Cementation of Crowns

003 1562R594R

Indication 1
Primers for Pretreatment
Zirconia
Clean and dry the tooth surface in the usual manner. As necessary, trial fit the crown using the Try-in Paste, wash and remove. Tooth, Intra-oral Enamel Implant
composite resins (Adhesion bridges Metals Metal oxides abutments Silica-based Glass-fiber Composite

1 Blast with alumina 2 Apply CERAMIC PRIMER 3 Apply Tooth Primer, 4 Dispense cement and or Metals or veneers) (Zirconia) and Frames ceramics posts resins Flow Chart Sheet
or Uncut enamel
powder, then ultrasonic PLUS and dry. leave for 20 sec., and place the crown.
clean and dry. thoroughly dry with mild air.

20 sec.
Indications for Use Indication 1
1) Cementation of crowns, bridges, inlays and onlays
OR 2) Cementation of veneers
*1 3) Cementation of adhesion bridges and splints*
crowns inlays / onlays bridges
4) Cementation of prosthetic restorations on implant
abutments and frames* Indication 2 Indication 4 Indication 5

5) Cementation of posts and cores


5 Remove the excess
A. Tack-curing B. Using a small brush 6 Maintain isolation for 6) Amalgam bonding*
cement using either
① Light-cure for 3 to 5 sec. ① Remove with a small brush.
3 minutes, or light-cure* Apply, Wait for 20 sec., * Please refer to the IFU for 3), 4) and 6) of indications. veneers implant posts
method. for translucent crowns. Apply & Dry
3∼5sec.
& thoroughly dry
Opaque shade is Table1: Working time Table2: Curing time for type of light source
used for method B.
with mild air.
Working time after initial
2 min. Type of light source (Light intensity) Curing time
dispensing (23°C/ 73°F)
OR High-intensity BLUE LED* Twice for
Sandblast, rinse & dry Working time after insertion
② Remove with a dental explorer. ② Light-cure margins. Refer to table 2. 60 sec. (More than 1500 mW/cm 2) 3 to 5 sec.
Conditioning *2 Apply hydrofluoric acid, rinse & dry *1 of the paste into the cavity (37°C/ 99°F)

Apply K-ETCHANT Syringe, leave for 5 sec, rinse & dry BLUE LED* (800-1400 mW/cm2) 10 sec.
*1 If your laboratory already treated with a hydrofluoric acid, cleaning and activating with K-ETCHANT
We mention the abbreviated product name in this sheet. Halogen lamp (More than 400 mW/cm2) 10 sec.
* Refer to table 2. The opaque shade is
Syringe just before applying CERAMIC PRIMER PLUS is recommended, as necessary. CLEARFIL CERAMIC PRIMER PLUS The effective wavelength range of each dental curing unit must be 400 - 515 nm.
self-cure only.
*2 For a detailed procedure, please check the Instructions for Use. CERAMIC PRIMER PLUS * Peak of emission spectrum: 450 - 480 nm.
08/ 2015
Indication 1 Cementation of Crowns Indication 2 Cementation of Veneers Indication 5 Cementation of Posts
Silica-Based Ceramics (e.g. Lithium Disilicate) Silica-Based Ceramics (e.g. Porcelain)
Clean and dry the tooth surface in the usual manner. As necessary, trial fit the crown using the Try-in Paste, wash and remove. Clean and dry the tooth surface in the usual manner. After preparation of the cavity and trial fit of the post.

1 Apply hydrofluoric acid 2 Apply CERAMIC PRIMER 3 Apply Tooth Primer, 4 Dispense cement and 1 As necessary, trial fit the 2 ①Apply hydrofluoric acid or 3 ①Apply K-ETCHANT Syringe ②Apply Tooth Primer, leave 1 Treatment of the post 2 Apply Tooth Primer, 3 Remove any excess liquid
or K-ETCHANT Syringe, PLUS and dry. leave for 20 sec., and place the crown. veneer using Try-in Paste, K-ETCHANT Syringe, rinse and dry. to the enamel, leave for for 20 sec., and thoroughly leave for 20 sec. with a paper point, and
rinse and dry. thoroughly dry with mild air. wash and remove. ②Apply CERAMIC PRIMER 10sec., rinse and dry. dry with mild air. Glass-fiber and ceramic posts Metal posts thoroughly dry with mild air.
5sec. PLUS and dry. ①Apply 5sec. ① Blast with alumina powder,
20 sec. 10 sec. 20 sec. K-ETCHANT then ultrasonic clean and dry. 20 sec.
Syringe, leave
Hydrofluoric ②Apply CERAMIC PRIMER PLUS
for 5 sec., rinse
acid and dry.
OR and dry.
OR
②Apply CERAMIC
Hydrofluoric K-ETCHANT
5sec. PRIMER PLUS
acid Syringe
and dry.
K-ETCHANT
Syringe

5 Remove the excess


A. Tack-curing B. Using a small brush 6 Maintain isolation for 4 Dispense cement and 5 Remove the excess cement using either method. 6 Maintain isolation for 4 Apply the mixed paste over 5 Place the post quickly, 6 Spread the excess cement 7 Place the core buildup
cement using either 3 minutes, or light-cure* place the veneer. Opaque shade is used for method B. 3 minutes, or light-cure* the post or the entire tooth by slightly vibrating it. over the coronal base and composite resin*.
① Light-cure for 3 to 5 sec. ① Remove with a small brush.
method. for translucent crowns. for translucent veneers. surface*. post head, then light-cure*.
A. Tack-curing OR B. Using a small brush
Opaque shade is 3∼5sec. ① Light-cure for 3 to 5 sec. ① Remove with a small brush.
used for method B.
3∼5 sec.
OR
② Remove with a dental explorer. ② Light-cure margins. Refer to table 2.
② Remove with a dental explorer. ② Light-cure margins. Refer to table 2.

* Refer to table 2. The opaque shade is * Refer to table 2. The opaque shade is * Refer to table 1 for Working time * Refer to table 2. For the opaque * Prepare the abutment tooth 6 minutes
self-cure only. self-cure only. shade, set for 3 minutes after after seating the dental post.
placement of the post.