You are on page 1of 12

K219

Drywall and Floor Systems 2005-02

K219 Knauf Free-spanning


Fireboard Ceilings A1
K219 - Knauf Free-spanning Fireboard Ceiling A1 - metal substructure CW/UW

New
■ Fire resistance F90 from below and from above with up to 3.5 m span width
■ Maximum spacing of ceiling profiles increased to 625 mm
Knauf Free-spanning Fireboard Ceiling A1 K219
Fire protection from below / from below and from above (Plenum)
Subceilings with sole fire rating
From below Fire resistance Knauf System
For fire exposure from below, the fire class
rating of the "subceiling solely" covers for fire exposure Cladding Sub- Insulation layer
the constructions above, such as structure (required for
ceiling or roof constructions.
Type/ Min.- Max. axial fire protection)
(e. g. trapezoid sheet metal roofs)
from from building thickness spacing
From above below above
Fire exposure from the ceiling plenum. material ceiling profiles
The ceiling or roof construction above class
b Min. Min.
has to be of the same fire rating.

Proof
thickness density
mm mm mm kg/m³

K219 Knauf Free-spanning Fireboard Ceiling A1

Fireboard without insulation


A1
F90 Z-PA-III
2x 20 625 or 1
4.290 min. B2

K219 Knauf Free-spanning Fireboard Ceiling A1

Fireboard 20
A1 + Mineral wool S
F90 F90 625 1
Z-PA-III 20 60 50
4.290 upper cover

Adjacent structural components have to be of fire resistance class F90 min.


If the free spanning ceiling is connected (anchored) to a lightweight partition (F90), an additional, 20 mm thick Fireboard cladding layer is required for
the partition on the side of the supporting connection.

Mineral wool insulation layer acc. to DIN EN 13162, section 3.1.1

Building material class A Proof


S Melting point • 1000 °C
acc. to DIN 4102-17 1 ABP P-3085/3824
2
Knauf Free-spanning Fireboard Ceiling A1 K219
Anchoring
Anchoring of the supporting UW perimeter runners
Anchoring on Anchor Maximum spacing of anchors
F90 F90
solely from below solely from below
and from above
Metal stud partitions
(Anchoring in metal studs 2x Knauf Multi-purpose Screw FN 4.3x35 625 mm 312,5 mm
or Flex Profile)

Reinforced concrete walls Knauf Ceiling Steel Dowel 250 mm


300 mm
Knauf Nailable Plug L 8/80 -

Substantial masonry without Knauf Nailable Plug L 8/80 300 mm -


cavities or light concrete Anchor that is suitable for the respective substrate 1) 2)
(density • 1000 kg/m³) and approved in terms of fire protection (F90) 300 mm 300 mm

Load bearing capacity (min.): 1) shear: 0.35 kN; 2) shear: 0.35 kN; extraction: 0.5 kN

Connections to partitions Screw connection of Knauf CW double profiles


F90 solely from below
” 750 mm
Knauf UW runner, anchored
on metal studs of partition
with Knauf Multi-purpose
Screws 2x FN 4.3x65
Connect Knauf CW double
profiles on each top flange
with UW runner by riveting,
30 mm crimping or screwing with Screw connect Knauf CW profiles at web with Metal Screws
Metal Screws LB 3.5x9.5 mm. LB 3.5x9.5 mm at a spacing of ” 750 mm
Knauf CW double profile
additional 2x FN 4.3x65 Fastening of covering strips
Fireboard Knauf UW runner
Fireboard covering strips 12.5 mm, 120 mm wide
F90 solely from below and from above
” 250 mm ” 250 mm ” 250 mm
2x FN 4.3x65 Knauf UW runner, anchored
additional on metal studs of partition
Fireboard and into Flex Profile
with Knauf Multi-purpose
Screws 2x FN 4.3x65

Flex
Profile
30 mm
Fasten Fireboard covering strips using Drywall Screws
TN 3.5x25 mm at a spacing of ” 250 mm alternating
100 mm on double profiles

Knauf UW runner Knauf CW double profile with Fastening of Knauf Boards with Drywall Screws TN
Flex Profile Fireboard covering strips
Cladding on metal profiles Maximum
Connect Knauf CW double profile with UW runner on each flange (penetration • 10 mm) spacing of
Thickness in mm metal gauge ” 0.7 mm fasteners

F90 solely from below


2x 20 Fireboard 1st layer TN 3.5x35 500 mm
1 2
2nd layer TN 3.5x55 170 mm

F90 solely from below and from above


or 20 Fireboard TN 3.5x45 170 mm
including covering strip using including covering strip and + 12.5 covering strip
Drywall Screws TN 3.5x25 cladding using
Drywall Screws TN 3.5x45 Fasten Knauf Boards alternating on CW double profiles
3
Knauf Free-spanning Fireboard Ceiling A1 K219
Fire resistance F90 ● solely from below

b C

D D B B

Max. room width 4 m

Room width in m
Knauf CW double profile Max. spacing of Fireboard Max. room width Knauf UW runner
as ceiling profile ceiling profiles perimeter support

Metal gauge 0.6 mm b Min. thickness in m Metal gauge 0.6 mm


2x CW 50 2 UW 50
2x CW 75 2.75 UW 75
2x CW 100 625 mm 2x 20 mm 3.25 UW 100
2x CW 125 3.5 UW 125
2x CW 150 4 UW 150
Higher room widths on request.
Details, scale 1:5

Connect Knauf CW double profile Knauf CW double profile


with UW runner as ceiling profile
Knauf CW double profiles Knauf UW runner as Metal Screw
as ceiling profiles perimeter support LB 3.5x9.5
• 90 mm
• 90 mm

Drywall Screw Knauf Fireboard 2x 20 mm Drywall Screw TN 3.5x35 Fibre Glass Joint Tape
TN 3.5x55 Fireboard Filler
b ” 625 mm ” 625 mm b

K219vu-B3 Front edge joint (B-B) K219vu-C3 Long edge joint (C-C)

Connect free-spanning Knauf CW double profile on each top flange with Knauf UW runner
Note by riveting, crimping or screwing with Metal Screws LB 3.5x9.5 (see page 3).
4
Knauf Free-spanning Fireboard Ceiling A1 K219
Fire resistance F90 ● solely from below
Details, scale 1:5

Knauf UW runner, anchored on


metal studs of partition with Knauf
Multi-purpose Screws 2x FN 4.3x65 Anchor that is suitable for the respective substrate
(see page 3) and approved in terms of fire protection (see page 3)

Knauf CW double profile Edge Trim, if necessary


as ceiling profile Fireboard Filler
F90 partition Additional Fireboard 20 mm
+ Fireboard 20 mm ” 20 mm • 20 mm
Max. room width

K219vu-D3 Supporting connection to partition (D-D) K219vu-D4 Supporting connection to wall


with shadow gap (D-D)

Knauf CW profile
Knauf UW runner as perimeter support Fireboard strips
(anchoring acc. to page 3) Drywall Screw TN

Knauf Fireboard 2x 20 mm Knauf CW profile Knauf UW runner


Fireboard Filler + Trenn-Fix 65 as perimeter support
F90 partition
” 20 mm • 20 mm
” 625 mm b

K219vu-A3 Constructional
partition (A-A)
connection to K219vu-A4 Constructional connection to wall
with shadow gap (A-A)

Fireboard strips 20 mm, glued with Ceiling bulkhead F90


Knauf Fireboard Filler on one side
Knauf Suspended
Ceiling without
requirements for
fire protection

Knauf Fireboard 2x20 mm a a •a Fireboard strip


e.g. joint profile
• 25 • 25 • 25
ca. 100 mm ca. 100 mm a ” 20 mm

K219vu-C4 Movement joint (C-C) K219vu-A5 Section of ceiling transition (A-A)


Ceiling bulkhead acc. to Techn. Data Sheet D16

5
Knauf Free-spanning Fireboard Ceiling A1 K219
Fire resistance F90 ● solely from below and from above

A
C

D D B B

Max. room width 3.5 m

Max. room width in m


Knauf CW double profile Max. spacing of Fireboard Max. room width Knauf UW runner
as ceiling profile ceiling profiles perimeter support

Metal gauge 0.6 mm


b Min. thickness in m Metal gauge 0.6 mm
2x CW 75 2.75 UW 100
2x CW 100 625 mm 20 mm 3.25 UW 125
2x CW 125 3.5 UW 150
Higher room widths on request.
Details, scale 1:5

20 mm Fireboard applied without Fireboard covering strip


fastening, tightly jointed
120 mm
Knauf CW double profiles Fireboard covering Knauf CW double profile 10 10 Knauf UW runner as
as ceiling profiles strip 12.5 mm as ceiling profile 100 perimeter support
• 140 mm

• 140 mm

Fireboard covering strip 12.5 mm Mineral wool Drywall Screw


S
Fireboard Filler + (see page 2) TN 3.5x45
Fibre Glass Joint Tape
Knauf Fireboard 20 mm b ” 625 mm ” 625 mm b

K219vuvo-B3 Front edge joint (B-B) K219vuvo-C3 Long edge joint (C-C)

Note Connect free-spanning Knauf CW double profile on each flange with Knauf UW runner (see pagee 3).

6
Knauf Free-spanning Fireboard Ceiling A1 K219
Fire resistance F90 ● solely from below and from above
Details, scale 1:5

Knauf UW runner, anchored on metal studs


of partition or into Flex Profile with Knauf Acnhor that is suitable for the respective substrate
Multi-purpose Screws 2x FN 4.3x65 (see page 3) and approved in terms of fire protection (see page 3)

Additional Fireboard 20 mm Drywall Screw TN 3.5x45


F90 partition 100 mm Flex Profile Knauf Fireboard 20 mm
+ Fireboard 20 mm ” 20 mm •5
Max. room width

K219vuvo-D3 Supporting connection to partition (D-D) K219vuvo-D4 Supporting connection to wall


with shadow gap (D-D)

Fireboard covering strip


60 mm Knauf UW runner as perimeter support
(anchoring acc. to page 3) Fireboard strip
Knauf Fireboard 20 mm Drywall Screw TN

Knauf CW profile Edge Trim, if necessary


Fireboard Filler + Trenn-Fix 65 Fireboard Filler
F90 partition
” 20 mm •5
” 625 mm b

K219vuvo-A3 Constructional
partition (A-A)
connection to K219vuvo-A4 Constructional connection to
wall with shadow gap (A-A)

Fireboard strips 20 mm, glued with


Knauf Fireboard Filler on one side Ceiling bulkhead F90

Knauf Suspended Ceiling


F30 from below

Fireboard strips 20 mm, glued with Knauf Fireboard 20 mm Fireboard strip


Knauf Fireboard Filler on one side e.g. joint profile • 10

• 25 a • 25 •a
ca. 100 mm ca. 100 mm a ” 20 mm

K219vuvo-C4 Movement joint (C-C) K219vuvo-A5 Section of ceiling transition (A-A)


Ceiling bulkhead acc. to
Technical Data Sheet D16
7
Knauf Free-spanning Fireboard Ceiling A1 K219
Fire resistance F90 ● solely from below
Lighting, Access Panel Details, scale 1:5
Fire protection encasement for built-ins Access panel

625 mm 625 mm
” 400 mm 420 mm
Clearance

SO1 SO1
SO3 SO3

Clearance
600 mm
SO2 SO4

SO2 SO4
2x 20 mm Fireboard encasement Fold Knauf UW Profile and connect
Fold Knauf UW Profile and connect with double profile
with additional CW Profile Knauf CW double profile
Additional continuous Knauf CW Profile
Knauf CW double profile
Scheme drawing, top view Scheme drawing, top view
625 mm
” 400 mm Note Alutop Access Panel on request
40 ” 625 mm 625 mm

steel staples Slide UW Profile onto


acc. to DIN 18182 double profile and connect

Built-in lighting
10 kg max.

Additional continuous Screw fixing of access panel Access panel


Knauf CW Profile into UW Profile (LB 3.5x9.5) 420 mm
Clearance
K219vu-SO1 Lateral section of built-in lighting K219vu-SO3 Lateral section of access panel
Encasement made of
2x Knauf Fireboard 20 mm Fold Knauf UW Profile and
Knauf UW Profile connect with double profile

Built-in lighting
10 kg max.,
fastening acc. to
providers spec.
Additional continuous Access panel
Knauf CW Profile 600 mm
Clearance

K219vu-SO2 Longitudinal section K219vu-SO4 Longitudinal section


of built-in lighting of access panel
8
Knauf Free-spanning Fireboard Ceiling A1 K219
Fire resistance F90 ● solely from below and from above
Lighting, Access Panel Details, scale 1:5
Fire protection encasement for built-ins Access panel
625 mm 625 mm
” 400 mm 420 mm
Clearance

SO3 SO3
SO1 SO1

Clearance
600 mm
SO2 SO4

SO2 SO4
Additional continuous Knauf CW Profile Circumferential 12.5 mm Fireboard strip
with 20 mm Fireboard strip on the Fold Knauf UW Profile and slide on
rear side double profile
Knauf CW double profile with covering strip Knauf CW double profile with covering strip
Scheme drawing, top view Scheme drawing, top view

Note Alutop Access Panel on request


625 mm
” 400 mm ” 625 mm 625 mm
20 mm
20 mm Knauf Fireboard, Mineral wool
applied on entire ceiling area (see page 2) Knauf UW Profile

Built-in lighting
10 kg max.,
fastening acc. to
providers spec.

Additional continuous Knauf Drywall Screw TN 3.5x45 Access panel


CW Profile with 20 mm Screw fixing of access panel
Fireboard strip on the rear side into UW Profile (LB 3.5x9.5) 420 mm
Clearance
K219vuvo-SO1 Lateral section of built-in lighting K219vuvo-SO3 Lateral section of access panel
Fireboard covering Circumferential 12.5 mm
12.5 mm Knauf Fireboard applied ca. 100 mm Fireboard strip (applied after
loose at the lighting area installation of access panel)

Built-in lighting
10 kg max.

Additional continuous Knauf Knauf UW Profile Access panel


CW Profile with 20 mm 600 mm
Fireboard strip on the rear side Clearance

K219vuvo-SO2 Longitudinal section


of built-in lighting
Longitudinal section
K219vuvo-SO4 of access panel
9
Knauf Free-spanning Fireboard Ceiling A1 K219
Consumption of Material of selected examples
Consumption of material per m² ceiling without allowance for loss and waste. (Amounts refer to ceiling area of: 2.5 m x 10 m = 25 m²)

Description Unit Amount as average value


Fire resistance F90 Fire resistance F90
solely from below solely from below and from above

Knauf Fireboard Knauf Fireboard


italic = not provided by Knauf 2x 20 mm 20 mm
Perimeter Support
or
UW Profile 50x40x0.6; (4.0 m long) -
or
UW Profile 75x40x0.6; (4.0 m long) -
or
UW Profile 100x40x0.6; (4.0 m long) m 0.8
or
UW Profile 125x40x0.6; (custom.) 0.8
UW Profile 150x40x0.6; (custom.)
Anchoring of UW Profiles as perimeter support:
Knauf Multi-purpose Screw FN 4.3 x 65 mm 2.7 5.3
or pcs
or Knauf Ceiling Steel Dowel; (package 100 pcs) 2.6
or Knauf Nailable Plug "L" 8/80; (pakage 50 pcs) 2.6 -
suitable, approved anchor 2.6

or
CW Profile 50x50x0.6; (up to 5.0 m long) -
CW Profile 75x50x0.6; (up tp 6.0 m long)
or
or
CW Profile 100x50x0.6; (up tp 6.0 m long) m 0.2 0.2
CW Profile 125x50x0.6; (custom.)
or
CW Profile 150x50x0.6; (custom.) -
Anchoring of CW Profiles as perimeter connection:
or Knauf Multi-purpose Screw FN 4.3 x 35 mm pcs
or Knauf Ceiling Steel Dowel; (package 100 pcs) as required as required
or Knauf Nailable Plug "L" 8/80; (package 50 pcs)
suitable, approved anchor
Substructure
Knauf CW double profiles as ceiling profile:
or
CW Profile 50x50x0.6; (up to 5.0 m long) -
CW Profile 75x50x0.6; (up tp 6.0 m long)
or
or
CW Profile 100x50x0.6; (up tp 6.0 m long) m 3.0 3.0
CW Profile 125x50x0.6; (custom.)
or
CW Profile 150x50x0.6; (custom.) -
Knauf CW double profiles, screw connected at web
Knauf Metal Screw LB 3.5 x 9.5 mm pcs 2.4 2.4
Connection of double profiles with supporting UW runners:
or e.g. blind metal rivets 2.6 -
pcs -
e.g. TN 3.5 x 25 mm 2.6
Insulation (observe fire protection requirements; see page 2) m² as required 1.0

Cladding
Knauf Fireboard; 20 mm m² 2.0 1.0
Knauf Drywall Screws; (fastening of Fireboard)
TN 3.5 x 35 mm 10 -
TN 3.5 x 45 mm pcs - 18
TN 3.5 x 55 mm 18 -
Fireboard covering strip, 120 mm wide:
Knauf Fireboard; 12.5 mm m² - 0.4
Knauf Drywall Screws; (fastening of covering strips)
TN 3.5 x 25 mm pcs - 15
additional layer (covering):
Knauf Fireboard; 20 mm m² - 1.0
additional layer (upgrading of partition):
Knauf Fireboard; 20 mm m² as required as required
Flex Profile - 0.8
Filling
Knauf Fireboard Filler; (5 kg/20kg bag) kg 0.12 0.06
Knauf Fibre Glass Joint Tape; (25 m roll) m 1.1 1.1
Trenn-Fix 65; (50 m roll) m 1.0 1.0
Edge Trim 23/13; (2.75 m long) m as required as required
10
Knauf Free-spanning Fireboard Ceiling A1 K219
Tender Specifications
Item Description No. of units Unit price Total price

........ Subceiling DIN 18168-1 as free-spanning ceiling,


installation height in m ....................,
ceiling span in m ............................. .
Fire resistance class according to DIN 4102-2 F90,
for the ceiling solely resistant to fire from below to protect the basic ceiling and the plenum, */
for the ceiling solely resistant to fire from the plenum to protect the room below the ceiling, */
for the ceiling solely resistant to fire from the plenum and from below
to protect the room below the ceiling, the basic ceiling and the plenum *.
Anchored on reinforced concrete/ masonry/ metal stud partition/
wood frame partition/ ........................... *.
Upgrading of existent metal stud partition with 1 layer Knauf Fireboard 20mm,*
Substructure made of galvanized metal channels,
ceiling channels as double profiles CW 50/ 75/ 100/ 125/ 150 *
with covering strips made of Knauf Fireboard, thickness = 12.5 mm, width = 120 mm,*
Cladding made of Knauf Fireboard, thickness 20/ 2 x 20 * mm.
additional layer of Knauf Fireboard, thickness 20 mm, applied on top of the ceiling profiles,*
Insulation layer made of mineral wool acc. to DIN EN 13162 *,
thickness in mm ..............., min. density in kg/ m³ ..................., *
building material class A/ B1/ B2 *, melting point min. 1000 °C. *
Product/ System: Knauf Free-spanning Fireboard Ceiling A1 K219 .......... m² .......... € .......... €

........ Connection with joint,


fire resistance F90, for free-spanning ceiling,
circumferential, installation acc. to drawing no. ............... . ........... m .......... € .......... €

........ Expansion joint,


fire resistance F90, as upgrade for free-spanning ceiling,
installation acc. to drawing no. ............... . ........... m .......... € .......... €

........ Movement joint,


fire resistance F90,
as upgrade for free-spanning ceiling,
installation acc. to drawing no. ............... . ........... m .......... € .......... €

........ Ceiling bulkhead, height in m .................,


fire resistance F90,
as upgrade for free-spanning ceiling,
installation acc. to drawing no. ............... . ........... m .......... € .......... €

Cut out, as upgrade for free-spanning ceiling,


........ diameter in mm .................../ dimensions in mm ....................... *. .......... pcs .......... € .......... €

........ Opening, incl. reinforcement of substructure,


for the installation of access panels/ ................................... *,
as upgrade for free-spanning ceiling, dimensions in mm ...........................,
installation acc. to drawing no. ............... . ........... pcs .......... € .......... €

........ Fire protection encasement for built-in lighting,


fire resistance F90,
dimensions in mm ...........................,
installation acc. to drawing no. ............... . ........... pcs .......... € .......... €

Access panel,
........ fire resistance F90,
with aluminium frame, dimensions in mm .........................,
filling made of Knauf boards, thickness in mm ................. ,
for free-spanning ceiling.
Product: Knauf Access Panel D171 ........... pcs .......... € .......... €

........ Subsequent filling of joints of ceiling built-ins. ........... m .......... € .......... €

* Cancel not applicable items Sub-total ................ €

11
K219 Knauf Free-spanning Fireboard Ceiling A1
Construction, Application, Filling / Coats and linings

Construction
Knauf Free-Spanning Fireboard Ceilings A1 are Joints (extensions) of free-spanning profiles are built-ins like lighting fixtures, with control joints that
solely anchored on the walls at perimeter. Knauf NOT allowed. Movement joints of the main struc- allow for movement, e. g. shadow gaps.
Fireboard (gypsum fleece boards of building ma- ture have to be taken over into the construction of Knauf profiles are delivered galvanized. The cor-
terial class A1) are fastened to a metal substruc- the Knauf Fireboard Ceilings. Use control joints in rosion protective coating is sufficient for indoor
ture made of Knauf CW double profiles. The appli- the case of ceiling areas over approx. 15 m length, application, including bathrooms and kitchens in
cation of additional loads like lighting fixtures with or for narrow ceiling spaces caused by a break of private housing. For other areas, e. g. under in-
max. 100 N (10 kg) per double profile (50 N per m² a wall. Separate connections of Knauf Fireboard to fluence of outdoor air, additional corrosion pro-
ceiling area) with suitable anchors directly to the components made of materials other than gypsum, tection is necessary (see DIN 18168-1 table 2).
metal substructure is permissible. especially columns, or thermally highly stressed

Application
If the free-spanning ceiling is connected (an- with Metal Screws LB 3.5 x 9,5 mm at a spacing at the board edges in order to avoid buckling.
chored) to a lightweight partition (F90), an addi- of 750 mm max. Firmly push Fireboard to substructure and fas-
tional, 20 mm thick Fireboard cladding layer is re- ■ Support length of CW double profiles in UW pe- ten with Drywall Screws TN at a spacing of 170
quired for the partition on the side of the support- rimeter runners has to be at least 30 mm. Con- mm alternating on the CW double profiles.
ing connection. nect both top flanges of CW double with the UW ■ In case of double layer cladding, the spacing of
Substructure runner by riveting /crimping or screwing with LB the screws can be increased for the first layer to
■ Supporting perimeter connection made of UW 3.5 x 9.5, if no covering strip is required. 500 mm if the second layer is applied immedi-
Profiles. Anchoring acc. to table on page 3. In ■ Only in case of fire protection solely from below ately afterwards (on the same day).
case of connection to a lightweight partition AND from above: Fasten Knauf Fireboard strips, ■ Only in case of fire protection solely from below
(F90) and fire protection from below AND from 12.5 mm thick, 120 mm wide, as covering strips AND from above: Apply covering layer of Knauf
above, apply Flex Profile underneath the addi- on top and bottom of the CW double profiles al- Fireboard 20 mm without fastening, tightly joint-
tional Fireboard layer on the partition for the an- ternating with Drywall Screws TN 3.5 x 25 mm ed.
choring of the supporting perimeter runner. at a spacing of 250 mm max. Connection of CW ■ Fastening of 20 mm thick Fireboard with Drywall
Spacing of anchors in this case: 312.5 mm double profiles with UW perimeter profiles acc. Screws TN 3.5 x 45 mm /
■ In case of sound protection requirements, seal to page 3. 2 x 20 mm with TN 3.5 x 45 mm + TN 3.5 x 55
up carefully with Acoustical Sealant according Cladding mm.
to DIN 4109, supplement 1, chapter 5.2; porous ■ Apply Knauf Fireboard parallely to CW double ■ Apply Knauf Trenn-Fix 65 on connections to ad-
sealant strips like Sealing Tape are usually not profiles. Place long edge joints on profiles. jacent components and fill connection joints with
suitable in this case. ■ Stagger front edge joints by 400 mm min. Fireboard Filler.
■ Connect CW Profiles as double profiles at web ■ Start fastening Fireboards in the board centre or

Filling / Coats and linings


Filling material Coats and linings in paint, polymer resin paint, PUR lacquer, or
Hand filling with Knauf Fireboard Filler and Knauf Use a primer on Knauf Fireboard before coating epoxy-based lacquer, according to intended use
Fibre Glass Joint Tape. or painting. Ensure that the primer and the coat or or as required.
Application paint are compatible. The following coats can be ■ Alkaline coats such as lime, water glass paints
In case of double layer cladding, fill joints of first used on Knauf Fireboard: and silicate-based paints are not suitable for
layer, fill and smooth joints of top layer. Fill all visi- ■ Wallpaper: paper, textile and synthetic wallpa- gypsum board surfaces.
ble screw heads. Recommendation: Fill front edge pers. Use only adhesives made of cellulose ac- Silicate-based emulsion paints may be used af-
joints of visible layers with Fibre Glass Joint Tape cording to „Code of Practice no. 16 “Technische ter referring to the manufacturer’s recommen-
as well. Richtlinien für Tapezier- und Klebearbeiten“, dations and following the stipulated guidelines
Frankfurt/Main 2002, released by Bundesauss- closely.
Application temperature/climate chuss Farbe und Sachwertschutz.
Filling of joints should only take place after the Use Knauf Spezialgrund to prime the entire sur-
After applying paper or glass fleece wallpaper
boards have been allowed to rest in the given hu- face of filled Knauf Fireboards to control suction
ensure adequate ventilation for fast drying.
midity and temperature zones, and no more longi- and for optical harmonisation of the surface. Knauf
■ Plasters: Knauf Structured Plasters, e .g. resin
tudinal changes can be expected, i. e. expansion Spezialgrund is a system component for the cre-
palster, Finishing Plaster, entire surface skim-
or contraction. ation of surfaces with higher quality requirements
ming with Knauf Fireboard Filler, mineral plas-
Joints should be filled at a minimum temperature acc. to Code of Practice no. 2 „Verspachtelung von
ters. After application of resin plaster ensure ad-
of +10 °C (50 °F). Gipsplatten - Oberflächengüten“ of the IGG.
equate ventilation for fast drying.
In case of mastic asphalt screed, fill joints after ■ Coats: Wash and abrasive resistant resin dis-
screed has been applied. persion paints, multicoloured (rainbow) emul-
sion, oil paint, matte-finish lacquer, alkyd res-

Knauf Direct Knauf Drywall and Floor Systems Am Bahnhof 7, 97346 Iphofen, Germany
Technical Advisory Service:
* A rate of 0.39 € per minute will be charged for calls from within the German landline network. Callers whose phone numbers are not registered in the address database
of Knauf Gips KG, i.e. private builders or non-patrons, will be charged a rate of 1.69 € per minute. Calls from mobile phones will be charged 1.48 € per minute.
Phone: +49 9001 31-1000 *
** 0.14 €/Min.
Fax: +49 1805 31-4000 **
All technical changes reserved. Only the current printed instructions are valid. Our warranty is expressly limited to our products in flawless condition. All application quantities and delivery amounts
are based on empirical data that are not easily transferable to other deviating areas. The stated information represents current state-of-the-art Knauf technology. The entire state of approved en-
gineering rules, appropriate standards, guidelines, and rules of craftsmanship are not included herewith. These and all application instructions have to be adhered to separately by the installer.
All rights reserved. All amendments, reprints and photocopies, including those of excerpts, require the express permission of Knauf Gips KG, Am Bahnhof 7, 97346 Iphofen, Germany. Delivery
www.knauf.de via professional building material distributors only, in accordance with our current business, delivery and payment terms.

The constructional and structural properties, and characteristic building physics of Knauf systems can solely be
K219/engl./D/02.05/FB/D
ensured with the exclusive use of Knauf system components, or other products expressly recommended by Knauf.