You are on page 1of 9

WL Job Quality Assesment (Pre/Post) Code Form: SLD-OFS-FOR-235-00

Class: Private

Personnel
Job General Information Well Information Job Technical Information
Information
WL Work-Order Number 23-03-39 Well Name AZNS-52-WO1 Service CBIL-GR-CCL Lead Engineer E. Cheraghsahar
Mobilization Date 8/Mar/23 Hole Size 9.625 IN & 7IN Assistant Engineer
Location Azadegan Depth (TD) 4140 m Conveyance WL Trainee Engineer
Client South Azadegan Casing Size 7 in Crew Chief M. Ghaderi
Rig Name TDDC-301 Casing Shoe Depth 4128 m Unit/Truck Number Truck 9901
Field Name South Azadegan Logging Interval 4125 m - 50 m
NA
Rig Contact Number N/A Y Max Deviation Vertical Workshop/Offshore Box No.
M. Tahvili
High Profile Job? E ✘

Crew Members M,. Hazabipour


(TLC, First job for the Client, HPHT, Appraisal Max Temprature N/A Cable Length 5900 m
well) S
Mud Type Water Based Mud (85 pcf) WeakPoint Rating 6K
YES NO

H2S ppm? N/A Assigned Cell? Cell#1,Orange
Wellhead Pressure N/A FSM F.Kazemi
Before Job
Quality Check and certifications Yes / No / NA Engineer Comment FSM Comment Tools and Equipment Check Yes / No / NA Engineer Comment FSM Comment

✘ ✘
Unit/Truck Q check valid? Cable Torture test passed?

Main and BU equipment have


Is Cable without Splice?
valid Q-check? ✘ ✘

Rig Up Equipment have valid MPI? ✘ Depth, Tension, Winch Panel System Checked and Operational? ✘ checked

BOP has Pressure test and MPI? only MPI Acquisition Software checked and ✘

Operational?


PCE Pressure test valid? ✘ Cable head Serviced, Checked and Operational?

All Lifts have valid MPI certificates ✘ Back-Up for Downhole Tools and Surface Equipment Available? ✘ There is no back up panel

Cable Head Q-Check , Weak Point valid? Main and Backup Equipment have valid Calibrations for the job? ✘

TLC Equipment have valid Q-Check?



WL Main and backup Equipment have valid FIT1 and FIT2 ✘

✘ ✘
Fishing Equipment have valid MPI? Standby in Ahvaz Main and BU equipment checked in the toolstring and fully Operational (FIT3)?

Enough Auxilary Equipment has been checked, Taken and Approprite for the desired Size
Any third party Equipment involved? ✘
(Gemco-Standoff-Centralizers-Decentralizers )

Cable Certificate is valid? ✘ TLC equipment have FIT 1&2? ✘

Required Cross overs/ Adaptors have valid certificates? TLC Equipment Properly checked in the Toolstring and Operational?

Unit/Truck Pre-Job done? ✘


Journey Plan discussed with QHSE?

All required Adaptors and Cross Overs Op checked?


Crew Quality Check Yes / No / NA Engineer Comment FSM Comment Process and Documents Yes / No / NA Engineer Comment FSM Comment

Engineer has enough experience to ✘


do the job? It is my first CBIL job alone Rig Book checked and Complete? ✘

Crew Chief has enough experience to HAZMAT filled properly and Dosimeter, Hazmat keys taken?
do the job? ✘ ✘

Winch man is winch certified? (Perferably 2 Winchman) ✘

Job related procedures available and reviewed ?


Crew have basic QHSE and WL certificates
(Injury prevention, Rig-up, Radiation, First Aid,FTW,Offshore ✘

Survival(Only For Offshore Jobs), H2S, Fire, Pressure, Explosive,


✘ RISCOT for the job available and reviewed?
NEST)

Personel had enough rest to do the job?


Service ticket available?



will be completed after
job at wellsite
List of Main Concerns & Exemptions: Toolstring designed according to the client need? ✘

1- There is no back up for Panels. Logging program prepared?


2- Back up CBIL sonde has not been run before. 3. Reviewed past failures, LFI and best practises relevant to the Operation? ✘

This is first my CBIL job job alone.

After Job
Job KPIs Yes / No Engineer Comment FSM Comment Job Closure Yes / No / NA Engineer Comment FSM Comment
46 Hrs

Confirmation of data reception by PE?


Operating Hours?

✘ All rig book elements filled properly?


NPT Hours? 5 Hrs NPT was considered

Any Service Quality incident? ✘ Online info ( cable, cablehead ) updated?

Field Ticket signed by client?


✘ (Document attached) ✘
Any HSE incident?
Operators appraisal filled by Eng?
Any CMSL?
✘ (Document attached) ✘
Sources back to the PIT and
Any Misfire?
E
Y ✘
HAZMAT closed? Dosimeter, keys returned? ✘
Any UPO? Job Report filled properly with tool operation hour details?
E ✘ ✘

In case of failure, RCR of the job


Any ODP? S ✘ initiated? (RCR Number) ✘
Asset controler received the
Job Quality Check (Execution) Yes / No / NA Engineer Comment FSM Comment equipment at the base? ✘ there is no asset controller

Job is done according to logging program? FIT1,FIT2 and FIT 3 completed? (With post job handover to the Owner)

Job performed without any deviation from standard ✘


UBHO and other auxilliary devices returned? ✘

procedures?


Client was satisfied with Data?

5 hrs was considered due to


Client was satisfied with timing? ✘
CBIL sonde failure Failure Investigation Yes / No / NA Engineer Comment FSM Comment

Client was satisfied with In case of failure, Investigation


Sealand Personnel? ✘ started? ✘

Equipment tagging done properly? Immediate cause determined? ✘

Journey plan followed? Root cause determined?




Tool Depth (m) Normal Tension (lbs) MSP (lbs)
Class : Private SLD-OFS-FOR-129-02

WireLine

COMPANY TDDC

WELL AZNS-52

FSM Farshid Kazemi

Engineer E. Cheraghsahar

Mobilization from Ahwaz base to wellsite TDDC-301


Standby for Job
Safety meeting and pressure test
Rig up and MU string and Surface check
RIH with tool string designed for liner 7in
Recording Main Log & Repeat Log
POOH
Modyfying Tool string for casing 9.625in and servicing torepedo
RIH second run till liner lap 7in
Calibration and Recording Main Log till 3500m
Tool failure, POOH to change tools with back up and RIH
RIH till 3500m and recording main log and repeat log
Rig down
Service ticket and data delivery and taking rest
Crew left the Rig

Run1: Power adaptor(93877)-Swivel(sy-xj-13-05-02)-TTRm(10295100)-CCL(1


10202271)_FLEX(13103951)_Cartridge(1671EA-10150818)_CBIL(1671MB-10
Run2: Power adaptor(93877)-Swivel(sy-xj-13-05-02)-TTRm(1029510
Main Tool String : 10202271)_FLEX(13103951)_Cartridge(1671EA-188543)_CBIL(1671MB-1015
Run3: Power adaptor(93877)-Swivel(sy-xj-13-05-02)-TTRm(10295100)
10200278)_FLEX(13103951)_Cartridge(1671EA-10150818)_CBIL(1671MB-18
Total operation Run1: 4 Hrs,
hrs. of the string:

Job Highlights
Interval was long and managed to record it.

It was my first CBIL job.


Job Lowlights and Suggestion
Client consider 5 hrs NPT

Number of Runs: 3 Instructions


Loss Time in This Job: 5 hrs * Number of Runs: Every set of service
Failure in this Job: yes * Loss Time: Please consider every Loss
Total Operation Time: 46 hrs * Loss Severity: According to severity c
No. of failed run: 1 Main IDW :
Failure Severity: Serious Main Load Cell :
Completed By: Lead Enginner E. Cheraghsahar
Remarks: Note : Job report should be completed in 72 hours after rigging do
WireLine Job Report

Rig TDDC-301

Location AHVAZ

Service CBIL-GR-CCL

Work Order no. 23-03-39

8-Mar-23 13:00
8-Mar-23 16:30
9-Mar-23 7:30
9-Mar-23 8:30
9-Mar-23 10:30
9-Mar-23 14:00
9-Mar-23 18:00
9-Mar-23 21:00
9-Mar-23 23:00
10-Mar-23 2:30
10-Mar-23 6:30
10-Mar-23 9:30
11-Mar-23 3:45
11-Mar-23 5:30
11-Mar-23 12:00

-02)-TTRm(10295100)-CCL(12-05-07)-Tele(3514-10041337)-GR(1329-091306)-ORIT(4401-
10150818)_CBIL(1671MB-10150030).
xj-13-05-02)-TTRm(10295100)-CCL(12-05-07)-Tele(3514-10184846)-GR(1329-091306)-ORIT(4401-
188543)_CBIL(1671MB-10150030),
13-05-02)-TTRm(10295100)-CCL(12-05-07)-Tele(3514-10184846)-GR(1329-091306)-ORIT(4401-
10150818)_CBIL(1671MB-188534).
Run2: 4 H
Run3: 20 Hrs.

s
of Runs: Every set of service RIH.
e: Please consider every Loss time even if it is not raised by client.
rity: According to severity classification, L<10K$ , 10K<S<100K$ , 100K<M<1M$, M>1 M$
8 Main Acqusition System
15 Main Laptop :

72 hours after rigging down.


Service Ticket No.
23-03-39

Job Date 3/9/2023

Run No. 3

Truck No. Truck-9901

8-Mar-23 16:30
9-Mar-23 7:30
9-Mar-23 8:30
9-Mar-23 10:30
9-Mar-23 14:00
9-Mar-23 18:00
9-Mar-23 21:00
9-Mar-23 23:00
10-Mar-23 2:30
10-Mar-23 6:30
10-Mar-23 9:30
11-Mar-23 3:45
11-Mar-23 5:30
11-Mar-23 12:00

6)-ORIT(4401-
9-091306)-ORIT(4401-

091306)-ORIT(4401-
Run2: 4 Hrs,
3: 20 Hrs.

1M$, M>1 M$
BHDC Acquisition panel
HP Work station
DATE 3/12/2023