You are on page 1of 1

Condition Report

Soltec Quantis DeLaval 18.12.2009

General appearance / Function:

We were unable to open the machine hood due to a fault in the control. After the fault was
repaired at our facility and we could inspect the tunnel and could see that there was very
extensive contamination of flux due to lack of maintenance. The chain was completely dry
indicationg lack of lubrication over a longer period of time. The transport speed was not constant
due to the same lack of lubrication. Width adjust did not work and the drive motor for this was
slipping on its clutch. Again, this is due to lack of maintenance/lubrication.

4 of the heat zone blowers were defective and generated a great deal of noise when started.

There was a periodical fault where the computer could not communicate with the machine
controller. This was found to be due to a bad 24volt power conditioner which needs repair at our
workshop.

The following parts are required:

4pcs 207160 Motor WNF 71 230/400V 0.4KW EUR 935,00/ea


Div parts Power conditioner repair EUR 50,00

You might also like