Professional Documents
Culture Documents
TABLE OF
CONTENTS
SHT. NO. SHEET CONTENT CITY OF KABANKALAN
A1 PERSPECTIVE
SITE DEV'T PLAN
5 VICINITY MAP
FLOOR PLAN
A2 4 - ELEVATIONS
2 - SECTIONS
SCHEDULE OF
5 DOORS & WINDOWS
FOUNDATION PLAN
S1 COL. & FTG.DETAIL
WALL FTG. DETAIL
ROOF FRAMING
5 PLAN
TRUSS DETAIL
ROOF BEAM DETAIL
ARCHITECTURAL
SPECIFICATION
LEGEND
P1 PLUMBING LAY-OUT
SEPTIC VAULT
SANITARY/PLUMBING
SITE
9°52'33"N 122°48'00"E
SET
-BA
CK
9°52'32"N 122°48'00"E
D ELECTRICAL
RO A
VICINITY MAP
NOT DRAWN TO SCALE SITE DEVELOPMENT PLAN
SCALE 1:100m
MECHANICAL
PRC 0132129 CERTIFIED: PROJECT TITLE: APPROVED: SHEET CONTENT: PREPARED BY: SHEET NO.
TIN 454-766-396
PTR 1628323 ENGR. DANILO D. RIVAS JR. TWO-STOREY RESIDENTIAL BUILDING GEMMA SEDAYON EASTICK AS SHOWN WV
A1
DATE 09-04-2019
CAR-CAR CITY, CIVIL ENGINEER LOCATION: BRGY. TAMPALON, KABANKALAN CITY OWNER
5
PLACE CEBU
8.00
6.00 2.00
W5
W1 W1 W1
APEX OF TRUSS APEX OF TRUSS
1.50
1.50
1.90
1.90
D2
DIRTY KITCHEN T&B
D2 D3
TOP OF RB TOP OF RB
1.10
2.80
2.80
3.85
DINING KITCHEN
W1 W1
2.75
2.90
2.90
3.00
3.00
W1 BEDROOM W1
15.00
FFL FFL
.10
.10
D2
3.00
W1
W1 SCALE 1:75m
BEDROOM
UP
D1
W1
3.50
APEX OF TRUSS APEX OF TRUSS
1.50
1.50
2.75
PORCH
3.25
TOP OF RB TOP OF RB
DIMENSION
2.80
MARK DESCRIPTION QTY.
2.80
W H
4.00 4.00 D1 PANEL DOOR 0.90 2.10 1
D2 SLAB DOOR 0.80 2.10 4
D3 PVC DOOR 0.60 2.10 2
3.00
2.90
2.90
W2 GLASS SLIDING WINDOW 1.00 1.20 5
W6 W4 W5
W3 TRIPLE SLIDING GLASS WINDOW 2.00 1.20 1
D2
.10
.10
0.50 0.70
1.70
T&B
NGL NGL
2.75
W4
BEDROOM
D2 D3
W2
REAR ELEVATION RIGHT ELEVATION
1.55
W2
W4 APEX OF TRUSS APEX OF TRUSS
3.00
W4 LIVING
1.50
1.50
16.41
TOP OF RB TOP OF RB
5.50
DN BEDROOM
2.80
2.80
3.00
W4
BEDROOM
W4
2.90
4.26
4.26
TERRACE
FFL
.10
FFL
.10
NGL NGL
.40
PRC 0132129 CERTIFIED: PROJECT TITLE: APPROVED: SHEET CONTENT: PREPARED BY: SHEET NO.
2nd Floor TIN 454-766-396
TWO-STOREY RESIDENTIAL BUILDING AS SHOWN A2
PTR 1628323 ENGR. DANILO D. RIVAS JR. GEMMA SEDAYON EASTICK WV
5
DATE 09-04-2019
CAR-CAR CITY, CIVIL ENGINEER LOCATION: BRGY. TAMPALON, KABANKALAN CITY OWNER
PLACE CEBU
10.00
1.00 4.00 4.00 1.00
8.00 B1 B1 B1 B1
G.A. 16 x 2 x 3 C-PURLINS
6.00 2.00
C1/F1 C1/F1 C1/F1 1.00 SPACED AT 0.65M OCBW
WF1
3.00
3.00
S1 S1 B1
1.00
S1 S1 B1
B1 B1
B1
1.90
1.90
WF1
RB RB G.A. 14 x 2 x 6 C-PURLINS W/
WF1 C2 C2 C2 10mm DSB WEB MEMBERS
B1 B1 B1 B1
1.10
2.75
2.75
S1 S1 S1 B1 S1 B1
B1 B1
B1
3.85
S
US
HA
TR
2.75
LF
LF
C2 C2 C2
TR
HA
US
B1 B1 B1 B1
4.00
S
C1/F1 C1/F1 C1/F1 G.A. 14 x 2 x 6 C-PURLINS W/
WF1
10mm DSB WEB MEMBERS
ROOF TRUSS ROOF TRUSS
1.49
3.00
3.00
B1 S1 S1 B1 S1
B1 B1 S1 B1
16.00
3.00
3.00
RB RB
15.00
WF1
C2 C2
B1 B1 B1 B1
3.40 1.20 3.40
C1/F1 C1/F1
ROOF TRUSS ROOF TRUSS
C1/F1
3.00
3.00
B1 S1 B1 S1 B1 B1 S1 B1 B1
S1
HA
SCALE 1:75m
LF
US
3.00
3.00
TR
TR
WF1
US
LF
C2 C2
S
C2
HA
B1 B1 B1 B1
2.75
3.50 S1 B1
B1 S1 B1 B1
3.25
S1 B1
S1
2.75
RB
3.25
B1 L L
B1
B1
1.00
L/5 L/5 L/5 L/5
C1/F1 S1 S1
1.00
WF1 B1 S1 B1
S1
.50
.50
C1/F1 C1/F1 B1
B1 B1
WF1
.40
4.00 4.00 L/3 L/3
3.60 2.70 3.60
9mm DIA STIRRUPS SPACED
ROOF FRAMING PLAN @ 2 - 0.05m, 4 - 0.10m, REST @ 0.20m
FOUNDATION PLAN LIVING AREA SECOND FLOOR BEAM AND SCALE 1:85m
SCALE 1:100m SLAB LAY-OUT
SCALE 1:100m BEAM KEY PLAN
SCALE 1:20 m
.25
.1 4
.30
.20
.20
0.30
10mm DIA. TEMP. W/ 9mm DIA. TIES
STAIR SECTION DETAIL BARS
SCALE 1:35m SPACED @ 0.25m O.C 2 @ 0.05m
4 @ 0.10m 0.20 0.20
12mm DIA. REST @ 0.20m O.C.
BENT BARS ALTERNATE 2-16mm DIA. BARS
NGL W/ STRAIGHT BARS 5-16mm DIA. BARS
0.30
0.30
SPACED @ 0.25m O.C
0.075m THK. CONCRETE SLAB
ON FILL W/ 10mm DSB 8-16mm DIA. MAT BARS SPACED @ 2-16mm DIA. BARS 5-16mm DIA. BARS
MATT BARS
C1
0.15m O.C.B.W.
.80
0.25
8-16mm DIA. MAT BARS SPACED @
0.15m O.C.B.W. 4" THK. CHB WALL
10mm DIA. HOR. BARS
@ EVERY 3 LAYERS
W/ 9mm DIA. TIES
2 @ 0.05m
4 @ 0.10m
0.15 B1 0.15
REST @ 0.20m O.C. 4-12mm DIA. BARS 2-12mm DIA. BARS
C1/F1 10mm DIA. VER. BARS
0.25
0.25
@ 0.60m O.C.
1.40
.80
3-10mm DIA
C2 AT SUPPORT AT MIDSPAN
.20
HORIZONTAL BARS
W/ 9mm DIA TIES 10mm DIA STIRRUPS SPACED @
1.40
WF COLUMN DETAIL
SCALE 1:25
RB1
FOOTING (F1) DETAIL WALL FOOTING DETAIL SLAB 1 DETAIL (S1) BEAM DETAIL
SCALE 1:35m SCALE 1:75m SCALE 1:25
SCALE 1:20m
PRC 0132129 CERTIFIED: PROJECT TITLE: APPROVED: SHEET CONTENT: PREPARED BY: SHEET NO.
TIN 454-766-396
PTR 1628323 ENGR. DANILO D. RIVAS JR. TWO-STOREY RESIDENTIAL BUILDING GEMMA SEDAYON EASTICK AS SHOWN WV
S1
DATE 09-04-2019
CAR-CAR CITY, CIVIL ENGINEER LOCATION: BRGY. TAMPALON, KABANKALAN CITY OWNER 5
PLACE CEBU
SPECIFICATIONS
LEGEND 1. ALL ELECTRICAL WORKS AND INSTALLATION SHALL
COMPLY WITH THE LATEST EDITION OF PHIL. ELECTRICAL
PANEL BOARD CODE
CEILING LIGHT OUTLET
2. ALL ELECTRICAL WORKS HEREIN SHALL BE
S1 ONE-WAY GANG SWITCH EXPERIENCED MEN UNDER THE DIRECT SUPERVISION OF
A FULL TIME LICENSED ELECTRICAL ENGINEER. WORK
S2 TWO-WAY GANG SWITCH SHALL BE NEATLY PLACED, SECURELY FASTENED AND
S3 THREE WAY GANG SWITCH
PROPERLY FINISHED.
S3W THREE WAY SWITCH 3. SERVICE VOLTAGE SHALL BE 220 VOLTS SINGLE PHASE
CONVENIENCE OUTLET 4. SERVICE ENTRANCE SHALL BE RUN IN RCG PIPES
TO SERVICE RUN
5. BRANCH CIRCUIT INSTALLATIONS FOR BOTH LIGHTING
CIRCUIT LINE AND POWER SHALL RUN IN PVC PIPES
UP
SWITCH LINE 6. LIGHTING BRANCH CIRCUIT SHALL BE TWO-WIRE
3.5mm² + GROUND WIRE IN 15mm DIA. PVC PIPE
M METER
7. ALL CIRCUIT BREAKER SPECIFIED IN THE SCHEDULE
OF LOADS SHALL BE STRICTLY FOLLOWED
SCHEDULE OF LOADS
TOTAL SIZE OF
GROUND FLOOR ELECTRICAL MARK DESCRIPTION V W WIRE PROTECTION
SECOND FLOOR ELECTRICAL CURRENT
POWER & LIGHTING LAY-OUT
SCALE: 1:75m POWER & LIGHTING LAY-OUT C1 10CLO 220 1000 4.54
2-3.5mm²
THW 15A
SCALE: 1:75m
2-3.5mm²
SITE C2 10CO 220 3300 15 THW 30A
M
SPARE
__A __A
SPARE 2-3.5mm²
C5 C6 C6 SPARE 220 THW
PRC CERTIFIED: PROJECT TITLE: APPROVED: SHEET CONTENT: PREPARED BY: SHEET NO.
TIN
PTR TWO-STOREY RESIDENTIAL BUILDING GEMMA SEDAYON EASTICK AS SHOWN WV
E1
DATE ELECTRICAL ENGINEER LOCATION: BRGY. TAMPALON, KABANKALAN CITY OWNER
5
PLACE
TO PUBLIC SEWER
4" DIA PVC PIPE
CB
SV
KS FAU WC LAV FD
FAU FAU SHO 1. PROVIDE 2% SLOPE FOR IN-HOUSE SEWER LINE
JOINTS.
VTR, CO 2. FOR SANITARY AND VENT PIPE LINES, USE PVC
WC LAV FD
FAU FAU SHO
PIPES.
3. FOR WATER SUPPLY LINES, USE UPVC BLUE PIPES &
FITTINGS.
4. JOINTS ARE PROVIDED WITH UPVC SOLVENT
CEMENT SO AS TO MAKE WATER TIGHT
5. CLEAN OUTS ARE PROVIDED WITH COVER SO AS TO
FACILITATE EASY REMOVAL
6. EXTEND VENT THRU ROOF AT LEAST A FOOT ABOVE
ROOF.
7. ALL OTHER ASPECTS NOT FOUND ON THIS PLAN,
THE PROVISION AND REQUIREMENTS OF THE
NATIONAL BUILDING CODE OF THE PHILS. (PD 1096),
THE PLUMBING CODE OF THE PHILS. (RA 1378) AND
UP EXISTING LOCAL PLUMBING CODE AT ALL TIME
SHALL PREVAIL.
1.50 0.90
0.10 0.100.10 0.10 0.10
0.45 0.50 0.45 0.50
0.10
0.25
0.50
1.00
MANHOLE MANHOLE
C.O C.O C.O
GROUND FLOOR
PLUMBING LAYOUT SECOND FLOOR
0.25
0.10
SCALE 1:75m PLUMBING LAYOUT
SCALE 1:75m LEGENDS
1st Floor SITE GATE VALVE PLAN
CB
M METER
KS SV
FA
U VTR, CO
CHECK VALVE 10mm DIA. BARS SPACED
TO
4" PU @ 0.20m O.C. BOTH WAYS
DIA BLI
PV C SE
C P WE WC
IPE R
FA U LA V
FD DRAIN
FA U FD
0.40
SH O
CB BASIN AIR SPACE AIR SPACE
1.80
FR
1/2 OM
LAV LAVATORY
1.20
" D WA 4" THK. CHB
IA TE PLASTERED WALL
PV R S
C B UP
WC LUE PLY
WA
FA U LA V TER
LIN
KS KITCHEN SINK DIGESTIVE
CHAMBER LEACHING
FA U FD E CHAMBER
SH O
M
FAU FAUCET LEAN CONC. 2%
FLOORING SLOPE
VTR THRU ROOF
0.20
VICINITY MAP SHO SHOWER
NOT DRAWN TO SCALE
----- WATER LINE SEPTIC VAULT DETAIL
ISOMETRIC VIEW SCALE 1:25m
NOT DRAWN TO SCALE SEWER LINE
PRC CERTIFIED: PROJECT TITLE: APPROVED: SHEET CONTENT: PREPARED BY: SHEET NO.
TIN
TWO-STOREY RESIDENTIAL BUILDING AS SHOWN P1
PTR GEMMA SEDAYON EASTICK WV