Clean Water Tank (Cylindrical)

3
0.1244 MG 470.9976 m
Inlet Volumetric Flowrate= ≈
day day

0.1244 MG
Based from the standard API 650 Tank Sizes, at inlet flowrate of ; the following dimensions
day
are available to minimize the equipment cost. Moreover, it is to consider that the plant will need
approximately 230 000 gallons for 1 day operation. Considering the conditions, for a capacity of 250000
gallons;
Tank Diameter= 40 ft or 12.1951 m
Height= 20.0833 ft or 5.3056 m
π 2
Volume of the tank= × D × H
4
π 2
Volume of the tank= ×(12.1951 m) ×5.3056 m
4
3
Volume of the tank=619.7194 m

Summary
Tank Diameter= 40 ft or 12.1951 m
Height= 20.0833 ft or 5.3056 m
Volume of the tank= 619.7194 m3