You are on page 1of 2

MD200 AC Drive

Open Loop General Purpose & Economic

Wide operating voltage


Single Phase 220Vac
Features & Functions 170 to 264Vac
0.4 ~2.2kW
Open loop V/f control
Staring torque of 150% at 3Hz
Modbus or CANLink comms Internal EMC Filter
Automatic torque boost
Slip compensation
Complies with EN61800-3
Simplified parameter for easy Category C2
nd
2 Environment
start up
2-Independent S-Ramps
Flexible programmable I/O
Operation in high
connection ambient temperature
45⁰Cavg
Variable DC-injection braking
Comprehensive trip
diagnostics
Enhanced reliability with
Output frequency 500Hz conformal coating,
protection against
In-Built Dynamic braking unit humidity and pollution
dust

Flexible Installation Mode


Onboard Comms
Modbus / CANLink

PRG
ENTER
PRG
ENTER
PRG ENTER
MF.K
MF.K

MF.K
RUN STOP/RES
RUN STOP/RES
STOP/RES
RUN STOP/RES

Side-by-Side Wall Mounted DIN Rail Mounted

Forward, Always Progressing


General Specifications
Voltage class Single Phase 220Vac Three Phase 400Vac ( Under development )
Drive Model MD200S0.4B MD200S0.75B MD200S1.5B MD200S2.2B MD200T0.75B MD200T1.5B MD200T2.2B MD200T3.7B
Height [H1] : 180 mm [H1] : 180 mm
Dimension Width [W] : 75 mm [W] : 75 mm
Depth [D] : 145 mm [D] : 145 mm
Single Phase 200Vac to 240Vac, -15% to +10% Three Phase 380 to 480V, -15% to +10%
Rated Input Voltage
Drive Input

(170Vac to 264Vac) (323Vac to 528Vac)

Rated Input Current, [A] 6.5 11.0 18.0 27.0 3.4 5.0 5.5 11

Rated input frequency 50/60 Hz, 5% (47.5 to 63Hz)

[kW] 0.4 0.75 1.5 2.2 0.75 1.5 2.2 3.7


Applicable Motor
[HP] 0.5 1 2 3 1 2 3 5

Output Current ,[A]*2 2.6 4.6 8 11 3.4 4.8 5.5 9.1


Drive Output

Power Capacity, [kVA] 1.7 3.0 4.8 7.1 1.7 3.0 4.8 7.1

Overload Capacity 150% for 60 Sec & 180% for 3 Sec

Three Phase 200Vac to 240Vac Three Phase 380Vac to 480Vac


Max. output voltage
(Proportional to input voltage) (Proportional to input voltage)

Max. output frequency 500 Hz

Recommended
80 80 100 100 150 250 300 400
Resistor
Braking

Power, [W]
Recommended
 200  150  100  70  300  220  200  130
Resistance, []

Enclosure IP 20
*2Carrier switching frequency 6kHz at rated output current
** All units are fan cooled

General Connection Diagram Dimension


External Braking Resistor (To be supplied by Optional)
2

BR
L L1 U

External Line
Mains RFI Filter Reactor
Supply (Option) (Option)
V
IM
N L2 W

Supply Ground
MD200S
+24Vdc
RJ45
Hot pluggable
Remote Keypad
RUN Forward [ F4-00 =1 ] DI1

Forward Jog [ F4-01 = 4 ] DI2

0 100%
Fault Reset [ F4-02 = 9 ] DI3 (0 to10Vdc )
AO

Multi-Reference 1 [ F4-03 = 12 ] DI4 GND

TC
COM Drive Healthy
250Vac 10mA to 3A
TA 30Vdc 10mA to 3A
10Vdc
AI Input RS485 Termination
VR [0 to10Vdc ] or Voltage or Current input mode Mode Select Resistor Select
AI Selectable via DIP switch
1~5kΩ [0~20mA] Termination
(Default voltage input mode) ON ON
Current Resistor
GND DIP SW Connected
ON Mode
1 2 3 1 2 3 RT (120Ω)

RS485+ 485+ 1 2 3 Voltage ON ON Unterminated


Mode RT (120Ω)
Default Setting (Default) 1 2 3 1 2 3 (Default)
RS485- 485-

GND

For more information, please contact our local offices.

Hong Kong SAR Italy - Milan India:


Inova Automation Italy Srl Inova Automation Pvt, Ltd. Turkey - Istanbul
Inova Automation Co., Limited Inova Automation Tü rkiye
Tel : (39) 02 2682 2318 Head Office Chennai
International Export Office Tel : (90) 216 706 1789
info@inova-automation.com Tel : (91) 44 4380 0201
Tel : (852) 2751 6080 info.turkey@inova-automation.com
Ahmedabad Tel : (91) 79 4003 4274
Fax : (852) 2751 6933
Mumbai Tel : (91) 90 0496 0595
info@inova-automation.com
New Dehli Tel: (91) 99 9092 8961
www.inova-automation.com
info.inovaindia@inova-automation.com
© Inova Automation Co.,Ltd 2016. The information contained in the brochure is for guidance only. V1.0

You might also like