You are on page 1of 4

‫ايتكس شركة المعدات والخدمات الفنية‬

EQUIPMENT AND TECHNICAL SERVICES CO. (ETECHS)


Ref #: ETH-FAS-2021186-Q
Date: 30th JUN, 2021

Attn. ENG. MOHAMMAD

Project Name: SADIAH PROJECT

Subject: FIRE FIGHTING SYSTEM

Dear Sir,

With reference to your inquiry, please find below our quotation with our prices for the
below scope of work.

DESIGN, SUPPLY AND INSTALLATIN FIRE FIGHTING SYSTEM (FM200)

Terms & Conditions:


➢ Payment Terms: -

• To be discussed later

➢ Delivery Place: -
• Project Site.

➢ Validity of our offer: -


• 30 Days from the date of submission of our offer.

Page 1 of 2
‫ايتكس شركة المعدات والخدمات الفنية‬
EQUIPMENT AND TECHNICAL SERVICES CO. (ETECHS)

Our Main Offer: -

Summary

Total Price before VAT SAR 226,781

VAT 15% SAR/ 34,017.15

Grand Total Price after VAT SAR/ 260,798.15

We hope that our prices will meet your requirement and further if you need any assistance
or clarifications in this regard, please feel free to contact the undersigned at your earliest
convenience.

Bahaa Alsayes Bassam Alhajahmad


Sales Engineer Director- Sales & Business Development
Tel.: +966 1 4505040 ext. 244 Tel.: +966 1 4505040 ext. 222
Mob +966 558886976 Mob +966 500 134 478
bahaa.alsayes@etechsco.com bassam.alhajahmad@etechsco.com

Page 2 of 2
COST CONFIGURATION

EQUIPMENT & TECHNICAL SERVICES CO. (ETECHS)


Project Name :

SADIA
Client Inquiry Ref No. inquiry by Inquiry Date
BETA Co ETH-FAS-2021186-Q 44,369
Type of system Started on Completed on Config No
FM200 GAS SUPPRESSION SYSTEM 27-Jun-21 27-Jun-21 CA-047-2021

SN Item Description Brand/Make Qty Unit Unit Cost Total Cost

DESIGN, SUPPLY, INSTALL, TEST AND COMMISSIONING OF FM200 GAS


SUPPRESSION SYSTEM FOR THE BELOW ROOMS AS PER CLIENT
PROVIDED INFORMATIONS.

FM200 Gas Suppression System consist of DOT Approved Cylinders,


discharge Hose, System Actuators, cylinder brackets and supports, discharge
Nozzles, Pressure Switch, Nameplates, Warning Signs, Detection and alarm
Components for the Following Rooms :

IT Room 4 - Zone 1 ; Room Volume = 11.06m³; FM200 Gas agent required = 7


1 1 Lot 18,179 18,179
Kgs each in 1 x 8 Liter Cylinder ( Main ONLY) Ditto

IT Room 5 - Zone 2 ; Room Volume = 21.76m³; FM200 Gas agent required = 12


2 Ditto 1 Lot 18,897 18,897
Kgs each in 1 x 16 Liter Cylinder ( Main ONLY)

IT Room 6 - Zone 2 ; Room Volume = 12.89m³; FM200 Gas agent required = 7


3 Ditto 1 Lot 18,117 18,117
Kgs each in 1 x 8 Liter Cylinder ( Main ONLY)

IT Room 7 - Zone 3 ; Room Volume = 10.88m³; FM200 Gas agent required =


4 Ditto 1 Lot 18,055 18,055
6 Kgs each in 1 x 8 Liter Cylinder ( Main ONLY)

IT Room 8 - Zone 3 ; Room Volume = 31.99m³; FM200 Gas agent required = 18


5 Ditto 1 Lot 19,978 19,978
Kgs each in 1 x 32 Liter Cylinder ( Main ONLY)

IT Room 9 - Zone 3 ; Room Volume = 21.76m³; FM200 Gas agent required


6 Ditto 1 Lot 18,897 18,897
= 12 Kgs each in 1 x 16 Liter Cylinder ( Main ONLY)

IT Room 10 - Zone 4 ; Room Volume = 10.88m³; FM200 Gas agent required


7 Ditto 1 Lot 18,055 18,055
= 6 Kgs each in 1 x 8 Liter Cylinder ( Main ONLY)

IT Room 11 - Zone 4 ; Room Volume = 21.76m³; FM200 Gas agent required =


8 Ditto 1 Lot 18,959 18,959
12 Kgs each in 1 x 16 Liter Cylinder ( Main ONLY)

Electrical Room 1, Zone 1 ; Room Volume = 43.30m³; FM200 Gas agent required
9 Ditto 1 Lot 20,767 20,767
= 24 Kgs each in 2 x 32 Liter Cylinder ( Main ONLY)

Electrical Room 2, Zone 2 ; Room Volume = 20.61m³; FM200 Gas agent required
10 Ditto 1 Lot 18,959 18,959
= 12 Kgs each in 2 x 16 Liter Cylinder ( Main ONLY)

Electrical Room 3, Zone 3 ; Room Volume = 20.61m³; FM200 Gas agent required
11 Ditto 1 Lot 18,959 18,959
= 12 Kgs each in 2 x 16 Liter Cylinder ( Main ONLY)

Electrical Room 4, Zone 4 ; Room Volume = 20.61m³; FM200 Gas agent required
12 Ditto 1 Lot 18,959 18,959
= 12 Kgs each in 2 x 16 Liter Cylinder ( Main ONLY)

TOTAL COST OF ALL THE ABOVE SAR 226,781

NOTES:
The above Price is for Design, Supply and Installation the FM200 Gas Suppression System for the above mentioned Rooms based f rom the client provided
1 Room dimensions, NFPA 2001 and Manufacturer Standards. Any Descripancy between the above quantities and actual site requirements will be charged as
change order.

Page1 of 2
COST CONFIGURATION

The above Offer will be Designed using 7.0% Design Concentration at 21°C ambient room temperature having 25 bars working pres sure MAIN Cylinder ONLY.
2 All cylinders will be designed to be located within or as near as possible to the Protected Room.

Air Tightness of the hazard/ rooms protected by Gas Suppression System shall be done by the client prior to performing the Room Integrity Testing, to ensure
3
that the design volumetric concentration is attained during gas discharge for a period of 10 minutes holding time

Pipes are Black Seamless Steel Pipes, Sch. 40 with Forged threaded class 3000 Lbs fittings for pipe size 50mm dia and smaller , Grooved mechanical fittings for
4
pipe size 65mm dia and larger.

5 EXCLUSIONS :
a. All Civil works of any kind.
b. Actual gas Discharge Test
c. Factory Acceptance Test and Outside of Kingdom Trainings / Seminar
d. Interfacing of our system to the Main Fire alarm control Panel or BMS
e. Spare parts
f. Supply and Installation of Fire Dampers, Fire Curtains, Any Door Closer or Magnetic Door closers, etc
g. Additional Gas Agent for Ceiling and or floor Voids.

6 We Reserve the right to amend this proposal in the event of any changes.

Page2 of 2