Application Interrupted Uninterrupted The SW85 has been designed for direct current loads, particularly
motors as used on electric vehicles such as industrial trucks. Developed
Thermal Current Rating (Ith) 100A for both interrupted and uninterrupted loads, the SW85 is suitable for
Intermittent Current Rating: switching Resistive, Capacitive and Inductive loads.
30% Duty 185A
40% Duty 160A
• Interrupted current - opening and closing on load with frequent
switching (results in increased contact resistance).
50% Duty 140A
60% Duty 130A • Uninterrupted current - no or infrequent load switching requirements
70% Duty 120A (maintains a lower contact resistance).
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:
(in accordance with UL583*) The SW85 features single pole double breaking main contacts with silver alloy
SW85 800A at 48V tips, which are weld resistant, hard wearing and have excellent conductivity.
SW85B 800A at 80V The SW85 has M8 stud main terminals and 6.3mm spade coil connections.
Rated Fault Current Breaking Capacity (Icn) Resistive Load: Mounting is via M4 tapped holes or mounting brackets, either supplied fitted,
(in accordance with UL508*) or as separate items. Mounting can be horizontal or vertical, when vertical the
SW85 150A at 48V D.C. M8 contact studs should point downwards. If the requirement is for upwards
SW85B 150A at 96V D.C. orientation we can adjust the contactor to compensate for this. Please note
Normally Closed contacts are not suited to make and break load. SW85
Maximum Recommended Contact Voltages (Ue):
SW85 48V D.C. Dimensions in mm [inches]
SW85B 96V D.C.
Typical Voltage Drop per pole
50mV
across New Contacts at 100A
Mechanical Durability >5 x 106 Cycles
Coil Voltage Available (Us)
From 6 to 240V D.C.
(Rectifier board required for A.C.)
Coil Power Dissipation:
Highly Intermittent Rated Types 20 - 30 Watts
Intermittently Rated types 15 - 20 Watts
Prolonged Rated Types 13 - 15 Watts
Continuously Rated Types 7 - 13 Watts
Maximum Pull-In Voltage (Coil at 20˚ C) Guideline:
Highly Intermittent Rated types
60% Us
(Max 25% Duty Cycle)
Intermittently Rated types
60% Us
(Max 70% Duty Cycle)
Prolonged Operation
60% Us
(Max 90% Duty Cycle)
Continuously Rated Types
66% Us
(100% Duty Cycle)
Drop-Out Voltage Range 10 - 25% Us
Typical Pull-In Time 20ms
Typical Drop-Out Time (N/O Contacts to Open):
Without Suppression 5ms
With Diode Suppression 50ms
With Diode and Resistor
8 - 20ms SW85 Available Options
(Subject to resistance value) SW85 Contactor Performance
Typical Contact Bounce Period 3ms General Suffix
900
Operating Ambient Temperature - 40˚C to + 60˚C Auxiliary Contacts ○ A
800 Auxiliary Contacts - V3 ○ C
Guideline Contactor Weight:
700 Figures are for guideline Magnetic Blowouts† ○ B
SW85 360 gms purposes only
Time (Seconds)
0
0
0
10
20
50
60
70
80
30
40
0 Current (Amperes)
2A at 48V D.C. Contacts
Albright International
Albright International, 125 Red LionLtd, Evingar
Road, Trading
Surbiton, Estate,
Surrey KT6Ardglen Road, Whitchurch,
7QS, England,Tel: Hampshire,
+44 (0) 20 RG28
8390 5357, Fax:7BB, UK20 8390 1927
+44 (0)
Tel: +44
E-mail: (0)1256 893060, Fax: +44 (0)1256
sales@albrightinternational.com 893562, Dedicated Sales Tel: +44 (0)1256
or technical@albrightinternational.com 890030,
Web Site: Fax: +44 (0)1256 890043
www.albrightinternational.com
E-mail: sales@albrightinternational.com or technical@albrightinternational.com Web Site: www.albrightinternational.com
v4-06-20 Copyright © 2010 Albright International Ltd SW85