Main Accessories

All about the options and versions available


ACCESSORIES

Index

✓ Product coding
✓ Energy versions
✓ Hydraulic versions
✓ Acoustic versions
✓ Control panel
✓ Mounted accessories
✓ Loose accessories
ACCESSORIES

PRODUCT CODING

NAME OF THE UNIT (E.G DOMINO SEA)


1 50 Z C D SL B1
Hydraulic version:
B1/M1/A1: 1 pump (150/250/450kPa) and expansion vessel
B2/M2/A2: 2 pumps (150/250/450kPa) and expansion vessel
SB/SM/SA: 1 pump (150/250/450kPa) expansion vessel and water tank
XB/XM/XA: 2 pumps (150/250/450kPa) expansion vessel and water tank
Acoustic version:
LN: Low noise
SL: Super low noise
Energetic version:
D: Desuperheater
R: Total recovery (only for cooling only version)
Basic version:
C: Chiller - H: Heat pump – MA: Air Cooled Multifunctional unit
– CM: Condensing unit – HM: Condenserless unit
Type of compressor
Z: scroll
Nominal cooling capacity
Number of circuits
ACCESSORIES

ENERGY VERSIONS – TOTAL RECOVERY


Coil

Recovery heat exchanger


The recovery activation is managed by the unit control
through a set-point dedicated to the water on the recovery

Heat recovery ONLY during water cooling to the user side


Please see the installation sketches showing mandatory hydraulic acceccories to be installed
on the HVAC systems.
ACCESSORIES

ENERGY VERSIONS – DESUPERHEATER

Desuperheater
The recovery activation
is managed by the
customer through the
activation of the pump
with temperature
sensor on the tank on
the desuperheater side.

Heat recovery ONLY during water cooling to the user side


Please see the installation sketches showing mandatory hydraulic acceccories to be installed
on the HVAC systems.
ACCESSORIES

ENERGY VERSIONS – COMPARISON


REC: 100% heat recovery
DES: recovery 20%
(approx) heating
capacity

liquid GAS
mix
Enthalpy = energy
REC: + recovery; + costs
DES:- recovery; - costs
ACCESSORIES

HYDRAULIC VERSIONS
Single pump version B1/M1/A1 (Low/Medium/High pump pressure)

Pump

Please see the installation sketches showing mandatory hydraulic acceccories to be installed
on the HVAC systems.
ACCESSORIES

HYDRAULIC VERSIONS
Double pump version B2/M2/A2 (Low/Medium/High pump pressure)

Pump 1

Pump 2

One of the 2 pumps is a back up pump!


Please see the installation sketches showing mandatory hydraulic acceccories to be installed
on the HVAC systems.
ACCESSORIES

HYDRAULIC VERSIONS
Single pump version + WATER TANK SB/SM/SA (Low/Medium/High pump
pressure)

Pump

Water tank

Please see the installation sketches showing mandatory hydraulic acceccories to be installed
on the HVAC systems.
ACCESSORIES

HYDRAULIC VERSIONS
Double pump version + WATER TANK XB/XM/XA (Low/Medium/High pump
pressure)

Pump 1

Pump 2

Water tank

Please see the installation sketches showing mandatory hydraulic acceccories to be installed
on the HVAC systems.
ACCESSORIES

ACOUSTIC VERSIONS LN and SL - the composition may


change according to the product family!

STEP condensing
control Sound compressor
jackets

Continuous fan speed


modulation Sound proofing box
for compressors
ACCESSORIES

ACOUSTIC VERSIONS LN and SL - the composition may


change according to the product family!

Sound proofing compressors box Sound compressor jackets

Used on CWC SL version

Panels covered with sound


proof insulation
ACCESSORIES

CONTROL PANEL
THERMOSTAT for Control Panel Electric heaters

PHASE PHAILURE RELAY


(optional)

Automatic circuit breakers


Compressors for compressors (optional)
Automatic
contactors circuit Automatic
breakers circuit
for com- breakers Compressors
pressors for fans contactors
(optional) (optional)

Water pumps motor overload


protection
Compressors
contactors
Water pumps contactors

Control panel
electric heater
(optional)
Automatic water
Control panel
pump
electric heater
commutation (optional)
(optional)
ACCESSORIES

MOUNTED ACCESSORIES
ACCESSORIES

MOUNTED ACCESSORIES Soft-starter


Reduces compressor inrush current

At start-up (a few seconds), the electric motors have a very high inrush current
LRA (3-10 times the nominal one) → Stress for motors and electric cables

Soluzione Soft-starter: avviamento graduale del motore, con aumento graduale di


tensione/corrente/velocità → 50% reduction → less stress for motors and
cables and less disturbances for the electrical network
ACCESSORIES

MOUNTED ACCESSORIES

Control panel electric heater with thermostat


To protect the electric components from low ambient temperatures
(down to -10°C)
→ reduction of risk of component deterioration over time due to low
temperatures
ACCESSORIES

MOUNTED ACCESSORIES
Phase failure relay
To protect unit from power supply instability issues
There may be disturbances in the electrical network of the system (voltage
drops, phase imbalance, phase failure, etc.) → Risk of damage to electrical
components (electronics, compressors, etc.)
The protection relay intervenes by interrupting the power supply and
protecting the components → reduction of the risk of damage to electrical
components (electronics, compressors, etc.)
ACCESSORIES

MOUNTED ACCESSORIES
Numbered wires STANDARD
To faciltate maintenance operations on the electrical panel

Easy maintanaince!
ACCESSORIES

MOUNTED ACCESSORIES
Automatic circuit breakers compared to standard fuses they ensure better
protection for fans and compressors motor in case of motor overload

Automatic circuit breakers


for compressors
Automatic
circuit Automatic
breakers circuit
for com- breakers
pressors for fans
ACCESSORIES

MOUNTED ACCESSORIES
Automatic circuit breakers

Trip curve of the The automatic


circuit breaker circuit breaker
protects both
Overload against circuits
and overloads.
time

Trip curve of the


fuse
The automatic
circuit breaker can
be reset while the
fuse cannot, it
Regular must be replaced,
operating in case of
area of the
intervention.
electric Short circuit
motor

current
ACCESSORIES

MOUNTED ACCESSORIES
Electrical power supply without neutral
Electrical power supply standard (with NEUTRO)
Phase 1
Three-phase electric
Phase 2
Double isolation loads (compressors, fans,
ecc) Phase 3
network transformer

Single-phase electric
loads (electronical, ecc) NEUTRAL

Electrical power supply with PTIONAL (without NEUTRAL)


Phase 1
Three-phase electric
Phase 2
loads (compressors, fans,
ecc) Phase 3

Single-phase electric One less electric


loads (electronical, ecc) cable
ACCESSORIES

MOUNTED ACCESSORIES
Power factor correction cosphi 0,91
To reduce the reactive power and therefore the electrical current

Power that requires the engine


"Negative" effect
of electric motors

Condensers
"Positive" effect of
condensers

Lower electric current:


• Lower cost of electricity
• Less energy dissipation in cables (greater efficiency)
ACCESSORIES

MOUNTED ACCESSORIES
Optional BMS –Building Management System

➢ Serial card with BACnet™ Protocol ➢ Gateway Modbus Lontalk


TCP/IP or MS/TP.

Serial card RS485 for Modbus is always provided as STANDARD for all the
units equipped with Dixell iPRO devices.
ACCESSORIES

MOUNTED ACCESSORIES
ELECTRONIC EXPANSION VALVE
The use of an electronic expansion valves allows a precise control of the
refrigerant flow so that the system can operate with low condensation
temperatures.

❑Maximization of heat exchange to the


evaporator;

❑Minimization of response times to load


variations;

❑Optimization of superheating regulation;

❑Highest energy efficiency.


ACCESSORIES

MOUNTED ACCESSORIES
External heat source management for space heating
….and for DHW !!!

The AUXILIARY HEATING function


Already available on request! enables the use of an additional heat
COMING SOON on TEOS! source, activated via digital output.

The expansion enables an auxiliary heat


source to function as a replacement or What is it??
support for the heat pump when the
outdoor temperature drops below a
certain value.
ACCESSORIES

External heat source management for space heating


….and for DHW !!!

✓ Boilers
✓ Stoves Which sources?
✓ Electric heaters

✓ … And all auxiliary external


sources supporting the heat
pump for space heating and
Domestic hot water!

Solar thermal
ACCESSORIES

External heat source management for space heating


….and for DHW !!!
The activation logic of this heat source can be of two types:

if the external temperature drops below a set limit,


this source is activated as an integration for compressors.
Integration + If the temperature drops further, the compressors are
Replacement disabled and the heating will become in charge only of
the secondary heat source (when the efficiency of the
heat pump drops drastically due to the low external
temperatures).

if the external temperature drops below a set limit,


this source is activated as a replacement for
Replacement compressors that will be disabled (when the efficiency of
the heat pump drops drastically due to the low external
temperatures).
ACCESSORIES

MOUNTED ACCESSORIES
3-WAY VALVE KIT FOR DHW PRODUCTION (optional)
KIT Composed by VALVE supplied loose + 3 way valve supply and management

DHW through a three-way


diverter valve to be
installed by the customer
on the air conditioning
branch.

It includes also the Anti-legionella function!


ACCESSORIES

MOUNTED ACCESSORIES
3-WAY VALVE KIT FOR DHW PRODUCTION (optional)
It is possible to set the heat pump Priority can be set on
regulation on 2 different set point DHW production
values, one for heating and one for the
production of hot water for sanitary use.

When the temperature


in the tank reaches the
set point, the valve
deviates the hot water
to the heating system.

It includes also the Anti-legionella function!


ACCESSORIES

MOUNTED ACCESSORIES

WHAT IS IT?
The ANTI-LEGIONELLA function enables the
use of the use of an additional heat source,
activated via digital output.
Instant kill
90% kill in 2 minutes
90% kill in 2 minutes
WHICH SOURCES?
For example, it is possible to manage the Optimum growth
electric heater of the DHW tank temperature

Bacteria will survive


HOW? in a dormant state
Through a free voltage contact, the external
resource is enabled to raise the temperature beyond
the limits allowed for the heat pump (> 55 ° C) for
the period necessary for the elimination of
legionella.
ACCESSORIES

MOUNTED ACCESSORIES
Gas gauges
High and Low pressure gauge to quickly check
the pressure of the refrigerant circuit.
ACCESSORIES

MOUNTED ACCESSORIES
embpapst - EC axial fan - HyBlade

✓ Electronically Commutated Motor fans (EC fans)


Reduced power input and sound levels at partial load
For low ambient operation in cooling mode.

✓ EC fans with increased head pressure 100 Pa


In case external fans head pressure is needed
(suitable also for low ambient operation in cooling mode)

Diffusers Axitop for axial fans (optional)


Optimize the air flow. →
Reduces fan noise.
Combined with the EC fan, it also increases the fan
efficiency.
ACCESSORIES

MOUNTED ACCESSORIES
Condensing control with variable fans speed modulation
Also known as "Condensation / evaporation control via variable fan speed modulation"
standard on many units.

✓ It changes the speed and the


absorbed current of the fans
through the phase modulation

✓ It is often included in the Super


low noise versions or in the low
outdoor temperatures kit .

Why to select it?


• For operation at low external temperatures in chiller mode or at
high external temperatures in heat pump mode.
• To increase efficiency at partial loads
ACCESSORIES

MOUNTED ACCESSORIES
EC fans vs Standard fans with RGF

EC fans: + efficiency, + cost


Electrical
standard fans with RGF: - efficiency; - cost
power
100%
standard fans +
RGF

50%
EC fans

12%

50%
10% 30% 100% Speed
Air flow
ACCESSORIES

MOUNTED ACCESSORIES
SPECIAL COILS TREATMENTS
- For Cu-Al coils (heat pumps)

Proximity to the sea


Pollution
- For micro-channels coils (chiller) is available the E-coated anti-corrosion
treatment
ACCESSORIES

MOUNTED ACCESSORIES
Hydrophile coating of aluminum fins:

The HYDROPHIL surface treatment of the fins allows to improve the heat
exchange performance

✓High energy efficiency with low


outdoor temperature
✓Better condensate drainage
capacity
✓Reduced risk of accidental icing of
the coils
✓Improved defrost efficiency
ACCESSORIES

MOUNTED ACCESSORIES
Pre-painted condensing coils fins

Aluminium fins are first treated


with Epoxy coating, the coil is
assembled thereafter.
ACCESSORIES

MOUNTED ACCESSORIES
Aluminum Epoxy coated condensing coils
(with epoxy pre-painted aluminum fins
and external epoxy coating of the coil)

External
Epoxy
Pre-painted fins
coating
ACCESSORIES

MOUNTED ACCESSORIES
Additional coils treatment (for aggressive environments, marine areas or
industrial polluted environments):

✓ Aluminum + Blygold condensing coils


✓ Copper/copper condensing coils (picture below)
ACCESSORIES

MOUNTED ACCESSORIES
Protection grilles

Condensing coil protection grilles Full protection grilles


ACCESSORIES

MOUNTED ACCESSORIES Sea container kit


Mandatory for see container shipment

LIFTING BRACKETS

SIDE BUMPER

BRACKET TO PULL OUT


SIDE BUMPER THE UNIT FROM THE
CONTAINER

BELTS TO LOCK THE UNIT

SKIDS FOR THE BASE FRAME OF THE UNIT


ACCESSORIES

LOOSE ACCESSORIES
Installation at customer care
ACCESSORIES

LOOSE ACCESSORIES
2 OR 3 WAY VALVE FOR CONDENSING CONTROL
(optional)
When the unit works in chiller mode, the 2 or 3 way valves adjust the flow
rate in order to offer the correct condensing temperature.

❑Highest energy efficiency

❑Greater reliability of the system

2 WAYS: opens / closes automatically by changing the flow rate to the source
exchanger. The water temperature on the exchanger does not change.

3 WAYS: recirculates the water by modulating the source exchanger automatically:


constant flow and constant water temperature.
More efficient than 2-WAY and More expensive.
ACCESSORIES

LOOSE ACCESSORIES
FREE-COOLING function for CWC
Accessory that allows, through the management of an external dry-cooler, to take
advantage of the free-cooling mode with consequent energy savings
dry-cooler «Esterno»

OPERATING MODES:
100% chiller
100% free-cooling (compressors off)

ENERGY SAVING AND CO2 REDUCTION


ACCESSORIES

LOOSE ACCESSORIES
FREE-COOLING function for CWC
On-board components:
• 1 electronic I/O expansion:
• Enabling signal for 3-way valve
• Enabling signal for water pumps
CWC
• Enabling signal for dry-cooler
• 2 water temperature sensors

Loose components:
• 3-ways valve

Plant components of the customer:


• Dry-cooler
• Water piping

*Glycol needed (on user&source side)


**Not compatible with integrated hydraulic kit. Water pumps only in «external» version (in
development phase)
ACCESSORIES

LOOSE ACCESSORIES
Victaulic KIT includes:
✓ Victaulic Adapter (from Threaded to Victaulic)
✓ Clamp and pipe

The installation is at customer care


ACCESSORIES

LOOSE ACCESSORIES
Flow switch Automatic water filling Water gauges

The installation is at customer care


ACCESSORIES

LOOSE ACCESSORIES

Threaded water strainer Victaulic water strainer

The installation is at customer care


ACCESSORIES

LOOSE ACCESSORIES
Remote control display

Further info about


the Remote
control display
functionalities are
available in the
User guide
ACCESSORIES

LOOSE ACCESSORIES
Rubber anti-vibration mounts Spring anti-vibration mounts

They reduce the dynamic stresses on the structure on which the unit is
mounted → less vibrations, less noise

Spring anti-vibration mounts: + vibration damping; + cost


Rubber anti-vibration mounts: - vibration damping; - cost
The installation is at customer care