You are on page 1of 8

Instrumentation Control Unit, ICU3 54.

11
Mode/Reset Switch Functions

Use the following flow charts to cycle through the


Mode/Reset switch functions and screens.
See Fig. 1, Fig. 2, Fig. 3, Fig. 4, Fig. 5, Fig. 6, and
Fig. 7.

Business Class M2 Workshop Manual, Supplement 20, September 2011 410/1


54.11 Instrumentation Control Unit, ICU3
Mode/Reset Switch Functions

IGNITION OFF

HEADLIGHTS ON Yes

NO 123456.7
MI Yes
TURN OFF
ODOMETER

IGNITION ON No HEADLIGHTS ON
No IGNITION ON
No
Yes
Yes
TURN OFF
ODOMETER
888888.8 Self−test:
TRIP MI KM HOURS clockwise sweep
38.8 VOLTS SERVICE
ENGINE

Screen displayed for three seconds.


Self−test: Alternate between each active fault code.
2_2.0
counterclockwise sweep

PARK BRAKE ON Yes ACTIVE FAULT Yes ICU 140 SERVICE

No No The SERVICE screen


will be displayed as an
123456.7 active fault code
MI No PARK BRAKE ON
when the miles or
12.3 VOLTS
hours are exceeded in
Yes the service interval.

No Reset/Mode
Press Reset/Mode No
Press

Yes

A Go to Fig. 2 for Trip Screens Yes

B From Fig. 2 and Fig. 3 D

Go to Fig. 3 for Other Screens

Yes IGNITION ON

No

RETURN

04/10/2006 f040607

Fig. 1, Mode/Reset Switch Start Sequence

410/2 Business Class M2 Workshop Manual, Supplement 20, September 2011


Instrumentation Control Unit, ICU3 54.11
Mode/Reset Switch Functions

From Fig. 1

Metric version screen is similar


to English version screen.

123456.7
TRIP MI Hold To Reset Trip Miles
12.3 VOLTS

Push

123456.7
TRIP HOURS Hold To Reset Trip Hours
12.3 VOLTS

Push

PARK BRAKE ON Yes C Go to Fig. 3

No

Eng Spd < Road Spd <


Yes Yes C Go to Fig. 3
500 RPM 2 MPH

No
No

Go to Fig. 1
04/07/2006 f040608

Fig. 2, Mode/Reset Switch Trip Screens

Business Class M2 Workshop Manual, Supplement 20, September 2011 410/3


54.11 Instrumentation Control Unit, ICU3
Mode/Reset Switch Functions

From Fig. 2
SELECt
To Toggle Between Units
C *MI Hold
MI <−−> KM

From Fig. 1 Push *Flash Screen Text

dIAG
See Fig. 4 and 5 for
MI HOURS Hold
Diagnostic screen functionality
n SERVICE
n = Number of Active Fault Codes
Push
MI SERVICE= Service miles enabled
HOURS SERVICE= Service hours enabled

No Miles < 254?

Yes

CLEAr donE
Hold

Clear
Push Faults Push

123456.7
To Display Total Engine Miles
MI
MI ENGINE = Engine miles
ENGINE
Push

123456.7
To Display Total Engine Hours
HOURS
HOURS ENGINE = Engine hours
ENGINE

Push
*Lo = Oil Level Low
HI = Oil Level High
Blank = Oil Level OK oiL
See Fig. 6 for Engine Oil Level
− − = No message Hold
screen functionality
*Lo ENGINE

Push

SEt UP See Fig. 7 for Set Up


**Display Hold Service Interval screen
**MI **HOURS
active mode functionality
**no SERVICE
MI SERVICE= Service miles active mode
Push
HOURS SERVICE= Service hours active mode
no SERVICE= Service Interval inactive

B Go to Fig. 1
05/20/2002 f040609

Fig. 3, Mode/Reset Switch Engine Miles and Service Screens

410/4 Business Class M2 Workshop Manual, Supplement 20, September 2011


Instrumentation Control Unit, ICU3 54.11
Mode/Reset Switch Functions

From Fig. 1

n = Number of *If fault goes inactive, *If fault goes inactive,


Active Fault Codes display "noFault 1" display "noFault n"

dIAG
*FAULt *FAULt
Hold Hold Hold
n 1 n

Push Push Push

AbS 11 ENG 0
Hold Hold

Go to Fig. 3 Push Push

SPN 004 SPN 110


Hold Hold

Push Push

FAIL 03 FAIL 00
Hold Hold

Push Push

04/18/2011 f040610b

Fig. 4, Mode/Reset Switch Fault Screens

Business Class M2 Workshop Manual, Supplement 20, September 2011 410/5


54.11 Instrumentation Control Unit, ICU3
Mode/Reset Switch Functions

From Fig. 1

Metric version screens are similar to


D
English version screens.

n = Number of
*If fault goes inactive,
active fault codes
**If Service miles enabled display "noFault n"
dIAG *−12345
**MI *FAULt
Hold **MI Hold Hold
n SERVICE n
SERVICE

Push Push Push


**MI SERVICE indicates
that Service miles enabled
*Display miles remaining in Interval (positive),
Flash if Service Interval miles exceeded (negative)
Go to Fig. 3
Hold

Push Display Fault Code


see Fig. 4

From Fig. 1

n = Number of
active fault codes *If fault goes inactive,
**If Service Hours enabled display "noFault n"
dIAG *−1234
Hold *FAULt Hold
**HOURS **HOURS Hold
n SERVICE SERVICE n

Push **HOURS SERVICE Push Push


indicates that Service hours
enabled
*Display hours remaining in Interval (positive),
*Flash if Service hours exceeded (negative)

Hold
Go to Fig. 3

Push Display Fault Code


see Fig. 4
04/07/2006 f040611

Fig. 5, Mode/Reset Switch Service Screens

410/6 Business Class M2 Workshop Manual, Supplement 20, September 2011


Instrumentation Control Unit, ICU3 54.11
Mode/Reset Switch Functions

English Units

oiL −1 qtS
*If Oil Level Low Hold Hold
*Lo ENGINE *Lo ENGINE
Push Push

oiL 1 qtS
*If Oil Level High Hold Hold
*HI ENGINE *HI ENGINE
Push Push

oiL −0 qtS
*If Oil Level OK Hold Hold
* ENGINE * ENGINE
Push Push

Metric Units

oiL −1 LtS
*If Oil Level Low Hold Hold
*Lo ENGINE *Lo ENGINE
Push Push

oiL 1 LtS
*If Oil Level High Hold Hold
*HI ENGINE *HI ENGINE
Push Push

oiL −0 LtS
*If Oil Level OK Hold Hold
* ENGINE * ENGINE
Push Push

04/29/2002 f040612

Fig. 6, Mode/Reset Switch Oil Level Screens

Business Class M2 Workshop Manual, Supplement 20, September 2011 410/7


54.11 Instrumentation Control Unit, ICU3
Mode/Reset Switch Functions

From Fig. 3
Metric version screens are similar to
English version screens.

SEt UP rESEt
Hold will reset all service
**MI **HOURS Hold Hold
internal counters.
**no SERVICE SERVICE

Push **Display active mode Push

To toggle between
*MI *HOURS Hold
MI−−>HOURS−−>no−−>
*no SERVICE

Push *Flash Screen Text

To toggle between
The no selection will disable lookup table hours
the Service Interval. *1234
no Selection? HOURS HOURS Hold
SERVICE

Push *Flash Screen Text


MI
To toggle between
lookup table miles
*12345
MI Hold
SERVICE

Push *Flash Screen Text

Go to Fig. 3
04/07/2006 f040613

Fig. 7, Mode/Reset Switch Reset and Toggle Screens

410/8 Business Class M2 Workshop Manual, Supplement 20, September 2011

You might also like