You are on page 1of 4

(M0085277 - null) - null Page 1 of 4

Cerrar SIS

Pantalla anterior

Producto: EXCAVATOR
Modelo: NO SE HA ESCOGIDO NINGUN EQUIPO
Configuración: NO SE HA ESCOGIDO NINGUN EQUIPO

Pruebas y Ajustes
320 GC, 320 and 323 Excavators Tool Control System
Número de medio -M0081160-00 Fecha de publicación -01/10/2017 Fecha de actualización -06/10/2017

i07026858

Joystick and Pedal - Calibrate


SMCS - 5059-FU; 5705-524

Introduction
Use the following procedure to calibrate the joysticks, thumbwheels, travel pedals, and attachment
pedals.

Machine Preparation

Illustration 1 g06181120

1. Position the machine on level ground in the service position. Refer to Illustration 1.

Calibration Procedure
Monitor Procedure

Table 1

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 9/06/2023
(M0085277 - null) - null Page 2 of 4

Modulation Input Calibrations


All Primary (Joystick F/R, Joystick L/R, Travel Pedals, and Right Attachment Pedal)
All Secondary (Joystick Thumbwheels, Blade Control Handle, and Left Attachment Pedal

Illustration 2 g06241464

1. Enter the "Service" menu on the monitor.

a. Enter password "9992".

2. Select "Calibration" menu.

3. Select "Modulation Inputs".

4. Select appropriate calibration to be completed. Refer to Table 1.

5. Follow the instructions on the monitor to complete the calibration.

6. If the calibration was successful and no errors occurred, the display will indicate the
calibration is complete.

Note: The "Error" screen will be displayed on the monitor if an error occurs. The process of
the calibration will not be saved and the process must be restarted.

ET Procedure

Table 2

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 9/06/2023
(M0085277 - null) - null Page 3 of 4

Modulation Input Calibrations


All Levers and Pedals Calibration (Machine Control)
All Levers and Pedals Calibration (Implement Control #2)

1. Select the ECM for "Machine Control" or "Implement Control #2".

2. Select "Calibrations" from the "Service" menu.

3. Select "Modulation Input Calibrations".

4. Select appropriate calibration to complete. Refer to Table 2.

5. Select "Start".

6. Follow the instructions on the screen to complete the calibration.

7. If no error occurs, the calibration was completed successfully.

Test Procedure
Use the following procedure to verify the joystick calibration.

Note: The hydraulic activation lever should be in the LOCKED position during the test
procedure.

Illustration 3 g06241477

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 9/06/2023
(M0085277 - null) - null Page 4 of 4

1. Enter the "Service" menu on the monitor.

a. Enter password "9992".

2. Select "Status" menu.

3. Select "Operator Input - Joystick".

4. Verify that the joysticks read 0% when all the control levers are in the NEUTRAL position.

5. Move the joystick to the full BOOM RAISE position and verify that the "Boom Lever
Position" reading is 99 to 100%.

6. Slowly return the joystick to the NEUTRAL position.

Note: Verify that the "Boom Lever Position" reading immediately reduces from 100% when
coming off end stop and has a smooth transition to 0%.

7. Move the joystick to the full BOOM LOWER position and verify that the "Boom Lever
Position" reading is -99 to -100%.

8. Slowly return the joystick to the NEUTRAL position.

Note: Verify that the "Boom Lever Position" reading immediately increases from -100%
when coming off end stop and has a smooth transition to 0%.

9. Repeat Step 5 to Step 8 for the following functions.

◦ Stick Lever Position

◦ Bucket Lever Position

◦ Swing Lever Position

Note: If the joystick function does not meet the test procedure specifications, then perform
the calibration procedure again.

10. Repeat the test procedure for all functions within "Operator Input - Travel", "Operator Input
- Tool", and "Operator Input - Pedal/Lever".

Copyright 1993 - 2023 Caterpillar Inc. Fri Jun 9 20:03:57 EST 2023
Todos los derechos reservados.
Red privada para licenciados del SIS.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 9/06/2023

You might also like