GE Digital Energy introduces enhancements to the Multilin 469 Motor Management Relay through the release of
firmware version 5.20, and EnerVista Setup Software version 5.20.
Upgrading from a previous version of the Multilin 469 Setup software to the new 5.20 version can be done via
EnerVista Launchpad or downloaded directly from our website:
http://www.gedigitalenergy.com/multilin/software/469.htm
Please contact your local GE Multilin sales representative or Multilin Customer Service Department (CST) for
any questions regarding this upgrade.
GE Digital Energy 1
Multilin 469 FW & SW v5.20 Release Notes
Release Details
In the following enhancement descriptions, a revision category letter is placed to the left of the
description. Refer to the Appendix at the end of this document for a description of the categories
displayed.
The Multilin 469 Motor Management Relay has been enhanced to provide a loss of communication detection
feature. Upon detection of a loss of communications, the Multilin 469 relay will activate an alarm or trip assigned
output relays. Based on the relay’s selected communications options on the Multilin 469 relay, any one of the
following ports may be selected for loss of communications monitoring:
- COMPUTER RS485
- AUXILIARY RS485
- Ethernet 10Base-T
- DeviceNet
Please refer to the Multilin SR469 instruction manual (document # GEK-106474M) section 5.12.5 for more details.
In previous firmware versions (version 5.12 and prior) for the Multilin 469 relay, the Starter Failure Alarm Delay
would always function in 200ms, ignoring the delay setting. Firmware version 5.20 corrects this issue.
2 GE Digital Energy
Multilin 469 FW & SW v5.20 Release Notes
The Multilin 469 EnerVista Setup Software Version 5.20 has been enhanced to support the Loss of
Communication Detection feature. The following setpoints have been added to the setup software under the
following menu: Settings -> Monitoring -> Loss of comms
The specific setpoints added to support this enhancement is as follows:
The following Actual Values have been added to support this feature:
The following Events have been added to the Event Recorder to support this feature:
Loss of Comms Alarm
Loss of Comms Trip
Upgrade Paths
This upgrade can be done either via Multilin EnerVista Launchpad or by direct download from the following site:
http://www.gedigitalenergy.com/multilin/software/469.htm
Please contact your local Multilin sales representative or Multilin Customer Service Department (CST) for any
questions regarding this upgrade.
GE Digital Energy 3
Multilin 469 FW & SW v5.20 Release Notes
Appendix
Change categories
This document uses the following categories to classify the changes.
Table 1: Revision categories
N New feature A separate feature added to the relay. Changes to existing features even
if they significantly expand the functionality are not in this category
G Change A neutral change that does not bring any new value and is not correcting
any known problem
D Changed, incomplete or false Changes to, or problems with text messages, LEDs and user pushbuttons
faceplate indications
R Changed, incomplete or false relay Changes to, or problems with relay records (oscillography, demand, fault
records reports, etc.)
C Protocols and communications Changes to, or problems with protocols or communication features
P Protection out of specification Protection operates correctly but does not meet published specifications
(example: delayed trip)
The revision category letter is placed to the left of the change description.
Technical Support
Contact information and call center for product support is shown below:
GE Digital Energy – Grid IQ Center
650 Markland Street
Markham, Ontario
Canada L6C 0M1
Telephone: 905-927-7070 or 1-800-547-8629 (North America), +34 94 485 88 00 (Europe)
Fax: 905-927-5098 (North America), +34 94 485 88 45 (Europe)
(North America), +34 94 485 88 45 (Europe)
E-mail: multilin.tech@ge.com
Home Page: www.GEDigitalEnergy.com/Multilin
4 GE Digital Energy