10 x 10 SRH
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (ANSI/HI 1.6-2000 Centifugal Pump Test Standard unless otherwise specified). For media other than water,
corrections must be made for density, viscosity and/or other effects of solids. WEIR MINERALS reserves the right to change pump performance and/or delete impellers without notice. Frame
suitability must be checked for each duty and drive arrangement. Not all frame alternatives are necessarily available from each manufacturing centre.
70 Pump
Discharge 254mm
Suction 254mm
Impeller
1100 rpm 50%
60% Vanes 4
60 70% Vane ø 533.4mm
Part No Material
75%
IMPC42302 Polymer
79% Seal
1000 rpm
50 Gland Sealed Pump
79% Water Flushed Gland , Hydroseal
®
75%
NPSHr
Liner (Norm Max r/min)
900 rpm
Elastomer 1100
40
Head, H (m)
5410.21mm
EF F
7.62m
Revision 3
30 Revision Notes C
Reference C4-2301
700 rpm Flow = 650 m³/hr Last Issued Dec 94
6.1m
H(SL) = 55,5 mca Issued Dec 94
H(W) = 56 mcp (corrigida)
20 600 rpm
4.57m
Speed = 1094 rpm
Eff = 74,1 %
NPSHr = 4,4 m
3.05m
500 rpm
P = 240 cv
Sm = 1,28
10
400 rpm
Bomba 10X10 SMH A05/A05
1.52m