Application Interrupted Uninterrupted The SW80 has been designed for direct current loads, including motors
as used on electric vehicles such as industrial trucks, and telecom and
Thermal Current Rating (Ith) 100A 125A power distribution applications. Developed for both interrupted and
Intermittent Current Rating: uninterrupted loads, the SW80 is suitable for switching Resistive,
30% Duty 185A 230A Capacitive and Inductive loads.
40% Duty 160A 200A
• Interrupted current - opening and closing on load with frequent
50% Duty 140A 175A switching (results in increased contact resistance).
60% Duty 130A 160A
70% Duty 120A 150A • Uninterrupted current - no or infrequent load switching requirements
(maintains a lower contact resistance).
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:
(in accordance with UL583*)
SW80 600A at 48V
The SW80 features single pole double breaking main contacts with silver
alloy tips, which are weld resistant, hard wearing and have excellent
SW80B 600A at 96V
conductivity. The SW80 has M8 stud main terminals and 6.3mm spade coil
Rated Fault Current Breaking Capacity (Icn) Resistive Load: connections. Mounting is via M4 tapped holes or mounting brackets, either
(in accordance with UL508*)
supplied fitted, or as separate items. Mounting can be horizontal or vertical,
SW80 190A at 60V D.C.
when vertical the M8 contact studs should point upwards. If the requirement is
SW80B 190A at 96V D.C. SW80
for downwards orientation we can adjust the contactor to compensate for this.
Maximum Recommended Contact Voltages (Ue):
Dimensions in mm [inches]
SW80 48V D.C. 60V D.C.
SW80B 96V D.C.
Typical Voltage Drop per pole 40mV
across New Contacts at 100A
Mechanical Durability >5 x 106 Cycles
Coil Voltage Available (Us)
From 6 to 240V D.C.
(Rectifier board required for A.C.)
Coil Power Dissipation:
Highly Intermittent Rated Types 20 - 30 Watts
Intermittently Rated types 15 - 20 Watts
Prolonged Rated Types 13 - 15 Watts
Continuously Rated Types 7 - 13 Watts
Maximum Pull-In Voltage (Coil at 20˚ C) Guideline:
Highly Intermittent Rated types 60% Us
(Max 25% Duty Cycle)
Intermittently Rated types 60% Us
(Max 70% Duty Cycle)
Prolonged Operation 60% Us
(Max 90% Duty Cycle)
Continuously Rated Types 66% Us
(100% Duty Cycle)
Drop-Out Voltage Range 10 - 25% Us
Typical Pull-In Time 20ms
Typical Drop-Out Time (N/O Contacts to Open):
Without Suppression 5ms
With Diode Suppression 50ms
SW80 Contactor Performance SW80 Available Options
With Diode and Resistor 8 - 20ms General Suffix
(Subject to resistance value)
900
Typical Contact Bounce Period 3ms Auxiliary Contacts ○ A
800
Operating Ambient Temperature - 40˚C to + 60˚C
Auxiliary Contacts - V3 ○ C
700 Figures are for guideline Magnetic Blowouts† ○ B
Guideline Contactor Weight: purposes only
Time (Seconds)
0
0
SW80C SW80A
10
20
50
60
70
80
30
40
• Performance data provided should be used as a guide only. Some de-rating or variation
M5 Terminal Board ○
from figures may be necessary according to application. Vacuum Impregnation ○
• Thermal current ratings stated are dependant upon the size of conductor being used Key: Optional ○ Standard ● Not Available X
• For further technical advice email: technical@albrightinternational.com †
Connections become polarity sensitive
• Albright reserve the right to change data without prior notice ‡
Open Housing Available
Albright International
Albright International, 125 Red LionLtd, Evingar
Road, Trading
Surbiton, Estate,
Surrey KT6Ardglen Road, Whitchurch,
7QS, England,Tel: Hampshire,
+44 (0) 20 RG28
8390 5357, Fax:7BB, UK20 8390 1927
+44 (0)
Tel: +44
E-mail: (0)1256 893060, Fax: +44 (0)1256
sales@albrightinternational.com 893562, Dedicated Sales Tel: +44 (0)1256
or technical@albrightinternational.com 890030,
Web Site: Fax: +44 (0)1256 890043
www.albrightinternational.com
E-mail: sales@albrightinternational.com or technical@albrightinternational.com Web Site: www.albrightinternational.com
v6-01-20 Copyright © 2010 Albright International Ltd SW80
Copyright © 2020 Albright International LTD