Control Devices A10VO/5x

DR/DRG
Pressure control
Slide title
Remote pressure control
DFR/DFR1
DRF/DRS
LA..
Pressure, flow
and power control
EP..
Elektro proportional
displacement control
EK..
Electro proportional control with
deactivation of EP function
ED
Pressure control electrical
with negative characteristic
ER
Pressure control electrical
with positiver characteristic
Pressure and flow control

DR LADS EPDF EKDS

Pressure control DR Pressure and flow control DFR Power control with: Electr.-Prop-control with: Electr.-Prop-control with The maximum pump output The maximum pump output
The pressure control limits the In addition to the pressure LA.D deactivation of EP function and pressure is set through a pressure is set through a
EP.D
maximum pressure at the control function, the pump flow pressure control with: command current signal to the command current signal to the
pressure control
pump output within the pump may be varied by means of a LA.DG ED-valve solenoid. ER-valve solenoid.
EK.DF
control range. The variable differential pressure over an remote pressure control EP.DF When load pressure reaches When load pressure reaches
pressure and flow control
pump only supplies as much orifice or valve spool installed in LA.DS pressure and flow control this pressure level, the pump´s this pressure level, the pump´s
X_T open
hydraulic fluid as is required the service line to the actuator. pressure and flow control X_T open control valve spool shifts and control valve spool shifts and
by the consumers. If the The pump flow is equal required LA.S EK.DS causes an increase or decrease causes an increase or decrease
EP.DS
operating pressure exceeds flow by the actuator, regardless with pressure and flow control pressure and flow control in the pump´s swivel angle (flow) in the pump´s swivel angle (flow)
pressure and flow control
the pressure setpoint set at of changing pressure levels. electrical adjustment of differential X_T closed in order to maintain this set in order to maintain this set
X_T closed
the integrated pressure valve, pressure pressure level. pressure level.
DFR X – T open EK.ED
the pump will adjust towards EP.ED When the solenoid current When the solenoid current
electro-hydraulic pressure
a smaller displacement. The DFR1 X – T closed electro-hydraulic pressure signal drops towards a zero signal drops towards a zero
control
pressure can be set steplessly control value, the maximum output value, the pump´s output
at the control valve. pressure is limited by an pressure will also drop to the
adjustable mechanical pressure pmin level (Standby).
cut off (secure fail safe function
Pressure control DRG in case of a loss of power e.g.
A presure relief valve can be for use as fan drive).
externally piped to port X for
remote setting of pressure
below the setting of the DR
control valve spool. The
differential pressure is set as
standard 20 bar.

Further information see RE 92708 Further information see RE 92708 Further information see RE 92707 Further information see RE 92707
Further information see RE 92711 Further information see RE 92711 Further information see RE 92703

Confidential | 02.04.2013 | SPP2 | © Bosch Rexroth AG 2013. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as