Professional Documents
Culture Documents
J (5/08)
Modular Messaging
Siemens HiPath 4000
T-1 QSIG
Message
Siemens HiPath 4000 Application
Server
Message Waiting
Automated Attendant
T1
TRUNK T1 Line Return to Operator
Boards
Interface
Call ID
CPU
Overview
This Configuration Note is intended for Avaya certified Modular Messaging
technicians/engineers who are familiar with Modular Messaging procedures and
terminology. It also assumes that you are Siemens certified or very familiar with
the features and functionality of the Siemens PBX supported in this
Configuration Note and the QSIG protocol.
Use this document in conjunction with Modular Messaging Installation Guide
and the Siemens PBX Administration Guide.
Please read the entire document before attempting any configuration.
Disclaimer: Configuration Notes are designed to be a general guide reflecting AVAYA Inc. experience configuring its systems. These
notes cannot anticipate every configuration possibility given the inherent variations in all hardware and software products. Please
understand that you may experience a problem not detailed in a Configuration Note. If so, please notify the Technical Assistance
Center at (800) 876-2835, and if appropriate we will include it in our next revision. AVAYA Inc. accepts no responsibility for errors or
omissions contained herein.
Siemens HiPath T1/QSIG 2
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 3
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 4
<DIS-BUEND
TGRP = 90
FORMAT = L
DIS-BUEND:90,L;
H500: AMO BUEND STARTED
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 5
|----------------------------------------------------------------------|
| BCNEG = N BCGR = 1 LWPAR = 1 |
| LWPP = LWLT = LWPS = |
| LWR1 = LWR2 = |
| SVCDOM = |
| BCHAN = 1 && 23 |
| |
+----------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 23
COP: 90 INFO:
DEVICE: INDEP SOURCE: DB
PARAMETER:
LINE WITH START-DIAL-SIGNAL SDL
SPECIAL MODE SFRM
REGISTRATION OF LAYER 3 ADVISORIES L3AR
START-DIALING-SIGNAL TIMER 1 (AMO DTIM2: PARAMETER STADIAL1) TIM1
<DIS-COT:90;
DIS-COT:90;
H500: AMO COT STARTED
COT: 90 INFO:
DEVICE: INDEP SOURCE: DB
PARAMETER:
RECALL IF USER HANGS UP IN CONSULTATION CALL RCL
KNOCKING OVERRIDE POSSIBLE KNOR
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
UNRESTRICTED SUFFIX DIALING USD
NETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBN
NETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFN
REGISTRATION OF IMPLAUSIBLE EVENTS IEVT
END-OF-DIAL FOR BLOCK IS SET BLOC
SEND NO NODE NUMBER TO PARTNER LWNC
CONNECTION TO ROUTE OPTIMIZATION NODE ROPT
LAST REDIRECTING NUMBER IS SEND TO PHONEMAIL LRPM
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
TSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCS
USE DEFAULT NODE NUMBER OF LINE DFNN
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR (DATA) NLRD
LINE WITH IMPLICIT NUMBERS LINO
NO SIMPLE DIALOG AVAILABLE NOSD
RESERVED ELEMENT R251
NO TONE NTON
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 6
Note: Ensure AOCC is not present on the COT, as this will prevent Call
ID transfers failure from the Attendant Console.
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 7
<DIS-COSSU:LCOSD,1;
DIS-COSSU:LCOSD,1;
H500: AMO COSSU STARTED
+----+------------------------------------------------------------+-----+
|LCOS| LAUTH |
| D | 1 2 3 4 5 6 |
|1234567890123456789012345678901234567890123456789012345678901234|COPIN|
| |>SERVICE INFORMATION |NUM |
+----+----+----|----+----|----+----|----+----|----+----|----+----|--+---+
| 1|X..........................................................| . |
+----+------------------------------------------------------------+--
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 8
<DIS-ZAND:ALLDATA2;
DIS-ZAND:ALLDATA2;
H500: AMO ZAND STARTED
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 9
TRCCSN7 = NO , FWDUNDTR = NO
COSIND = NO , TRANSCO = NO
ANSES = NO , OLISFREE = ONHOOK ,
TEXTDISP = CENTER, PABXSELL = HICOM ,
DSPOWNNO = YES , DIRREC = NO ,
CSDTYPE = STANDARD, CONFTNCD = NO ,
LNR = YES , ROLCKVCM = NO ,
FACBUF = 1 , VCMTRANS = NO ,
HOWLTONE = NO , DISPNUUN = PRIVATE NUMBER ,
DISPTGNA = YES , POSTDRED = NO ,
GRCALL = NO , MAILSCRL = NO ,
ACTIVE TEXTSEL = AMERICAN ,
RELOAD TEXTSEL = AMERICAN ,
INDNADIS = YES , UUS = DIV,
NOCFWTAC = NO , ISYNCHG = NO
ROUTTONE = NO , SOFTREST = SIMPLEX ,
CALWTANA = NO , CBPBUSY = YES ,
SWSTAT = YES , VIRSUBNO = NO ,
ECN = ,
OOSTONE = NO , TYPEDNIS = INTDNIS ,
CONFTONE = YES , DISPTONE = YES ,
CAMPON = YES , USRINGTY = K;
<DIS-ZAND:ALLDATA3
DIS-ZAND:ALLDATA3;
H500: AMO ZAND STARTED
ALL SYSTEM-DATA 3:
==================
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 10
Ensure the Trunk Route include the proper info with the following data:
<DIS-RICHT:CD
CD =
DPLN =
CPS =
SVC =
TGRP =
LRTE =
DNNO = 0-0-90
ROUTOPT =
DISPL =
DIS-RICHT:CD,,,,,,,0-0-90,,;
H500: AMO RICHT STARTED
------------------------------------------------------------------------+
| ROUTES FOR ALL DPLN SVC = VCE |
+-------+------------------+----+-+------------------------------+----+--
|CODE |NAME, CQMAX, |TGRP|P| DTMF |LRTE|CPAR| F|
| |DESTNO AND CPS |CCNO|L+---+---+---------------+-----+ | W|
| | 1 111112| |B|CNV|DSP| TEXT |PULS | | D|
| |12345 67890 123452| | | | | |PAUSE| | B|
+-------+------------------+----+-+---+---+----------------------+----+--
|90 |..... ..... ......| 90| | F | W | |PP80 | 90| |
|NEUTRAL|VOICEMAIL | | | | | | | | |
| |DNNO: 90 | | | | | | | | |
These parameters are critical | |PDNNO: 90 | | | | | | | | |
and required for QSIG Path | |DESTNO : 90 | | | | | | | | |
| |ROUTOPT : YES | | | | | | | | |
Replacement | |REROUT : YES | | | | | | | | |
+-------+------------------+----+-+---+---+----------------+-----+----+-+
+-----------------------------------------------------------------------+
<dis-ziel:fwd,3502;
DIS-ZIEL:FWD,3502;
H500: AMO ZIEL STARTED
FWD
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 11
REG-ZIEL:FWD,3502;
H500: AMO ZIEL STARTED
ADD-ZIEL:FWD,3502,VCE,3562,
"",CFB,INT,SYSTEM;
ADD-ZIEL:FWD,3502,VCE,3562,
"",CFNR,INT,SYSTEM;
ADD-ZIEL:FWD,3502,VCE,3562,
"",CFNR,EXT,SYSTEM;
ADD-ZIEL:FWD,3502,VCE,3562,
"",CFDND,EXT,SYSTEM;
ADD-ZIEL:FWD,3502,VCE,3562,
"",CFDND,INT,SYSTEM;
Activate the Forwarding AMO-ZIEL -111 DESTINATIONS FOR VARIOUS STATION FEATURES
REGENERATE COMPLETED;
conditions <reg-actda:stn,3502;
REG-ACTDA:STN,3502;
H500: AMO ACTDA STARTED
ADD-ACTDA:STN,3502,FWD,SYSTEM,,,VCE,;
ADD-ACTDA:STN,3502,OPTISET,2,4,2,1,4,NORMAL,2,3;
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 12
* The DCFWBUSY parameter set to Y will Delay the Call on a Forward or Busy
so that the station will ring briefly before going covering to voice mail. If you
set this to N the call will forward immediately to Voice Mail and not ring.
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 13
Ensure a Mailbox (MB) key is associated with the digital sets to access
MM.
<dis-tapro:std,1,optiset;
DIS-TAPRO:STD,1,OPTISET;
H500: AMO TAPRO STARTED
+-----+---------+----------------------------------------------------------+
| STD | DIGTYP | "SERVICE INFORMATION" KEY LAYOUT
+-----+---------+----------------------------------------------------------+
| 1 | OPTIT12 | "8 KEYS I.M. STD 1: ENTRY 8 ALTERNATIVE " |
| | | 1 ACDLOG 2 ACDAV 3 ACDNAV 4 ACDWORK 5 MB |
| | | 6 HS 7 CONF 8 HOLD 9 FWD 10 LINE |
| | | 11 LINE 12 LINE
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA1 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - -
| | OPTIA2 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - -
| | OPTIA3 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - -
| | OPTIA4 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT
+-----+---------+--------------------------------------------------------
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 14
NOTE: Although these screens were taken from a working system, they are provided here for
illustration purposes only! It is recommended that a qualified Siemens technician
review the customer’s HiPath QSIG programming for accuracy.
<dis-buend
TGRP =
FORMAT = l
DIS-BUEND:,L;
H500: AMO BUEND STARTED
+--------------------------- FORMAT = L --------------------------------+
| TGRP NUMBER : 50 TGRP NAME : T1 LINES MAXIMUM NO. : 30 |
| CHARCON : NEUTRAL |
| SUBGROUP NO.: 1 DEVICE TYPE : S1CONN TRACENO : 0 |
| SEARCH MODE : CIRCULAR ACD THRESHOLD : * |
| NUMBER OF ASSOCIATED ROUTES : 1 PRIORITY : 2 |
| TDDRFLAG : ON TDDRTHRESHOLD: 2 SOURCEGROUPIDX : 1 |
| GDTRRULE : 0 ACDPMGRP : 0 |
| THE FOLLOWING TRUNKS (LTG-LTU-SLOT-CCT) HAVE BEEN ALLOCATED: |
+------------------------------------------------------------------------------+
| 1- 1-103-0 1 | 1- 1-103-0 2 | 1- 1-103-0 3 |
| 1- 1-103-0 4 | 1- 1-103-0 5 | 1- 1-103-0 6 |
| 1- 1-103-0 7 | 1- 1-103-0 8 | 1- 1-103-0 9 |
| 1- 1-103-0 10 | 1- 1-103-0 11 | 1- 1-103-0 12 |
| 1- 1-103-0 13 | 1- 1-103-0 14 | 1- 1-103-0 15 |
| 1- 1-103-0 16 | 1- 1-103-0 17 | 1- 1-103-0 18 |
| 1- 1-103-0 19 | 1- 1-103-0 20 | 1- 1-103-0 21 |
| 1- 1-103-0 22 | | |
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 15
+------------------------------------------------------------------------------+
<dis-tdcsu
PEN1 = 1-1-103-0;
DIS-TDCSU:1-1-103-0;
H500: AMO TDCSU STARTED
+------------------------ DIGITAL TRUNK (FORMAT=L) -------------------------+
| DEV = S1CONN PEN = 1-01-103-0 TGRP = 50 |
|---------------------------------------------------------------------------|
| PROTVAR = PSS1V2 INS = Y SRCHMODE = CIR |
| COTNO = 50 COPNO = 50 DPLN = 0 |
| ITR = 0 COS = 12 LCOSV = 6 |
| LCOSD = 1 CCT = DESTNO = 50 |
| SEGMENT = 1 DEDSCC = DEDSVC = NONE |
| FACILITY = DITIDX = SRTIDX = |
| TRTBL = GDTR SIDANI = N ATNTYP = TIE |
| CBMATTR = NONE NWMUXTIM = 10 TCHARG = N |
| SUPPRESS = 0 DGTPR = CHIMAP = N |
| ISDNIP = ISDNNP = |
| PNPL2P = PNPL1P = PNPAC = |
| TRACOUNT = 31 SATCOUNT = MANY NNO = 50 |
| ALARMNO = 0 FIDX = 1 CARRIER = 1 |
| ZONE = EMPTY COTX = 50 FWDX = 1 |
| DOMTYPE = UNKNOWN DOMAINNO = 0 TPROFNO = |
| INIGHT = CCHDL = |
| UUSCCX = 16 UUSCCY = 8 FNIDX = 1 |
| CLASSMRK = EC & G711 & G729OPT SRCGRP = |
| TCCID = |
|---------------------------------------------------------------------------|
| BCNEG = N BCGR = 1 LWPAR = 1 |
| LWPP = LWLT = LWPS = |
| LWR1 = LWR2 = |
| DMCALLWD = DMCSEC = VNNO = |
| SVCDOM = |
| BCHAN = 1 && 22 |
| |
+---------------------------------------------------------------------------+
AMOUNT OF B-CHANNELS IN THIS DISPLAY-OUTPUT: 22
<dis-cot:50;
DIS-COT:50;
H500: AMO COT STARTED
COT: 50 INFO:
DEVICE: INDEP SOURCE: DB
PARAMETER:
RECALL IF USER HANGS UP IN CONSULTATION CALL RCL
UNRESTRICTED SUFFIX DIALING USD
KNOCKING OVERRIDE POSSIBLE KNOR
CALL EXTEND FOR BUSY, RING OR CALL STATE CEBC
NETWORKWIDE AUTOMATIC CALLBACK ON BUSY CBBN
NETWORKWIDE AUTOMATIC CALLBACK ON FREE CBFN
REGISTRATION OF IMPLAUSIBLE EVENTS IEVT
END-OF-DIAL FOR BLOCK IS SET BLOC
SEND NO NODE NUMBER TO PARTNER LWNC
CONNECTION TO ROUTE OPTIMIZATION NODE ROPT
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR NLCR
TSC-SIGNALING FOR NETWORKWIDE FEATURES (MANDATORY) TSCS
USE DEFAULT NODE NUMBER OF LINE DFNN
INCOMING CIRCUIT FROM SYSTEM WITHOUT LCR (DATA) NLRD
LINE WITH IMPLICIT NUMBERS LINO
LAST REDIRECTING NUMBER IS SEND TO PHONEMAIL LRPM
NO SIMPLE DIALOG AVAILABLE NOSD
AUTOM.DTMF CONVERSION ON INCOM.CALL WHILE IN TALK STATE AMFC
NO TONE NTON
AMO-COT -92 CLASS OF TRUNK FOR CALL PROCESSING
DISPLAY COMPLETED;
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 16
<dis-cop:50;
DIS-COP:50;
H500: AMO COP STARTED
COP: 50 INFO:
DEVICE: INDEP SOURCE: DB
PARAMETER:
LINE WITH START-DIAL-SIGNAL SDL
SPECIAL MODE SFRM
REGISTRATION OF LAYER 3 ADVISORIES L3AR
START-DIALING-SIGNAL TIMER 1 (AMO DTIM2: PARAMETER STADIAL1) TIM1
AMO-COP -92 CLASS OF PARAMETER FOR DEVICE HANDLER
DISPLAY COMPLETED;
<dis-cossu:lcosv;
DIS-COSSU:LCOSV;
H500: AMO COSSU STARTED
+----+----------------------------------------------------------------+-----+
|LCOS| LAUTH |COPIN|
| V | 1 2 3 4 5 6 | |
| |1234567890123456789012345678901234567890123456789012345678901234| |
| |>SERVICE INFORMATION | |
+----+----+----|----+----|----+----|----+----|----+----|----+----|----+-----+
| 1|XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX| 0 |
| |>LCR ATTENDANT FOR DATA | |
| 2|X...............................................................| 0 |
| 3|XX..............................................................| 0 |
| 4|XXX.............................................................| 0 |
| 5|XXXX............................................................| 0 |
| 6|XXXXXX..........................................................| 0 |
+----+----------------------------------------------------------------+-----+
AMO-COSSU-92 CLASSES OF SERVICE
DISPLAY COMPLETED;
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 17
<dis-richt:all;
DIS-RICHT:ALL;
H500: AMO RICHT STARTED
+------------------------------------------------------------------------------+
| ROUTES FOR ALL DPLN SVC = VCE |
| |
+-------+------------------+----+-+------------------------------+-----+----+--+
|CODE |NAME, CQMAX, |TGRP|P| DTMF | LRTE|CPAR| F|
| |DESTNO AND CPS |CCNO|L+---+---+----------------+-----+ | | W|
| | 1 111112| |B|CNV|DSP| TEXT |PULS | | | D|
| |12345 67890 123452| | | | | |PAUSE| | | B|
+-------+------------------+----+-+---+---+----------------------+-----+----+--+
|50 |..... ..... ......| 50| | F | W | |PP80 | 50| | |
|NEUTRAL|VOICEMAIL | | | | | | | | | |
| |DNNO: 50 | | | | | | | | | |
| |PDNNO: 50 | | | | | | | | | |
| |DESTNO :50 | | | | | | | | | |
| |ROUTOPT :YES | | | | | | | | | |
| |REROUT :YES | | | | | | | | | |
+-------+------------------+----+-+---+---+----------------+-----+-----+----+--+
+------+----------------------+------------------------------+--------+
| IDX | SAN | NAME | TYPE |
+------+----------------------+------------------------------+--------+
| 1|6999 |VOICEMAIL |OTHER |
+------+----------------------+------------------------------+--------+
AMO-RICHT-92 TRUNK ROUTING
DISPLAY COMPLETED;
<dis-lodr
ODR = 6;
DIS-LODR:6;
H500: AMO LODR STARTED
+-------------------------------------------------------+
| ODR POSITION CMD PARAMETER |
+--------+----------------------------------------------+
| 6 | 1 ECHOALL |
| | 2 END |
+--------+----------------------------------------------+
H03: THE NEXT FREE ODR IS 7
AMO-LODR -92 ADMINISTRATION OF LCR OUTDIAL RULES
DISPLAY COMPLETED;
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 18
**** Master Dial plan where all stn/trunk/features codes are declared ****
<dis-wabe:gen
CD =
DPLN =
CPS =
DAR = stn;
DIS-WABE:GEN,,,,STN;
H500: AMO WABE STARTED
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 6000 - 6023 |. .**** ***** **... ..... .*| STN | |
| | | |DESTNO 0 |
| | | |DNNO 10- 10-100*|
| 6024 - 6025 |. .**** ***** **... ..... .*| STN | R |
| | | |DESTNO 0 |
| | | |DNNO 10- 10-100*|
| 6026 - 6049 |. .**** ***** **... ..... .*| STN | |
| | | |DESTNO 0 |
| | | |DNNO 10- 10-100*|
| 6050 - 6998 |. .**** ***** **... ..... .*| STN | R |
| | | |DESTNO 0 |
| | | |DNNO 10- 10-100*|
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| CODE | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 6999 |. .**** ***** **... ..... .*| STN | |
| | | |DESTNO 50 |
| | | |DNNO 0- 0- 50 |
| | | |PDNNO 0- 0- 50 |
------------------------------------------------------------------------------
AMO-WABE -92 DIALLING PLANS, FEATURE ACCESS CODES
DISPLAY COMPLETED;
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 19
Note: Confirm these ISDN values with your PBX vendor. If these values
do not match the ISDN protocol, then transfer and out calling will not
work.
* Enter the MAS server pilot number in the Origin Number field
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 20
Next access the Port Groups General tab under the MAS name
1. Click Add Group Button
NOTE: The MWI port within the 2. Name Group MWI
MWI Port Group it’s used by the 3. Within the new MWI Port Group uncheck all Ports except the
MWI sub-system to control MWI port. This will be the upper most port of the Trunk Group.
concurrent MWI requests. This
does not affect incoming/outgoing
Port 23 on a single board, Port 46 if 2 boards, or Port 69 if 3
traffic to the port in anyway. All boards are used (see side NOTE).
MWI function is handled by the D- 4. Select the Default Group under Port Groups and ensure it is
Channel. configured to meet the customer’s need for Incoming and
Outgoing under Port Group Usage.
5. Next check all Ports (including the MWI port).
6. Select OK to save changes
Next access the QSIG General tab within the PBX Type tab
1. Telephony Type = Dialogic QSIG
2. Under PBXs ensure Siemens (Dialogic QSIG) is selected
3. Select OK to save changes
Tip: To make the QSIG or Next access the General tab within the Telephony Interface
set emulation telephony (Dialogic-QSIG) tab
interface active, click the
down arrow and click 1. Playback Volume = 2
Make Active. 2. Maximum Concurrent Calls = Enter the number of ports
If the QSIG or set connected to the PBX (i.e. 23)
emulation telephony 3. Port = Ports are enabled by default
interface is already active, Note: The MAS service must be restarted to allow port disabling
this field does not appear.
4. Select OK to save changes
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 21
8.0 CONSIDERATIONS/ALTERNATIVES
Important notes regarding this
8.1 Within the Voice Mail System Configuration, access the
integration
"Telephone User Interface," and under the "Receptionist" tab, DO
NOT select "Inform Subscriber Transfer is from Auto Attendant"
(leave unchecked). Otherwise we will see issues with tromboning
and Path Replacement.
8.3 Call transfers may not display the Call ID to ringing phones.
The Call ID is not provided until the subscriber answers the
phone. This issue was resolved in MM 3.0.
8.4 MWI will fail if both QSIG T1 spans are configured for QTU.
When configuring the QSIG T1 board (refer to page 4-39 of the
MM Installation Guide) ensure only the first span is configured for
QTU within the Interface tab, under the ISDNProtocol. The
second span should be configured for “none.”
----------
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
Siemens HiPath T1/QSIG 22
CHANGE HISTORY
©2008 AVAYA Inc. All rights reserved. All trademarks identified by the ®, SM and TM are registered trademarks,
servicemarks or trademarks respectively. All other trademarks are properties of their respective owners. The
above information is based on knowledge available at the time of publication and is subject to change without
notice. Printed in U.S.A.
AVAYA Inc.
1033 McCarthy Blvd
Milpitas, CA 95035
(408) 577- 7000
http://www.avaya.com
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1