You are on page 1of 1

2019-04-30

XTERN FOOT DROP ORTHOTIC


- SIZING CHART -
turbomedorthotics.com
FOOT DROP?
GET YOUR LIFE BACK!
KIT SIZE SELECTION
US SHOE SIZE PRODUCT: PRODUCT: PRODUCT: PRODUCT:
100100-SA-L 100100-SA-M 100100-SA-S 100100-SA-P

MEN WOMEN KIDS


LARGE MEDIUM SMALL PEDIATRIC
16 X
15.5 X
15 X
14.5 X
14 X
13.5 X
13 X
12.5 X SELECT BEST SIZE FROM XTERN FOOT DROP BRACE - DORSIFLEXION ASSIST
PATIENT FOOT WIDTH
12 X The XTERN is the only Dynamic AFO totally affixed outside the
11.5 X shoe to maximize comfort, prevent skin breakdown and rubbing
11 X injuries to the foot. Its flexibility helps keep maximal ankle range
of motion and calf muscle strength.
10.5 11.5 X X
10 11 X The XTERN AFO acts as a Preloaded Exo-Skeleton Spring, and
9.5 10.5 X transfers dorsiflexion forces directly to footwear to keep foot
9 10 X at 90deg.
8.5 9.5 X
8 9 8Y X X The Flexible Spring can unwind under force
applied or weight bearing (C) to permit
7.5 8.5 7.5 Y X X
controlled plantar flexion.
7 8 7Y X
6.5 7.5 6.5 Y X The AFO gives back dorsiflexion as Spring
6 7 6Y X rewinds (D).
5.5 6.5 5.5 Y X
Spring Force Allow Easy
5 6 5Y X Assist Dorsiflexion Plantar Flexion
4.5 5.5 4.5 Y X C
4 5 4Y X D
3.5 4.5 3.5 Y X
3 4 3Y X X
2.5 3.5 2.5 Y X X
2Y X
1.5 Y X
XTERN AFO Suggested* HCPCS Code L1951 & L2820
1Y X
L1951 : Ankle foot orthosis, spiral, (institute of rehabilitative medicine type),
13 C X plastic or other material, prefabricated, includes fitting and adjustment
12.5 C X
12 C X L2820: Addition to lower extremity orthosis, soft interface for molded plastic,
below knee section
11 C X
*Suggested L Codes are provided as a reference only. It is the responsibility of the practitioner
10.5 C X to confirm this information.
10 C X
9.5 C X
Y : YOUTH SHOE SIZE (6-10 YEARS) C : CHILDREN SHOE SIZE (1-5 YEARS) CLINICAL INDICATIONS CLINICAL LIMITATIONS
 Drop Foot & Dorsiflexion Weakness  Inappropriate Footwear
 Peroneal Nerve Injury  Gross Fixed Deformities
 Charcot Marie Tooth (CMT) of Foot and Ankle
 Stroke (CVA)  Severe Spasticity
 Multiple Sclerosis (MS)  Quadriceps weakness
 Cerebral Palsy (CP)  Severe Proximal weakness
 Guillain-Barre Syndrome (GBS)  Crouch gait
 Motor Neuropathy
 Motor Neurone Disease (MND)
WE RECOMMEND THE QUALIFIED HEALTH CARE PROVIDER

EASILY TRANSFERABLE!
ASSESS THE PATIENT WITH AN AT-X ASSESSMENT TOOL.

TurboMed Orthotics Inc.


240 Sydney (Suite 101)
St-Augustin-de-Desmaures, QC

FDA Registration No: 3011816892 FDA Medical Device Listing no: D246429
CE Class I Medical Device - Germany HMV-Nr. 23.03.02.6024 (Hilfsmittel) 1 888 778-8726
Health Canada Medical Device Establ. Lic. No 6354 Class I
info@turbomedorthotics.com
U.S. Patent No.8529484 – Canadian Patent 2692534 – Europe Patent EP 2533734 - International Patent Pending www.facebook.com/groups/TurbomedFootDropClub/