Reliable backwater protection

Backwater protection for interior installation


Backwater protection for exterior installation

Protection from backwater


Things you need to know

Product Information Which Staufix ® do you need ?


Backwater damage can be extremely expensive - prevention is very Check your country´s EN 13564 backwater valve requirements for
cheap. For this reason make sure that all below ground areas with open what type of valve is certified for your situation. EN 13564 classifies
drainage fixtures are always protected by a KESSEL backwater valve. backwater valves from Type 0 to Type 5. KESSEL offers the complete
range of Type 0-5 valves.
For inline wastewater pipes
How it works
Type 0 KESSEL Staufix ® 71... Series
The Staufix ® is equipped with free hanging vertical backwater flaps. Type 1 KESSEL Staufix ® 72...
These flaps ensure that a building´s wastewater flows freely through and Eurofix-Clausio ®
the valve while simultaneously preventing any backwater from backing Type 2 KESSEL Staufix ® 73...
up into the building. and SWA
Type 3 KESSEL Staufix ® FKA, Pumpfix ® F

KESSEL stands for quality For floor drains


All KESSEL Backwater Valves Types 0 through 5 are manufactured Type 4 KESSEL Single flap floor drains
according to the EN norms and also have passed KESSEL´s strict in Type 5 KESSEL Pumpfix ® S, Drehfix ®,
house testing which requires backwater valves to perform above the Universal, Volatile liquid traps
EN norm requirements.

Protection for your entire basement

Protects against backwater flooding


from main sewer!

Protects against rodents


enterring through pipes!

R2
Ideal

concrete
for
waterproof

R3
for interior installation
Backwater protection

Backwater protection for exterior installation Backwater protection for interior installation
Pumpfix ® F backwater valve Ideal
wate for
for wastewater with or without sewage concrrproof
ete
according to EN 12056 for installation in a concrete slab/floor
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Pumpfix ® F backwater valve With black cover:


for wastewater with or without sewage, Ø 110 28 100S
Backwater protection for interior installation

made of polymer Ø 125 28 125S


For installation in a concrete slab/floor Ø 160 28 150S
for installation depth (D) from 370 - 550 mm
Installation kit with choice of cover plate With recessed cover
black cover for on-site tiling:
recessed cover Ø 110 28 100X
(Tiles can be laid on-site in the cover plate). Ø 125 28 125X
Backwater pumping station according to EN 13564
Ø 160 28 150X
Type 3 with pump (1kW/230V) and backwater valve,
use of pump when water backs up, suitable for waste-
water with or without sewage.
Control unit and alarm, Protection type IP 54, with inte-
grated self diagnosis system SDS and battery back-
up, pump is rated submersible, protection type IP 68
(3 m, 24h).
Cable length: 5 m (15 m available on request)
Weight approx. 25 kg.
D

Certification no. Z-53.2-388

Installation area 650 x 650 mm

Ø 110 L: 545 mm H: 262 mm - 470 mm


Ø 125 L: 555 mm H: 255 mm - 465 mm
Ø 160 L: 585 mm H: 238 mm - 450 mm Accessories: Page R 8

Pumpfix ® F backwater valve


for wastewater with or without sewage
according to EN 12056 for installation in an exposed wastewater pipe
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Pumpfix ® F backwater valve Ø 110 28 100


for wastewater with or without sewage, Ø 125 28 125
made of polymer
Ø 160 28 150
For installation in an exposed wastewater pipe
Backwater protection for exterior installation

Backwater pumping station according to EN 13564


Type 3 with pump (1kW/230V) and backwater valve,
use of pump when water backs up, suitable for waste-
water with or without sewage.
Control unit and alarm, Protection type IP 54, with inte-
grated self diagnosis system SDS and battery back-up,
pump is rated submersible, protection type IP 68 (3 m, 24h). Certification no. Z-53.2-388
With protective cover.
Cable length: 5 m (15 m available on request) Accessories: Page R 8
Weight approx. 20 kg.

Max. pumping capacity Q (m 3 /h) 0.0 3.0 5.0 6.5 7.8 9.0 10.0
Backwater height H (mWS) 9.0 8.0 7.0 6.0 5.0 4.0 3.0
10
Backwater height H (mWS)

Backwater pressure
9 from the drain
8
7
6
5
4 Pump pressure
3
2
Ø 110 L: 545 mm H: 343 mm 1
Ø 125 L: 555 mm H: 343 mm 0 1 2 3 4 5 6 7 8 9 10
Ø 160 L: 585 mm H: 343 mm Pumping capacity Q (m 3 / h)

R4
Staufix ® FKA backwater valve Ideal
wate for
for wastewater with or without sewage concrrproof
ete
according to EN 12056 for installation in a concrete slab/floor
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Staufix ® FKA backwater valve With black cover:


for wastewater with or without sewage, Ø 110 83 100S

Backwater protection for interior installation


made of polymer Ø 125 83 125S
For installation in a concrete slab/floor Ø 160 83 150S
for installation depth (D) from 370 - 550 mm
With telescopic extension section for continuous height With recessed cover
and level adjustment, surface water tight cover plate for on-site tiling:
Class A 15 made of polymer. Ø 110 83 100X
Backwater valve according to EN 13564 Type 3 Ø 125 83 125X
with two open flaps.
Control unit and alarm, Protection type IP 54, Ø 160 83 150X
with integrated self diagnosis system SDS and
battery back-up, motor is rated submersible,
Protection Type IP 68 (3 m, 24 h).
Installation kit with choice of cover plate
black cover
recessed cover
(Tiles can be laid on-site in the cover plate).
Cable length: 5 m
(15 m available on request)
D

Weight approx. 17 kg.

EN 13564 Type 3 F

Installation area 650 x 650 mm

Ø 110 L: 545 mm H: 262 mm - 470 mm


Ø 125 L: 555 mm H: 255 mm - 465 mm
Ø 160 L: 585 mm H: 238 mm - 450 mm Accessories/ Conversion kits: Page R 8

Staufix ® FKA backwater valve


for wastewater with or without sewage
according to EN 12056 for installation in an exposed wastewater pipe
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Staufix ® FKA backwater valve Ø 110 83 100


for wastewater with or without sewage Ø 125 83 125
made of polymer
Ø 160 83 150

Backwater protection for exterior installation


For installation in an exposed wastewater pipe
With protective cover.
Backwater valve according to EN 13564 Type 3
with two open flaps.
Control unit and alarm, Protection type IP 54,
with integrated self diagnosis system SDS and
battery back-up, motor is rated submersible,
Protection Type IP 68 (3 m, 24 h).
Cable length: 5 m
(15 m available on request)
Weight approx. 10 kg.

EN 13564 Type 3 F

Ø 110 L: 545 mm H: 343 mm


Ø 125 L: 555 mm H: 343 mm
Ø 160 L: 585 mm H: 343 mm Accessories/ Conversion kits: Page R 8

R5
Staufix ® SWA backwater valve Ideal
wate for
for wastewater with or without sewage concrrproof
ete
according to EN 12056 for installation in a concrete slab/floor
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Staufix ® SWA backwater valve With black cover:


made of polymer, Ø ..... Ø 110 73 100.10 S
Backwater protection for interior installation

For installation in a concrete slab/floor Ø 125 73 125.10 S


for installation depth (D) from 370 - 550 mm Ø 160 73 150.10 S
With telescopic extension section for continuous
height and level adjustment, surface water tight With recessed cover
cover plate Class A 15 made of polymer. for on-site tiling:
Backwater flap valve according to EN 13564 Ø 110 73 100.10 X
Type 2 with two self-closing flaps, one of which Ø 125 73 125.10 X
can be locked by hand as an emergency closure.
Ø 160 73 150.10 X
Installation kit with choice of cover plate
black cover
recessed cover
(Tiles can be laid on-site in the cover plate).
Weight approx. 15 kg.
D

EN 13564 Type 2

Installation area 650 x 650 mm

Ø 110 L: 545 mm H: 262 mm - 470 mm


Ø 125 L: 555 mm H: 255 mm - 465 mm
Ø 160 L: 585 mm H: 238 mm - 450 mm Accessories/ Conversion kits: Page R 8

Staufix ® SWA backwater valve


for wastewater with or without sewage
according to EN 12056 for installation in an exposed wastewater pipe
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Staufix ® SWA backwater valve Ø 110 73 100.10


made of polymer, Ø ..... Ø 125 73 125.10
For installation in an exposed wastewater pipe Ø 160 73 150.10
Backwater protection for exterior installation

With protective cover made of polymer. Backwater flap


valve according to EN 13564 Type 2 with two self-
closing flaps, one of which can be locked by hand as
an emergency closure.
Weight approx. 8 kg.

EN 13564 Type 2

Ø 110 L: 545 mm H: 343 mm


Ø 125 L: 555 mm H: 343 mm
Ø 160 L: 585 mm H: 343 mm Accessories/ Conversion kits: Page R 8

R6
Ideal
wate for
Controlfix clean out concrrproof
ete
according to EN 12056 for installation in a concrete slab/floor
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Controlfix clean out With black cover:


made of polymer, Ø ..... Ø 110 80 100S

Backwater protection for interior installation


For installation in a concrete slab/floor Ø 125 80 125S
for installation depth (D) from 370 - 550 mm Ø 160 80 150S
With telescopic extension section for continuous
height and level adjustment, surface water tight With recessed cover
cover plate Class A 15 made of polymer. for on-site tiling:
Installation kit with choice of cover plate Ø 110 80 100X
black cover Ø 125 80 125X
recessed cover
Ø 160 80 150X
(Tiles can be laid on-site in the cover plate).
Weight approx. 11 kg.
D

Installation area 650 x 650 mm

Ø 110 L: 545 mm H: 262 mm - 470 mm


Ø 125 L: 555 mm H: 255 mm - 465 mm
Ø 160 L: 585 mm H: 238 mm - 450 mm Accessories/ Conversion kits: Page R 8

Controlfix clean out


according to EN 12056 for installation in an exposed wastewater pipe
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Controlfix clean out Ø 110 80 100


made of polymer, Ø ..... Ø 125 80 125
For installation in an exposed Ø 160 80 150

Backwater protection for exterior installation


wastewater pipe
With protective cover.
Weight approx. 4 kg.

425 x 305
H


25

Ø 110 L: 545 mm H: 343 mm


Ø 125 L: 555 mm H: 343 mm
Ø 160 L: 585 mm H: 343 mm Accessories/ Conversion kits: Page R 8

R7
Accessories
Reliable backwater protection
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

Gasket set - 83 023


for installation in waterproof concrete consisting of:
Backwater protection for interior installation

Counter flange made of polymer, incl. screws,


elastomer waterproof web in NK/SBR Ø 800 mm
max. ground water level 3 m

쏗 480 Extension section - 83 070


150 made of polymer, H = 180 mm, incl. gasket

200
쏗 414

Potential-free contact - 80 072


Change-over contact 42 V / 0.5 A;
Additional circuit board with a potential-free contact
e.g. for connecting control unit to BMS (Building
Management System).

Audible alarm - 20 162


Electronic audible alarm (continuous tone)
with connection cable 20 m
Minimum current consumption 5 - 25 mA,
audible tone 4.7 KHz - 90 dB,
large voltage range 6 - 24 V DC;
Dimension Ø 31 x 15 mm.

Conversion kit Pumpfix ® F With 15 m cable length:


®
For conversion to Pumpfix F backwater valve. Ø 110 205-091
Ø 125 205-092
Ø 160 205-093

Conversion kit Staufix ® FKA With 15 m cable length:


®
For conversion to Staufix FKA backwater valve. Ø 110 80 083
Ø 125 80 082
Ø 160 80 082

Conversion kit Staufix ® SWA Ø 110 80 095


for wastewater Ø 125 80 095
Backwater protection for exterior installation

For conversion from Controlfix clean out to Ø 160 80 095


Staufix ® SWA backwater valve.

Easy conversion !
Conversion kits available for the Pumpfix ® F,
Staufix ® FKA and the Staufix ® SWA backwater
valves.

Conversion kit
Pumpfix ® F

Conversion kit
Staufix ® FKA

Conversion kit
Staufix ® SWA

R8
Staufix ® backwater valves
for wastewater with or without sewage
according to EN 12056
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Staufix ® twin flap backwater valve With 2 polymer flaps:


with emergency closure Ø 100 78 100

Backwater protection for interior installation


made of polymer, Ø ..... Ø 110 73 100
Twin flaps, self-closing, one of which can be locked Ø 125 73 125
by hand as an emergency closure.
Ø 160 73 150
Inlet/outlet for connection to PVC pipe
according to DIN 19534. Ø 200 73 200

Ø 100 L: 355 H: 180 + 25 A x B: 205 x 155 mm With 1 polymer flap and 1 stainless
Ø 110 L: 355 H: 180 + 25 A x B: 205 x 155 mm steel flap (Rodent protection):
AxB
Ø 125 L: 405 H: 240 + 40 A x B: 270 x 200 mm Ø 110 73 100R
Ø 160 L: 450 H: 240 + 40 A x B: 270 x 200 mm
Ø 200 L: 530 H: 278 + 50 A x B: 353 x 248 mm Ø 125 73 125R
H

Ø 160 73 150R

L
Installation area 650 x 300 mm EN 13564 Type 2

KESSEL Staufix ® single flap backwater With 1 polymer flap:


valve with emergency closure Ø 100 77 100
made of polymer, Ø ..... Ø 110 72 100
Flap self-closing and can be locked by hand Ø 125 72 125
as an emergency closure.
Ø 160 72 150
Inlet/outlet for connection to PVC pipe
Ø 200 72 200
according to DIN 19534.

Ø 100 L: 355 H: 180 + 25 A x B: 205 x 155 mm With 1 stainless steel flap


AxB Ø 110 L: 355 H: 180 + 25 A x B: 205 x 155 mm (Rodent protection):
Ø 125 L: 405 H: 240 + 40 A x B: 270 x 200 mm Ø 110 72 100R
Ø 160 L: 450 H: 240 + 40 A x B: 270 x 200 mm Ø 125 72 125R
Ø 200 L: 530 H: 278 + 50 A x B: 353 x 248 mm
H

Ø 160 72 150R

L
Installation area 650 x 300 mm EN 13564 Type 1

KESSEL Staufix ® single flap backwater Ø 100 76 100


valve Ø 110 71 100
made of polymer, Ø .....

Backwater protection for exterior installation


Ø 125 71 125
Flap self-closing. Ø 160 71 150
Inlet/outlet for connection to PVC pipe Ø 200 71 200
according to DIN 19534.

Ø 100 L: 355 H: 170 A x B: 205 x 155 mm


Ø 110 L: 355 H: 170 A x B: 205 x 155 mm
AxB Ø 125 L: 405 H: 230 A x B: 270 x 200 mm
Ø 160 L: 450 H: 230 A x B: 270 x 200 mm
Ø 200 L: 530 H: 278 A x B: 353 x 248 mm
H

L
Installation area 650 x 300 mm EN 13564 Type 0

R9
Staufix ® Ø 50 twin flap backwater valves / Staufix ® Siphon Ø 50
for wastewater without sewage
according to EN 12056
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Backwater twin flap valve Ø 50 73 050


Staufix ® Ø 50
Backwater protection for interior installation

for exposed wastewater pipes


made of polymer.
97x80 Twin flaps, self-closing, one of which can
be locked by hand as an emergency closure.
Inlet/outlet for connection to HT-pipe

쏗 50
80

according to DIN 19560.

196

EN 13564 Type 2

KESSEL Backwater twin flap valve Ø 50 73 051


Staufix ® Siphon Ø 50
for washing stand siphons
for wastewater,
97x80 made of polymer.
Twin flaps, self-closing, one of which can be
locked by hand as an emergency closure, incl.
쏗 50

wall attachment, inlet connection Ø 40 (R 1 1/2)


at pipe odour trap. Outlet Ø 50 for connection
to HT-pipe according to DIN 19560.
쏗 40
183

EN 13564 Type 5

KESSEL Backwater twin flap valve Ø 50 73 052


Staufix ® Siphon Ø 50
Model with pipe odour trap and washing
11/2 / 11/4 machine connection
for wastewater,
made of polymer.
97x80 Twin flaps, self-closing, one of which can
170 - 310

be locked by hand as an emergency closure,


incl. wall attachment, outlet Ø 50 for
connection to HT-pipe according to DIN 19560.
120

85

80 150
EN 13564 Type 5
Backwater protection for exterior installation

KESSEL Backwater twin flap valve Ø 50 73 053


Staufix ® Siphon Ø 50
Model with pipe odour trap and inlet funnel,
ideal for the emergency overflow of the
heating system for wastewater,
170 - 370

97x80
made of polymer.
Two flaps, self-closing, one of which can be
locked by hand as an emergency closure, incl.
120

85 wall attachment. Outlet Ø 50 for connection


to an HT-pipe according to DIN 19560.
80 150

EN 13564 Type 5

R 10
Backwater flap valves
for wastewater without sewage
according to DIN 12056
Outer diameter
Illustration and dimensioned drawing Article description Ø (mm) Art. #

KESSEL Multitube single flap Ø 260 71 250


backwater valve Ø 320 71 300

Backwater protection for interior installation


for wastewater Ø 400 71 400
made of polymer
Ø 510 71 500
Flap self-closing.
Dimensions in mm:
Ø 260 H: 485 L: 730 A x B: 680 x 440
Ø 320 H: 490 L: 840 A x B: 530 x 460
Ø 400 H: 605 L: 990 A x B: 655 x 590
Ø 510 H: 670 L: 1245 A x B: 960 x 710
with connection couplings*.
AxB Connection couplings allow connection to pipes
with the following outer diameters:
Ø 250: 250 - 275 mm Ø 500: 495 - 525 mm
Ø 300: 310 - 335 mm
Ø 400: 385 - 410 mm
H

EN 13564 Type 0
L

KESSEL Pipe flap valve Ø 110 79 100


for wastewater Ø 125 79 125
made of polymer
Ø 160 79 150
For use as a closure section.
Flap self-closing. Ø 200 79 200
Inlet/outlet for connection to PVC pipe
according to DIN 19534.

Ø 110 L: 120 mm
Ø 125 L: 136 mm
Ø 160 L: 142 mm
Ø 200 L: 170 mm

EN 13564 Type 0

KESSEL Pipe flap valve Ø 250 79 250


for wastewater Ø 315 79 300
made of polymer

Backwater protection for exterior installation


Ø 400 79 400
For use as a closure section. Ø 515 79 500
Flap self-closing.
Ø 600 79 600
Dimensions in mm: Other diameters available
Ø 250 H: 400 L: 220 B1: 345 B2: 280 on request
Ø 315 H: 450 L: 360 B1: 400 B2: 410
without connection coupling,
connection according to DIN 19534

B1 Ø 400 H: 540 L: 390 B1: 485 B2: 495


Ø 515 H: 680 L: 500 B1: 590 B2: 620
Ø 600 H: 770 L: 530 B1: 730 B2: 730
with connection coupling*.
H

B2

Connection couplings allow connection to pipes


with the following outer diameters:
Ø 300: 305 - 335 mm Ø 500: 495 - 525 mm
L Ø 400: 385 - 410 mm Ø 600: 590 - 620 mm

EN 13564 Type 0

*With connection couplings it is possible to connect pipes of different diameters.


Compensating rings are necessary where the difference in outer diameter is > 12 mm.
Rights reserved for technical changes

R 11
R 12
for exterior installation
Backwater protection

R 13
Backwater protection for exterior installation Backwater protection for interior installation
Backwater inspection chamber and Backwater inspection chamber GT Ø 1000
according to EN 752 for underground installation
Illustration and dimensioned drawing Article description

Standard cover on-site


KESSEL Backwater inspection chamber
and Backwater inspection chamber GT Ø 1000
Backwater protection for interior installation

Polyethylene construction,

Installation depths D for backwater chamber GT +175 mm


open channel flow Ø 160/200

Installation depths D from 1275 to 3540 mm possible


Accessories: Art. # 860 122 / 860 116 For underground installation
Inspection chamber height H = . . . . . mm in monolithic
structure, water-tight, resistant to aggressive wastewater,

from 50 to 550 mm
with integrated access steps, with telescopic height
adjustable protection cover made of polymer for use during
construction (can be used as a cover in green areas). Order
Inspection chamber including extension section/cover separately as accessories,
300 kg load class temporary con- see Chapter Inspection Chambers Page S 26.
struction debris cover With open channel x 3, two lateral inlets
Ø 160/200, backwater inlet connection Ø 160
with clean-out opening, outlet Ø 160/200.

Chamber height H 1 to H 5
Inlet/outlet with spigot end to the connection
for PVC-KG-pipe Ø 160/200 according to DIN 19534
and PE-HD-pipe Ø 160/200 according to DIN 19537.
Can be retrofitted with backwater flap valve
Type KESSEL-Pumpfix ® F, KESSEL-Staufix ® FKA
or KESSEL-Staufix ® SWA.
Note: Cable piping to be provided.
Total installation depth D: . . . . . mm
550 756
333
Certification no. Z-42.1-333

Channel types: Chamber Backwater chamber Chamber Backwater chamber GT Ordering Scheme, extension sections,
height Ø 160/200 Art. # height Ø 160/200 Art. # covers and gaskets see Page R 18
Flow direction
H1 1100 mm 881 004 H1 1275 mm 880 10 04
H2 1600 mm 881 504 H2 1775 mm 880 15 04
H3 2100 mm 882 004 H3 2275 mm 880 20 04
H4 2600 mm 882 504 H4 2775 mm 880 25 04
Extension section Extension section
H5 3100 mm 883 004 H5 3275 mm 880 30 04 with cover plate for BEGU-cover

Accessories
Article description Outer diameter
Illustration Ø (mm) Art. #

Conversion kit Pumpfix ® F With 15 m cable length:


Backwater protection for exterior installation

for wastewater with or without sewage Ø 160 205-093


For conversion to the backwater inspection
chamber with Pumpfix ® F backwater valve.

Conversion kit Staufix ® FKA With 15 m cable length:


for wastewater with or without sewage Ø 160 80 082
For conversion to the backwater inspection chamber
with Staufix ® FKA backwater valve.

Conversion kit Staufix ® SWA Ø 160 80 095


for wastewater with or without sewage
For conversion to the backwater inspection chamber
with Staufix ® SWA backwater valve.

Cable piping gasket set Ø 110 85 410


5
1 Pipe sealing gasket
2 KG-collar plug 3 Twin collar Ø 110
1 2
3 4 HT-collar plug 5 Cable connections
4 6 6 Retaining clip with screws

R 14
Backwater inspection chamber and Backwater inspection chamber GT Ø 1000
according to EN 752 for underground installation
Installation suggestion KESSEL - typical advantages

Variable extension section as accessory

Backwater protection for interior installation


inclinable
height adjustable

NEW The backwater inspection chamber is


now also available in the version GT
Re-enforced chamber handles up
to 2.5 meters of groundwater.

Additional lift protection


The backwater inspection
chamber GT is provided in
the lower region with an
additional lift-protection
ring (with contact surfaces
Underground backwater protection between building and main sewer. for spirit levels).

Conversion kits: Advanced safety


The safety access steps
in the backwater inspec-
tion chamber are
absolutely new GT. The
safety access steps in
Pumpfix ® F backwater valve corrosion-resistant PE-HD
for wastewater with or without sewage, in yellow signal colour
with 15 m cable prevents slipping and can
Art. # 205-093 be gripped for a safer hold
when negotiating the
chamber.
Safer entry and exit -
additional access steps
in the tapering area.
Staufix ® FKA backwater valve
for wastewater with or without sewage,
with 15 m cable

Backwater protection for exterior installation


Art. # 80 082

Three standard connection options


for cellar drains, roof gutters, drainage etc.

Staufix ® SWA backwater valve
for wastewater with or without sewage
Art. # 80 095


For the purpose of retrofitting a 햴


KESSEL backwater unit at a later date
a cable piping in KG Ø 110 is fitted at 햲 Cellar outlet 햴 Drainage above the
the time of installation. Cable pipe backwater level
햳 Clean-out opening
gasket Art.# 85 410 can be retrofitted 햵 Roof drainage
with backwater 햶 Outlet to drain
protection

R 15
Controlfix clean out Variable extension section:
in the Komfort-Inspection chamber System Ø 800 and Ø 1000 inclinable
height adjustable
according to EN 752 for underground installation Vehicle traffic proof

Illustration Article description

KESSEL Controlfix clean out


in the KESSEL-Komfort inspection chamber Ø...
Backwater protection for interior installation

Polyethylene construction
for wastewater with or without sewage,
for underground installation
Installation depth (D) from ..... mm to ..... mm
Inclusive integrated access steps (with Ø 1000), water-tight,
resistant to aggressive wastewater. Extension section
made of polymer for continuous height and level adjustment.
Optional cover plate class ..... in cast iron according
to EN 124, surface water tight, incl. cover removal tool.
Continuous pipe Ø .....
with cleaning pipe according to EN 13564.
Inlets with outer collar, outlet with spigot end for PVC-KG
pipe according to DIN 19534 and PE-HD pipe according
to DIN 19537.
Conversion center inlet pipe to bottom inlet pipe:
Ø 110: Installation depth D + 55 mm
Ø 125: Installation depth D + 62.5 mm
Ø 160: Installation depth D + 80 mm
Delivery:
Inspection chamber in components (bottom parts stackable)
for on-site assembly incl. assembly system.

Accessories: see Page R 18

Accessories
Illustration Article description Outer diameter
Ø (mm) Art. #

Conversion kit Pumpfix ® F With 15 m cable length:


for wastewater with or without sewage Ø 110 205-091
For conversion to the Komfort inspection chamber Ø 125 205-092
with Pumpfix ® F backwater valve. Ø 160 205-093

Conversion kit Staufix ® FKA With 15 m cable length:


for wastewater with or without sewage Ø 110 80 083
For conversion to the Komfort inspection chamber Ø 125 80 082
Backwater protection for exterior installation

with Staufix ® FKA backwater valve. Ø 160 80 082

Conversion kit Staufix ® SWA Ø 110 80 095


for wastewater with or without sewage Ø 125 80 095
For conversion to the Komfort inspection chamber Ø 160 80 095
with Staufix ® SWA backwater valve.

Cable piping gasket set Ø 110 85 410


5
1 Pipe sealing gasket
2 KG-collar plug 3 Twin collar Ø 110
1 2
3 4 HT-collar plug 5 Cable connections
4 6 6 Retaining clip with screws

Further installation depths (Ø 1000) up to a max. installation depth of 5 m can be assembled individually using the accessory parts,
see inspection chambers sides S 20/21. Cable piping is provided to enable subsequent retrofit (Set Art. # 85 410).

R 16
Controlfix clean out
in the Komfort-Inspection chamber System Ø 800 and Ø 1000
according to EN 752 for underground installation
Ø 800 Ø 1000
Channel
types Installation depth D Art. # Installation depth D Art. #
Ø* Ø*
in mm Class A/B Class D in mm Class A/B Class D

Backwater protection for interior installation


1 Continuous pipe: 1 Continuous pipe (Ø 200 on request):
D 1: Ø 110 842 101 B 842 101 D D 1: Ø 110 862 101 B 862 101 D
Ø 125 842 102 B 842 102 D Ø 125 862 102 B 862 102 D
770 - 1270 mm Ø 160 842 103 B 842 103 D 950 - 1450 mm Ø 160 862 103 B 862 103 D
D 2: Ø 110 842 111 B 842 111 D D 2: Ø 110 862 111 B 862 111 D
Ø 125 842 112 B 842 112 D Ø 125 862 112 B 862 112 D
1270 - 1770 mm Ø 160 842 113 B 842 113 D 1450 - 1950 mm Ø 160 862 113 B 862 113 D
Channel example
Ø 1000 Ø 110 842 121 B 842 121 D Ø 110 862 121 B 842 121 D
D 3: D 3:
Ø 125 842 122 B 842 122 D Ø 125 862 122 B 862 122 D
1770 - 2270 mm Ø 160 842 123 B 842 123 D 1950 - 2450 mm Ø 160 862 123 B 862 123 D
D 4: Ø 110 842 131 B 842 131 D D 4: Ø 110 862 131 B 862 131 D
Ø 125 842 132 B 842 132 D Ø 125 862 132 B 862 132 D
2270 - 2770 mm Ø 160 842 133 B 842 133 D 2450 - 2950 mm Ø 160 862 133 B 862 133 D
D 5: Ø 110 842 141 B 842 141 D D 5: Ø 110 862 141 B 862 141 D
Ø 125 842 142 B 842 142 D Ø 125 862 142 B 862 142 D
2770 - 3270 mm Ø 160 842 143 B 842 143 D 2950 - 3450 mm Ø 160 862 143 B 862 143 D
2 Single inlet in flow direction right 90°:
D 1: Ø 110 862 201 B 862 201 D
Ø 125 862 202 B 862 202 D
950 - 1450 mm Ø 160 862 203 B 862 203 D
D 2: Ø 110 862 211 B 862 211 D
Ø 125 862 212 B 862 212 D
1450 - 1950 mm Ø 160 862 213 B 862 213 D
Channel example Ø 110 862 221 B 862 221 D
Ø 1000 D 3:
Ø 125 862 222 B 862 222 D
1950 - 2450 mm Ø 160 862 223 B 862 223 D
D 4: Ø 110 862 231 B 862 231 D
Ø 125 862 232 B 862 232 D
2450 - 2950 mm Ø 160 862 233 B 862 233 D
D 5: Ø 110 862 241 B 862 241 D
Ø 125 862 242 B 862 242 D
2950 - 3450 mm Ø 160 862 243 B 862 243 D
3 Single inlet in flow direction left 90°:
D 1: Ø 110 862 301 B 862 301 D
Ø 125 862 302 B 862 302 D
950 - 1450 mm Ø 160 862 303 B 862 303 D
D 2: Ø 110 862 311 B 862 311 D
Ø 125 862 312 B 862 312 D
1450 - 1950 mm Ø 160 862 313 B 862 313 D
Channel example
D 3: Ø 110 862 321 B 862 321 D
Ø 1000 Ø 125 862 322 B 862 322 D

Backwater protection for exterior installation


1950 - 2450 mm Ø 160 862 323 B 862 323 D
D 4: Ø 110 862 331 B 862 331 D
Ø 125 862 332 B 862 332 D
2450 - 2950 mm Ø 160 862 333 B 862 333 D
D 5: Ø 110 862 341 B 862 341 D
Ø 125 862 342 B 862 342 D
2950 - 3450 mm Ø 160 862 343 B 862 343 D
4 Twin inlets in flow direction left + right 90°:
D 1: Ø 110 862 401 B 862 401 D
Ø 125 862 402 B 862 402 D
950 - 1450 mm Ø 160 862 403 B 862 403 D
D 2: Ø 110 862 411 B 862 411 D
Ø 125 862 412 B 862 412 D
1450 - 1950 mm Ø 160 862 413 B 862 413 D
D 3: Ø 110 862 421 B 862 421 D
Channel example Ø 125 862 422 B 862 422 D
Ø 1000 1950 - 2450 mm Ø 160 862 423 B 862 423 D
D 4: Ø 110 862 431 B 862 431 D
Ø 125 862 432 B 862 432 D
2450 - 2950 mm Ø 160 862 433 B 862 433 D
D 5: Ø 110 862 441 B 862 441 D
Ø 125 862 442 B 862 442 D
2950 - 3450 mm Ø 160 862 443 B 862 443 D

* Ø = Outer Diameter

R 17
Accessories
KESSEL Extension section made of polymer Complete KESSEL extension section made of polymer
for standard concrete rings/BEGU-covers for load classes A/B/D
for load classes A/B/D
Backwater protection for interior installation

Article Art. #
Cover plate in cast iron
with ventilation,
Class A 860 134
Standard BEGU-cover Class B 860 135
Further assembly possible using Class D, locked 860 137
additional concrete rings
Class B: H = 125 mm Sludge bucket 860 115
Class D: H = 160 mm
Cover plate in cast iron
Standard bearing ring Class A 860 130
(anti-slip; AR-V) Class B 860 131
H = 30, 50, 100, 120 ...... mm
Cover plate in cast iron
Class A, locked 860 132
Class B, locked 860 133
Class D, locked 860 136
not suitable for extension section 860141

Article Art. #
Article Art. #
Extension section made of 860 120
Extension section made polymer with clamping ring,
of polymer for standard telescopic height adjustable
bearing ring/ from 100 to 550 mm, for cover
BEGU-covers Class A/B/D, with cut-outs for
can be assembled using a sludge bucket
standard concrete rings;
Extension section made of 860 121
telescopic height adjustable
polymer with clamping ring,
from 50 to 280 mm 860 122
telescopic height adjustable
telescopic height adjustable from 100 to 550 mm, for cover
from 50 to 550 mm Class A/B/D
860 125

Extension section made of 860 141


polymer with clamping ring,
telescopic height adjustable
from 100 to 550 mm, for cover
in cast iron with insertion depth
50 mm, for surface water tight
covers, unlocked

Article Art. # Article Art. #


Backwater protection for exterior installation

Lip gasket Ø 600 860 116 Lip gasket Ø 600 860 116

Calculation for installation depth D Calculation for installation depth D

Inspection chamber height H 1 to H 5


Height of extension section Inspection chamber height H 1 to H 5
from 50 - 280 mm (50 - 550 mm) Height of extension section
Height of concrete ring/BEGU-cover from 100 to 550 mm
Cover plate

R 18