M106 – Troubleshooting the Infi90 Process Control Unit

Course Description

Course Duration Course Objectives


The duration is 4 days. Upon completion of this course, students will be
able to:
Course Goal • Incorporate Infi-90 Open/Symphony
This course supplies the necessary tools and hardware into process
information needed to troubleshoot the Infi-90 • Interpret ABB Bailey conventional cabinet
Open Process Control Unit from the control arrangement drawings
strategy to the field wiring.
• Setup and maintain modular power systems
Student Profile • Read the field input/output external
This course is beneficial to students who are connection drawings
responsible for DCS component selection, DCS • Utilize the Engineering Workstation to
installation, Process Control implementation and verify operating status of hardware
DCS maintenance. components
• Configure and implement Multi-Function
Prerequisites and Recommendations
Processor (MFP) and various I/O modules
Students should have a basic knowledge of along with their support equipment
process control and operations concepts.
Successful completion of either combination of • Establish MFP redundancy
the M101 or M201 and M103 or M202 courses • Perform on-line configuration
is required unless special permission is • Utilize software tools to troubleshoot the
requested and granted by the instructor. Basic MFP and its I/O modules
knowledge and usage of applications running on
a Windows NT or 2000 operating system is also • Establish/locate troublesome areas data
recommended highway communication

Description Main Topics


This course reviews the features of the Infi90- • Symphony Strategic Enterprise or Infi90
Open Distributed Control System, and Open System Architecture
discusses the Process Control Unit hardware • Composer Automation Architect
components and the role of software in Programming and Documentation
implementing control strategies in the Multi-
Function Processor. “Hands-on” exercises • ABB/Bailey Function Code Program
provide the opportunity to operate, install, and Application
troubleshoot the PCU. • Symphony Strategic Enterprise or Infi90
Open System Diagnostics and
Monitoring
Course Calendar - M106 Troubleshooting the Infi90 Process Control Unit

Day 1 Day 2 Day 3 Day 4


• Introductions • Review: Q/A’s • Review: Q/A’s • Review: Q/A’s
• INFI 90 Overview • Power Sizing • I/O Hardware and • Troubleshooting at
Cfg all Levels
• System Drawings • On-line Cfg.
• On-line Cfg. • Lab
• Infi-Net • I/O Hardware
Communications • Infi-Net to
• I/O Cfg. Computer
• MFP’s Interfaces
• Troubleshoot I/O
• Lab • Status/Problem
• Lab
Reports
• Lab