1.5/1 AH
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (International Test Standard ISO9906:1999 - Grade 2 unless otherwise specified). For media other than water,
corrections must be made for density, viscosity and/or other effects of solids. WEIR MINERALS reserves the right to change pump performance and/or delete impellers without notice. Frame
suitability must be checked for each duty and drive arrangement. Not all frame alternatives are necessarily available from each manufacturing centre.
100 Pump
Discharge 25mm
Suction 38mm
4400 rpm 20%
30% Impeller
40%
45% Vanes 5
48% Vane ø 152mm
50% Type Open
Part No Material
52% B1127 Metal
4000 rpm
75
Frame (Rating - KW)
B 15
50%
Nominal Operation Design Operation
Seal
Flow = 12.4 m³/hr Flow = 15.5 m³/hr
H(SL) = 22.6 m H(SL) = 27.0 m Gland Sealed Pump
3600 rpm H(W) = 22.8 m 45%
H(W) = 27.3 m
NPSHr
Speed = 2244 rpm Speed = 2481 rpm Liner (Norm Max r/min)
Eff = 46.0 % Eff = 48.1 % Metal 4400
N CY
Head, H (m)
Curve
Revision 1
CONSIDERATIONS Revision Notes
8m
2800 rpm EFFICIENCIES UPDATED
TAG 0240-BH-0103-0104
SGslurry = 1.17 Reference
SGsolids = 2.85 TEST 42, 42A - FEB 1989; A4-P-
%Solids = 15 1869/81
6m
Motor 5 HP power
1600 rpm effective at 1000 msal
3.2m
1200 rpm