Axpert MAX Communication Protocol for HV7.2kW & LV5kW
1
Axpert MAX Communication Protocol
2
Axpert MAX Communication Protocol
3
Axpert MAX Communication Protocol
1 Communication format
1.1 RS232
Baud rate Start bit Data bit Parity bit Stop bit
2400 1 8 N 1
2 Inquiry Command
2.3 QSID<cr>: The device serial number inquiry (the length is more than 14)
Computer: QSID<CRC><cr>
Device: (NNXXXXXXXXXXXXXXXXXXXX <CRC><cr>
1
Axpert MAX Communication Protocol
NN: Serial number valid length, X: Serial number, invalid part is filled as ‘0’, total X is 20.
2
Axpert MAX Communication Protocol
3
Axpert MAX Communication Protocol
4
Axpert MAX Communication Protocol
5
Axpert MAX Communication Protocol
6
Axpert MAX Communication Protocol
7
Axpert MAX Communication Protocol
8
Axpert MAX Communication Protocol
9
Axpert MAX Communication Protocol
Example:
Computer: QMOD<CRC><cr>
DEVICE: (L<CRC><cr>
Means: the current DEVICE mode is Grid mode.
10
Axpert MAX Communication Protocol
otherwise warning
a17 Eeprom fault Warning
a18 Inverter Over Current Fault
a19 Inverter Soft Fail Fault
a20 Self Test Fail Fault
a21 OP DC Voltage Over Fault
a22 Bat Open Warning
a23 Current Sensor Fail Fault
a24 Reserved
a25 Reserved
a26 Reserved
a27 Reserved
a28 Reserved
a29 Reserved
a30 Reserved
a31 Battery weak
a32 Reserved
a33 Reserved
a34 Reserved
a35 Battery equalization Warning
11
Axpert MAX Communication Protocol
The unit is V.
F is an Integer
Charging float
F FF.F ranging from 0 to 9. Default 54.0
voltage
The unit is V.
G is an Integer
G GG.G Charging bulk voltage ranging from 0 to 9. Default 56.4
The unit is V.
H is an Integer
Battery default
H HH.H ranging from 0 to 9. Default 46.0 for HV model
re-charge voltage
The units is V.
I is an Integer ranging
I II Max charging current from 0 to 9. Default 60 for HV model
The units is A.
AC input voltage J is an Integer ranging
J J Default 0 for Appliances range
range from 0 to 1. No unit
K is an Integer
K K Output source priority ranging from 0 to 1. No Default 0 for utility first
unit
L is an Integer
Charger source
L L ranging from 1 to 3. No Default 2 for solar and utility
priority
unit
M is an Integer
M M Battery type ranging from 0 to 1. No Default 0 for AGM
unit
N is an Integer
Enable/disable silence
N N ranging from 0 to 1. No Default 0 for enable buzzer
buzzer or open buzzer
unit
O is an Integer Default 0 for disable power
Enable/Disable power
O O ranging from 0 to 1. No saving
saving
unit
P is an Integer Default 0 for disable overload
Enable/Disable
P P ranging from 0 to 1. No restart
overload restart
unit
Enable/Disable over Q is an Integer Default 0 for disable over
Q Q temperature restart ranging from 0 to 1. No temperature restart
unit
Enable/Disable LCD R is an Integer Default 1 for enable LCD
R R backlight on ranging from 0 to 1. No backlight on
unit
Enable/Disable alarm S is an Integer Default 1 for enable alarm on
S S on when primary ranging from 0 to 1. No when primary source interrupt
source interrupt unit
12
Axpert MAX Communication Protocol
2.16 QMUCHGCR<cr>: Enquiry selectable value about max utility charging current
Computer: QMUCHGCR<CRC><cr>
Device: (AAA BBB CCC DDD……<CRC><cr>
More value can be added, make sure there is a space character between every value.
2.17 QOPPT<cr>: The device output source priority time order inquiry
Computer: QOPPT<CRC><cr>
Device: (M M M M M M M M M M M M M M M M M M M M M M M M N O O
O<CRC><cr>
M: 24 hour correspond to the output source priority (0: Utility first, 1: Solar first, 2: SBU)
N: device output source priority
O: selection of output source priority order
13
Axpert MAX Communication Protocol
Example:
Computer: QOPPT<CRC><cr>
Device: (0 0 0 0 0 2 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2<CRC><cr>
Means: the device output source priority time order is SBU from 5 to 6, and output source priority
is Utility first.
2.18 QCHPT<cr>: The device charger source priority time order inquiry
Computer: QCHPT<CRC><cr>
Device: (M M M M M M M M M M M M M M M M M M M M M M M M N O O
O<CRC><cr>
M: 24 hour correspond to the charger source priority (1: Solar first, 2: Solar + Utility, 3: Only solar
charging permitted)
N: device charger source priority
O: selection of o charger source priority order
Example:
Computer: QCHPT<CRC><cr>
Device: (1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 1 0<CRC><cr>
Means: the device charger source priority time order is solar + utility from 20 to 23, and charger
source priority is Solar first.
2.19 QT<cr>: Time inquiry
Computer: QT<cr>
Device: (YYYYMMDDHHMMSS<cr>
Example:
Computer: QT<cr>
Device: (20180101111120<cr>
Means: The time is 2018/01/01 11:11:20.
Data Description Notes
( Start byte
YYYYMMDD Date Y, M and D are an Integer number 0 to 9.
HHMMSS Time H, M and S are an Integer number 0 to 9.
14
Axpert MAX Communication Protocol
Minute.
D DDD equalization period D is an Integer number 0 to 9. The unit is day.
E EEE equalization max E is an Integer number from 0 to 9. The unit is
current A.
F FFF reserved reserved
G GG.GG equalization voltage G is an Integer ranging from 0 to 9. The units
is V.
H HHH reserved reserved
I III equalization over time I is an Integer ranging from 0 to 9. The unit is
Minute.
j J equalization active J is an Integer ranging from 0 to 1.
status
k KKKK equalization elapse time K is an Integer ranging from 0 to 9. The units
is Hour.
15
Axpert MAX Communication Protocol
16
Axpert MAX Communication Protocol
17
Axpert MAX Communication Protocol
MKS-2000-24 Plus
MKS-3000-24 Plus
VP-5000
VM-5000
VM-3000 Plus
MKS-1000-48
MKS-2000-48
MKS-3000-48 15A
MKS-2000-48 Plus
MKS-3000-48 Plus
5 AC input voltage range 0: Appliance range
6 Output source priority 0: Utility first
7 Battery re-charge voltage 11.5/23/46 for 12/24/48V unit.
8 Charger source priority 0: Utility first
9 Battery type 0: AGM
10 Enable/disable buzzer alarm 1: Enable buzzer alarm
11 Enable/Disable power saving 0: Disable power saving
12 Enable/Disable overload restart 0: Disable overload restart
13 Enable/Disable over temperature restart 0: Disable over temperature restart
14 Enable/Disable LCD backlight on 1: Enable LCD backlight on
15 Enable/Disable alarm on when primary 1: Enable beep on when primary source
source interrupt interrupt
16 Enable/Disable overload bypass when 0: Disable overload bypass
overload happened in battery mode
17 Enable/Disable LCD display escape to 1: Enable LCD display escape to default
default page after 1min timeout page
18 Output mode 0: single output(for 4K/5K)
19 float charging voltage 13.5/27.6/55.2 for 12/24/48V unit.
20 Bulk charging voltage 14.1/28.8/57.6 for 12/24/48V unit.
21 Battery cut-off voltage 10.5/22/44 for 12/24/48V unit.
22 Battery re-discharge voltage 13.5/27/54 for 12/24/48V unit.
For LIYUAN MKS Plus LV:
Battery re-discharge capacity 90% for LIYUAN MKS Plus LV
Note: The correct default value can be gain by QDI command.
18
Axpert MAX Communication Protocol
19
Axpert MAX Communication Protocol
21
Axpert MAX Communication Protocol
22
Axpert MAX Communication Protocol
Detail:
abc:
Charger Discharger
111 Enabled charger Enabled discharger
Enabled charger, depends on Prog16 setting if
AC source valid, charge 2A from AC, even if Disabled discharger and shut down unit
011 prog. 16 is “only solar”. If prog. 16 is any other completely when insufficient PV or Grid is
setting, ignore and let charging from AC source present.
continue normally.
Enabled charger, depends on Prog16 setting if
AC source valid, charge 2A from AC, even if
Disabled discharger but keep unit stay at standby
101 prog. 16 is “only solar”. If prog. 16 is any other
mode.
setting, ignore and let charging from AC source
continue normally.
110 Disabled charger Enabled discharger
Disabled discharger and shut down unit
010 Disabled charger
completely when no PV or Grid is present.
Disabled discharger but keep unit stay at standby
100 Disabled charger
mode.
001 N/A N/A
Cleaned the enable/disable charger flags and Cleaned the enable/disable discharger flags and
000
return to previous charger status. return to previous discharger status.
23
Axpert MAX Communication Protocol
4 Appendix