WEIR BRASIL LTDA TYPICAL PUMP

PERFORMANCE CURVES

WARMAN PUMP IMPELLER: GGH10137


WPA
SIZE FRAME TYPE VANES TYPE IMPELLER MAT'L VANE ø LINER MAT'L
1210C11M
G T 3 Closed Metal 915 Unlined

12/10 GH GLAND SEALED PUMP


ISSUED
JUNE 1985
Frame G T NORMAL MAX. SPEED MIN. PASSAGE SIZE
Rating [kW] 600 1200 700 r/min 210
mm SPHERE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER. (To International Test Standard ISO2548 Class C) : For
media other than water, corrections must be made for density, viscosity and/or other effects of solids. WEIR MINERALS reserves the
right to change pump performance and/or delete impellers without notice. Frame suitability must be checked for each duty and drive © 1998-2021
arrangement. Not all frame alternatives are necessarily available from each manufacturing centre. WEIR WARMAN LTD.

H
(m)

700
40%

50%

r/min
60%

80
REVISION:SPHERE NOTE CHANGED. GENERAL NOTES REVISED.

650 70%
70

73%

70%
600
LAST ISSUE:NOV 1984

60

10 m
8m

NPSH
550
6m

50
4m

500

40
A1-110360/3

NCY

450
EFFICIE

2m

30
400
REF:TEST 1:A4-P-1226&1227 NPSH (P)

350
20
Printed by wsCAT v2.00.0133 25/jun/2021 (4)

10

0
0 500 1000 1500 2000 2500 3000
Q (m³/h)