You are on page 1of 1

Network Control Unit

DESCRIPTION

NCU or “Network Control Unit” is a device that gathers information on the status of a set of TCUs “Tracker Control Unit” and can configure their working parameters
(send them to specific positions such as stow position or cleaning mode or make them work in manual mode).
The NCU is also in constant communication with RSU “Remote Sensor Unit”. When an alarm state detected by the sensors occurs, the RSU identifies it and sends
the information to one or more NCU that modify the position of their TCUs’ set accordingly.

Certified quality

Remote operability
MAIN FEATURES

Site alarm position managegment

Field string cleaning position management

SCADA monitoring

Configurable software

Built-in differential, magnetothermic and varistor protection


CONSTRUCTIVE FEATURES

EQUIPMENT USE CLASS: Outdoor. UV protection enclosure.

MATERIAL: Polyester enclosure

IP/NEMA: IP 66

DIMENSIONS: All in one assembly piece. Standard 500x400x200 mm / 2.5Kg

FIXING CONFIGURATION: 4 female metallic inserts

RH: 65 ± 25% - Non-condensing

ALTITUDE: ‹2000 m standard

STORAGE TEMP.: [-40, 85] ºC

OPERATING TEMP.: [-20, 60] ºC


NEUTRAL
ELECTRICAL FEATURES

POWER SUPPLY

NOMPOWEINAL INPUT FREQUENCY: [50-60] Hz PHASE


GROUND
VARISTOR

VARISTOR
CIRCUIT

NOMINAL VOLTAGE INPUT: [100 - 240] Vac


RCCB

MAX CURRENT INPUT: 0.8 @ 115 Vac / 0.60 @ 230 Vac


BATTERY CHARGER
POWER

BATTERY 12 V BATTERY 12 V

CPU-CONTROL SUNTRACK 12H

GATEWAY

ANTENNA
TCP

Each NCU must be connected by an Ethernet cable and RJ45 connector to its internal switch
OTHERS

Each NCU is provided with 3IP addresses

Required unninterrupted power supply [100-241] Vac / [50,60] Hz

Provided without support structure unless requested

* The characteristics, information and images shown are for information purposes only, they do not have contractual value and they can differ slightly from final results.