1.355 1.593 1.830 2.067 2.304 2.542 2.779 3.066 3.431 3.796 4.161 4.526 4.890 5.272 5.668 6.073
-17
motor 0.75 1.1 1.5 2.2 3 4 5.5 7.5
3600 6.162 8.013 10.219 11.798 13.864 15.929 17.995 20.060 22.126 24.191 26.695 29.871 33.046 36.222 39.397 42.574 45.898 49.341 52.866
0
motor 7.5 11 15 18.5 22 30 37 45 55
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 17 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

79
PERFORMANCE TA-HP

60Hz
TA-HP-710-150-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
80
70 FEG71
60 34 36 38 40 42 44

50
32
30

40 28
26
30 24
22
20 18
20
16

sez. 10

2
0
Absorbed Power (kW)
1.0 30
0.4
3.0 25 44
0.8 42
0.3 2.5
20 40

0.6 2.0
38
36

0.2 15
1.5 34
0.4
32
30
10 28
1.0 24
26
0.1 22
0.2 5
20
0.5 16
18

0.0 0.0 0.0 0


Static Pressure (Pa)
1600
90 160
350 Lw(A) at 3600 rpm
1400
80 140
300
70 1200
120

250
60 1000
100

50 200
800
80

40
150
600
60
30
100 400
40
20

50 200
10 20
Speed
Pa]
Pv[ 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44

0 0 0 0
3600
0 10000 20000 30000 40000 50000 60000 70000 2 Pole

1750
0 5000 10000 15000 20000 25000 30000 4 Pole

1160
0 5000 10000 15000 20000 6 Pole

875
0 2000 4000 6000 8000 10000 12000 14000 16000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° dB(A)
875 0.047 0.066 0.087 0.108 0.129 0.150 0.171 0.192 0.213 0.234 0.263 0.292 0.322 0.351 0.383
-34
motor 0.06 0.09 0.12 0.18 0.25 0.37 0.55
1160 0.109 0.155 0.203 0.252 0.301 0.350 0.398 0.447 0.496 0.545 0.613 0.681 0.749 0.818 0.892
-27
motor 0.12 0.18 0.25 0.37 0.55 0.75 1.1
1750 0.375 0.531 0.698 0.866 1.034 1.200 1.368 1.535 1.703 1.871 2.105 2.339 2.573 2.807 3.064
-17
motor 0.55 0.75 1.1 1.5 2.2 3 4
3600 3.261 4.621 6.079 7.538 8.998 10.450 11.908 13.367 14.826 16.284 18.323 20.361 22.400 24.438 26.673
0
motor 4 5.5 7.5 11 15 18.5 22 30
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 23 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

80
PERFORMANCE TA-HP

60Hz
TA-HP-710-240-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
80
70 FEG71
60
42 44
50
34 36 38 40
32
30
40 28
26
30 22
24
20
18
20 16

10
sez.

2
0
Absorbed Power (kW)
40
0.5 1.2 4 35 44

1.0 30 42
0.4
3
40
25
0.8 38

0.3 20 36
0.6 2 34

0.2 15 30
32

0.4
28
26

1 10 22
24

0.1 0.2
20
5 16
18

0.0 0.0 0 0
Static Pressure (Pa)
1800

100 400
Lw(A) at 3600 rpm
1600

150
1400
80
300
1200

60 1000
100

200
800

40
600

50
100
400
20

200
Speed
Pa]
Pv[ 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
0 0 0 0
3600
0 10000 20000 30000 40000 50000 60000 70000 2 Pole

1750
0 5000 10000 15000 20000 25000 30000 4 Pole

1160
0 5000 10000 15000 20000 6 Pole

875
0 2000 4000 6000 8000 10000 12000 14000 16000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° dB(A)
875 0.062 0.085 0.110 0.135 0.162 0.184 0.209 0.233 0.258 0.283 0.328 0.373 0.418 0.464 0.509
-34
motor 0.09 0.12 0.18 0.25 0.37 0.55
1160 0.143 0.199 0.256 0.314 0.378 0.428 0.486 0.544 0.601 0.659 0.763 0.868 0.974 1.080 1.187
-27
motor 0.18 0.25 0.37 0.55 0.75 1.1 1.5
1750 0.492 0.684 0.879 1.077 1.298 1.471 1.669 1.866 2.064 2.262 2.620 2.982 3.345 3.709 4.075
-17
motor 0.55 0.75 1.1 1.5 2.2 3 4 5.5
3600 4.287 5.954 7.649 9.379 11.300 12.804 14.526 16.247 17.969 19.689 22.812 25.958 29.118 32.292 35.479
0
motor 5.5 7.5 11 15 18.5 22 30 37
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 22 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

81
PERFORMANCE TA-HP

60Hz
TA-HP-710-240-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
80
70 FEG71
60
34 44
50 36 38 40 42
32
30
40 28
26
30 24
22
20
20
18
16

sez. 10

2
0
Absorbed Power (kW)
0.7 50
1.6
0.6 1.4 5 44
40 42
0.5 1.2 4 40

1.0 30
0.4 3
38

0.8 36
0.3 20 34
0.6 2 30
32

0.2 28
0.4
26
24
1 10 20
22
0.1 0.2 16
18

0.0 0.0 0 0
Static Pressure (Pa)
2500
250
140
Lw(A) at 3600 rpm
500
120 2000
200

100 400

1500
150
80
300

60 1000
100
200

40

50 500
100
20

Speed
Pa]
Pv[ 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44

0 0 0 0
3600
0 10000 20000 30000 40000 50000 60000 70000 80000 2 Pole

1750
0 10000 20000 30000 4 Pole

1160
0 5000 10000 15000 20000 25000 6 Pole

875
0 5000 10000 15000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° dB(A)
875 0.087 0.117 0.149 0.186 0.223 0.244 0.275 0.307 0.339 0.371 0.425 0.480 0.535 0.594 0.653
-34
motor 0.09 0.12 0.18 0.25 0.37 0.55 0.75
1160 0.203 0.273 0.347 0.433 0.519 0.568 0.642 0.716 0.790 0.864 0.991 1.118 1.248 1.384 1.522
-27
motor 0.25 0.37 0.55 0.75 1.1 1.5 2.2
1750 0.696 0.936 1.190 1.485 1.780 1.949 2.203 2.458 2.713 2.967 3.402 3.837 4.284 4.751 5.224
-17
motor 0.75 1.1 1.5 2.2 3 4 5.5
3600 6.059 8.152 10.360 12.928 15.499 16.965 19.182 21.398 23.614 25.831 29.618 33.405 37.293 41.362 45.479
0
motor 7.5 11 15 18.5 22 30 37 45 55
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 24 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

82
PERFORMANCE TA-HP

60Hz
TA-HP-710-240-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
80
70 FEG71
60 44
42
50 34 36 38
40

32
40 30
28
30 26
24
20 20
22
18
10 16
sez.

2
0
Absorbed Power (kW)
1.0 8 70
2.0 7 60
0.8
6 50
44
42
1.5 5
0.6 40 40

4 38

0.4 1.0 30
3
36

20
34
32
2 28 30

0.2 0.5 22
24 26

10
20
1 16 18

0.0 0.0 0 0
Static Pressure (Pa)
3500
200 350 800
Lw(A) at 3600 rpm
700 3000
300

150 600 2500


250

500
2000
200

100 400

150 1500

300

100 1000
50 200

50 500
100
Speed
Pa]
Pv[ 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44

0 0 0 0
3600
0 10000 20000 30000 40000 50000 60000 70000 80000 2 Pole

1750
0 10000 20000 30000 4 Pole

1160
0 5000 10000 15000 20000 25000 6 Pole

875
0 5000 10000 15000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° dB(A)
875 0.136 0.166 0.198 0.233 0.267 0.302 0.338 0.374 0.410 0.441 0.520 0.600 0.680 0.761 0.843
-34
motor 0.18 0.25 0.37 0.55 0.75 1.1
1160 0.317 0.387 0.462 0.542 0.623 0.703 0.786 0.870 0.954 1.027 1.211 1.397 1.585 1.774 1.964
-27
motor 0.37 0.55 0.75 1.1 1.5 2.2
1750 1.087 1.327 1.586 1.860 2.137 2.414 2.700 2.988 3.277 3.526 4.159 4.798 5.443 6.091 6.742
-17
motor 1.1 1.5 2.2 3 4 5.5 7.5
3600 9.466 11.555 13.806 16.195 18.607 21.019 23.505 26.015 28.525 30.697 36.202 41.767 47.381 53.022 58.694
0
motor 11 15 18.5 22 30 37 45 55 75
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 21 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

83
PERFORMANCE TA-HP

60Hz
TA-HP-800-297-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG63
60
50 52
48 50
34 46
40 36 38 40 42 44
32

30 30
28

20
26
24
22
10 20
sez. 18

2
16

0
Absorbed Power (kW)
4 120
1.6
12 100 52
1.4 50
3 10
1.2
48
80 46

1.0 8 44

2 60
42
0.8 6
40
38
0.6 40 36
4
1
34
0.4 28
30 32

20
26
2 22 24
0.2 16
18 20

0.0 0 0 0
Static Pressure (Pa)
5000
500
Lw(A) at 3600 rpm
250 1000
4000
400

200 800

3000
300

150 600

200 2000

100 400

100 1000
50 200
99
100
94
89 Speed
94
16 18 20 94 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
0 0 0 0
3600
0 20000 40000 60000 80000 100000 120000 2 Pole

1750
0 10000 20000 30000 40000 50000 4 Pole

1160
0 10000 20000 30000 6 Pole

875
0 5000 10000 15000 20000 25000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.159 0.230 0.302 0.374 0.446 0.518 0.590 0.662 0.734 0.806 0.777 0.883 0.989 1.095 1.201 1.306 1.412 1.518 1.624
-34
motor 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2
1160 0.369 0.535 0.703 0.871 1.039 1.207 1.375 1.542 1.710 1.878 1.811 2.057 2.304 2.551 2.797 3.044 3.291 3.537 3.784
-27
motor 0.37 0.55 0.75 1.1 1.5 2.2 3 4
1750 1.268 1.838 2.414 2.991 3.567 4.143 4.719 5.296 5.872 6.448 6.217 7.064 7.911 8.758 9.605 10.452 11.299 12.145 12.992
-17
motor 1.5 2.2 3 4 5.5 7.5 11 15
3600 11.040 16.001 21.018 26.035 31.051 36.068 41.085 46.102 51.118 56.135 54.126 61.498 68.871 76.243 83.615 90.988 98.360 105.73 113.105
2 0
motor 15 18.5 22 30 37 45 55 75 55 75 90 110 132
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
*• The A-weightedcertified
Performance sound ratings shown have
is for installation been
type calculated
D -Ducted per Ducted
inlet, AMCA International Standardratings
outlet. Performance 301. Values
do notshown arethe
include foreffectsof
inlet LwiAappurtenances
sound power levels for installation
(accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 27 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

84
PERFORMANCE TA-HP

60Hz
TA-HP-800-406-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG63
60
50 52
48 50
34 46
40 36 38 40 42 44
32

30 30
28

20
26
24
22
10 20
18
sez.

2
16

0
Absorbed Power (kW)
4 120
1.6
12 100 52
1.4 50
3 10
1.2
48
80 46

1.0 8 44

2 60
42
0.8 6
40
38
0.6 40 36
4
1
34
0.4 28
30 32

20
26
2 22 24
0.2 16
18 20

0.0 0 0 0
Static Pressure (Pa)
5000
500
Lw(A) at 3600 rpm
250 1000
4000
400

200 800

3000
300

150 600

200 2000

100 400

100 1000
50 200
98
94
93
Speed
96
16 18 20 96 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
0 0 0 0
3600
0 20000 40000 60000 80000 100000 120000 2 Pole

1750
0 10000 20000 30000 40000 50000 4 Pole

1160
0 10000 20000 30000 6 Pole

875
0 5000 10000 15000 20000 25000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.159 0.230 0.302 0.374 0.446 0.518 0.590 0.662 0.734 0.806 0.777 0.883 0.989 1.095 1.201 1.306 1.412 1.518 1.624
-34
motor 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2
1160 0.369 0.535 0.703 0.871 1.039 1.207 1.375 1.542 1.710 1.878 1.811 2.057 2.304 2.551 2.797 3.044 3.291 3.537 3.784
-27
motor 0.37 0.55 0.75 1.1 1.5 2.2 3 4
1750 1.268 1.838 2.414 2.991 3.567 4.143 4.719 5.296 5.872 6.448 6.217 7.064 7.911 8.758 9.605 10.452 11.299 12.145 12.992
-17
motor 1.5 2.2 3 4 5.5 7.5 11 15
3600 11.040 16.001 21.018 26.035 31.051 36.068 41.085 46.102 51.118 56.135 54.126 61.498 68.871 76.243 83.615 90.988 98.360 105.73 113.105
2 0
motor 15 18.5 22 30 37 45 55 75 55 75 90 110 132
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
•* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 26 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

85
PERFORMANCE TA-HP

60Hz
TA-HP-800-406-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
60
FEG53
50

40
50 52
30 46 48
34 36 38 40 42 44
32

20 28
30

26

10 20
22
24

sez.

2
16 18

0
Absorbed Power (kW)
2.5 6 20 180
160
5
2.0 140 52
15 50
4 120 46
48

1.5 100 44
3 10
42
80 40
1.0 38
2 60 36
34
5
32
40 28 30
0.5
26
1 20 22 24
20 16 18

0.0 0 0 0
Static Pressure (Pa)
350 1400 6000
600
Lw(A) at 3600 rpm
300 1200 5000
500

250 1000
4000
400

200 800

3000
300

150 600

200 2000
100 400

100 1000
50 200
95
Speed
a]
Pv[ P
97
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
0 0 0 0
3600
0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 2 Pole

1750
0 10000 20000 30000 40000 50000 4 Pole

1160
0 5000 10000 15000 20000 25000 30000 35000 6 Pole

875
0 5000 10000 15000 20000 25000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.302 0.403 0.505 0.606 0.707 0.808 0.909 1.011 1.112 1.052 1.178 1.306 1.436 1.569 1.703 1.838 1.974 2.112 2.251
-34
motor 0.37 0.55 0.75 1.1 1.5
1.1 1.5 2.2 3
1160 0.704 0.940 1.176 1.411 1.647 1.883 2.119 2.355 2.591 2.452 2.744 3.042 3.346 3.655 3.967 4.281 4.600 4.921 5.244
-27
motor 0.75 1.1 1.5 2.2 3 4 5.5
1750 2.417 3.227 4.037 4.846 5.656 6.466 7.276 8.085 8.895 8.419 9.420 10.446 11.490 12.550 13.620 14.700 15.794 16.896 18.006
-17
motor 3 4 5.5 7.5 11 15 18.5
3600 21.041 28.091 35.140 42.190 49.239 56.289 63.338 70.388 77.437 73.293 82.010 90.942 100.02 109.25 118.572 127.97 137.49 147.09 156.74
8 2 5 7 2 9 0
motor 22 30 37 45 55 75 90 75 90 110 132 160
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 28 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

86
PERFORMANCE TA-HP

60Hz
TA-HP-800-406-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
60
FEG53
50

40
52
30 48 50
44 46
40 42
34 36 38

20 32
30
28
10 24
26
22
sez.

2
18 20
16
0
Absorbed Power (kW)
200
2.5 6 20
5 150
52

2.0
50
15 48

4 46

1.5
44
100 42
3 10 40
38
1.0 36
2
50 32 34
5 26 28 30
0.5 1 16 18 20 22 24

0.0 0 0 0
Static Pressure (Pa)
5000
500
Lw(A) at 3600 rpm
250 1000
4000
400

200 800

3000
300

150 600

200 2000

100 400

100 1000
50 200
95

98 Speed
Pa ]
99
P v16[ 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
0 0 0 0
3600
0 20000 40000 60000 80000 100000 120000 2 Pole

1750
0 10000 20000 30000 40000 50000 4 Pole

1160
0 10000 20000 30000 6 Pole

875
0 5000 10000 15000 20000 25000 8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.388 0.504 0.620 0.736 0.721 0.819 0.917 1.015 1.113 1.211 1.360 1.508 1.656 1.804 1.952 2.100 2.249 2.399 2.551
-34
motor 0.55 0.75 1.1 1.5 2.2 3
1160 0.904 1.174 1.444 1.714 1.680 1.908 2.137 2.365 2.594 2.822 3.168 3.513 3.858 4.203 4.548 4.893 5.239 5.590 5.944
-27
motor 1.1 1.5 2.2 3 4 5.5 7.5
1750 3.105 4.032 4.959 5.885 5.767 6.552 7.337 8.121 8.906 9.691 10.876 12.061 13.246 14.430 15.615 16.800 17.989 19.194 20.408
-17
motor 4 5.5 7.5 11 15 18.5 22
3600 27.034 35.102 43.169 51.236 50.203 57.035 63.868 70.701 77.533 84.366 94.681 104.99 115.310 125.62 135.93 146.25 156.60 167.091 177.66
5 4 9 3 4 0 0
motor 30 37 45 55 75 90 110 132 160 185
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Page 25 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

87
PERFORMANCE TA-HP

60Hz
TA-HP-900-297-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
52
50 36
38
40 42 44 46 48 50

40
34
32
30
30 26
28

20
10
sez.

2
0
Absorbed Power (kW)
2.5 20
5 52
2.0
15
50

4 48

1.5
46
44
3 10 42

1.0 40
2 36
38

5
34
32
0.5
30
1 26
28

0.0 0 0
Static Pressure (Pa)
350 1400
600

Lw(A) at 1750 rpm


300 1200
500

250 1000

400

200 800
103

300 94

150 600
97
99

200 98
100 400
94
101

100
50 200

Speed
[ Pa]
Pv 26
98
28 30 32 34 36 96 38 40 42 44 46 48 50
100 52
0 0 0
1750
0 10000 20000 30000 40000 50000 60000 70000 80000
4 Pole

1160
0 10000 20000 30000 40000 50000
6 Pole

875
0 10000 20000 30000 40000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.527 0.647 0.796 0.945 1.094 1.243 1.392 1.319 1.492 1.666 1.839 2.012 2.185 2.358
-17
motor 0.55 0.75 1.1 1.5 2.2 3
1160 1.227 1.506 1.853 2.201 2.548 2.896 3.243 3.074 3.477 3.881 4.284 4.688 5.091 5.495
-10
motor 1.5 2.2 3 4 5.5
1750 4.213 5.172 6.364 7.557 8.750 9.942 11.135 10.553 11.939 13.324 14.710 16.095 17.481 18.867
0
motor 5.5 7.5 11 15
11 15 18.5 22
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 45 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

88
PERFORMANCE TA-HP

60Hz
TA-HP-900-406-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG60
60
50
38 52
40
40 42 44 46 48 50
36
34
32
30 26
28
30

20
10
sez.

2
0
Absorbed Power (kW)
3.0 7 25

2.5 6 20
52
50
5 48
2.0
15
46

4 44
1.5 42
3 10 40

1.0 36
38
2 32
34

5
30
0.5 1 26
28

0.0 0 0
Static Pressure (Pa)
300 1200
500
Lw(A) at 1750 rpm

250 1000

400

200 800

99
300
100

150 600 96

200
95
100 400 103

100

100
50 200

] Speed
[ Pa
Pv
26 28 30 32 34 36 38 40 42 44 46 48 50 52
96 98 102
0 0 0
1750
0 10000 20000 30000 40000 50000 60000 70000
4 Pole

1160
0 10000 20000 30000 40000
6 Pole

875
0 5000 10000 15000 20000 25000 30000 35000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.686 0.856 1.029 1.097 1.243 1.389 1.534 1.719 1.904 2.089 2.275 2.463 2.651 2.840
-17
motor 0.75 1.1 1.5 2.2 3
1160 1.599 1.994 2.397 2.557 2.896 3.235 3.575 4.005 4.435 4.867 5.302 5.738 6.177 6.617
-10
motor 2.2 3 4 5.5 7.5
1750 5.489 6.848 8.231 8.778 9.943 11.109 12.274 13.751 15.228 16.711 18.203 19.703 21.207 22.718
0
motor 5.5 7.5 11 15 18.5 22 30
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 44 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

89
PERFORMANCE TA-HP

60Hz
TA-HP-900-406-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG60
60
50

40 50 52
38 46 48
40 42 44
36
30 32
34

30
20 26
28

10
sez.

2
0
Absorbed Power (kW)
30
3.5 8
7 25
3.0 52
50
2.5 6 20 48

5
46
2.0 44
4 15 42
1.5 40
3 10 36
38
1.0 2 30
32
34

5
28
0.5 1
26

0.0 0 0
Static Pressure (Pa)
400 700 1600

Lw(A) at 1750 rpm


1400
600

300 1200
500

1000
99
400

200 800
101
300
600
100

97
103

200
100 400

100
200

Speed
[ Pa] 26 28 30 32 34 36 38 40 42 44 46 48 50 52
Pv 100 101 103
0 0 0
1750
0 10000 20000 30000 40000 50000 60000 70000 80000
4 Pole

1160
0 10000 20000 30000 40000 50000
6 Pole

875
0 10000 20000 30000 40000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.918 1.125 1.331 1.308 1.486 1.664 1.842 2.070 2.299 2.527 2.755 2.983 3.211 3.439
-17
motor 1.1 1.5 2.2 3 4
1160 2.139 2.620 3.101 3.047 3.462 3.877 4.293 4.824 5.355 5.887 6.418 6.949 7.481 8.012
-10
motor 2.2 3 4 5.5 7.5 11
1750 7.346 8.996 10.646 10.463 11.888 13.313 14.739 16.563 18.388 20.212 22.037 23.861 25.686 27.510
0
motor 7.5 11 15 18.5 22 30
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 46 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

90
PERFORMANCE TA-HP

60Hz
TA-HP-900-406-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG60
60
50

40
52
48 50
42 44 46
38 40
30 34
36

32
20 28
30
26
10
sez.

2
0
Absorbed Power (kW)
10 35
4
30
8
25
52
3 50
48
6 20 46
44
2 15 42
4 40

10
38
36
34
1 2 28
30
32

5
26

0 0 0
Static Pressure (Pa)
1800

Lw(A) at 1750 rpm


400 700 1600

1400
600

300 1200
500

1000
101
400

200 800
101
300 102 98
600

103
200
100 400

100
200
Speed
[Pa]
26 28 30 32 34 36 38 40 42 44 46 48 50 52
Pv 101 101 103
0 0 0
1750
0 10000 20000 30000 40000 50000 60000 70000 80000
4 Pole

1160
0 10000 20000 30000 40000 50000
6 Pole

875
0 10000 20000 30000 40000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.220 1.444 1.668 1.561 1.760 1.959 2.158 2.415 2.672 2.929 3.186 3.443 3.700 3.957
-17
motor 1.5 2.2 3 4
1160 2.843 3.365 3.886 3.637 4.101 4.564 5.028 5.627 6.226 6.824 7.424 8.022 8.621 9.220
-10
motor 3 4 5.5 7.5 11
1750 9.763 11.554 13.344 12.488 14.080 15.671 17.263 19.319 21.376 23.432 25.489 27.545 29.602 31.658
0
motor 11 15 18.5 22 30 37
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 43 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

91
PERFORMANCE TA-HP

60Hz
TA-HP-1000-297-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
52
50
50 38
40 42 44 46 48
36

40 32
34

30
30
28
26
20
10
sez.

2
0
Absorbed Power (kW)
30
3.5 8
7 25
3.0 52

6
50
2.5 20 48

5 46
2.0
4 15 44
42
1.5
3
40
10
1.0
38
36
2 32
34

5
30
0.5
28
1 26

0.0 0 0
Static Pressure (Pa)
350 1400
600

Lw(A) at 1750 rpm


300 1200
500

250 1000

400

200 800

115
300

150 600
109 107
108

200
100 400
104
108

100 108
50 200

] Speed
[Pa
Pv 26
106 28 30 32 34 36
104 38 40 42 44 46 48 50
108 52
0 0 0
1750
0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000
4 Pole

1160
0 10000 20000 30000 40000 50000 60000
6 Pole

875
0 10000 20000 30000 40000 50000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.649 0.796 0.970 1.159 1.348 1.537 1.726 1.774 2.035 2.297 2.559 2.820 3.082 3.344
-17
motor 0.75 1.1 1.5 2.2 3 4
1160 1.513 1.855 2.261 2.701 3.141 3.581 4.022 4.132 4.742 5.352 5.961 6.571 7.181 7.790
-10
motor 2.2 3 4 5.5 7.5 11
1750 5.195 6.371 7.762 9.274 10.785 12.297 13.809 14.188 16.282 18.375 20.468 22.562 24.655 26.748
0
motor 5.5 7.5 11 15 18.5 22 30
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 31 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

92
PERFORMANCE TA-HP

60Hz
TA-HP-1000-406-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG63
60
50
38 50 52
40 42 44 46 48
40
36
34
32
30
30
28
26

20
10
sez.

2
0
Absorbed Power (kW)
10 35
4
30 52
8 50

3 25 48

6
46
20 44

2
42
15
4 38
40

10 34
36

1 2 30
32

5
28
26

0 0 0
Static Pressure (Pa)
350 1400
600

Lw(A) at 1750 rpm


300 1200
500

250 1000

400

200 800
110

300
102
150 600
110 109

200 99
100 400 108

108
100
50 200

] Speed
[ Pa
Pv 26
106
28 30 32 34 36
100
38 40 42 44 46 48 50
109
52
0 0 0
1750
0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000
4 Pole

1160
0 10000 20000 30000 40000 50000 60000
6 Pole

875
0 10000 20000 30000 40000 50000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 0.861 1.040 1.278 1.517 1.756 1.994 2.233 2.277 2.561 2.847 3.135 3.424 3.713 4.003
-17
motor 1.1 1.5 2.2 3 4 5.5
1160 2.006 2.422 2.979 3.535 4.091 4.647 5.203 5.305 5.966 6.634 7.304 7.977 8.651 9.328
-10
motor 2.2 3 4 5.5 7.5 11
1750 6.888 8.317 10.227 12.136 14.045 15.955 17.864 18.216 20.485 22.777 25.079 27.389 29.704 32.026
0
motor 7.5 11 15 18.5 22 30 37
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 30 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

93
PERFORMANCE TA-HP

60Hz
TA-HP-1000-406-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG60
60
50
50 52
40 36
38 40 42 44 46 48

30 32
34

30
20 26
28

10
sez.

2
0
Absorbed Power (kW)
6 14 50

5 12 40
10
4
52
30 50
8 48
3 44
46

6 20 42

2 40
4 34
36
38

1 10 30
32

2 26
28

0 0 0
Static Pressure (Pa)
1800

Lw(A) at 1750 rpm


400 700 1600

1400
600

300 1200
500

106
1000
400
106 108
200 800

300
109 103
600
101

200
100 400
107

100
200
Speed
[P a]
Pv 106
26 28 30 32 34 36
101
38 40 42 44 46 48 50
103 52
0 0 0
1750
0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000
4 Pole

1160
0 10000 20000 30000 40000 50000 60000
6 Pole

875
0 10000 20000 30000 40000 50000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.109 1.392 1.707 2.022 2.337 2.652 2.967 2.776 3.092 3.421 3.757 4.097 4.440 4.785
-17
motor 1.5 2.2 3 4 5.5
1160 2.584 3.243 3.977 4.711 5.445 6.178 6.912 6.469 7.203 7.970 8.753 9.546 10.345 11.150
-10
motor 3 4 5.5 7.5 11 15
1750 8.872 11.136 13.656 16.175 18.694 21.214 23.733 22.210 24.733 27.366 30.055 32.775 35.520 38.283
0
motor 11 15 18.5 22 30 37 45
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 32 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

94
PERFORMANCE TA-HP

60Hz
TA-HP-1000-406-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG60
60
50
52
40 48 50
38 40 42 44 46
36
30 34
32
20 30
28
26
10
sez.

2
0
Absorbed Power (kW)
6 14 50

5 12 40
10
52

4 50
30 48
8 46
3 44

6 20 40
42

2
4 32 34
36 38

1 10 28
30
2
26

0 0 0
Static Pressure (Pa)
2500
600
1000
Lw(A) at 1750 rpm

500 2000

800

400
1500

600
113
300

1000 109 113


400
200 103

109 107

500
200 108
100

Speed
P a]
Pv[ 26
107 28 30 32 34 36 106 38 40 42 44 46 48 50
104 52
0 0 0
1750
0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000
4 Pole

1160
0 10000 20000 30000 40000 50000 60000
6 Pole

875
0 10000 20000 30000 40000 50000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.467 1.773 2.079 2.384 2.690 2.996 3.301 3.200 3.563 3.926 4.289 4.651 5.014 5.377
-17
motor 1.5 2.2 3 4 5.5
1160 3.419 4.131 4.843 5.555 6.267 6.979 7.692 7.456 8.301 9.147 9.992 10.838 11.683 12.529
-10
motor 4 5.5 7.5 7.5 11 11 15
1750 11.738 14.183 16.628 19.074 21.519 23.964 26.410 25.599 28.503 31.406 34.309 37.212 40.115 43.018
0
motor 15 18.5 22 30 37 45
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 29 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

95
PERFORMANCE TA-HP

60Hz
TA-HP-1120-297-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60 52
50
50 44
46
48

40 42
38
40 36

30
34
32

20
30
28
26
10
sez.

2
0
Absorbed Power (kW)
5 40
10 52
4
30
50

8 48
46
3 44
6 20 42

2
40

4 34
36 38
32
10 28
30
1
26
2

0 0 0
Static Pressure (Pa)
350 1400
600

Lw(A) at 1750 rpm


300 1200
500

250 1000

400
107

200 800

300

150 600 99
104
109

200 103
103
100 400

105
100
50 200

] Speed
[Pa
Pv 26
104 28 30 32 34 36 10038 40 42 44 46 48 104
50 52
0 0 0
1750
0 20000 40000 60000 80000 100000 120000 140000
4 Pole

1160
0 10000 20000 30000 40000 50000 60000 70000 80000 90000
6 Pole

875
0 10000 20000 30000 40000 50000 60000 70000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.125 1.298 1.474 1.672 1.882 2.092 2.301 2.579 2.932 3.287 3.641 3.995 4.349 4.704
-17
motor 1.5 2.2 3 4 5.5
1160 2.621 3.024 3.434 3.895 4.384 4.873 5.362 6.008 6.832 7.659 8.483 9.309 10.134 10.959
-10
motor 3 4 5.5 7.5 11
1750 8.998 10.383 11.789 13.375 15.053 16.732 18.410 20.628 23.458 26.297 29.128 31.962 34.795 37.629
0
motor 11 15 18.5 22 30 37 45
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 35 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

96
PERFORMANCE TA-HP

60Hz
TA-HP-1120-406-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG63
60
52
50 44 46 48
50
38 40 42

40 36
34
30 32
30
20 26
28

10
sez.

2
0
Absorbed Power (kW)
6 14 50

5 12 40 52
50
10
4
48
30 46
8 44
3 42
6 20 40

2
38
36
4 30
32
34

10
28
1
26
2
0 0 0
Static Pressure (Pa)
400 700 1600

Lw(A) at 1750 rpm


1400
600

300 1200
500

1000
108
400

200 800

300 104
107

600 104

101
106
200
100 400

105
100
200

] Speed
[Pa
Pv 26
104 28 30 32 34 36
101 38 40 42 44 46 48 105 52
50
0 0 0
1750
0 20000 40000 60000 80000 100000 120000 140000
4 Pole

1160
0 10000 20000 30000 40000 50000 60000 70000 80000 90000
6 Pole

875
0 10000 20000 30000 40000 50000 60000 70000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.291 1.514 1.765 2.022 2.286 2.557 2.827 3.170 3.547 3.925 4.303 4.680 5.059 5.438
-17
motor 1.5 2.2 3 4 5.5
1160 3.009 3.527 4.113 4.711 5.327 5.957 6.587 7.387 8.265 9.145 10.025 10.905 11.788 12.670
-10
motor 4 5.5 7.5 11 15
1750 10.331 12.111 14.121 16.175 18.289 20.453 22.618 25.363 28.379 31.400 34.421 37.442 40.473 43.504
0
motor 11 15 18.5 22 30 37 45
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 34 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

97
PERFORMANCE TA-HP

60Hz
TA-HP-1120-406-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG63
60
50 48
50
52

44 46
38 40 42
40
36

30 34
32
20 30
28
10 26
sez.

2
0
Absorbed Power (kW)
60
7 16
14 50
6
52
50

5 12 40 48

10
46
4 44
8 30 42
3 40
6 20 36 38
2 4 28 30
32 34

10
26
1 2
0 0 0
Static Pressure (Pa)
500 2000

800
Lw(A) at 1750 rpm

400 700
1500

600
106

300
500
110
1000
400
103
200 109
106
300
106

500
200
100
107

100
Speed
[Pa ]
Pv 26
107
28 30 32 34 36
103 38 40 42 44 46 48 50
107 52
0 0 0
1750
0 20000 40000 60000 80000 100000 120000 140000
4 Pole

1160
0 10000 20000 30000 40000 50000 60000 70000 80000 90000
6 Pole

875
0 10000 20000 30000 40000 50000 60000 70000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.593 1.904 2.254 2.616 2.978 3.341 3.703 3.849 4.354 4.863 5.372 5.881 6.390 6.899
-17
motor 2.2 3 4 5.5 7.5
1160 3.712 4.437 5.251 6.095 6.940 7.784 8.628 8.969 10.145 11.331 12.517 13.703 14.888 16.074
-10
motor 4 5.5 7.5 11 15 18.5
1750 12.745 15.236 18.031 20.929 23.827 26.725 29.623 30.795 34.833 38.904 42.976 47.048 51.119 55.191
0
motor 15 18.5 22 30 37 45 55 75
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 36 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

98
PERFORMANCE TA-HP

60Hz
TA-HP-1120-406-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG63
60
50 48
50
52

46
44
40 38 40 42

36
30
34

20 32
30

10
28
26
sez.

2
0
Absorbed Power (kW)
20 70
8
60
7
15 50
52

6 50
48
5 40 46

10 44
4 30 42
40
3
20
38
36
5
34
2
32
28 30
26

1 10

0 0 0
Static Pressure (Pa)
2500
600
1000
Lw(A) at 1750 rpm

500 2000

800

400 105

1500

600
110
300
102

1000
111
400 106
106
200

500
200 108
100

Speed
[ Pa]
Pv 26
108 28 30 32 34 36
105 38 40 42 44 46 48 50107 52
0 0 0
1750
0 20000 40000 60000 80000 100000 120000 140000
4 Pole

1160
0 10000 20000 30000 40000 50000 60000 70000 80000 90000
6 Pole

875
0 10000 20000 30000 40000 50000 60000 70000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.854 2.218 2.617 3.022 3.427 3.833 4.238 4.537 5.145 5.753 6.361 6.975 7.596 8.221
-17
motor 2.2 3 4 5.5 7.5 11
1160 4.319 5.167 6.096 7.041 7.985 8.930 9.874 10.570 11.987 13.404 14.822 16.251 17.699 19.156
-10
motor 5.5 7.5 11 15 18.5 22
1750 14.829 17.742 20.932 24.174 27.417 30.660 33.902 36.292 41.158 46.024 50.890 55.799 60.771 65.771
0
motor 15 18.5 22 30 37 45 55 75
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 33 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

99
PERFORMANCE TA-HP

60Hz
TA-HP-1250-297-6-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60 52
50
48
50 38 40 42 44 46

36
40
34

30 32
30
20 28
26
10
sez.

2
0
Absorbed Power (kW)
60
7 16
14 50
6 52

5 12 40
50
48
10 46
4
8 30 44
42
3
6
40
20 38
2 4 30 32 34
36
28
10
26
1 2
0 0 0
Static Pressure (Pa)
350 1400
600

Lw(A) at 1750 rpm


112
300 1200
500

250 1000

400

200 800

300

150 600

200
100 400

100
50 200

] Speed
[ Pa
Pv 26 28 30 32 34 36 38 40 42 44 46 48 50 52
0 0 0
1750
0 20000 40000 60000 80000 100000 120000 140000 160000
4 Pole

1160
0 20000 40000 60000 80000 100000
6 Pole

875
0 10000 20000 30000 40000 50000 60000 70000 80000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.392 1.646 1.902 2.160 2.421 2.692 2.965 3.435 3.923 4.415 4.910 5.404 5.899 6.393
-17
motor 1.5 2.2 3 4 5.5 7.5
1160 3.244 3.836 4.433 5.032 5.641 6.272 6.908 8.004 9.140 10.286 11.440 12.592 13.744 14.895
-10
motor 4 5.5 7.5 11 15
1750 11.138 13.170 15.219 17.276 19.368 21.536 23.720 27.483 31.383 35.319 39.281 43.235 47.190 51.144
0
motor 15 18.5 22 30 37 45 55
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 39 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

100
PERFORMANCE TA-HP

60Hz
TA-HP-1250-406-12-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
52
50
50
38 46 48
40 42 44
36
40 34
32
30 30
28
20 26

10
sez.

2
0
Absorbed Power (kW)
20 70
8
60
7 52
15 50
6
50
48

5 40 46

10 44
4 30 42
40
3
20 36
38
5
34
2 28 30
32

10
26
1
0 0 0
Static Pressure (Pa)
400 700 1600

Lw(A) at 1750 rpm


1400
600

300 1200
500

1000

400

200 800

300
600

200
100 400

100
200

] Speed
[ Pa
Pv 26 28 30 32 34 36 38 40 42 44 46 48 50 52

0 0 0
1750
0 20000 40000 60000 80000 100000 120000 140000 160000 180000
4 Pole

1160
0 20000 40000 60000 80000 100000
6 Pole

875
0 10000 20000 30000 40000 50000 60000 70000 80000 90000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.596 1.898 2.219 2.541 2.865 3.188 3.512 4.031 4.601 5.193 5.794 6.401 7.010 7.621
-17
motor 2.2 3 4 5.5 7.5 11
1160 3.718 4.422 5.170 5.920 6.674 7.429 8.183 9.392 10.721 12.099 13.500 14.914 16.332 17.757
-10
motor 4 5.5 7.5 11 15 18.5
1750 12.766 15.184 17.751 20.326 22.916 25.507 28.098 32.248 36.811 41.543 46.353 51.208 56.078 60.967
0
motor 15 18.5 22 30 37 45 55 75
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 38 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

101
PERFORMANCE TA-HP

60Hz
TA-HP-1250-406-12-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
52
50
50
48
46
38 40 42 44

40 36

30 34
32

20 30
28

10 26
sez.

2
0
Absorbed Power (kW)
90
25
10 80
20 70 52
8
60 48
50

15 50
6 46
44
40 42
4 10
30 38
40
36
20 32 34
2 5 26 28 30

10
0 0 0
Static Pressure (Pa)
500 2000

800
Lw(A) at 1750 rpm

400 700
1500

600

300
500

1000
400

200

300

500
200
100

100

] Speed
[P a
Pv 26 28 30 32 34 36 38 40 42 44 46 48 50 52
0 0 0
1750
0 20000 40000 60000 80000 100000 120000 140000 160000 180000
4 Pole

1160
0 20000 40000 60000 80000 100000
6 Pole

875
0 10000 20000 30000 40000 50000 60000 70000 80000 90000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 1.770 2.234 2.701 3.167 3.634 4.101 4.567 5.246 5.974 6.718 7.471 8.225 8.979 9.734
-17
motor 2.2 3 4 5.5 7.5 11
1160 4.125 5.205 6.292 7.380 8.467 9.555 10.642 12.223 13.918 15.653 17.407 19.165 20.922 22.679
-10
motor 5.5 7.5 11 15 18.5 22 30
1750 14.162 17.872 21.604 25.339 29.073 32.806 36.540 41.966 47.789 53.747 59.769 65.802 71.835 77.869
0
motor 15 18.5 22 30 37 45 55 75 90
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 40 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

102
PERFORMANCE TA-HP

60Hz
TA-HP-1250-406-12-12
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
50 50
52
48
46
40 42 44
38 40

36
30
34

20 32
30
10 28
26
sez.

2
0
Absorbed Power (kW)
12 100
25
10 80 52
20 50
8
60 46
48

6 15 44

40 42

4 10 40
36 38
34
20 30 32
2 5 26 28

0 0 0
Static Pressure (Pa)
2500
600
1000
Lw(A) at 1750 rpm

500 2000

800

400
1500

600

300

1000
400
200

500
200
100

Speed
[ Pa]
Pv 26 28 30 32 34 36 38 40 42 44 46 48 50 52

0 0 0
1750
0 50000 100000 150000 200000
4 Pole

1160
0 20000 40000 60000 80000 100000 120000
6 Pole

875
0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
26° 28° 30° 32° 34° 36° 38° 40° 42° 44° 46° 48° 50° 52° dB(A)
875 2.104 2.619 3.134 3.674 4.219 4.765 5.310 6.132 7.044 7.967 8.889 9.810 10.732 11.654
-17
motor 2.2 3 4 5.5 7.5 11 15
1160 4.903 6.103 7.303 8.561 9.831 11.102 12.372 14.288 16.412 18.562 20.710 22.857 25.005 27.153
-10
motor 5.5 7.5 11 15 18.5 22 30
1750 16.833 20.955 25.076 29.393 33.755 38.118 42.481 49.059 56.352 63.734 71.108 78.481 85.855 93.229
0
motor 18.5 22 30 37 45 55 75 90 110
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 37 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

103
PERFORMANCE TA-HP

60Hz
TA-HP-1400-523-9-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
70
FEG67
60
44
50 40 42
30 32 36 38
34
28
40 26
24
30 22
20

20
18
16

10
sez.

2
0
Absorbed Power (kW)
160
40 140
15
44

120
42
40
30 100 38

10 36
80 34
20 32
60 28
30

5 40 24
26
10 20
22

20
18
16

0 0 0
Static Pressure (Pa)
2500

1000
Lw(A) at 1750 rpm
500
2000

800
400

1500

600
300

1000
400
200

500
100 200 98

95
91
93
89 Speed
93 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
88
0 0 0
1750
0 50000 100000 150000 200000 250000 300000
4 Pole

1160
0 50000 100000 150000
6 Pole

850
0 20000 40000 60000 80000 100000 120000 140000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° dB(A)
850 2.778 3.620 4.478 5.464 6.466 7.468 8.469 9.471 9.852 11.083 12.314 13.544 14.775 16.006 17.237
-17
motor 3 4 5.5 7.5 11 15 18.5
1160 7.062 9.202 11.382 13.888 16.434 18.980 21.526 24.072 25.040 28.168 31.297 34.425 37.554 40.682 43.811
-10
motor 7.5 11 15 18.5 22 30 37 45
1750 24.247 31.595 39.081 47.685 56.427 65.168 73.910 82.652 85.976 96.717 107.45 118.200 128.94 139.68 150.42
9 2 3 5 0
motor 30 37 45 55 75 90 110 132 160
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 41 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

104
PERFORMANCE TA-HP

60Hz
TA-HP-1400-523-9-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
80
70 FEG71
60
44
50 38 40
42
30 32 34 36

40 28
26
30 24
22
20 18
20

16
10
sez.

2
0
Absorbed Power (kW)
70 250
25
60 200
20 50 44
42
150
40
40
15 38
36
30 100 34
10 32
20 28 30
50
26
5 22 24
10 16 18 20

0 0 0
Static Pressure (Pa)
4000
900
Lw(A) at 1750 rpm
3500
800 1500

700 3000

600 2500

1000
500
2000

400
1500

300
500
1000
200

96
500 99
100 91
94 96
Speed
95 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
91
0 0 0
1750
0 50000 100000 150000 200000 250000 300000
4 Pole

1160
0 50000 100000 150000
6 Pole

850
0 20000 40000 60000 80000 100000 120000 140000
8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° dB(A)
850 4.286 5.191 6.315 7.532 8.748 9.965 11.182 12.399 12.854 14.630 16.405 18.180 19.955 21.731 23.506
-17
motor 5.5 7.5 11 15 18.5 22 30
1160 10.893 13.194 16.050 19.143 22.235 25.328 28.421 31.514 32.671 37.183 41.696 46.208 50.720 55.232 59.744
-10
motor 11 15 18.5 22 30 37 45 55 75
1750 37.402 45.302 55.108 65.727 76.346 86.966 97.585 108.20 112.177 127.67 143.163 158.65 174.148189.641 205.13
4 0 5 3 0
motor 45 55 75 90 110 132 160 185 200 0
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 42 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

105
PERFORMANCE TA-HP

60Hz
TA-HP-1600-523-9-6
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
80
70 FEG75
60
44
50 30 38
40
42
32 34 36

40 28
26
30 24

20 20
22

10 18
sez. 16

2
0
Absorbed Power (kW)
70
25
60
44
20 50 42
40

15 40 38
36

30 34
10 32
20 28
30
24 26
5 22
10 18 20
16

0 0
Static Pressure (Pa)
1200

600 Lw(A) at 1160 rpm

1000

500

800
400

600
300

99
400
200
100

100 200 92

94 95
95
Speed
96
97 16 18 20 22 94
24 26 28 30 32 34 36 38 40 42 44
0 0
1160
0 50000 100000 150000 200000 250000 6 Pole

0 50000 100000 150000 850


8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38° 40° 42° 44° dB(A)
850 2.970 3.918 5.020 6.162 7.309 8.457 9.608 10.758 12.452 14.176 15.995 17.844 19.709 21.583 23.462
-7
motor 3 4 5.5 7.5 11 15 18.5 22 30
1160 7.549 9.958 12.759 15.662 18.576 21.496 24.419 27.343 31.649 36.032 40.655 45.355 50.093 54.857 59.632
0
motor 11 15 18.5 22 30 37 45 55 75
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 47 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

106
PERFORMANCE TA-HP

60Hz
TA-HP-1600-523-9-9
p = 1.2kg/m3
AXIAL FLOW FAN
Total Efficiency (%)
80
70 FEG75
60 36

50
34
32
30
40
28
30 26

20 22
24

10 20
18
sez.

2
16

0
Absorbed Power (kW)
80
30
70
25
60
20 50

15 40 36
34
30 32
10 30
20 26 28
22 24
5 10 16
18 20

0 0
Static Pressure (Pa)
2000

1000 Lw(A) at 1160 rpm

800 1500

600

1000

400

104

500 101
102
200 101

83
97
94
123 Speed
97
98 16 18 20 22 24 97 26 28 96
30 32 34 36
0 0
1160
0 50000 100000 150000 200000 250000 6 Pole

0 50000 100000 150000 850


8 Pole
Air Volume (m3/h)

Peak Absorbed Power (Kw)


Blade Pitch Angle [°] LwA
N(rpm)
16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° dB(A)
850 4.026 5.146 6.639 8.130 9.626 11.122 12.616 14.111 18.036 22.410 26.785
-7
motor 5.5 7.5 11 15 18.5 30
1160 10.232 13.080 16.874 20.663 24.466 28.268 32.066 35.864 45.840 56.959 68.079
0
motor 11 15 18.5 22 30 37 55 75
* Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
* The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

• Performance certified is for installation type D -Ducted inlet, Ducted outlet. Performance ratings do not include the effectsof appurtenances (accessories).
Page 48 of 48
• The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. Values shown are for inlet LwiA sound power levels for installation
type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

107
DIMENSIONS TA-HP

sez.

2
TYPE A ØB ØC ØD E F N Ø Kg
TA-HP 400 450 400 450 502 290 50 8 12 14
TA-HP 450 450 450 500 553 315 50 8 12 16
TA-HP 500 575 500 560 603 355 53 12 12 23
TA-HP 560 575 560 620 663 380 50 12 12 26
TA-HP 630 725 630 690 733 420 75 12 12 47
TA-HP 710 600 710 770 813 437 75 16 12 42
TA-HP 800 650 800 860 903 485 70 16 12 49
TA-HP 900 770 900 970 1013 565 70 16 16 70
TA-HP 1000 840 1000 1070 1113 610 70 20 16 112
TA-HP 1120 840 1120 1190 1233 675 150 20 16 123
TA-HP 1250 1090 1250 1320 1367 730 150 20 16 175
TA-HP 1400* 1350 1400 1470 1530 850 150 20 16 350
TA-HP 1600* 1350 1600 1680 1730 930 150 24 18 400
Dimensions in mm
Above mentioned models are excluding motor weights.
* For motor FS 315 S/M and above, check with sales office for actual drawing.
^ TA HP 1800 and 2000 mm upon request.

ACCESSORIES

INLET/OUTLET CONE CCbo

It allows a higher fan efficiency in case of installation with inlet or outlet not ducted. Manu- TYPE A B C D E F G H I L kg
factured in steel sheet with one flange according to UNI ISO6580 – EUROVENT to be fitted CCbo 40 175 546 450 500 8 12 8 12 407 496 5,6
to the CC fan and an aerodynamically shaped bell mouth with fixing holes for a protection CCbo 45 175 598 500 560 12 12 8 12 457 546 6,3
guard (of one size bigger, example CCbo 71 + CCr 80). Protected against atmospheric CCbo 50 190 658 560 620 12 12 12 12 507 598 8,5
agents by epoxy paint. CCbo 56 190 730 620 690 12 12 12 12 567 730 8,5
CCr di una taglia superiore
CCr of one size bigger
CCbo 63 190 810 690 770 16 12 12 12 637 810 9,8
CC CCbo CCbo 71 230 910 770 860 16 12 16 12 708 910 12,4
N°E FORI ØF CCbo 80 250 1025 860 970 16 16 16 12 808 1025 15,2
N°G FORI ØH
CCbo 90 300 1125 970 1070 16 16 16 16 910 1125 29,4
CCbo 100 300 1245 1070 1190 20 16 16 16 1010 1245 33,3
CCbo 112 300 1380 1190 1320 20 16 20 16 1130 1380 37,3
ØB
ØL

ØD
ØC
ØI

CCbo 125 300 1525 1320 1470 20 16 20 16 1260 1525 42,5


Dimensions in mm
Indicative weights
A ØC Air flow A
ØD
Installation example

108
ACCESSORIES TA-HP

FLEXIBLE CONNECTORS CCga-HT

It prevents the propagation of vibrations along the ducted system. Manufactured with TYPE A ØB ØC ØD E ØF kg
two flanges in steel sheet, according to UNI ISO6580 – EUROVENT standard for CCga-HT 40 200 400 450 496 8 12 7
fixing to the fan and to the duct, and a strong flexible fabric joint. Suitable for high CCga-HT 45 200 450 500 546 8 12 8
temperature working. Components in steel sheet are protected against atmospheric CCga-HT 50 200 500 560 598 12 12 9
agents by epoxy paint. CCga-HT 56 200 560 620 658 12 12 10
CCga-HT 63 200 630 690 730 12 12 11
CCga-HT 71 200 710 770 810 16 12 13
CCga-HT 80 200 800 860 910 16 12 21
CCga-HT 90 200 900 970 1030 16 16 23
CCga-HT 100 200 1000 1070 1130 16 16 26
CCga-HT 112 200 1120 1190 1250 20 16 29 sez.

2
CCga-HT 125 200 1250 1320 1380 20 16 32
Dimensions in mm
Indicative weights

PROTECTION GUARDS CCr

TYPE ØA Kg
They prevent from casual contact with moving parts of the fan. Manufactured in steel rod CCr 40 450 0,8
and protected against atmospheric agents. CCr: flat version (for long case and short case CCr 45 500 1,0
on impeller side). CCr 50 560 1,3
CCr 56 620 1,6
CCr 63 690 1,9
CCr 71 770 2,2
CCr 80 860 3,0
CCr 90 970 3,4
CCr 100 1070 3,5
CCr 112 1190 4,0
CCr 125 1320 4,5
Dimensions in mm
Indicative weights

COUNTER FLANGE WITH COLLAR CCfc

Counter flange with addition of 80 mm of round duct, is used for easier connection TYPE ØA ØB C ØD Kg
between the CC fan and the duct. CCfc 40 400 450 8 12 1,7
CCfc 45 450 500 8 12 2
CCfc 50 500 560 12 12 2,2
CCfc 56 560 620 12 12 2,5
CCfc 63 630 690 12 12 2,9
CCfc 71 710 770 16 12 3,3
CCfc 80 800 860 16 12 3,8
CCfc 90 900 970 16 16 4,2
CCfc 100 1000 1070 16 16 5
CCfc 112 1120 1190 20 16 5,8
CCfc 125 1250 1320 20 16 6,5
Dimensions in mm
Indicative weights

COUNTER FLANGE CCf

Ring plate with holes according to UNI ISO6580 – EUROVENT standard, compatible with TYPE ØA ØB C ØF Kg
fan flange. It is used for easier connection between the CC fan and the duct. CCf 40 400 450 8 12 1,7
CCf 45 450 500 8 12 1,9
CCf 50 500 560 12 12 2,1
CCf 56 560 620 12 12 2,4
CCf 63 630 690 12 12 2,7
CCf 71 710 770 16 12 3,3
CCf 80 800 860 16 12 3,7
CCf 90 900 970 16 16 4,7
CCf 100 1000 1070 16 16 5,2
CCf 112 1120 1190 20 16 6,5
CCf 125 1250 1320 20 16 8
Dimensions in mm
Indicative weights

109
3
part

SISW BACKWARD CURVED BELT


DRIVEN CENTRIFUGAL FANS

PRL-TC Pg. 113


SISW Backward Curved Belt Driven Centrifugal Fans

sez.

111
PRL-TC
SISW Backward Curved Belt Driven Centrifugal Fans

GENERAL DESCRIPTION
SISW non-overload backward curved centrifugal fan sizes are in accordance with AMCA 99-16.

The fans of the PRL-TC series find their main application in commercial and industrial plants
of air-conditioning, ventilation, heating and filtering. They can be used in industrial processing
(baker ovens, spray booths, driers, boilers, silos, cooling systems, etc.) as well.

PRL-TC fans can convey clean or slightly dusty air and smoke with maximum temperature of
180ºC.

Suitable for very high capacities and high pressure.

Airflow range : 3,400 to 84,000 CMH sez.

External static pressure : 200 to 1,400 Pa


3
PRL TC Series CONSTRUCTION
• Volute casing: steel sheet is protected against atmospheric agents by epoxy paint.
• Aerodynamically shaped inlet cone in steel sheet is protected against atmospheric agents by
epoxy paint.

IMPELLER
• Single inlet single width backward curved wheel with high efficiency at higher pressure gradi
ent, manufactured in steel sheet and protected against atmospheric agents by epoxy paint.
• For high rotational speed, versions in class III are foreseen. Mono-block support in cast iron
with ball bearings, designed for easy lubrication for L10 life more than 100,000 Hr.

MOTOR
• Asynchronous three-phase motors according to international standards IEC 60034, IEC
60072, IP 55, class F, (continuous working at constant load), suitable to S1 service.
• Asynchronous three-phase motors according to international standards IEC 60034, IEC
60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, (continuous working
at constant load), suitable to S1 service.
PRL TC, R & E Series
ACCESSORIES
• Condensation drain hole (TS)
• Inspection door (PI)-Position 1, Position 2, Position 3
• Inlet counter-flange (CFA)
• Outlet counter-flange (CFP)
• Anti-vibration mounts
• Belt guard

AMCA Sound & Air Performance Seal


PRL - TC shown herein is licensed to bear the
AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
with AMCA publication 211 and AMCA 311 and
comply with the requirements of the AMCA
Certified Ratings Program.

113
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

EXAMPLE OF SELECTION

Air Volume Q 6660m³/h


Op Limt CI.I CI.II CI.III
Outlet Velocity V 6.77 m/s

Dynamic Pressure Pa 27 Pa
Typ C-U-P T-U-P X-U-P
Total Pressure Pt 1250 Pa

Fan Speed N 1510 rpm Outlet


M.kW 6 13 26
Absorbed Power W 3.22 kW

Total Efficiency 71.8%


M. RPM 1800 2300 2900
sez. Sound Power Level w(A) 81.3 dB (A)

3
sez.

pag. 69

114
ASSEMBLY DIMENSIONS PRL-TC

DIRECTION OF ROTATION
The above series are divided into direction of rotations left-hand rotation (LH) and right hand rotation (RH). Viewing from end of motor outlet line, if the
impeller rotates clockwise, it is called right hand ventilator; If the impeller rotates anti-clockwise, it is called left hand ventilator.

0° 90° 180° 270°

LEFT
HAND
sez.

3
RIGHT
HAND

DIRECTION OF AIR OUTLET


Its made into four air-oulet directions 0°, 90°, 180° and 270°

STANDARD ORIENTATION
LH-180°

TYPE OF STRUCTURE

TYPE
R

TYPE
E

TYPE
C

Blower can be divided into series R,E and C. The above series are selected based upon on the fan duty, rpm and also application.

115
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 315 R
Q max Min Max Max frame
Type Model E, C
(m³/h) (Pa) (RPM) Size

PRL-TC 315 6900 90 4000 132 DO NOT USE IN THIS AREA

sez.

3
sez.

pag. 69
)
W
(K
w
Bk

116
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 355 R
Q max Min Max Max frame
Type Model E, C
(m³/h) (Pa) (RPM) Size

PRL-TC 355 9100 89 3800 132 DO NOT USE IN THIS AREA

sez.

3
)
W
(K
w
Bk

117
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 400 R
Q max Min Max Max frame
Type Model E, C
(m³/h) (Pa) (RPM) Size

PRL-TC 400 11000 40 3200 160 DO NOT USE IN THIS AREA

sez.

3
sez.

pag. 69
)
W
(K
w
Bk

118
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 450 R
Q max Min Max Max frame
Type Model E, C
(m³/h) (Pa) (RPM) Size

PRL-TC 450 13900 98 2800 160 DO NOT USE IN THIS AREA

sez.

3
)
W
(K
w
Bk

119
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 500 R
Q max Min Max Max frame
Type Model E, C
(m³/h) (Pa) (RPM) Size

PRL-TC 500 19000 100 2800 160 DO NOT USE IN THIS AREA

sez.

3
sez.

pag. 69
)
W
(K
w
Bk

120
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 560 R
Q max Min Max Max frame
Type Model (m³/h) (Pa) (RPM) Size

PRL-TC 000 25000 70 2000 180 DO NOT USE IN THIS AREA

sez.

3
)
W
(K
w
Bk

121
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 630 R
Q max Min Max Max frame
Type Model E, C
(m³/h) (Pa) (RPM) Size

PRL-TC 630 29000 125 2200 200 DO NOT USE IN THIS AREA

sez.

3
sez.

pag. 69
)
W
(K
w
Bk

122
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 710 R
Q max Min Max Max frame
Type Model E, C
(m³/h) (Pa) (RPM) Size

PRL-TC 710 38000 80 2000 225 DO NOT USE IN THIS AREA

sez.

3
)
W
(K
w
Bk

123
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 800 R
Q max Min Max Max frame
Type Model (m³/h) (Pa) (RPM) Size

PRL-TC 800 45000 100 1600 250 DO NOT USE IN THIS AREA

sez.

3
sez.

pag. 69
)
W
(K
w
Bk

124
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 900 R
Q max Min Max Max frame
Type Model (m³/h) (Pa) (RPM) Size
DO NOT USE IN THIS AREA
PRL-TC 900 54000 80 1400 250

sez.

3
)
W
(K
w
Bk

125
PERFORMANCE PRL-TC

Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kW does not
include drive losses.
The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted
outlet. Ratings do not include the effect of duct end corrections.

Air density with 1.2 kg/m³

PRL-TC 1000 R
Q max Min Max Max frame
Type Model (m³/h) (Pa) (RPM) Size
DO NOT USE IN THIS AREA
PRL-TC 1000 72000 150 1400 280

sez.

3
sez.

pag. 69
)
W
(K
w
Bk

126
ASSEMBLY DIMENSIONS PRL-TC

PRL-TC - C SERIES (without drive set)

sez.

Model A B C D E F G H I J K M N O P Q R S t t1 U U1 U2 w x Y Φd LxV

315 518 578 223 404 340 236 280 253 556 480 233 612 283 259 434 274 38 3 8 7 322 344 383 40 28 460 25 13x18

355 578 655 247 453 383 261 355 287 627 548 260 697 327 286 483 300 30 6 8 7 362 386 423 50 33 509 30 13x18

400 651 736 274 507 431.5 290 355 314 654 613 290 724 354 316 537 300 38 4.5 8 7 404 432 466 50 33 563 30 13x18

450 726 827 308 569 486 322 530 348 728 681 318 816 388 344 599 340 45 5 10 8 448 485 515 70 38 625 35 13x18

500 800 918 344 638 538 352 530 384 764 750 350 850 424 376 668 340 50 5 10 8 510 544 570 70 38 694 35 13x18

560 893 1030 383 715 603 390 530 433 855 845 366 945 483 414 745 378 48 8 12 8 570 605 635 90 43 771 40 13x18

630 999 1157 432 801 678.5 434 530 482 904 946 434 994 532 460 831 378 53 7 12 8 635 670 700 90 43 857 40 13x18

710 1121 1303 478 898 765 485 630 528 1005 1058 483 1115 578 512 928 436 63 7 14 9 722 750 778 90 48.5 954 45 17x22

800 1250 1468 533 1007 862 535 710 583 1060 1181 541 1170 633 567 1039 440 69 7 14 9 808 844 875 90 48.5 1063 45 17x22

900 1408 1648 595 1130 971 604 800 655 1191 1319 602 1313 715 613 1160 510 89 7 16 10 896 945 980 100 58.5 1186 55 17x22

1000 1541 1810 663 1267 1066 657 900 713 1259 1462 668 1381 783 694 1297 510 79 9 16 10 996 1044 1080 100 58.5 1323 55 17x22

Dimensions in mm

127
ASSEMBLY DIMENSIONS PRL-TC

PRL-TC C- SERIES LH 180º (Complete assembly)

sez.

3
sez.
SIDE VIEW FRONT VIEW

pag. 69

MODEL A B C D J I X M O U U2

315 518 578 223 404 480 750 558 612 259 322 383
355 578 655 247 453 548 810 618 697 286 362 423
400 651 736 274 507 613 840 691 724 316 404 466
450 726 827 308 569 681 915 766 816 344 448 515
500 800 918 344 638 750 950 840 850 376 510 570
560 893 1030 383 715 845 1035 933 945 414 570 635
630 999 1157 432 801 946 1110 1049 994 460 635 700
710 1121 1303 478 898 1058 1215 1171 1115 512 722 778
800 1250 1468 533 1007 1181 1240 1375 1170 567 808 875
900 1408 1648 595 1130 1319 1380 1533 1313 613 896 980
1000 1541 1810 663 1267 1462 1440 1666 1381 694 996 1080

FRAME SIZE

MODEL DIM 80 90 100 112 132 160 180 200 225 250

L 825 930
315
CD 520 570

L 860 980
355
CD 535 595

L 940 1060 1130


400
CD 595 652 675
L 1005 1125 1200
450
CD 645 700 730
L 1100 1190 1250
500
CD 725 750 755
L 1200 1285 1400
560
CD 795 815 875
L 1300 1390 1560
630
CD 870 895 1000
L 1410 1505 1670 1805
710
CD 960 985 1090 1140
L 1530 1635 1770 1885
800
CD 1060 1090 1160 1190
L 1670 1770 1920 2050
900
CD 1170 1200 1280 1320

L 1810 1950 2100 2250


1000
CD 1270 1330 1415 1470

128
INLET & OUTLET DIMENSIONS PRL-TC

Type 315 355 400 450 500 560 630 710 800 900 1000

A 322 362 404 448 510 570 635 722 808 896 996
B 344 386 432 485 544 605 670 750 844 945 1044
sez.

3
C 383 423 466 515 570 635 700 778 875 980 1080
Nxd 6x7 8x9 8x9 8x9 8x11 8x11 10x13 10x13 12x13 12x13 12x13

Type 315 355 400 450 500 560 630 710 800 900 1000

A 404 453 507 569 638 715 801 898 1007 1130 1267

B 223 247 274 308 344 383 432 478 533 595 663

C 460 509 563 625 684 771 857 954 1063 1186 1323

D 279 303 330 364 400 439 488 534 589 651 719

E - - 200 200 250 250 300 400 500 600 700


F - - - - - - - 200 250 300 350

OPERATION LIMITS

CHARACTERISTICS Unit 315 355 400 450 500 560 630 710 800 900 1000

Maximum Absorbed Power Kw 4 6 7 7 15 18 20 22 25 30 45

Maximum Fan Speed rpm 4000 3800 3200 2800 2800 2600 2200 2000 1600 1400 1400

Temperature Range / min-20ºC MaxºC 180 180 180 180 180 180 180 180 180 180 180

Fan Weight
(does not include motor, base frame and drive Kg 37 50 55 72 89 138 161 215 252 360 445
setup)

129
4
part

IN LINE CENTRIFUGAL FANS

TMF Pg. 133


TMF In - Line Centrifugal Fans

Accessories - TMF Pg. 139

sez.

131
TMF
TMF In - Line Centrifugal Fans

GENERAL DESCRIPTION
The TMF is a series of centrifugal in-line fans with the advantage, typical of axial
fans, to convey air along the same axis of the impeller. This feature, the limited
dimensions and the standardized inlet and outlet sizes grant a particular ease
of installation. The low noise level and the good pressure head makes them
ideal for industrial and residential installations in extracting hoods and small
exhausting plants, since they can be installed in any point along the duct or at
the duct ends, either in intake or exhaust. They are suitable to convey clean air
up to a maximum temperature of -10 to 60°C.

CONSTRUCTION
• Casing in steel sheet is protected against atmospheric agents by epoxy paint.
• Single-phase electric ball-bearing motor with non-self resetting thermal cut-
out is particularly suitable for speed regulation.
• Backward curved centrifugal impeller with high efficiency and low noise
level. Statically and dynamically balanced according to ISO 1940.
• Down stream guide vanes for improved efficiency.
• External electric connections enclosed in a terminal box in self extinguishing sez.

4
technopolymer with IP44 protection.
• Performance in accordance with AMCA standard 210 and 300.
• Fans are supplied with fixing brackets and manufactured in galvanized steel
sheet protected against atmospheric agents by epoxy paint and completed
with screws and wall plugs.

ACCESSORIES (UPON REQUEST)


• Speed regulators.
• Back-draught shutters.
• Collars for fixing to the duct.

Maico Gulf certifies that the DYNAIR model TMF


are licensed to bear the AMCA Seal. The ratings
shown are based on tests and procedures per-
formed in accordance with AMCA Publication
211 and AMCA Publication 311 and comply with
the requirements of the AMCA Certified Ratings
Program. Performance certified is for installation
type C – Ducted inlet, Free outlet. Performance
ratings do not include the effects of appurtenanc-
es (accessories).

133
PERFORMANCE TMF

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

Selection - TMF 75
350

300
TMF 75
250 Air Flow Pressure IP/CL Sound Operating Temp

m3/h Pa dB(A) Min/Max (°C)


200 200 300 44/F 41 -30 / 60
Psta (Pa)

150

100 Rated Power Max. Current Nominal Speed Capacitor Power Supply

W A RPM uF

50
52 0.21 2172 1 220-240 V/1 Ph /60Hz

0
sez. 0 50 100 150 200 250

4
Q - Volume Flow (m³/h)

Selection - TMF 75 P

400

350

TMF 75 P
300
Air Flow Pressure IP/CL Sound Operating Temp

250 m3/h Pa dB(A) Min/Max (°C)


170 340 44/F 34 -30 / 60
Psta (Pa)

200

150
Rated Power Max. Current Nominal Speed Capacitor Power Supply
100
W A RPM uF
45 0.18 1845 1 220-240 V/1 Ph /60Hz
50

0
0 50 100 150 200
Q - Volume Flow (m³/h)
Selection - TMF 100

500

400 TMF 100


Air Flow Pressure IP/CL Sound Operating Temp

m3/h Pa dB(A) Min/Max (°C)


300
250 410 44/F 46 -30 / 60
Psta (Pa)

200

Rated Power Max. Current Nominal Speed Capacitor Power Supply

W A RPM uF
100
85 0.35 2729 2.5 220-240 V/1 Ph /60Hz

0
0 50 100 150 200 250 300
Q - Volume Flow (m³/h)

134
PERFORMANCE TMF

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

Selection - TMF 100 P


500

400 TMF 100 P


Air Flow Pressure IP/CL Sound Operating Temp

m3/h Pa dB(A) Min/Max (°C)


300 245 418 44/F 45 -30 / 60
Psta (Pa)

200

Rated Power Max. Current Nominal Speed Capacitor Power Supply

W A RPM uF
100
61 0.30 2509 3 220-240 V/1 Ph /60Hz

0 sez.

4
0 50 100 150 200 250 300
Q - Volume Flow (m³/h)

Selection - TMF 125


350

300
TMF 125
250 Air Flow Pressure IP/CL Sound Operating Temp

m3/h Pa dB(A) Min/Max (°C)


200 330 315 44/F 46 -30 / 60
Psta (Pa)

150

Rated Power Max. Current Nominal Speed Capacitor Power Supply


100
W A RPM uF
86 0.35 2496 2.5 220-240 V/1 Ph /60Hz
50

0
0 50 100 150 200 250 300 350 400
Q - Volume Flow (m³/h)

Selection - TMF 125 P


500

400 TMF 125 P


Air Flow Pressure IP/CL Sound Operating Temp

m3/h Pa dB(A) Min/Max (°C)


300
325 400 44/F 45 -30 / 60
Psta (Pa)

200

Rated Power Max. Current Nominal Speed Capacitor Power Supply

W A RPM uF
100
62 0.31 2318 3 220-240 V/1 Ph /50hz

0
0 50 100 150 200 250 300 350 400
Q - Volume Flow (m³/h)

135
PERFORMANCE TMF

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

Selection - TMF 150 A

700

600
TMF 150 A
Air Flow Pressure IP/CL Sound Operating Temp
500

m3/h Pa dB(A) Min/Max (°C)


710 610 44/F 52 -30 / 60
Psta (Pa)

400

300

Rated Power Max. Current Nominal Speed Capacitor Power Supply


200
W A RPM uF
183 0.74 2541 4 220-240 V/1 Ph /60Hz
100

sez. 0

4
0 100 200 300 400 500 600 700 800
Q - Volume Flow (m³/h)

Selection - TMF 150 P


600

500
TMF 150 P
Air Flow Pressure IP/CL Sound Operating Temp
400
m3/h Pa dB(A) Min/Max (°C)
560 482 44/F 50 -30 / 60
Psta (Pa)

300

200 Rated Power Max. Current Nominal Speed Capacitor Power Supply

W A RPM uF
100 119 0.50 2477 3 220-240 V/1 Ph /60Hz

0
0 100 200 300 400 500 600 700
Q - Volume Flow (m³/h)

Selection - TMF 160


700

600
TMF 160
500 Air Flow Pressure IP/CL Sound Operating Temp

m3/h Pa dB(A) Min/Max (°C)


400 760 582 44/F 48 -30 / 60
Psta (Pa)

300

Rated Power Max. Current Nominal Speed Capacitor Power Supply


200
W A RPM uF
150 0.60 2345 4 220-240 V/ 1 Ph / 60Hz
100

0
0 100 200 300 400 500 600 700 800 900
Q - Volume Flow (m³/h)

136
PERFORMANCE TMF

Lp: sound pressure level measured at 3m in accordance with AMCA standard 300
Tested in accordance with AMCA standard 210 at air temperature 15°C - Barometric pressure 760 mm Hg - Air specific weight 1.22 Kg/m³

Selection - TMF 200

800

700
TMF 200
600
Air Flow Pressure IP/CL Sound Operating Temp

m3/h Pa dB(A) Min/Max (°C)


500
740 1040 44/F 52 -30 / 60
Psta (Pa)

400

300
Rated Power Max. Current Nominal Speed Capacitor Power Supply

200 W A RPM uF
252 1.01 2763 5 220-240 V/1 Ph /60Hz
100

0 sez.

4
0 200 400 600 800 1000 1200
Q - Volume Flow (m³/h)

Selection - TMF 250


800

700

TMF 250
600
Air Flow Pressure IP/CL Sound Operating Temp

m3/h Pa dB(A) Min/Max (°C)


500
1125 710 44/F 51 -30 / 60
Psta (Pa)

400

300
Rated Power Max. Current Nominal Speed Capacitor Power Supply

200 W A RPM uF
251 0.99 2616 5 220-240 V/1 Ph /60Hz
100

0
0 200 400 600 800 1000 1200 1400
Q - Volume Flow (m³/h)

Selection - TMF 315


900

800

TMF 315
700
Air Flow Pressure IP/CL Sound Operating Temp
600
m3/h Pa dB(A) Min/Max (°C)
840 1550 44/F 65 -30 / 60
500
Psta (Pa)

400

300
Rated Power Max. Current Nominal Speed Capacitor Power Supply

200 W A RPM uF
304 1.22 2665 7 220-240 V/1 Ph /60Hz
100

0
0 200 400 600 800 1000 1200 1400 1600 1800
Q - Volume Flow (m³/h)

137
DIMENSIONS TMF

sez.

Model A B C D E F G H I Kg

TMF 75 286 Ø98 170 Ø243 196 22 22 275 2xØ13 3.00


TMF 75 P 286 Ø98 170 Ø243 196 22 22 275 2xØ13 3.00
TMF 100 286 Ø98 170 Ø243 196 22 22 275 2xØ13 3.00
TMF 100 P 286 Ø98 170 Ø243 196 22 22 275 2xØ13 3.00
TMF 125 286 Ø125 170 Ø243 196 30 25 275 2xØ13 3.00
TMF 125 P 286 Ø125 170 Ø243 196 30 25 275 2xØ13 3.00
TMF 150 A 377 Ø147 170 Ø333 217 22 25 365 2xØ13 4.50
TMF 150 P 377 Ø147 170 Ø333 217 22 25 365 2xØ13 4.50
TMF 160 377 Ø160 170 Ø333 217 25 25 365 2xØ13 5.50
TMF 200 377 Ø198 170 Ø333 216 25 25 365 2xØ13 5.70
TMF 250 377 Ø247 170 Ø333 216 36 25 365 2xØ13 6.00
TMF 315 445 Ø315 170 Ø402 255 40 32 434 2xØ13 7.00

Dimensions in mm

138
ACCESSORIES TMF

SHUTTER

Back draught throttle shutter in galvanized steel sheet with gasket on the closing of the fins for
greater sealing and less noise transmission.

Type
TMF 75
TMF 75 P
TMF 100
TMF 100 P
TMF 125
TMF 125 P
TMF 150 A
TMF 150 P
TMF 160
TMF 200
TMF 250
TMF 315 sez.

4
DUCT CLAMPS

Duct clamp manufactured in galvanized steel sheet, inside lined with expanded polyurethane.
It is necessary to connect the fan to the duct.

Type
TMF 75
TMF 75 P
TMF 100
TMF 100 P
TMF 125
TMF 125 P
TMF 150 A
TMF 150 P
TMF 160
TMF 200
TMF 250
TMF 315

SPEED REGULATOR

Manual voltage converter with continuous regulation by potentiometer.

Type
TMF 75
TMF 75 P
TMF 100
TMF 100 P
TMF 125
TMF 125 P
TMF 150 A
TMF 150 P
500W TMF 160
TMF 200
TMF 250
TMF 315
R16/R18

139
5
part

BOX TYPE DIRECT DRIVEN


CENTRIFUGAL FANS

BOX-D Pg. 143


Direct Drive Double Inlet Box Fans

TW-D Pg. 151


Direct Drive Double Inlet Fans (Duty & Stand-by)

sez.

141
BOX-D
Direct Drive Double Inlet Box Fans

GENERAL DESCRIPTION
The fan of the BOX-D series are particularly designed for air extraction, supply or filtration.
Their main characteristic is the low noise level which makes them ideal for urban environ-
ments (apartments, houses, restaurants, gymnasiums, offices) and industrial sites where
radiated noise is a problem. The low noise level is due to that is plenum, lined with acoustic
material that allows a remarkable reduction of noise level inevitably generated by the fan.
The blower consists of a double inlet forward curve centrifugal fan with built-in motor.

CONSTRUCTION
• Profile-less cabinet is manufactured in PPGL sheet with removable access panel to allow
easy access to the fan and motor.
• The blower is fitted using suitable support feet and is completely isolated from the ca
sing by anti-vibration mounts and gaskets.
• Acoustic lining in self-extinguishing techno-polymer.
• DIDW forward curved with direct drive built-in asynchronous motor, sin
gle-phase or three-phase, particularly suitable for speed regulation (using the suitable
speed regulators shown in this catalogue).
• Flanged inlet and outlet for ease of duct work.

BEYOND STANDARD PRODUCT


• Different discharge orientation.
• Electronic and self-transformer speed regulators.
• Pre-filtered section.
• Customised cabinet size.
• Construction with the Aluminum extruded profile.
• Versions with double skin panels (20 mm thick) only in AL extruded profile.
• Blowers with EC motors are available on request. The performance of these blowers are
not certified by AMCA.

Maico Gulf LLC certifies that the DYNAIR


Model “Box-D 3/4 and 3/8” shown herein
are licensed to bear the AMCA Seal. The
ratings shown are based on tests and
procedures performed in accordance with
AMCA Publication 211 and comply with
the requirements of the AMCA Certified
Ratings Program.

Maico Gulf LLC certifies that the DYNAIR


Model “Box-D 7/7 to 12/12” shown here
in are licensed to bear the AMCA Seal.
The ratings shown are based on tests
and procedures performed in accordance
with AMCA Publication 211 and AMCA
Publication 311 and comply with the
requirements of the AMCA Certified
Ratings Program.

143
DIMENSIONS BOX-D

DISCHARGE ANGLES

NOTE: Standard discharge angles SX-A1

sez.

Wt,Kg(with PPGL Wt,Kg(with AL


TYPE A B C D E F G H I cabinet) cabinet)
BOX D 3/4 300 300 350 48 108 50 121 160 210 10 6
BOX D 3/8 300 300 500 71 214 50 143 133 333 12 7
BOX D 7/7 420 420 420 208 230 65 90 270 270 18 12
BOX D 9/7 500 500 500 262 232 70 130 300 300 28 19
BOX D 9/9 500 500 500 262 298 70 95 300 300 29 20
BOX D 10/8 600 550 600 289 265 75 160 350 400 36 26
BOX D 10/10 600 550 600 289 331 75 127.5 350 400 38 27
BOX D 12/9 640 640 750 341 309 80 215 440 550 51 37
BOX D 12/12 640 640 750 341 395 80 170 440 550 53 39
Dimensions in mm

144
PERFORMANCE BOX-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Sound performance of Box-D 3/4, 3/8 are not licensed by AMCA

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - BOX-D 3-4 B4M


250

Box-D 3/4 B4M


200
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
Psta (Pa)

150 180 28 36 4 20/F 0.15 230/1/60 1514

100

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
Reg (free
50 Field) 63 125 250 500 1K 2K 4K 8K

RVN-RVS 28 59 55 51 47 40 37 35 32
Sound performance not licensed by AMCA
0
0 50 100 150 200
Q - Volume Flow (m³/h)

Selection - BOX-D 3-8 B4M


sez.

5
500
Box-D 3/8 B4M
Max Max
Nominal
Q Input
400 Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
630 190 212 4 44/F 0.88 230/1/60 1359
300
Psta (Pa)

200 Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
Reg (free
Field) 63 125 250 500 1K 2K 4K 8K

100 RVN-RVS 34 65 61 57 53 46 43 41 38

Sound performance not licensed by AMCA

0
0 100 200 300 400 500 600 700
Q - Volume Flow (m³/h)

Selection - BOX-D 7-7 A6M

250
Box-D 7/7 A6M
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
200 (Cmh) Power
(W) (W)
1436 62 251 6 32/F 1.10 230/1/60 892

150
Psta (Pa)

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


100 at 3m
Reg (free
Field) 63 125 250 500 1K 2K 4K 8K

RV/1-RVM/2 52 87 85 74 65 58 49 47 43
50

0
0 200 400 600 800 1000 1200 1400 1600
Q - Volume Flow (m³/h)

145
PERFORMANCE BOX-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - BOX-D 7-7 B4M

600

Box-D 7/7B4M
500
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W)
400
(W)
Psta (Pa)

1508 147 420 4 32/F 1.70 230/1/60 967

300

200 Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
Reg (free
Field) 63 125 250 500 1K 2K 4K 8K
100
RV/1-RVM 53 84 86 77 66 59 52 49 45

0
0 200 400 600 800 1000 1200 1400 1600 1800
Q - Volume Flow (m³/h)

Selection - BOX-D 9-7 A6M


sez. 300

5 250
Box-D 9/7 A6M
Max Nominal Max
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
200 1857 147 400 6 20/F 2.00 230/1/60 849
Psta (Pa)

150

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


100 at 3m
Reg (free
Field) 63 125 250 500 1K 2K 4K 8K

50 RV/2-RVM2 48 85 74 74 63 57 52 47 39

0
0 500 1000 1500 2000 2500
Q - Volume Flow (m³/h)

Selection - BOX-D 9-7 B4M


700

Box-D 9/7 B4M


600
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
500 (W) (W)
2606 370 1145 4 20/F 5.00 230/1/60 1170
400
Psta (Pa)

300

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
200 Reg (free
Field) 63 125 250 500 1K 2K 4K 8K

100 RV/1-RVM/3 56 93 84 81 71 68 62 60 54

0
0 500 1000 1500 2000 2500 3000
Q - Volume Flow (m³/h)

146
PERFORMANCE BOX-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - BOX-D 9-9 A6M

350

300
Box-D 9/9 A6M
250 Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
Psta (Pa)

(W)
200 (W)
2746 245 526 6 20/F 2.60 230/1/60 991

150

100
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
Reg (free
50 Field) 63 125 250 500 1K 2K 4K 8K

RV/2-RVM2 51 87 81 75 67 62 55 53 45
0
0 500 1000 1500 2000 2500 3000 3500
Q - Volume Flow (m³/h)

Selection - BOX-D 9-9 B4M


sez.

5
700

600
Box-D 9/9 B4M
Max Max
500 Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
400
2912 370 1170 4 20/F 4.60 230/1/60 1100
Psta (Pa)

300

200
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
Reg (free
100 Field) 63 125 250 500 1K 2K 4K 8K

RV/1-RVM3 55 90 86 80 70 66 59 57 51
0
0 500 1000 1500 2000 2500 3000 3500
Q - Volume Flow (m³/h)

Selection - BOX-D 10-8 A6M


500

Box-D 10/8 A6M


400
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
300
2624 245 641 6 20/F 2.60 230/1/60 724
Psta (Pa)

200

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
Reg
100 (free
Field) 63 125 250 500 1K 2K 4K 8K

RV/2-RVM2 46 82 76 71 61 56 54 50 43

0
0 500 1000 1500 2000 2500 3000
Q - Volume Flow (m³/h)

147
PERFORMANCE BOX-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - BOX-D 10-8 B4M


900

800

700 Box-D 10/8 B4M


Max Max
600 Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
Psta (Pa)

(Cmh) Power
(W)
500 (W)
3550 550 1400 4 20/F 6.00 230/1/60 1017
400

300

200 Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
Reg (free
100 Field) 63 125 250 500 1K 2K 4K 8K

0 RV/1-RVM3 57 92 87 83 70 66 64 61 56
0 1000 2000 3000 4000
Q - Volume Flow (m³/h)

Selection - BOX-D 12-9 A6M


sez. 700 Selection - BOX-D 10-10 A6M

5 500
600

Box-D 10/10 A6M


500
400
Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
400 (Cmh) Power
(W) (W)
(Pa)
Psta (Pa)

300
2041 245 627 6 20/F 2.65 230/1/60 694
Psta

300

200
200

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


100 at 3m
Reg
100 (free
Field) 63 125 250 500 1K 2K 4K 8K
0
0 1000 2000 3000 4000 5000 6000 RV/2-RVM2 49 84 79 74 63 58 57 55 46
0 Q - Volume Flow (m³/h)
0 500 1000 1500 2000 2500
Q - Volume Flow (m³/h)
Selection - BOX-D 12-9 A6T
700 Selection - BOX-D 10-10 B4M
1000
600
900 Box-D 10/10 B4M
800
500 Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
700 (W) (W)
400
600 4093 550 1484 4 20/F 6.00 230/1/60 975
(Pa)(Pa)
PstaPsta

300
500

400
200
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
300 at 3m
Reg (free
100 63 125 250 500 1K 2K 4K 8K
200
Field)

RV/1-RVM/3 56 89 86 82 70 65 63 62 56
100
0
0 1000 2000 3000 4000 5000 6000 7000

0 Q - Volume Flow (m³/h)


0 1000 2000 3000 4000 5000
Q - Volume Flow (m³/h)

Selection - BOX-D 12-12 A6M


148
700
700

PERFORMANCE 600 BOX-D

Psta (Pa)
500

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.
400
Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A)
300 levels are not licensed by AMCA International.

200 (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Speed
Performance certified is for installation type D - Ducted inlet, ducted outlet.
100

0
0 1000 2000 3000 4000
Q - Volume Flow (m³/h)

Selection- BOX-D
Selection - BOX-D12-9
10-10 A6M
A6M
700
500

600 Box-D 12/9 A6M


Max Max
400 Nominal
Q Input
500 Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
(Pa)(Pa)

400
300
4734 590 1541 6 20/F 6.80 230/1/60 678
PstaPsta

300

200
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
200 at 3m
Reg (free
Field) 63 125 250 500 1K 2K 4K 8K
100
100
RV/2-RVM3 56 86 86 82 69 66 65 61 53

0
0 0 1000 2000 3000 4000 5000 6000
0 500 1000 1500 2000 2500
Q - Volume Flow (m³/h)
Q - Volume Flow (m³/h)
sez.

5
Selection - BOX-D 12-9 A6T
Selection - BOX-D 10-10 B4M
700
1000

900
600 Box-D 12/9 A6T
800 Max Max
Nominal
500 Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
700 (W) (W)
400
600 6321 1100 2146 6 20/F 4.30 380/3/60 940
Psta (Pa)

500
300

400

200 Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


300
at 3m
Reg (free
200 Field) 63 125 250 500 1K 2K 4K 8K
100

100 RVT/2 61 95 91 85 77 72 72 68 63
0
0 0 1000 2000 3000 4000 5000 6000 7000
0 1000 Q - Volume
2000 Flow3000
(m³/h) 4000 5000
Q - Volume Flow (m³/h)

Selection - BOX-D 12-12 A6M


700
Box-D 12/12 A6M
600 Max Max
Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W)
500 (W)
5090 590 1591 6 20/F 6.90 230/1/60 735
400
Psta (Pa)

300
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
Reg
200 (free
Field) 63 125 250 500 1K 2K 4K 8K

RV/2-RVM3 61 89 89 88 70 66 65 60 52
100

0
0 1000 2000 3000 4000 5000 6000
Q - Volume Flow (m³/h)

149
PERFORMANCE BOX-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - BOX-D 12-12 A6T


700

600
Box-D 12/12 A6T
Max Max
500 Nominal
Q Input
Power P IP/CL In (A) V/Ph/F RPM
(Cmh) Power
(W) (W)
Psta (Pa)

400
7016 1100 2203 6 20/F 4.70 380/3/60 964

300

200 Lp dB (A) Octave Band Frequency at max. airflow Hz (Lw, dB)


Reg at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K
100
RVT/2 62 96 94 85 77 72 72 67 61
0
0 1000 2000 3000 4000 5000 6000 7000 8000
Q - Volume Flow (m³/h)
sez.

150
TW-D
Twin- Direct Drive Fan (Duty and Stand-by)

GENERAL DESCRIPTION
The fan of the TWD series are particularly designed for installation where it is mandatory to
guarantee an uninterrupted air exhaust even in the case of failure.

The units are provided with duty and stand-by fan which automatically starts in case of break-
down.

Duty and stand-by fans can be manually exchanged with a dedicated control logic that is avail-
able in different versions (Auto Changeover panel).

TW-D: Suitable for indoor and outdoor application.

CONSTRUCTION
• Profile-less cabinet is manufactured in PPGL sheet with removable access panel to allow
easy access to fan and motor.
• The blower is fitted using suitable support feet and is completely isolated from the casing
by anti-vibration mounts and gaskets.
• Acoustic lining in self-extinguishing techno-polymer.
• DIDW forward curved with direct drive built-in asynchronous motor, single-phase or
three-phase, particularly suitable for speed regulation (using the suitable speed regulators
shown in this catalogue).
• Flanged inlet and outlet for easy ease of duct work
sez.
BEYOND THE STANDARD PRODUCT
• Version with double skin panels (20 mm thick).
• Different discharge orientation. 5
• TW-D construction available in AL extruded profile on request with PPGI/AL sheet.
• Blowers with EC motors (Performance are not certified by AMCA).

Maico Gulf LLC certifies that DYNAIR


Model “TWD 3/4 shown herein is licensed to
bear the AMCA Seal. The ratings shown are
based on tests and procedures performed in
accordance with AMCA Publication 211 and
comply with the requirements of the AMCA
Certified Ratings Program.

Maico Gulf LLC certifies that DYNAIR


Model “TWD 3/8 to 12/12” shown here in are
license to bear the AMCA Seal. The ratings shown
are based on tests and procedures performed in
accordance with AMCA Publication 211 and AMCA
Publication 311 and comply with the requirements
of the AMCA Certified Ratings Program.

151
DIMENSIONS TW-D

I G H
F
"D" Inlet
TOP ACCESS

"A" OUTLET

"A" Outlet
"C" Inlet
K
E

J
"B" Outlet

sez. Wt, Kg Wt, Kg

5
TYPE A B C D E F G H I J K (with PPGL) (with AL cabinet)
TWD 3/4 B4M 125 420 165 300 300 700 300 40 40 154 75 15 10
TWD 3/8 B4M 200 750 200 300 350 900 350 40 40 230 106 22 18
TWD 7/7 B4M 350 800 350 400 550 1000 550 40 40 230 210 34 28
TWD 7/7 A6M 350 800 350 400 550 1000 550 40 40 230 210 34 27
TWD 9/7 B4M 350 800 350 400 600 1000 600 40 40 230 264 48 40
TWD 9/7 A6M 350 800 350 400 600 1000 600 40 40 230 264 44 35
TWD 9/9 B4M 400 1000 400 500 600 1200 600 40 40 300 264 54 45
TWD 9/9 A6M 400 1000 400 500 600 1200 600 40 40 300 264 52 43
TWD 10/8 B4M 400 1000 400 600 600 1200 600 40 40 265 294 64 51
TWD 10/8 A6M 400 1000 400 600 600 1200 600 40 40 265 294 59 45
TWD 10/10 B4M 400 1000 400 600 600 1200 600 40 40 330 294 66 53
TWD 10/10 A6M 400 1000 400 600 600 1200 600 40 40 330 294 61 47
TWD 12//9 A6M 400 1200 400 600 750 1400 750 40 40 310 343 94 72
TWD 12/9 A6T 400 1200 400 600 750 1400 750 40 40 310 343 97 75
TWD 12/12 A6M 400 1200 400 600 750 1500 750 40 40 400 343 100 77
TWD 12/12 A6T 400 1200 400 600 750 1500 750 40 40 400 343 104 80
Dimensions in mm

152
PERFORMANCE TW-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels. referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - TWD 3-4 B4M


250

TWD 3/4 B4M


200
Power
Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
(P inp) (P out)
150 187 33.9 33.2 0.14 230/1/60 20/F 1 AC04 NA
Psta (pa)

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


100 at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K

45 86 78 62 61 50 47 45 41
50
Sound performance of 3/4 Lp dB (A) is not licensed by AMCA

0
0 50 100 150 200 250
Q - Volume Flow (m³/h)

Selection - TWD 3-8 B4M


500 sez.
TWD 3/8 B4M
Power
5
400 Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
(P inp) (P out)
300 579 204 210 0.85 230/1/60 44/B 3 AC04 NA
Psta (pa)

200 Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K

100 46 87 79 63 62 51 48 46 42

0
0 100 200 300 400 500 600 700
Q - Volume Flow (m³/h)

Selection - TWD 7-7 B4M


500
TWD 7/7 B4M
Power
400 Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
(P inp) (P out)

300 1386 427 155 1.84 230/1/60 32/F 6.3 AC04 NA


Psta (pa)

200
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K
100
47 83 74 74 57 53 52 47 45

0
0 200 400 600 800 1000 1200 1400 1600
Q - Volume Flow (m³/h)

153
ACCESSORIES
PERFORMANCE TW-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - TWD 7-7 A6M

250

TWD 7/7 A6M


Power
200 Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
(P inp) (P out)
150 1404 256 72 1.1 230/1/60 32/F 4 AC04 NA
Psta (pa)

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


100 at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K

48 82 75 75 59 54 53 49 46
50

0
0 200 400 600 800 1000 1200 1400 1600
Q - Volume Flow (m³/h)

Selection - TWD 9-7 B4M


sez. 700

5 600
TWD 9/7 B4M
Power
Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
500 (amp) Module
(P inp) (P out)

400 2370 1117 429 5.01 230/1/60 20/F 10 AC04 NA


Psta (pa)

300
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
(free
200 Field) 63 125 250 500 1K 2K 4K 8K

55 96 86 74 66 64 61 59 53
100

0
0 500 1000 1500 2000 2500 3000

Q - Volume Flow (m³/h)

Selection - TWD 9-7 A6M


350
TWD 9/7 A6M
300
Power
Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
250
(P inp) (P out)

1667 417 171 1.89 230/1/60 20/F 5 AC04 NA


200
Psta (pa)

150
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
100 (free
Field) 63 125 250 500 1K 2K 4K 8K

48 87 79 70 61 56 54 50 43
50

0
0 500 1000 1500 2000
Q - Volume Flow (m³/h)

154
PERFORMANCE TW-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - TWD 9-9 B4M


800

TWD 9/9 B4M


700
Power
Q (Watts) A Power
600 (Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
(P inp) (P out)
500
2599 1186 380 5.35 230/1/60 20/F 10 AC04 NA
Psta (pa)

400

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


300 at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K
200
48 83 79 69 61 58 58 57 48

100

0
0 500 1000 1500 2000 2500 3000
Q - Volume Flow (m³/h)

Selection - TWD 9-9 A6M

350
sez.

300
TWD 9/9 A6M 5
Power
Q (Watts) A Power
250 (Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
(P inp) (P out)
Psta (pa)

200 2498 646 291 2.9 230/1/60 20/F 8 AC04 NA

150
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
100 (free
Field) 63 125 250 500 1K 2K 4K 8K

44 82 71 65 59 56 56 54 45
50

0
0 500 1000 1500 2000 2500 3000
Q - Volume Flow (m³/h)

Selection - TWD 10-8 B4M

900

800 TWD 10/8 B4M


700 Power
Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
600
(P inp) (P out)
Psta (pa)

500 3463 1379 564 6.0 230/1/60 20/F 16 AC04 NA

400

300 Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
(free
200 Field) 63 125 250 500 1K 2K 4K 8K

100 52 86 75 71 66 66 64 64 57

0
0 500 1000 1500 2000 2500 3000 3500 4000
Q - Volume Flow (m³/h)

155
PERFORMANCE TW-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - TWD 10-8 A6M

500
TWD 10/8 A6M
Power
400 Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
(P inp) (P out)

300 2514 625 238 2.9 230/1/60 20/F 8 AC04 NA


Psta (pa)

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


200 at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K

43 82 70 61 58 57 56 53 44
100

0
0 500 1000 1500 2000 2500 3000
Q - Volume Flow (m³/h)
Selection - TWD 10-10 B4M

sez.

5
1000

900
TWD 10/10 B4M
Power
800 Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
700
(P inp) (P out)

600 3814 1500 549 6.6 230/1/60 20/F 16 AC04 NA


Psta (pa)

500

400 Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
(free
300 Field) 63 125 250 500 1K 2K 4K 8K

200 52 85 78 76 69 63 62 61 53

100

0
0 1000 2000 3000 4000 5000
Q - Volume Flow (m³/h)

Selection - TWD 10-10 A6M

500

TWD 10/10 A6M


400 Power
Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
(P inp) (P out)
300 2610 656 232 3.0 230/1/60 20/F 8 AC04 NA
Psta (pa)

200
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K
100
44 82 74 66 59 54 54 51 42

0
0 500 1000 1500 2000 2500 3000
Q - Volume Flow (m³/h)

156
PERFORMANCE TW-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - TWD 12-9 A6M


700

TWD 12/9 A6M


600
Power
Q (Watts) A Power
500 (Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
(P inp) (P out)
400 4341 1564 600 7.4 230/1/60 20/F 16 AC04 NA
Psta (pa)

300
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
(free
200 Field) 63 125 250 500 1K 2K 4K 8K

54 89 76 80 68 64 63 62 54
100

0
0 1000 2000 3000 4000 5000
Q - Volume Flow (m³/h)

Selection - TWD 12-9 A6T


700
sez.

600 TWD 12/9 A6T 5


Power
500 Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
400
(P inp) (P out)

6242 2477 1465 4.5 380/3/60 20/F NA AC02 P.M


Psta (pa)

300

Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


200 at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K
100
59 99 83 79 75 72 70 70 66

0
0 1000 2000 3000 4000 5000 6000 7000
Q - Volume Flow (m³/h)

Selection - TWD 12-12 A6M


700

600
TWD 12/12 A6M
500 Power
Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
(amp) Module
400
(P inp) (P out)
Psta (pa)

4341 1621 577 7.7 230/1/60 20/F 16 AC04 NA


300

200 Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)


at 3m
(free
Field) 63 125 250 500 1K 2K 4K 8K
100

56 87 76 84 66 61 62 58 50
0
0 1000 2000 3000 4000 5000
Q - Volume Flow (m³/h)

157
PERFORMANCE TW-D

Values shown are for inlet Lwi sound power levels for Installation Type D: ducted inlet, ducted outlet. Ratings include the effects of duct end correction.

Sound power levels ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301.

Lp-dB(A) levels are not licensed by AMCA International.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance certified is for installation type D - Ducted inlet, ducted outlet.

Selection - TWD 12-12 A6T

700

TWD 12/12 A6T


600
Power
Q (Watts) A Power
(Cmh) V/Ph/F IP/CL uF Reg
500
(amp) Module
(P inp) (P out)

6840 2620 1433 3.7 380/3/60 20/F NA AC02 P.M


400
Psta (pa)

300
Lp dB (A) Octave Band Frequency at max.airflow Hz (Lw, dB)
at 3m
(free
200 Field) 63 125 250 500 1K 2K 4K 8K

62 96 84 80 84 72 70 69 64
100

0
0 1000 2000 3000 4000 5000 6000 7000 8000
Q - Volume Flow (m³/h)

sez.

158
FAN CONTROLLER MODEL AC-02/04

DESCRIPTION
Twin fan controller model AC-02/04 is designed using microcontroller technology and it is
capable operating two fans as per the programmed time sequence. This controller has an
in-built diagnostic and controlling function.

ADVANCED FEATURES
• User-friendly programming steps.
• Controller can be configured to either Auto or Manual mode.
• Auto mode is further divided into air sense mode, current sense mode or air-current
sense mode.
• Manual mode is also divided into air sense, current sense mode or air-current sense
mode.
• Programmable cycle timer from 1 to 12 hours.
• Seven segment display and LED indicators for better programming and fault monitoring
features to enhance the user experience.
• Building Management system (BMS) status indication through volt free relay contacts.
• Designed to operate directly on 220V/50Hz/60Hz at 2 amps or 12 amps, single phase
motor.
• Option with 220V control voltage to connect three-Phase motor through appropriate
programming along with power module.
• Programmable over current protection features.
• In-built fusible link as standard features.
• Actual size: 175 X 175 X 75 mm.
• Weight: 820 gm.

sez.

159
6
part

CEILING EXHAUST FAN

DCE Pg.163
Ceiling Exhaust Fan

sez.

161
DCE
Ceiling Exhaust Fan

DESCRIPTION
The DCE series fan is for an indoor ceiling mounting for clear air and specially for quiet
noise requirements.

Plug and play option with special grill and effective aerodynamic inlet design.
Complete construction in metal for robust & higher MTBF life.

CONSTRUCTION FEATURES
• Cabinet is manufactured from PPGL sheet with acoustic lining and self-extinguishing techno
-polymer for maintaining low operating sound.
• High performance centrifugal forward curve direct drive fan with single phase capacitor run
motor.
• It is thermally overload protected and continues duty lifetime operated with quiet operation
ball bearing is used it is compatible with electronic speed regulator.
• Automatic backdraft damper for preventing back-flow.
• Air intake is through polymeric grille with 85% free area egg crate design.
• Mounting flanges on either side for easy installation.

APPLICATION
• Residential / commercial bathrooms.
• Boardrooms.
• Pantry.
• Any low noise application with free inlet.

sez.

Maico Gulf LLC certifies that DYNAIR


Mode “DCE 50 A to DCE 200B” shown
herein are licensed to bear the AMCA Seal.
The ratings shown are based on tests
and procedures performed in accordance
with AMCA Publication 211 and AMCA
Publication 311 and comply with the
requirements of the AMCA certified Rating
Program.

163
DIMENSIONS DCE

DCE
WEIGHT
EGG GRATE
Model A B C D D1 E E1 H (PPGL cabinet)
GRILL F X G kg
DCE 50 A 200 200 180 42 82 56 86 30 220 x 220 6
sez.

6 DCE 100 A

DCE 100 B
200

200
200

200
200

230
46

50
77

92
51

76
82

107
30

30
220 x 220

220 x 220
6

DCE 200 A 230 230 250 50 92 76 107 30 250 x 250 6

DCE 200 B 250 250 300 92 134 94 125 30 270 x 270 6

Dimensions in mm

PERFORMANCE

Selection - DCE 50 A
200

DCE 50 A
Power
150
(w) (A)
(CMH) V/Ph/Hz IP/CL µF
Amp
Input Output
Psta (Pa)

100 105 31.1 30 0.1 230/1/60 44/B 1

Octave Band Frequency at Max. Airflow Hz (Lw, dB)


Lp
50 dB(A)
at 3 m
(free Field) 63 125 250 500 1K 2K 4K 8K

38 56 65 62 55 52 45 46 44
0
0 20 40 60 80 100 120
Q - Volume Flow (m³/h)
Selection - DCE 100 A
250

164200
(Pa)
Psta (Pa)
PERFORMANCE 100 DCE

Psta Speed (RPM) Shown is Nominal. Performance is based on actual speed of test. Performance rating include the effect of the inlet Grille and Backdraft damper.
50
Performance Certified is for Installed Type B: free inlet and ducted outlet.
(Voltage Can be Consider ± 10)
Values shown are for inlet Lwi sound levels for Installed Type B: free inlet, Ducted Outlet, rating include the effect of duct end correction.
The sound power levels rating shown are in Decibels, Reference to 10 ¹² Watts, Calculated AS per AMCA 301.
LP-dB(A) level are not licensed by AMCA International.
0
0 20 40 60 80 100 120
Q - Volume Flow (m³/h)
Selection - DCE 100 A
250
DCE 100 A
Power
200
(w) (A)
(CMH) V/Ph/Hz IP/CL µF
Amp
Input Output
(Pa)
Psta (Pa)

150
112.2 36.5 37 0.2 230/1/60 44/B 1.5
Psta

100

Octave Band Frequency at Max. Airflow Hz (Lw, dB)


Lp
50 dB(A)
at 3 m
(free Field) 63 125 250 500 1K 2K 4K 8K

0 42 57 64 58 51 61 50 46 42
0 20 40 60 80 100 120 140
Q - Volume Flow (m³/h)

Selection - DCE 100 B


350
DCE 100 B
300
Power
(w) (A)
250 (CMH) V/Ph/Hz IP/CL µF
Amp
Input Output
(Pa)
Psta (Pa)

200
175.1 35.5 35 0.2 230/1/60 44/B 1
Psta

150

100 Lp Octave Band Frequency at Max. Airflow Hz (Lw, dB)


dB(A)
at 3 m
50 (free Field) 63 125 250 500 1K 2K 4K 8K
sez.
0
0 50 100 150
Q - Volume Flow (m³/h)
200
37 54 55 55 53 56 44 44 38
6
Selection--DCE
Selection DCE200
200AA
500
500
DCE 200 A
Power
400
400
(w) (A)
(CMH) V/Ph/Hz IP/CL µF
Amp
Input Output
300
300
(Pa)
Psta (Pa)

278.8 101.1 100 0.4 230/1/60 44/B 2


Psta

200
200

Lp Octave Band Frequency at Max. Airflow Hz (Lw, dB)


dB(A)
100
100 at 3 m
(free Field) 63 125 250 500 1K 2K 4K 8K

00 44 61 65 67 62 59 52 52 50
00 50
50 100 150
100 150 200200 250
250 300300 350
350
QQ-- Volume
Volume Flow
Flow (m³/h)
(m³/h)
Selection--DCE
Selection DCE200
200BB
600
600
DCE 200 B
500
500 Power
(w) (A)
(CMH) V/Ph/Hz IP/CL µF
Amp
400
400 Input Output
(Pa)
Psta (Pa)

508.3 196.8 205 0.8 230/1/60 44/B 4


Psta

300
300

200
200
Lp Octave Band Frequency at Max. Airflow Hz (Lw, dB)
dB(A)
at 3 m
100
100 (free Field) 63 125 250 500 1K 2K 4K 8K

00 50 67 73 73 68 63 58 59 56
00 100
100 200
200 300
300 400
400 500
500 600
600
QQ-- Volume
Volume Flow
Flow (m³/h)
(m³/h)

165
7
part

BOX TYPE BELT DRIVEN


CENTRIFUGAL FANS

BOX-T Pg. 169


Belt Driven Double Inlet Box Fans

Accessories - BOX-T Pg. 193

TW-D/T Pg. 194


Belt Driven Twin Fans

sez.

167
BOX-T
Belt Driven Double Inlet Box Fans

GENERAL DESCRIPTION
Belt driven centrifugal cabinet fans with special acoustic lining for improved sound radiation control
from 175 to 6,000 CMH airflow range.

The low noise level is due to their plenum, lined with acoustic material that allows a remarkable reduc-
tion of noise level, inevitably generated by the fan.

Their main characteristic is the low noise level which makes them ideal for urban environments (apart-
ments, houses, bars, restaurants, gymnasiums, offices) and industrial sites where the noise is a prob-
lem.

The low noise level is due to their plenum, lined with acoustic material, that allows a remarkable reduc-
tion of noise level, inevitably generated by the fan.

The blower consists of a double inlet double width forward curved centrifugal fan with built-in motor.

CONSTRUCTION
• Profile less cabinet is manufactured in PPGL sheet with removable access panel to allow easy access
to fan and motor.
• The blower is fitted using suitable support feet and is completely isolated from the casing by anti- vi
bration mounts and gaskets.
• Acoustic lining in self-extinguishing techno-polymer.
• Double inlet blower forward curved with direct drive built-in asynchronous motor, single-phase or
three-phase, particularly suitable for speed regulation (using the suitable speed regulators shown in
this catalogue).
• Flanged inlet and outlet for easy duct work.
• Asynchronous three-phase motors according to international standards IEC 60034, IEC 60072, EMC
2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F. Suitable for S1 service (continuous working
at constant load).

ACCESSORIES
• Weatherproof protection cover.
• Support feet.
• Outlet terminal with guard. sez.

Maico Gulf LLC. certifies


that the DYNAIR model
• Setting shutter.
• Setting shutter with filtering section (standard version with filter in polyester with efficiency 90.1%,
class EU4).
7
BOX-T 7/7 to 630 shown
herein are licensed to bear BEYOND THE STANDARD PRODUCT
the AMCA Seal. The ratings • Version with three-phase double polarity motor (4/6 pole).
shown are based on tests • Asynchronous mono-phase motors according to international standards IEC 600034, IEC 60072,
and procedures performed EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F. Suitable for S1 service (continuous
in accordance with AMCA working at constant load).
Publication 211 and AMCA • Panels in aluminum.
Publication 311 and comply • Double skin panels (available thickness: 25 or 50 mm) any possible in extruded AL profile
with the requirements of • With pre and bag filter.
the AMCA Certified Ratings • Options with backward curved and sizes more than 630 mm.
Program.

DISCHARGE ANGLES BOX-T

INSPECTION
Dx-A1 Dx-A1b Dx-A2 Dx-A3
DX

INSPECTION
Sx-A1 Sx-A1b Sx-A2 Sx-A3
SX

N.B: Standard discharge angles DX-A1

169
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

170
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

171
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

172
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

173
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

174
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

175
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

176
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

177
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

178
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

179
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

180
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

181
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

182
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

183
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

184
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

185
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

186
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

187
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

188
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

189
PERFORMANCE BOX-T

Air performances measured according to EN ISO 5801 / AMCA 210 standard


with air density with 1.2 kg/m³ specific weight.
Power supply 220-240V/1Ph/60Hz or 380-420V/3Ph/60Hz.

Lp: Sound pressure level measured in free field conditions, propagation hemispherical,
measurement category C in accordance with EN ISO 13349, at the point of maximum efficiency, at a distance of 1,5 meters (for comparative purposes only).
Lw: Sound power level obtained in accordance with EN ISO 3746. Tolerance +/- 3 dB(A).

sez.

190
DIMENSIONS BOX-T

All dimensions in mm. 2. Weight with Fan, Std. motor as per below motor frame size & Std. drive set these dimensions are without any accessories 3. Any Non-standard sizes
with different accessories. weight please consult with your local representative. 4. Dynair reserve the right, while leaving the essential characteristics the same ,to modify the data,
photograph and anything else shown in the above without prior warning.

BOX-T 7-7 to 12-12

Max. Motor Frame Approx. Total


Model A B C D E F G H J
Size Weight (Kg)
7-7 550 680 600 470 520 259 228 90 67
9-7 650 750 650 570 570 232 262 112 85
9-9 650 750 650 570 570 298 262 112 87
10-8 700 850 650 620 570 265 289 100 40 112 91
10-10 700 850 650 620 570 331 289 112 96
12-9 750 875 750 670 670 309 341 132 120
BOX-T12-12
15-11 to 18-18 750 875 750 670 670 395 341 132 124

sez.

7
BOX-T 15-15 to 18-18

Max. Motor Frame Approx. Total


Model A B C D E F G H J
Size Weight (Kg)
15-15 900 1050 900 820 820 471 404 132 212
18-13 1100 1150 1100 1020 1020 430 478 100 40 160 277
18-18 1100 1150 1100 1020 1020 557 478 160 302

191
DIMENSIONS BOX-T

All dimensions in mm. 2. Weight with Fan, Std. motor as per below motor frame size & Std. drive set these dimensions are without any accessories 3. Any Non-standard sizes
with different accessories. weight please consult with your local representative. 4. Dynair reserve the right, while leaving the essential characteristics the same ,to modify the data,
photograph and anything else shown in the above without prior warning.

BOX-T 200 to 400

Max. Motor Frame Approx. Total


Model A B C D E F G H I J
Size Weight (Kg)
200 600 750 600 255 255 70 70 500 500 100 80 105
225 650 950 650 290 290 70 70 550 550 100 90 125
250 700 1000 700 325 325 70 70 600 600 100 90 135
280 800 1050 800 360 360 70 70 700 700 100 160 175
315 850 1200 900 405 405 70 70 725 775 100 160 210
355 950 1250 1000 455 455 70 70 825 875 100 180 235
400 1000 1300 1100 510 510 70 70 875 975 100 180 310
With extruded AL profile

BOX-T 450 to 630

sez.

Max. Motor Frame Approx. Total


Model A B C D E F G H I J
Size Weight (Kg)
450 1200 1400 1200 570 570 70 70 1075 1075 100 200 355
500 1200 1400 1200 640 640 70 70 1075 1075 100 200 404
560 1300 1650 1350 715 715 70 70 1175 1225 100 200 477
630 1450 1760 1500 800 800 70 70 1325 1375 100 200 602
With extruded AL profile

192
ACCESSORIES BOX-T

Type A B C D

7/7 382 517 385 495


9/9 447 567 445 535 1 SETTING SHUTTER
10/10 497 567 495 535
2 SETTING SHUTTER WITH FILTERING SECTION sez.

7
12/12 577 617 584 585
15/15 677 817 645 755
18/18 817 1017 775 955
3 FILTERING SECTION
500 987 1117 965 1055
560 1110 1270 1075 1205
630 1230 1420 1205 1355
Dimensions in mm

193
TW-D/ T
Belt Driven Twin Fans

GENERAL DESCRIPTION
The fan of the TW-D/T series are particularly designed for installation where it is manda-
tory to guarantee an uninterrupted air exhaust even in case of failure.

The units are provided with duty and stand-by fan which automatically starts in case of
breakdown.

Duty and stand-by fans can be manually exchanged with a dedicated control logic, avail-
able in different versions (Auto Changeover Panel).

Airflow range – 3,400 to 50,000 CMH.

CONSTRUCTION

CABINET
• The twin units TW – D/T, use a common outlet with a system of gravity shutters that
prevents the air recycling through “stand-by” fan.
• Each fan is supplied with a flow sensor switch, in a case of failure of the duty fan gives
information to the changeover panel and it will automatically alternate the working
cycle of the fans.
• TW-D/T frame is with profile and panels in PPGL sheet.
• Lined with techno-polymer class I.
• Inlet and outlet co-axial suitable for being ducted either in exhaust or supply.
• Double inlet belt drive fan with asynchronous three-phase, class F motor.

MOTOR
• Asynchronous three-phase motors according to international standards IEC 60034,
IEC 60072, IP 55, class F, (continuous working at constant load), suitable to S1 service.

BEYOND THE STANDARD PRODUCT


• Version with double skin panels of 20/50 mm thickness (only possible with extruded
Al Profile construction).
• Different discharge orientation.
sez. • Customized cabinet size.

7 • Weather protection guard (canopy).


• Safety protection guard.

194
DIMENSIONS TW-D/ T

Maximum installed motor Kw can be upto 7.5Kw for the above ranges.
Esp above 500 Pa backward curve can be recomended.
without Profile version is limited to 7/7 to 18/18 and up to 100L motor frame size.

TW-D/T-7/7 to 12/12 & 200 to 315

TW-D/T-15/15 to 18/18 & 355 to 630

sez.

TWD-T WITHOUT PROFILE 7-7 TO 18-18 (Standard)

Outlet Collar Inlet Collar


TYPE W H L w1 h1 w2 h2
TW-D/T 7/7 1000 550 750 800 350 400 350
TW-D/T 9/7 1000 600 800 800 350 400 350
TW-D/T 9/9 1200 600 800 900 350 500 400
TW-D/T 10/8 1200 650 900 1000 400 500 400
TW-D/T 10/10 1200 650 900 1000 400 500 400
TW-D/T 12/9 1400 750 950 1100 400 600 400
TW-D/T 12/12 1500 750 950 1200 400 600 400
TW-D/T 15/15 1800 1000 1100 1500 500 800 500
TW-D/T 18/18 2100 1000 1270 1700 600 1000 600
TW-D/T 200 1000 550 750 800 350 400 350
TW-D/T 225 1200 650 900 800 350 500 400
TW-D/T 250 1200 650 900 1000 400 500 400
TW-D/T 280 1400 750 950 1100 400 600 400
TW-D/T 315 1500 750 950 1200 400 600 400
TW-D/T 355 1800 1000 1100 1500 500 800 500
TW-D/T 400 2100 1000 1270 1700 600 1000 600
TW-D/T 450 2400 1200 1400 1900 750 1200 700
TW-D/T 500 2400 1200 1400 1900 750 1200 700
TW-D/T 560 2600 1300 1650 2200 800 1500 700
TW-D/T 630 3000 1450 1760 2400 900 1800 800
Dimensions in mm

195
8
part

SPEED REGULATORS

TYPE In max (A) Pg. Single Phase Electronic Speed Regulators

R16 0.8 199

R18 2.1 200

R20S 8.6 201

TYPE In max (A) Pg.

ERV-AC-500 - PHE 2.1 202

ERV-AC-500 - HRW 2.1 202

ERV-EC 500 - PHE 2.1 202

ERV-EC 500 - HRW 2.1 202

AC-02/04 12.0 203

sez.

197
R16
Single-phase Speed Regulator 200 W

DESCRIPTION
Manual voltage converter with continuous regulation by potentiometer. Suitable for
single-phase asynchronous adjustable motor.
CONSTRUCTION
• Infinitely variable electronic speed controller by potentiometer.
• New design with cover.
• Suitable for surface mounting.
• Housing in techno-polymer RAL 9016 (white).
• Single-phase 230V – 50/60 Hz.
500W • Max. load 200 Watt.
• Protection IP41.
• Weight 20gm.

500W

DIMENSIONS AND WIRING DIAGRAM R16


Dimensions in mm

R16
35

SPEED REGULATOR

sez.

8
R16 72
35

L L
SPEED
IN REGULATOR
OUT

M Fan Motor
48
50

230 Volt, 50/60 Hz LINE


3.

L L 72
IN OUT

41
Neutral
82

M Fan Motor
48
50

230 Volt, 50/60 Hz LINE


3.

41
Neutral
82

199
R18
Single-phase Speed Regulator 500 W

DESCRIPTION
Manual voltage converter with continuous regulation by potentiometer. Suitable for
single-phase asynchronous adjustable motor.
CONSTRUCTION
• Infinitely variable electronic speed controller by potentiometer.
• New design with cover.
• Suitable for surface mounting.
• Housing in techno-polymer RAL 9016 (white).
• Single-phase 230V – 50/60 Hz.
500W • Max. load 500 Watt.
• Protection IP41.
• Weight 20gm.

500W

DIMENSIONS AND WIRING DIAGRAM R18


Dimensions in mm

R16
35

SPEED REGULATOR

sez.

8 R18
R16 72
35

L L
IN OUT SPEED REGULATOR

M Fan Motor
48
50

230 Volt, 50/60 Hz LINE


3.

L L 72
IN OUT

41
Neutral
82

M Fan Motor
48
50

230 Volt, 50/60 Hz LINE


3.

41
Neutral
82

200
R20S
Single-phase Speed Regulator 2000W

DESCRIPTION
Manual voltage converter with continuous regulation by potentiometer. Suitable for
single-phase asynchronous adjustable motor.

CONSTRUCTION
• Infinitely variable electronic speed controller by potentiometer.
• ON/OFF switch.
• New design with cover.
• Suitable for surface mounting.
• Housing in techno-polymer RAL 9016 (white).
• Single-phase 230V – 50/60 Hz.
• Max. load 2000 Watt.
• Protection IP55.
• Weight 23gm.

DIMENSIONS AND WIRING DIAGRAM R20S


Dimensions in mm

sez.

100 60
R20S
8
SPEED REGULATOR

R20S
100

L L
IN OUT

M Fan Motor

230 Volt, 50/60 Hz LINE

Neutral

201
ERV CONTROLLER
Model: ERV-AC / EC 500 - PHE / HRW

ERV CONTROLLER
Model: ERV-AC / EC 500 - PHE / HRW

DESCRIPTION
The ERV 500 series of electronic speed controllers provide an effective means of regulation
for voltage controllable single-phase AC motors. It’s categorized according to the ERVs
DISCRIPTION
specification i.e. ERV with HRW or PHE and ERV with AC or EC motors. All controllers are
The ERV
electronic based and500
haveseries
ON/OFF of electronic
switchingspeed
optioncontrollers
along withprovide an effective
speed control. means of
It controls the
regulation
fan voltagethe
by ERVs for voltagetocontrollable
PWMspecification
signals regulate single-phase
the output AC motors.
voltage with It’s categorized
minimum according
power Ittois
loss. All
i.e. ERV with HRW or PHE & ERV with AC or EC motors.
a very highly efficient are
controllers speed regulator
electronic with
based andthehas
precise
ON/OFFstep regulation
switching using
option potentiometer.
along with speed
control. It control the fan voltage by PWM signals to regulate the output voltage with the
TECHNICALminimum
SPECIFICATION
power loss. It is very high efficient speed regulator with the precise step
regulation
Input Voltage : 230VACusing potentiometer.
50/60 Hz
Output : Controlled voltage output
TECHNICAL
Power : 500W SPECIFICATION
for both fan
Input Voltage
Storage Temperature : 230VAC
: -15°C 50/60 Hz
to +50°C
Operating Temperature : 0°C voltage
Output : Controlled to +50°Coutput
Power : 500W for both fan
CONSTRUCTION
Storage Temperature : -15˚C to +50˚C
• Single supply input.
Operating
• Dual output for twoTemperature : 0˚C to +50˚C
fan regulation.
• Separate ON/OFF switch
CONSTRUCTION for both the fan.
• Separate ON/OFF light indication
• Single supply Input
for both the FAN.
• ABS enclosure design.
• Dual output for two fan regulation
• IP55 approved.
• Separate ON/OFF switch for both the fan
• Water repellent.
• Separate ON/OFF light indication for both the FAN
• Shock proof enclosure body.
• ABS enclosure design
• Easy installation.
• IP65 approved
MODELS • Water repellent
• Shock proof enclosure body
• ERV AC500-PHE
• Easy installation
• ERV AC500-HRW
• ERV EC500-PHE
MODELS
• ERV EC500-HRW
• ERV AC500-PHE
• ERV AC500-HRW
• ERV EC500-PHE
• ERV EC500-HRW

sez.
DIMENSIONS AND WIRING DIAGRAM PHE / HRW
8 Dimensions in mm
Dimensions and wiring diagram PHE / HRW
130 80 130 80

PHE HRW
130

130
75

75

Ph N

SUPPLY FAN

RETURN FAN SUPPLY FAN INPUT POWER RETURN FAN INPUT POWER

HRW

Ph N Ph N Ph N
Ph N Ph N Ph N

202
TWIN FAN CONTROLLER
Model: AC-02/04

DESCRIPTION
Twin fan controller model AC-02/04 is designed using microcontroller technology and
it is capable to operate two fans as per the programmed time sequence. This control-
ler has an in-built diagnostic and controlling function, few key features as listed below:

FEATURES:
• User-friendly programming steps.
• Controller can be configured to either Auto or Manual mode.
• Auto Mode is further divided into Air sense mode, Current sense mode or Air-current
sense mode.
• Manual mode is also divided into Air sense, Current sense mode or Air-current sense
mode.
• Programmable cycle timer from 1 to 12 hours.
• Seven segment display and LED indicators for better programming and fault moni
toring features to enhance the user experience.
• Building Management System (BMS) status indication through volt free relay con
tacts.
• Designed to operate directly on 220V/50Hz/60Hz at 2amps or 12 amps, single phase
motor.
• Option with 220V control voltage to connect three-phase motor through appropriate
programming along with power module.
• Programmable over current protection features.
• In built fusible link as standard features.
• Actual size: 175 X 175 X 75 mm.
• Weight: 820 gm.

DIMENSIONS AND WIRING DIAGRAM AC-02-04


Dimensions in mm

175 75 sez.

8
175

CONNECTOR INFORMATION
FAN2-P

FAN1-P

NUTRL
FAN2-N
FAN1-N

SPEED REG
SPEED REG
ETH
PHASE
EMRG STOP
FAN2-FAULT
STAT

FAN1-FAULT
STAT

STAT

STAT

AUTO STAT

AIRSW1

AIRSW2
FAN2 RUN

FAN1 RUN

203
SPEED REGULATORS
The products may be subject to updates: please always check the correct pairing according to the motor data plate.

ELECTRONIC

Motor Single-phase
Model Code Type current
R16 R18 R20S
A
0.8A 2.1 A 0.8A

TMF-LINE METAL 75 2AX1122 VU 0,13 •


TMF-LINE METAL 100 2AX1123 VU 0,23 •
TMF-LINE METAL 125 2AX1332 VU 0,13 •
TMF-LINE METAL 140 2AX1333 VU 0,23 •
TMF-LINE METAL 150 2AX1598 VU 0,14 •
TMF-LINE METAL 160 2AX1599 VU 0,37 •
TMF-LINE METAL 200 2AX1687 VU 0,14 •
TMF-LINE METAL 250 2AX1688 VU 0,5 •
TMF-LINE METAL 315 2AX2131 VU 0,5 •
BOX-D 3/8 M 1BX0700 VU 0,3 •
BOX-D 7/7 A6 M 1BX0760 VU 0,6 •
BOX-D 7/7 B4 M 1BX0745 VU 1,2 •
BOX-D 9/7 A6 M 1BX0980 VU 1,5 •
sez.

8 BOX-D 9/7 B4 M 1BX0974 VU 3,6 •


BOX-D 9/9 A6 M 1BX0960 VU 1,8 •
BOX-D 9/9 B4 M 1BX0961 VU 4,4 •
BOX-D 10/8 A6 M 1BX1096 VU 3,6 •
BOX-D 10/8 B4 M 1BX1084 VU 3,6 •
BOX-D 10/10 A6 M 1BX1116 VU 3,1 •
BOX-D 10/10 B4 M 1BX1104 VU 4,6 •
BOX-D 12/9 A6 M 1BX1237 VU 7,6 •
BOX-D 12/12 A6 M 1BX1239 VU 6 •
DYNAIR-60HZ-GULF-14JAN2021

204
Maico Gulf L.L.C
P.O.Box 9014, Al Ghail Industrial Park, Ras Al Khaimah, U.A.E
Tel. +971 7 258 9000, Fax. +971 7 258 9001

enquiry@maicogulf.com
www.maicogulf.com
DYNAIR-60HZ-GULF-14JAN2021

Features and technical data can vary without prior notice without modifying the main functional parameters of the products.
All trademarks mentioned are the property of Maico. All rights reserved.
)NCASEOFANYCLARIlCATIONKINDLYCONTACT-AICO'ULFFORTHEUPDATEDVERSION
JET FANS
Car Park Ventilation Systems

BASIC PRINCIPLE
The ventilation of enclosed or underground car parks fulfills two key requirements: removes the pollutants emitted by cars and in the event of a fire,
control the hot fumes and gases produced by the fire, protecting the escape routes and easing access for the emergency teams.

SPECIAL TECHNOLOGY
In recent years, the jet or induction fans technology has been established as the new standard for normal ventilation and smoke
extraction in case of fire in enclosed car parks.

In fact, this technology represents the most innovative and cost-effective alternative to traditional ducted mechanical extraction systems. Carefully
managing the project in all its development stages, which requires the fundamental use of fluid dynamics calculation programs, also ensures that the
system is working correctly.

CC-JD HT
JET FAN Impulse Fans for
car park ventilation

CC-JC HT
Centrifugal Induction Fans For Car Park Ventilation

The JET FANS system provides either normal ventilation and can also be provided for smoke extract,
in case of fire in underground car parks, or a combination of both, i.e. a dual purpose fan.

70
OPERATION

The fully integrated JET FANS developed by DYNAIR includes three ventilation elements, some CO (carbon monoxide) detection sensors, a control
panel and a CFD analysis; these are the essential requirements to design the most suitable ventilation system for a specific car park.
The system is based on placing a set of axial impulse fans JET FANS all along the parking area, which operate in a similar way to a ducted system. When
installed on the ceiling, they move the air from the top layers to the bottom layers towards the exhaust areas; by effectively creating a continuous air flow,
the fans are able to thoroughly cleanse the air at the bottom and the top layers of the car park, avoiding the creation of areas where air gets trapped.

JET FANS system is completed by air inlet devices operated by natural air or mechanical devices (parking access ramp, natural ventilation ducts, side openings or
inlet fans) and exhaust fans.

TA HT

TA HT

Normal ventilation
JET FANS effectively ventilate both, the bottom layer near the ground and the top layers near the ceiling,
avoiding the creation of areas where air gets trapped. The fans are only operated when the CO
(carbon monoxide) detectors detect a level of pollution higher than the preset threshold value
(which varies according to the type of project and local legislation).

2 3 4

A fire starts The ventilation system starts running The fire smoke is exhausted

Smoke extract in case of emergency


The mechanical fume extraction ventilation system based on JET FANS can easily be split into control areas in order to reduce the effects of fumes only to the area
affected by the event. This system has the advantage of causing the overpressure of the fire fighting sections and the under pressure of the site of the fire, stopping the
fumes from spreading. It drastically reduces the temperature of the area affected by the fire and is not affected by external weather conditions (wind pressure) or events
like cold fumes that tend to lag in the bottom layers (at human height).

71
BENEFITS OF JET FANS & SYSTEM DESIGN

Compared to a ducted ventilation system, the innovative JET FANS system ensures multiple benefits in terms of low cost and efficiency associated
with its design, installation, operation and usage.

DESIGN
• The compact size of the JET FANS allows to optimise the spaces and their flexibility of installation when
building new properties or refurbishing and/or certifying existing buildings.
• It saves design time as it does not require a complex ducted system to be designed and implemented.
• The system effectiveness can be measured with CFD (fluid dynamics calculation) modelling.
• It allows the project designer to benefit from a better pre-sales customer service.
• The project can be financially assessed within 24 hours.
• Final costs are in line with expected costs.

INSTALLATION
• It removes the need for costly and complex ducted and grilled systems.
• The fans are easy to install, ensuring time saving in terms of hours of work.
• The reduced size of the fans eases installation of other systems (sprinklers, lighting, etc).
• Ease of scheduled and breakdown maintenance.

OPERATION
Major savings in running costs ensured by the system distinctive features:
• Ventilation can be fully or partly operated: the CO (carbon monoxide) detectors and the smoke sensors,
in fact, ensure that only the ventilators located in the areas where pollution levels are exceeded or where
a fire has started are enabled.
• Less total power required as the accurate design ensures the optimal size of the ventilation system; more
specifically, the inlet and exhaust fans can be smaller as the JET FANS generate a negligible pressure
drop compared to ducted systems.

USE
• Better quality of breathable air: the JET FAN system creates a continuous airflow able to mix the different layers
of air and to avoid areas where air gets trapped;
• Optimised safety in the event of a fire. Fast and effective toxic fume extraction, leading to safer escape routes,
easier access for the emergency teams, promoting people safety and minimising the effects of fire on the build-
ing structures.

FROM DESIGN TO CUSTOMER SERVICE


Designing a car park ventilation system requires assessing issues associated with fluid dynamics. The high complexity of fluid dynamics
calculation is well known. Manual calculation increases the risk of making mistakes, compromising the correct operation of the ventilation
system designed and, therefore, users' health and safety.

During this crucial design stage, DYNAIR is able to offer real and valuable engineering support, thanks to the experienced and highly skilled
technical staff, who boasts an in-depth knowledge of the CFD software, an advanced computational fluid dynamics calculation tool.

HOW IT WORKS
CFD calculation is essential to ensure that all areas of the car park are correctly ventilated
and, in the event of fire, fume extraction is optimised. It is also required to establish the ac-
curate size of the ventilation system and the correct positioning of the JET FANS and of other
exhaust and/or inlet fans.

This calculation is based on simulation, combining variables such as the required number
of air changes/hours (established by local legislations), air volume, direction and structural
features of each car park (in a 3D model). The processed data generate dynamic scenarios
based on air speed profiles, particle movement and airflow distribution. This allows a cus-
tomised solution to be produced. This methodical approach ensures not only to assess the
systems effectiveness but also the most cost-effective solution as over-sized projects are
avoided.

3D MODELLING OF THE CAR PARK AND ITS DIFFERENT SECTIONS


At this level of calculation, only the geometrical and mathematical conditions required by the
model are known (bounding conditions of the system).

72
SYSTEM DESIGN AND SERVICES

CALCULATION SET-UP AND SCENARIO DEVELOPMENT


Introduction of boundary conditions and initial conditions such as external pressure and out-
side air temperature; structural parameter set-up (light wells, access ramps, etc.) and oper-
ating conditions set-up (material definition, assignment of air performance curve to the fan
model), mesh definition (quantity of primary volumes the model must be split into).

Data processing and assessment of each scenario by changing the type, quantity and position
of the JET FANS.

ANALYSING THE RESULTS AND DEVELOPING A BALANCED SOLUTION


The data can be analysed by checking the air speed inside each section of the car park.
The graphs shown below represent the average air speed on a sectional floor.

FINAL SCENARIO
During this last stage, system effectiveness is put to the test. DYNAIR is able to assist you with its know-how and experience during each stage of the ventilation
project for car parks based on the JET FANS system.

CERTIFICATIONS AND MONITORING SYSTEMS


Fire fighting fan design and installation is regulated by the European reference standard EN 12101-3, which establishes the temperature ranges/
operation time certified products must comply with. DYNAIR fire smoke extraction JET FANS are CE certified to class F300 in compliance with
EN 12101-3 standard and are guaranteed to operate at 300°C for 2 hours. TA-HT series used in combination with JET FANS as exhaust fans
are certified in class F300 and F400.

High temperature resistance scheme

Time since beginning of the test

73
CC-JD HT
JET FANS Impulse Axial Fans For Car Park Ventilation

DESCRIPTION
Axial impulse fans suitable for installation in underground car parks and/or tunnels, especially de-
signed and certified for fire smoke and hot gases extraction in case of fire. CC-JD HT are “dual
purpose” fans, i.e. they can provide both normal ventilation (carbon monoxide removal) and smoke
extract in case of fire.
In the standard configuration for normal ventilation (CO extract), the series can be used at the
temperature of +50°C temperature range. The fire smoke extraction models (HT) are CE certified to
F300, F400 class, in compliance with standard EN12101-3 and are guaranteed to operate at 300°C
and 400°C for 2 hours by the independent notified body Applus.
The special impulse induction fans technology represent the most innovative and cost-effective
alternative to traditional duct mechanical extraction systems; the drastic reduction of installa-
tion costs (complete removal of ducted and grilled systems) and the considerable running cost
savings ensured by the system distinctive features (ventilation/extraction can be partial and
only if necessary) are only two of the multiple benefits of car park ventilation systems based
on JET FANS.

CONSTRUCTION
• Silencers in pre-painted galvanized steel sheet inside lined with high performance acoustic insula-
tion material.
F300/120 • Deflector on the side of the outlet for optimum air discharge and air cleaning of all layers. supplied
as standard.
• Protection guard on inlet side.
F400/120 • Fixing brackets in galvanized steel sheet for ceiling (or wall) installations. Supplied as standard and
pre-assembled.
• Silencers are fitted at both ends with an especially designed smooth bell shape to improve air
performance and reduce losses and sound level.
• Housing in steel sheet protected against atmospheric agent epoxy paint.
• Hub impeller and airfoil profile blades made in aluminum. Balanced according to ISO 1940 G.6.3.
Variable pitch angle in still position.
• Terminal box IP66 is resistant to high temperature and supplied as standard.

MOTOR
Asynchronous three-phase motors 380V 60Hz according to international standards IEC 60034, IEC
60072, EMC 2004/108/CE, LVD 2006/95/CE. Motors suitable for DOL (Direct On Line) start. CE
marked. Protection IP55, class F or H. Execution 4 (with impeller directly coupled to motor with feet).

UPON REQUEST
• Versions for the sole normal ventilation (CO extraction) (CC-JD).
• Sizes up to Ø 1000 mm.
• Versions with reversible airflow.
• Service switch.

Silencers in PPGL sheet lined with high performance ON REQUEST


acoustic insulation material
Deflector on outlet side for optimum air
discharge and air cleaning of all layers. Fixing brackets in steel sheet protected against Protection on inlet side.
Supplied as standard. atmospheric agent by polyester powder coating

Service switch

IP66, supplied as standard.

Housing in steel sheet protected against atmospheric agent by polyester powder


Silencers are fitted at both ends with an especially designed coating
Hub impeller and airfoil profile blades made in aluminium. Balanced according to
smooth bell shape to improve air performance and reduce ISO 1940 G.6.3. Variable pitch angle in still position.
losses and sound level. Execution 4 (with impeller directly coupled to motor with feet).

74
PERFORMANCE CC-JD HT

TECHNICAL DATA FOR 60 Hz


Motor Power Rated Current Temperature Class
Type Model Speed (Rpm) Power Supply
(Kw) (A) °C

CC- JD 312 3500 0.75 1.79 380/3/60Hz -20/+50 C


CC- JD- HT 312 3500 0.75 1.79 380/3/60Hz
F300, F400/ 2HRS
CC- JD- HT 312/4 3500/1750 0.75 /0.12 1.79 /0.46 380/3/60Hz

CC- JD 402 3500 1.50 3.54 380/3/60Hz -20/+50 C


CC- JD- HT 402 3500 1.50 3.54 380/3/60Hz
F300, F400/ 2HRS
CC- JD- HT 402/4 3500/1750 1.5 /0.25 3.54/1.05 380/3/60Hz

PERFORMANCE DATA
Air Flow Air Speed Thrust Lp
Type Model (m³/s) (m/s) (N) (dB(A)@3m)

CC- JD 312 1.37 18.61 31 75

CC- JD 402 3.05 25.7 94 78

CC- JD- HT 312 1.37 18.61 31 75

CC- JD- HT 312/4 1.37/0.69 18.61/9.4 31/8 75/61

CC- JD- HT 402 3.05 25.71 94 78

CC- JD- HT 402/4 3.05/1.54 25.7/12.28 94/23 78/64

On Request: Reversible version CCJR is available in both models and in single and double speed.

DIMENSIONS

Model A B øC D E F G H I Kg

CC- JD 310 415 375 415 240 620 200 134 1585 66 65

CC- JD 400 500 460 500 270 800 230 134 1965 68 80

75
CC-J C HT
Centrifugal Induction Fans For Car Park Ventilation

DESCRIPTION
Centrifugal induction fans designed and suitable for installation in underground car parks and/or
tunnels, especially designed and certified for fire smoke and hot gases extraction in case of fire. CC-JC
HT are “dual purpose” fans, i.e. they can provide both normal ventilation (carbon monoxide removal)
and smoke extract in case of fire.

The series is suitable for continuous running at the temperature of +50°C and is CE certified to F300
class in compliance with standard EN12101-3 and guaranteed to operate at 300°C for 2 hours, 400°C
for 2 hours by the independent notified body Applus.

The special impulse and induction fans technology represents the most innovative and cost-effective
alternative to traditional duct mechanical extraction systems; the drastic reduction of installation costs
(complete removal of ducted and grilled systems) and the considerable running cost savings ensured
by the system distinctive features (ventilation / extraction can be partial and only if necessary) are only
two of the multiple benefits of car park ventilation systems based on CC-JC/D fans.

CONSTRUCTION
• Hub impeller and airfoil profile blades made in steel sheet. Balanced according to ISO 1940.
• Housing in steel sheet protected against atmospheric agent HDG.
• Protection guard on inlet side.
• Fixing brackets in HDG steel sheet for ceiling/wall installation are supplied pre-assembled.
• External terminal box resistant to high temperature.
F300/120
MOTOR
F400/120 Asynchronous three-phase double polarity motor 380V-60 Hz suitable to work up to a maximum tem-
perature of 50°C (service S1) and 300°C/400°C for 120 minutes in case of fire emergency (service
S2). CE marked, IP55 protection, Class H. Execution 5 (Impeller directly coupled on the motor shaft).

UPON REQUEST
• Service switch mounted, suitable for high temperature.
• Polyester powder coating.

Protection guard on
inlet side.

Fixing brackets in galvanized


Long casing in HDG
steel sheet for ceiling (or wall)
installation. Supplied as standard
and pre-assembled.

Motors are totally enclosed IP55,


Class F/H (Fire rated). (Designed for
S1 continual operation).

Terminal Box IP66, tested and


guaranteed for high temperature.

76
PERFORMANCE CC-JC HT

TECHNICAL DATA FOR 60 Hz


Motor power Rated Current Power Supply Temperature Class
Type Model Speed (Rpm) (Kw) (A) (V/Hz) °C

CC- JC-HT 250 1735/860 1.20/0.30 3.02/1.14 380/3/60Hz -20 /+50 C &
CC- JC-HT 300 1755/870 2.20/0.55 5.5/2.47 380/3/60Hz F200, F300, F400/ 2HRS

PERFORMANCE DATA FOR STANDARD MODEL


Air Flow Air Speed Thrust Lp
Type Model (m³/s) (m/s) (N) (dB(A) @3m)

CC- JC-HT 250 1.30 22.5 35 63

CC- JC-HT 300 2.55 28.6 90 68

PERFORMANCE DATA FOR COMPACT MODEL


Air Flow Air Speed Thrust Lp
Type Model (m³/s) (m/s) (N) (dB(A)@3m)

CC- JC-HT 250 1.30/0.8 22.5/12.9 35 63/49

CC- JC-HT 300 2.55/1.07 28.6/16.4 90 68/53

TERMINAL BOX

FOR STANDARD MODEL


Model MODEL A B C D E F G H Kg

CC- JC- HT 250 930 880 830 215 418 1592 1652 267 125

CC- JC- HT 300 1124 1074 1000 231 548 1907 1967 320 175
DYNAIR-60HZ-HT-GULF-14JAN2021

FOR COMPACT MODEL


Model MODEL A B C D E F G H Kg

CC- JC- HT 250 930 880 830 215 465 1206 1206 262 110

CC- JC- HT 300 1124 1074 1000 231 575 1463 1463 345 140

77
78
Maico Gulf L.L.C
P.O.Box 9014, Al Ghail Industrial Park, Ras Al Khaimah, U.A.E
Tel. +971 7 258 9000, Fax. +971 7 258 9001

enquiry@maicogulf.com
www.maicogulf.com
DYNAIR_60HZ_HT_GULF_14JAN21

Features and technical data can vary without prior notice without modifying the main functional parameters of the products.
All trademarks mentioned are the property of Maico. All rights reserved.