You are on page 1of 53

Vendor Document / Document Front sheet

Integration Procedure of Telecom system WHP and


Document Title:
FPSO
MEPN Doc No.: ID-F-FT-P-TD001-A08-00001

Vendor Doc No.: ID-F-FT-P-TD001-A08-00001 Vendor Rev: 0B (IFA)

MEPN Group Owner: PDO - Project Delivery Offshore

Area: FT – FOREL

Location: WP - FOREL WHP

System: 86 – Telecommunication

Document Type: A08 - Project Procedures / Plans

Discipline: J - Instrumentation Subdiscipline: J4 - Telecommunications

Submitted For:
FOREL PROJECTS
Review Certified Info
Review does not constitute acceptance of design Supplier Name: PT. JETEC INDONESIA
details, calculations, test methods or materials
developed or selected by supplier nor does it relieve
supplier from full compliance with contractual or other
obligations

1. Approved to Proceed (Submit final Package No.: TD001


documents in MDR/OM only).
manufacture may proceed

2. Approved with comments (Revised & Package Description / Brand :


resubmit document).
Manufacture may proceed once comment Local Panel
actioned

3. Rejected (Revised & Resubmit). Work


may not proceed.
SDRL Prime Code : A08 - Project Procedure /
Plans
4. For Information Only (submit final
documents in MDR/IOM only),
Manufacture may proceed PO. No. : SP-21305-002-II-22
Name :

Tag No. : -
Date :
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 2 of 23

Revision Sheet

REVISION DATE DESCRIPTION OF CHANGE

0A 31 Oct 22 Issued for Comment

0A 31 Oct 22 Page 1

CPY comments on 23 Nov 22


the document content is mostly similar to SAT procedure, and the
content is not referred to POC for L3 Switch and DMR redundancy
scenario. Vendor to further explore integration activity and test.
MEI/Jetec Response: Incorporated.

0A 31 Oct 22 Page 3

CPY comments on 23 Nov 22

tidy

MEI/Jetec Response: Incorporated.

0A 31 Oct 22 Page 14

CPY comments on 23 Nov 22


1. with minimum disturbance with existing facility
2. Prepare drawings and related docs for testing
MEI/Jetec Response: Incorporated.

0A 31 Oct 22 Appendix A

CPY comments on 23 Nov 22


1. consider to perform BER test or link availability test on certain
time and measure the available bandwidth.
2. revise wording , refer to POC and the result. L3 switch cannot
take over the communication.
3. revise the wording, try to describe it further, POC procedure and
result may be referred and followed.
4. Monitor & record vessel draft for antenna elevation
5. compare to CCTV study document bandwidth.
6. base station...
7. add: via UHF repeater
MEI/Jetec Response: Incorporated.

0A 31 Oct 22 Appendix B

CPY comments on 23 Nov 22


1. revise the sentence, DMR or even L3 Switch provided cannot
take over communication link, refer to POC procedure and
result.please be more specific.
2. ...could...
3. add the prococedure, application/software to be used,
preparation required to the laptop such as IP or something else.
4. and compare against the CCTV study document ... number...
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 3 of 23

5. add step by step and preparation so that Commissioning


engineer can do follow and perform the test.
6. ensure communication Bronang WHP to Forel WHP can be
established via UHF repeater with 17km distance. consider the
maximum power of Handheld in Forel WHP to reach UHF
Repeater in Bronang. recheck the philosophy- and project
requirement, what equipment shall communicate with.
MEI/Jetec Response: Incorporated.

0A 31 Oct 22 Appendix G

CPY comments on 23 Nov 22

seems the title and Appendixes G and H are swapped.

MEI/Jetec Response: Incorporated.

0B 26 Jan 23 Issued for Approval

Additional Approvers (If Applicable)

Name Designation Signature Date


Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 4 of 23

Contents
1 INTRODUCTION .................................................................................................................................... 5
1.1 Purpose ......................................................................................................................................... 6
1.2 Scope ............................................................................................................................................ 6
1.3 Reference Documents .................................................................................................................. 6
1.3.1 Company Specifications and Standards .......................................................................... 6
1.3.2 Project Documents .......................................................................................................... 6
2 DEFINITIONS, ABBREVIATIONS & UNITS ......................................................................................... 7
2.1 Definitions ..................................................................................................................................... 7
2.2 Abbreviations ................................................................................................................................ 7
2.3 Units .............................................................................................................................................. 8
3 GENERAL DESIGN REQUIREMENT.................................................................................................... 8
3.1 Control Overview .......................................................................................................................... 8
3.2 Hazardous Area Classification and Protection ............................................................................. 9
3.3 Environmental Condition ............................................................................................................... 9
4 INTEGRATION PROCEDURE SUMMARY ......................................................................................... 10
4.1 Forel WHP Telecom System ...................................................................................................... 10
4.2 Bronang WHP Telecom System ................................................................................................. 11
4.3 Belanak FPSO Telecom System ................................................................................................ 11
4.4 Integration Tools ......................................................................................................................... 11
4.5 Location ...................................................................................................................................... 12
4.6 Acceptance ................................................................................................................................. 12
5 INTEGRATION PLANNING AND MANPOWER ................................................................................. 12
5.1 Manpower ................................................................................................................................... 12
5.2 Interdisciplinary Coordination and Responsibility ....................................................................... 12
5.3 HSE Management....................................................................................................................... 13
6 INTEGRATION REQUIREMENT ......................................................................................................... 13
7 INTEGRATION PROCEDURE ............................................................................................................. 14
7.1 Bronang WHP – Belanak FPSO Integration Test Procedure ..................................................... 14
7.2 Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure ................................ 14
8 List of Appendix.................................................................................................................................. 15
Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure ........................................ 16
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure .................. 17
Appendix C – Certificate of Completion Bronang WHP – Belanak FPSO ........................................... 18
Appendix D – Certificate of Completion Bronang WHP – Forel WHP - Forel FPSO ........................... 19
Appendix E – Job Safety Analysis (JSA) ................................................................................................ 20
Appendix F – Livening Up Notice (LUN) ................................................................................................. 21
Appendix G – Bronang WHP – Belanak FPSO Integration Architecture ............................................. 22
Appendix H – Bronang WHP – Forel WHP and Forel FPSO Integration Architecture ....................... 23
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 5 of 23

1 INTRODUCTION
Medco E & P Natuna Ltd, hereafter known as COMPANY, is undertaking the development of Forel-
Bronang fields as part of the ongoing program for the development of oil and gas fields in the South
Natuna Sea Block B Production Sharing Contract Area from the Republic of Indonesia in 300 feet of
water as illustrated in Figure 1. Production from this field is estimated to start at the end of 2023.

Figure 1.1 South Natuna Block B PSC Location Map


Forel field development requires gas injection source for pressure maintenance and lifting gas to the
reservoir. Gas lift source is also required to optimize Forel’s crude oil production. The Bronang field is
developed to supply the import gas requirement of Forel field for gas injection and fuel gas.
The design of Forel and Bronang field production facilities are dry tree concept where all production
wells will be placed on a wellhead platform (WHP) that is designed unmanned with the concept of the
Minimum Facility Platform (MFP) which is designed with a simple technology system but has a high
level of reliability and requires minimum intervention and maintenance.
Forel production wells will be routed to Floating Production, Storage and Offloading (FPSO)
via multiphase flexible pipeline for further processing to meet crude oil market requirement,
while the gas is boosted to meet the gas lift and gas injection pressure requirement. The
Bronang production will be also routed to FPSO via Forel WHP to supply gas injection at initial
production phase and fuel gas throughout Forel production lifetime.
Integration Forel project with Bronang gas Development comprises additional two production wells,
manifolds, and well test meter. Production fluids from three production wells are comingled in
production header then split into Forel FPSO via Forel WHP and to Hang Tuah MoGPU via new 14”
– 30km pipeline connected to existing Bawal PLEM and existing 40km of 14” Bawal pipeline.
At Hang tuah MoGPU, fluids received in existing slug catcher for liquid/produced water separation and
commingled with current gas production from Buntal-5 and Belida for further gas treatment and
processing. Gas will be compressed up to 1500 psig to meet GSA-1and GSA-2 gas specification.
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 6 of 23

1.1 Purpose
The purpose of this document is as reference and guidance for methodology and documentation /
record of Integration Procedure Telecom System WHP and FPSO. This test shall be performed to
verify and validate that the functionality of the equipment, hardware and software, related to EPCI of
Wellhead Platforms and Pipeline for Forel Bronang Project are meet project requirement and
specification.

1.2 Scope
The scope of this Integration Procedure Telecom System WHP and FPSO covers for the Telecom
System at Forel WHP, Bronang WHP, and additional Telecom System at Belanak FPSO.

1.3 Reference Documents


1.3.1 Company Specifications and Standards

FIN-IS-GL-00005 Telecommunication System Standard Specific for Capital


Projects
ID-F-BU-GG0-REL-GN-00-0001 Approved Manufacture List
ID-F-BU-EE2-STS-GN-80-0002 Cable Gland and Accessories
ID-F-BU-EE0-STS-GN-80-0013 Electrical, Instrument and Telecommunication Cables

1.3.2 Project Documents

ID-F-FT-JJ4-SPC-GN-86-0001 Telecommunication Specification for Forel & Bronang WHP

ID-F-FT-JJ4-PHI-GN-86-0002 Telecommunication Philosophy for WHP


ID-F-FT-JJ4-BLK-GN-86-0001 Overall Telecommunication System Block Diagram
ID-F-FT-JJ4-PRQ-WP-00-0001 Material Requisition for Telecommunication
ID-F-FT-P-TD001-H05-00002 Data Network and Microwave Radio System FAT Procedure
ID-F-FT-JJ4-BLK-WP-86-0001 Forel WHP Data Network System & DMR Block Diagram
Forel WHP Data Network and Digital Microwave Radio
ID-F-FT-JJ4-DSR-WP-86-0003
Datasheet
ID-F-FT-JJ4-REL-WP-86-0002 Forel WHP Telecom Equipment list
ID-F-FT-P-TD001-C02-00001 Forel WHP Telecom Panel General Arrangement and Single
Line Diagram
ID-F-FT-P-TD001-C14-00001 Forel WHP Network IP Assignment List
ID-F-FT-P-TD001-C19-00002 Forel WHP Data Network and DMR Wiring & Termination
Diagram
ID-F-FT-P-TD001-K02-00006 Forel WHP Data Network and Digital Microwave Radio
System SAT Report
ID-F-FT-P-TD001-K02-00005 Forel WHP CCTV System SAT Report
ID-F-FT-JJ4-BLK-BR-86-0002 Bronang WHP Data Network System & DMR Block Diagram
Bronang WHP Data Network and Digital Microwave Radio
ID-F-FT-JJ4-DSR-BR-86-0003
Datasheet
ID-F-FT-JJ4-REL-BR-86-0002 Bronang WHP Telecom Equipment list
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 7 of 23

ID-F-FT-P-TD001-C02-00002 Bronang WHP Telecom Panel General Arrangement and


Single Line Diagram
ID-F-FT-P-TD001-C14-00002 Bronang WHP Network IP Assignment List
ID-F-FT-P-TD001-C19-00007 Bronang WHP Data Network and DMR Wiring & Termination
Diagram
ID-F-FT-P-TD001-K02-00014 Bronang WHP CCTV System SAT Report
ID-F-FT-P-TD001-K02-00015 Bronang WHP Data Network System and Digital Microwave
Radio SAT Report
ID-F-FT-P-TD001-K02-00017 Bronang WHP UHF Radio System SAT Report
ID-F-FT-YY0-DRT-BR-00-0001 Site Survey Report Belanak FPSO

2 DEFINITIONS, ABBREVIATIONS & UNITS


2.1 Definitions
The following are the definitions of the terms used within this specification:
Project EPCI of Wellhead Platforms and Pipeline for Forel-Bronang
Project
COMPANY Medco E&P Natuna Ltd.
CONTRACTOR PT. Meindo Elang Indah
WHP CONTRACTOR Contracted party which responsible for work and/or services
related to Forel & Bronang WHP
Leased FPSO CONTRACTOR Contracted party which responsible for work and/or services
related to Forel FPSO
SYSTEM INTEGRATOR The party, which performs the duties or services of ICSS and
Telecommunication specified by CONTRACTOR
VENDOR The party, which manufacturers or supplies the equipment,
goods, material and services as specified by the COMPANY
or CONTRACTOR

2.2 Abbreviations
CCR : Central Control Room
CCTV : Closed-Circuit Television
CPY : Company
CTR : Contractor
DMR : Digital Microwave Radio
FOBOT : Fiber Optic Break Out Tray
FPSO : Floating Production, Storage & Offloading
ICSS : Integrated Control and Safety System
LAN : Local Area Network
LPU : Lightning Protection Unit
LUN : Livening Up Notice
MEPN : Medco E&P Natuna
MFP : Minimum Facility Platform
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 8 of 23

ODU : Outdoor Unit


OWS : Operator Workstation
PIDU : Power Indoor Unit
PLC : Programmable Logic Controller
PPE : Personal Protective Equipment
PTZ : Pan – Tilt – Zoom
SAT : Site Acceptance Test
SI : System Integrator
UHF : Ultra High Frequency
UPS : Uninterruptible Power Supply
VSAT : Very Small Aperture Terminal
WAN : Wide Area Network
WHP : Wellhead Platform

2.3 Units
The project shall use the system of units as given in doc.no. ID-F-FT-PP0-BOD-GN-00-
0001_R9_Integrated Basis of Design, for all calculations, drawings and in all project documentation.
All structural, flowlines and layout documents shall use the metric system. All vendor documentation
and equipment shall also utilize equivalent systems.

3 GENERAL DESIGN REQUIREMENT


3.1 Control Overview
Forel & Bronang WHP are designed as a minimum unmanned facility. A combination of Wellhead
Control Panel (WHCP) and PLC based control system will be utilized for Forel & Bronang WHP
automation system. For the Leased Forel FPSO, an Integrated Control & Safety System (ICSS) will
be utilized for its topside facilities automation system. The vessel’s marine automation system shall
be fully independent; however, it may be integrated with the Leased FPSO Topside ICSS for
monitoring functions. Fault tolerant and redundant architecture will be implemented for entire
systems.
Bronang WHP has two operation scenarios, the first scenario is Bronang on stream align with existing
Forel Bronang Project schedule. The second scenario is Bronang earlier on stream before Forel, this
scenario is contingency plan for anticipation in case Forel FPSO late delivery. Production control and
monitoring during Bronang earlier on stream will be handle from Belanak FPSO. Gas production from
WHP Bronang will directly export to Hang Tuah as sales gas.
The WHP automation system will be fully integrated to FPSO ICSS to perform remote control,
monitoring, and safeguarding from the Leased FPSO via Digital Microwave Radio and subsea fiber
optic (umbilical cable). Control and automation of the WHP shall be fully automated for operation
from Leased Forel FPSO CCR.
Digital Microwave Radio system shall be provided for redundant communication (Active - Active)
links between Bronang WHP and Forel WHP for the purposed of transmit and receive data
communication (ICSS and CCTV). The antenna will be installed at Bronang WHP and Forel WHP.
Hence data communication from Bronang WHP will be transmitted to Leased Forel FPSO via subsea
fiber optic (umbilical cable) for monitored / controlled remotely from FPSO.
All data from ICSS at Forel WHP, Bronang WHP and Leased Forel FPSO will be able to be monitored
from Jakarta office via VSAT located at Forel WHP.
An alarm will be raised on the FPSO in the event of a telecommunications link failure.
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 9 of 23

Figure 2 – Forel Bronang Field Development

3.2 Hazardous Area Classification and Protection


Electrical installation for gas atmosphere will be in accordance with IEC 60079-14. The degree of
protection of telecommunication equipment, enclosures will be in accordance with the IEC 60529.
All field electronic equipment will comply with requirements of the hazardous area classification in
which they are installed as minimum of:
Table 3.1 Hazardous Area Classification

Weather Protection Explosion Proof Protection

Indoor Outdoor Zone 0 Zone 1 Zone 2 Unclassified


Field
IP 42 IP 65 Ex ia Ex d Ex d Ex d
Equipment
Junction
IP 42 IP 65 Ex ia Ex e Ex e Ex e
Box
Cabinet IP 42 IP 65 Ex ia Ex d Ex d Ex d

All field telecommunication equipment mounted outdoor will be designed for installation in an area
classification Zone 2, Gas Group IIA, Temperature class T3 and shall be certified Ex d as minimum
in hazardous area. Zone 0 or Zone 1 certified equipment shall be provided when it is required by
the hazardous area classification.
Due to high temperature, humidity and salt content, tropic proofing shall be applied to ensure
equipment operate continuously without their normal physical and functional reliability being
affected by the tropical environment. Tropic proofing shall be accomplished by applying protective
coating to prevent the growth of fungus, corrosion and absorption of moisture.
If any specific instruments are unable to comply with above requirements, CTR / SI shall inform
CPY for approval.

3.3 Environmental Condition


All equipment shall be designed and suitable for the climate and site conditions as described in
document no. ID-F-FT-PP0-BOD-GN-00-0001 “Integrated Design Basis”.
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 10 of 23

Table 3.2 Meteorogical Data & Air Temperature

Parameter Unit Value

Mid-depth °C (°F) 27.9 (82.2)


Mean Sea Temp.
Near-bed °C (°F) 24.5 (76.1)

Wind Speed 3s gust


m/s (ft/s) 23.7 (77.8)
(100-year return period)

Mid-depth m/s (ft/s) 0.65 (2.13)


Current Speed
(100-year return period)
Near-bed m/s (ft/s) 0.35 (1.15)

Maximum Air Temperature °C (°F) 36.1 (97)

Mean Air Temperature °C (°F) 31.1 (88)

Minimum Air Temperature °C (°F) 20.0 (68)

The marine growth can be taken as 2.0” (5.0 cm) for all elevations with 1325 kg/m3 marine growth
density.

4 INTEGRATION PROCEDURE SUMMARY


The integration procedure of telecom system consists of DMR System, CCTV System and UHF
Repeater. There are activities will be done to ensure the DMR System, CCTV System and UHF
Repeater can be operated as per approved design properly and safely with outline as follows :
• Data Network DMR and UHF Radio parameter check :
o Check DMR local parameter
o Check bandwidth link DMR
o Check redundant test DMR
o Check Data Network local parameter
o Check UHF Repeater Radio local parameter
• CCTV parameter check :
o Local camera test in WHP
o Data CCTV Camera System from Bronang WHP can be monitored and controlled from
Belanak FPSO Control Room
o CCTV camera in Forel WHP and Bronang WHP can be accessed from Forel FPSO.

4.1 Forel WHP Telecom System


Forel WHP Telecom system which consists of :
• Data Network and DMR System, consists of :
o 2 units DMR Antenna
o 2 units ODU
o 2 units LPU
o 2 units Telecom Panel, which consist of :
− 1 unit Layer 3 Switch
− 2 units ICSS Switch
− 1 unit CCTV Switch
− 1 unit VSAT Modem (CPY Supply)
− 2 units DMZ Switch
− 1 unit LAN/WAN Switch
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 11 of 23

− 2 units FOBOT
− 2 units PIDU
• CCTV System, consists of :
o 1 IP PTZ Cameras
o 1 IP Fixed Cameras
o 2 units CCTV Junction Box
o 2 units CCTV Washers

4.2 Bronang WHP Telecom System


Bronang WHP Telecom system which consists of :
• Data Network and DMR System, consists of :
o 2 units DMR Antenna
o 2 units ODU
o 2 units LPU
o 1 units Telecom Panel, which consist of :
− 1 unit Layer 3 Switch
− 2 units ICSS Switch
− 1 unit CCTV Switch
− 2 units PIDU
• CCTV System, consists of :
o 2 units IP Fixed Camera
o 2 units CCTV Junction Box
o 2 units CCTV Washer
• UHF Repeater, consists of :
o 1 unit UHF Radio Antenna
o 1 units UHF Radio Panel, which consist of :
− 1 unit Radio Repeater
− 1 unit Radio Duplexer
− 1 unit Lightning Arrester

4.3 Belanak FPSO Telecom System


Additional Belanak FPSO Telecom system which consists of :
• Data Network and DMR System, consists of :
o 2 units DMR Antenna
o 2 units ODU
o 2 units LPU
o 1 unit Layer 3 Switch
o 2 units PIDU
• CCTV System, consists of :
o 1 unit NVR
o 1 unit CCTV Workstation completed with Monitor
o 1 unit CCTV keyboard

4.4 Integration Tools


The Integration tools consists of :
• Multimeter
• Hand toll
• Laptop
• Radio handheld
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 12 of 23

4.5 Location
The Integration will be held in Offshore Forel WHP, Bronang WHP and Belanak FPSO.

4.6 Acceptance
Formal Integration Telecom System acceptance shall be indicated by a Certificate of Completion,
which shall be signed by all parties involved as a proved that Integration Telecom System has been
performed.
The Certificate of Completion are enclosed in Appendix C – Certificate of Completion Integration
Telecom System Bronang WHP – Belanak FPSO and Appendix D – Certificate of Completion
Integration Telecom System Bronang WHP – Forel WHP - Forel FPSO.

5 INTEGRATION PLANNING AND MANPOWER


5.1 Manpower
The following table 5.1 and 5.2 are manpower and estimate duration during Integration Telecom
System.
Table 5.1 Manpower and estimate duration for Integration Telecom System Bronang WHP to
Belanak FPSO

No Personnel Manpower Location Duration

1. Telecom Engineer 2 (two) Bronang WHP : 1 Person 3 Days


Belanak FPSO : 1 Person

2. Technician 2 (two) Bronang WHP : 1 Person 3 Days


Belanak FPSO : 1 Person

Table 5.2 Manpower and estimate duration for Integration Telecom System Bronang WHP to Forel
WHP and Forel FPSO

No Personnel Manpower Location Duration

1. Telecom Engineer 2 (two) Bronang WHP : 1 Person 4 Days


Forel WHP : 1 Person

2. Technician 2 (two) Bronang WHP : 1 Person 4 Days


Forel WHP : 1 Person

5.2 Interdisciplinary Coordination and Responsibility


The following table 5.3 is Interdisciplinary Coordination and Responsibility during Integration Telecom
System.
Table 5.3 Interdisciplinary Coordination and Responsibility

Held Assist Witness


No Responsibility Party Monitor (M) Remarks
(H) (A) (W)

1. Commissioning CTR H

2. Telecom Engineer H
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 13 of 23

Held Assist Witness


No Responsibility Party Monitor (M) Remarks
(H) (A) (W)

3. Construction MEPN M

4. Commissioning MEPN W

5. Operation MEPN W

5.3 HSE Management


1. A work permit must be issued and signed for the test with JSA.
2. Before starting work on any of the activities described in this procedure, it is the responsibility
of the persons performing the work to:
• Familiarize with the plant/equipment to be worked on.
• Read this procedure, understand its requirements and the need to carry out the tests
listed in the order detailed.
3. Ensure that the personnel are aware of all other work activities that are taking place, or due to
take place, adjacent to these activities and, if necessary, re-plan these activities to avoid any
conflict which could cause an unsafe situation.
4. Just before the test preparation and at any critical step, hold a toolbox meeting and PJSM (Pre-
Job Safety Meeting) with all the person involved in the test.
5. Any unsafe act or condition found during test activity shall be stopped and CTR shall rectify
first prior continue the job.
6. While the ISAT testing on going, the relevant system shall be constantly manned and walked
out by commissioning personnel.
7. Conduct the toolbox meeting before performing the Integration Telecom System.
8. Ensure that all people wear adequate PPE.
9. Ensure the communication means are operational.
10. Livening Up Notice (LUN). Any instrument item / electrical equipment / system that is to be
energized and put in service must be completed first with issuance of Living Up Notice by
Commissioning after verification and signed by HSE Department.

6 INTEGRATION REQUIREMENT
Other Subsystem Required for Test . The following subsystems to be completed prior to perform
Integration Telecom System.
For Bronang :
1. Solar Panel System
2. Distribution Board 24 VDC
3. Telecommunication System local Bronang WHP and additional Telecommunication System at
Belanak FPSO
For Forel :
1. Distribution Board 24 VDC
2. Telecommunication System at local Forel WHP, Bronang WHP and Forel FPSO
3. UPS System
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 14 of 23

7 INTEGRATION PROCEDURE
7.1 Bronang WHP – Belanak FPSO Integration Test Procedure
The purpose of this test is to ensure that all telecom communication system with minimum
disturbance with existing facility between Bronang WHP and additional telecom system on Belanak
FPSO integrated and function properly as per reference documents and to verify all the data
transferred is sent received correctly.

0B Step Activity Description Date Completed Name & Signature

1 Obtain permit-to-work
Prepare drawings and related documents
2 for testing
Confirm that 24 VDC distribution board, in
3 correct state at Bronang WHP
Confirm that 120 VAC distribution in
4 correct state at Belanak FPSO
Ensure network cable connection are
5 already pre-commissioned and properly
configured and connected.
Confirm that Telecommunication system
6 already power up and working properly.
Ensure the communication check is
7 already be done and all the connection
are good.
Completion of all outstanding punch items
8 in to punch list with no “A” priorities
outstanding
Check that there are not any outstanding
9 site queries/instructions that can affect
the Integration test
All the test sheet for Integration Telecom System Procedure Bronang WHP to Belanak FPSO can
be seen at Appendix A - Bronang WHP – Belanak FPSO Integration Test Procedure.

7.2 Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure
The purpose of this test is to ensure that all telecom communication system between Bronang WHP,
Forel WHP and telecom system on Forel FPSO integrated and function properly as per reference
documents and to verify all the data transferred is sent received correctly.

Step Activity Description Date Completed Name & Signature

1 Obtain permit-to-work
Confirm that 24 VDC distribution board, in
2 correct state at Bronang WHP
Confirm that UPS system already power
3 up and working properly at Forel WHP
Confirm that the telecommunication
4 system at Forel FPSO already power up
and working properly upon integration
test
Ensure network cable connection are
4 already pre-commissioned and properly
configured and connected
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 15 of 23

Step Activity Description Date Completed Name & Signature


Confirm that Telecommunication system
5 already power up and working properly at
Bronang WHP and Forel WHP
Ensure the communication check is
6 already be done and all the connection
are good.
Completion of all outstanding punch items
7 in to punch list with no “A” priorities
outstanding
Check that there are not any outstanding
8 site queries/instructions that can affect
the integration test
All the test sheet for Integration Telecom System Procedure Bronang WHP to Forel WHP and Forel
FPSO can be seen at APPENDIX B – Bronang WHP – Forel WHP and Forel FPSO Integration
Test Procedure.

8 List of Appendix
1. Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure
2. Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure
3. Appendix C – Certificate of Completion Bronang WHP – Belanak FPSO
4. Appendix D – Certificate of Completion Bronang WHP – Forel WHP - Forel FPSO
5. Appendix E – Job Safety Analysis (JSA)
6. Appendix F – Livening Up Notice (LUN)
7. Appendix G – Bronang WHP – Belanak FPSO Integration Architecture
8. Appendix H – Bronang WHP – Forel WHP and Forel FPSO Integration Architecture
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 16 of 23

Appendix A – Bronang WHP – Belanak FPSO Integration Test


Procedure
Integration Telecom System Procedure with FPSO Telecom System
Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure Page 1 of 8

1 POWER SUPPLY CHECK


The following steps are to power up the Telecom Panel and its respected equipment’s. Every time check
the incoming power of each component to ensure there are no bad power connection on components.
First of all, make sure that all breakers, fuses, or any protection devices are in OFF position.
1.1 BRONANG WHP TELECOM PANEL (86TAD-003) POWER SUPPLY CHECK

Acceptance
Measurement Result
NO Item Activity Description Objective
Result
PASS FAIL

• Check the presence of 24


VDC in TB Feeder 1 and 2
24 VDC Incoming (TB-24-F1 & TB-24-F2).
MCB-01 and MCB-02
Telecom Panel : • MCB-01 and MCB-02 in OFF
1 main circuit Breaker
• Feeder 1 Position.
function
• Feeder 2 Measure the load current of
incoming 24 VDC Feeder 1
and 2.
MCB-01 Activation of
2 Switch on MCB-01 & MCB-02
MCB-02 86-PSU-002
Measure the load current of
3 86-PSU-002 incoming is 24 VDC, and 86-PSU-002 Function
outgoing is 24 VDC

4 CB-01 Switch on CB-01 Activation of CONV-1


Measure the load current 24
5 CONV-1 VDC of incoming and outgoing CONV-1 Function
CONV-1
Activation of
6 CB-02 Switch on CB-02
86-TDC-006
7 CB-03 Switch on CB-03 Activation of CONV-2
Measure the load current 24 CONV-2 Function and
8 CONV-2 VDC for incoming and 48 VDC activation of
for outgoing CONV-2 86-TAQ-002A
9 CB-04 Switch on CB-04 Activation of CONV-3
Measure the load current 24 CONV-3 Function and
10 CONV-3 VDC for incoming and 48 VDC activation of
for outgoing CONV-3 86-TAQ-002B
The presence of 24
11 CB-05 Switch on CB-05 VDC on TB-CCTV-01,
TB 1 and 2
Activation of 86-TQN-
12 JBTE-4001 Closed TB-CCTV-01 no. 1
4001
The presence of 24
13 CB-06 Switch on CB-06 VDC on TB-CCTV-02,
TB 1 and 2
Activation of
14 JBTE-4002 Closed TB-CCTV-02 no. 1
86-TQN-4002
Activation of
15 CB-07 Switch on CB-07
86-TDC-007A
Activation of
16 CB-08 Switch on CB-08
86-TDC-007B
Integration Telecom System Procedure with FPSO Telecom System
Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure Page 2 of 8

Acceptance
Measurement Result
NO Item Activity Description Objective
Result
PASS FAIL

Activation of
17 CB-09 Switch on CB-09
86-TDC-008
The presence of 24
18 CB-10 Switch on CB-10 VDC on Input and
Output CB-10

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure Page 3 of 8

1.2 BRONANG WHP UHF RADIO PANEL (86TAD-004) POWER SUPPLY CHECK

Acceptance
Measurement Result
NO Item Activity Description Objective
Result
PASS FAIL
• Check the presence of
24 VDC in TB Feeder
24 VDC (TB-24-F1).
Incoming • MCB-01 in OFF MCB-01 main circuit Breaker
1
UHF Panel : Position. function
• Feeder 1 • Measure the load
current of incoming 24
VDC TB Feeder
2 MCB-01 Switch on MCB-01 Activation of CONV-1
Measure the load current of
CONV-1 Function and
3 CONV-1 incoming is 24 VDC, and
activation of 86-TUZ-4001
outgoing is 24 VDC
Measure the load current of
4 86-TUZ-4001 incoming is 24 VDC, and Activation of 86-TUC-4001
0B outgoing is 12 VDC

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure Page 4 of 8

1.3 BELANAK FPSO POWER SUPPLY CHECK


Acceptance
Measurement Result
NO Item Activity Description Objective
Result
PASS FAIL

Ensure the source supply


power provided is 120 VAC Measure the
Existing Power
before power-up additional load current of
1 Socket in
Data Network and Microwave power source
Belanak FPSO
Radio system for Belanak is 120 VAC
FPSO

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure Page 5 of 8

2 FUNCTIONAL TEST
This test is intended to verify local parameter of Telecom System equipments.
2.1 BRONANG WHP TELECOM SYSTEM LOCAL PARAMETER
Acceptance
Result
NO Item Activity Description Objective
PASS FAIL

IP Address Check Int. Aux 10.80.32.3 / 255.255.255.240


ODU A Frequency 5739.5 MHz
1 86-TAP-4001A
Chanel Spacing 20 MHz

Link Name BL-BR-L1


IP Address Check Int. Aux 10.80.32.19 / 255.255.255.240
ODU B Frequency 5735 MHz
2 86-TAP-4001B
Chanel Spacing 20 MHz
Link Name BL-BR-L2
VLAN 10 10.80.32.4 / 255.255.255.240

Router (Note 1) VLAN 20 10.80.32.20 / 255.255.255.240


3
86-TDC-006 VLAN 200 10.80.31.129 / 255.255.255.224
VLAN 100 10.80.31.1 / 255.255.255.224
CCTV Switch
4 VLAN 200 10.80.31.130 / 255.255.255.224
86-TDC-008
ICSS Switch A
5 VLAN 100 10.80.31.2 / 255.255.255.224
86-TDC-007A
ICSS Switch B
6 VLAN 100 10.80.31.3 / 255.255.255.224
86-TDC-007B
0B Fixed Camera 1
7 IP Address Check 10.80.31.131 / 255.255.255.224
86-TQN-4001

Fixed Camera 2
8 IP Address Check 10.80.31.132 / 255.255.255.224
86-TQN-4002

Note : 1. Layer 3 Switch with a premium license for routing protocol will be used instead of the Router due to
delivery time constraints.

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure Page 6 of 8

2.2 BELANAK FPSO TELECOM SYSTEM LOCAL PARAMETER

Acceptance
Result
NO Item Activity Description Objective
PASS FAIL

IP Address Check Int. Aux 10.80.32.5 / 255.255.255.240

ODU A Frequency 5.725 MHz


1
86-TAP-4001A
Chanel Spacing 20 MHz

Link Name BL-BR-L1

IP Address Check Int. Aux 10.80.32.21 / 255.255.255.240


0B

ODU B Frequency 5.825 MHz


2
86-TAP-4001B
Chanel Spacing 20 MHz

Link Name BL-BR-L2

VLAN 10 10.80.32.6 / 255.255.255.240

Router (Note 1) VLAN 20 10.80.32.22 / 255.255.255.240


3
86-TDC-009
VLAN 200 10.80.33.129 / 255.255.255.224
VLAN 100 10.80.33.1 / 255.255.255.224
NVR
4 IP Address Check 10.80.33.130 / 255.255.255.224
86-TQN-401
CCTV
5 WORKSTATION IP Address Check 10.80.33.131 / 255.255.255.224
86-TQY-401

Note : 1. Layer 3 Switch with a premium license for routing protocol will be used instead of the Router due to
delivery time constraints.

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure Page 7 of 8

2.3 BRONANG WHP – BELANAK FPSO COMMUNICATION TEST


The test is intended to verify :
1. Active + Active configuration for Microwave Radio System
2. CCTV monitoring and function control
3. Bandwidth monitoring
4. BER/Ethernet test or link availability test on certain time and measure the available bandwidth.

Acceptance
NO Item Activity Description Result
PASS FAIL
Bronang WHP Telecom
1 Check that all communication data traffics are up and running.
equipments
Belanak Telecom
2 Check that all communication data traffics are up and running.
equipments
Make sure Active + Active of DMR communication between
DMR Link A and B at Bronang WHP and Belanak FPSO is correct.
3 Bronang WHP / Belanak Simulate link failure between Link A and Link B by
FPSO disconnecting Link A DMR and ensuring that Link B is takes
over the communication link and vice versa.

CCTV and ICSS Check that 2 (two) CCTVs Bronang WHP and ICSS data shall
4 monitoring at Belanak be monitored from Belanak FPSO during Link A / Link B DMR
FPSO communication active,.

CCTV equipments at Check that the CCTV function / control from CCTV
5 Bronang WHP and workstation / CCTV console at Belanak FPSO into CCTV
Belanak FPSO equipments Bronang WHP are working properly.
Monitor and records bandwidth utilization via PRTG
software. Monitor bandwidth utilization on the following
Bandwidth Monitoring devices:
during test integration. • 86-TDC-009 (IP 10.80.33.1/27)
6 Monitor & record vessel • 86-TDC-006 (IP 10.80.31.1/27)
draft for antenna • 86-TDC-007A (IP 10.80.30.31.2/27)
elevation • 86-TDC-007B (IP 10.80.31.3/27)
• 86-TDC-008 (IP 10.80.31.130/27)

BER/Ethernet Test with Monitor and Record the following value for :
estimation 1 (one) hour • Throughput
7 for Link A DMR and Link • Latency
B DMR on Bronang WHP • Frame Loss
and Belanak FPSO. Ensure the overall test result are “PASS”
0B

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix A – Bronang WHP – Belanak FPSO Integration Test Procedure Page 8 of 8

2.4 BRONANG WHP – BELANAK FPSO UHF RADIO COMMUNICATION TEST


The test is intended to verify communication between UHF handheld radio Bronang WHP and Belanak
FPSO via UHF Repeater at Bronang WHP.

Acceptance
Result
NO Item Activity Description
PASS FAIL

Communication Between UHF Check that Radio Handheld can communicate using
1
Handheld Radio in Bronang WHP Repeater in Bronang WHP

Communication UHF Radio


Check that Radio Handheld in Bronang WHP can
Between Handheld in Bronang
2 communicate with Base Station radio in Belanak
WHP to Base Station Belanak
FPSO and vice versa
FPSO
0B

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 17 of 23

Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration


Test Procedure
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 1 of 13

1 POWER SUPPLY CHECK


The following steps are to power up the Telecom Panel and its respected equipment’s. Every time check
the incoming power of each component to ensure there are no bad power connection on components.
First of all, make sure that all breakers, fuses, or any protection devices are in OFF position.
1.1 FOREL WHP TELECOM PANEL 1 (86TAD-001) POWER SUPPLY CHECK

Acceptance
Measurement Result
NO Item Activity Description Objective
Result
PASS FAIL

• Check the presence of 24


VDC in TB Feeder 1 and 2
24 VDC Incoming (TB-24-F1 & TB-24-F2).
MCB-01 and MCB-02
Telecom Panel : • MCB-01 and MCB-02 in OFF
1 main circuit Breaker
• Feeder 1 Position.
function
• Feeder 2 Measure the load current of
incoming 24 VDC Feeder 1
and 2.
MCB-01 Activation of
2 Switch on MCB-01 & MCB-02
MCB-02 86-PSU-001
Measure the load current of
Distribution power to
3 TB-24-F3 incoming is 24 VDC, and
Telecom Panel 2
outgoing is 24 VDC
Measure the load current of
4 86-PSU-001 incoming is 24 VDC, and 86-PSU-001 Function
outgoing is 24 VDC

5 CB-01 Switch on CB-01 Activation of CONV-1

Measure the load current 24


6 CONV-1 VDC of incoming and outgoing CONV-1 Function
CONV-1
Activation of
7 CB-02 Switch on CB-02
86-TDC-001
8 CB-03 Switch on CB-03 Activation of CONV-2

Measure the load current 24 CONV-2 Function and


9 CONV-2 VDC for incoming and 48 VDC activation of
for outgoing CONV-2 86-TAQ-001A
10 CB-04 Switch on CB-04 Activation of CONV-3
Measure the load current 24 CONV-3 Function and
11 CONV-3 VDC for incoming and 48 VDC activation of
for outgoing CONV-3 86-TAQ-001B
The presence of 24
12 CB-05 Switch on CB-05 VDC on TB-CCTV-01,
TB 1 and 2
Activation of 86-TQN-
13 JBTE-3001 Closed TB-CCTV-01 no. 1
3001
The presence of 24
14 CB-06 Switch on CB-06 VDC on TB-CCTV-02,
TB 1 and 2
Activation of
15 JBTE-3002 Closed TB-CCTV-02 no. 1
86-TQN-3002
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 2 of 13

Acceptance
Measurement Result
NO Item Activity Description Objective
Result
PASS FAIL
The presence of 24
16 CB-07 Switch on CB-07 VDC on Input and
Output CB-07
The presence of 24
VDC on RLY-01 and
17 CB-08 Switch on CB-08
activation of
86-TPC-001

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 3 of 13

1.2 FOREL WHP TELECOM PANEL 2 (86TAD-002) POWER SUPPLY CHECK

Acceptance
Measurement Result
NO Item Activity Description Objective
Result
PASS FAIL
• Check the presence of 24 VDC
in TB Feeder TB-24-F3 no. 1 &
2 on Telecom Panel 1
24 VDC • 86TAD-001
MCB-01 main circuit
1 Incoming • Check the presence of 24 VDC
Breaker function
Feeder in TB Feeder (TB-24-F1)
• MCB-01 in OFF Position.
• Measure the load current of
incoming 24 VDC Feeder.

2 MCB-01 Switch on MCB-01 Activation of CONV-1

Measure the load current 24 VDC


3 CONV-1 CONV-1 Function
of incoming and outgoing CONV-1

Activation of
4 CB-01 Switch on CB-01
86-TDC-002
Activation of
5 CB-02 Switch on CB-02
86-TDC-003A
Activation of
6 CB-03 Switch on CB-03
86-TDC-003B
Activation of
7 CB-04 Switch on CB-04
86-TDC-004A
Activation of
8 CB-05 Switch on CB-05
86-TDC-004B
Activation of
9 CB-06 Switch on CB-06
86-TDC-005

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 4 of 13

1.3 BRONANG WHP TELECOM PANEL (86TAD-003) POWER SUPPLY CHECK

Acceptance
Measurement Result
NO Item Activity Description Objective
Result
PASS FAIL

• Check the presence of 24


VDC in TB Feeder 1 and 2
24 VDC Incoming (TB-24-F1 & TB-24-F2).
MCB-01 and MCB-02
Telecom Panel : • MCB-01 and MCB-02 in OFF
1 main circuit Breaker
• Feeder 1 Position.
function
• Feeder 2 Measure the load current of
incoming 24 VDC Feeder 1
and 2.
MCB-01 Activation of
2 Switch on MCB-01 & MCB-02
MCB-02 86-PSU-002
Measure the load current of
3 86-PSU-002 incoming is 24 VDC, and 86-PSU-002 Function
outgoing is 24 VDC

4 CB-01 Switch on CB-01 Activation of CONV-1

Measure the load current 24


5 CONV-1 VDC of incoming and outgoing CONV-1 Function
CONV-1
Activation of
6 CB-02 Switch on CB-02
86-TDC-006
7 CB-03 Switch on CB-03 Activation of CONV-2

Measure the load current 24 CONV-2 Function and


8 CONV-2 VDC for incoming and 48 VDC activation of
for outgoing CONV-2 86-TAQ-002A
9 CB-04 Switch on CB-04 Activation of CONV-3
Measure the load current 24 CONV-3 Function and
10 CONV-3 VDC for incoming and 48 VDC activation of
for outgoing CONV-3 86-TAQ-002B
The presence of 24
11 CB-05 Switch on CB-05 VDC on TB-CCTV-01,
TB 1 and 2
Activation of 86-TQN-
12 JBTE-4001 Closed TB-CCTV-01 no. 1
4001
The presence of 24
13 CB-06 Switch on CB-06 VDC on TB-CCTV-02,
TB 1 and 2
Activation of
14 JBTE-4002 Closed TB-CCTV-02 no. 1
86-TQN-4002
Activation of
15 CB-07 Switch on CB-07
86-TDC-007A
Activation of
16 CB-08 Switch on CB-08
86-TDC-007B
Activation of
17 CB-09 Switch on CB-09
86-TDC-008
The presence of 24
18 CB-10 Switch on CB-10 VDC on Input and
Output CB-10
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 5 of 13

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 6 of 13

1.4 BRONANG WHP UHF RADIO PANEL (86TAD-004) POWER SUPPLY CHECK

Acceptance
Measurement Result
NO Item Activity Description Objective
Result
PASS FAIL
• Check the presence of
24 VDC in TB Feeder
24 VDC (TB-24-F1).
Incoming • MCB-01 in OFF MCB-01 main circuit Breaker
1
UHF Panel : Position. function
• Feeder 1 • Measure the load
current of incoming 24
VDC TB Feeder
2 MCB-01 Switch on MCB-01 Activation of CONV-1
Measure the load current of
CONV-1 Function and
3 CONV-1 incoming is 24 VDC, and
activation of 86-TUZ-4001
outgoing is 24 VDC
Measure the load current of
4 86-TUZ-4001 incoming is 24 VDC, and Activation of 86-TUC-4001
outgoing is 12 VDC
0B

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 7 of 13

2 FUNCTIONAL TEST
This test is intended to verify local parameter of Telecom System equipments.
2.1 FOREL WHP TELECOM SYSTEM LOCAL PARAMETER
Acceptance
Result
NO Item Activity Description Objective
PASS FAIL

IP Address Check Int. Aux 10.80.32.2 / 255.255.255.240

ODU A Frequency 5.725 MHz


1
86-TAP-3001A Chanel Spacing 20 MHz

Link Name FR-BR-L1


IP Address Check Int. Aux 10.80.32.18 / 255.255.255.240

ODU B Frequency 5.825 MHz


0B 2
86-TAP-3001B Chanel Spacing 20 MHz
Link Name FR-BR-L2

VLAN 10 10.80.32.1 / 255.255.255.240

Router (Note 1 VLAN 20 10.80.32.17 / 255.255.255.240


3
86-TDC-001
VLAN 200 10.80.30.193 / 255.255.255.192
VLAN 100 10.80.30.1 / 255.255.255.128
CCTV Switch
4 VLAN 200 10.80.30.194 / 255.255.255.192
86-TDC-005
ICSS Switch A
5 VLAN 100 10.80.30.2 / 255.255.255.128
86-TDC-004A

ICSS Switch B
6 VLAN 100 10.80.30.3 / 255.255.255.128
86-TDC-004B
LAN/WAN
IP Address Check Interface
7 SWITCH 10.80.30.130 / 255.255.255.192
Management
86-TDC-002
DMZ SWITCH A IP Address Check Interface
8 10.80.30.131 / 255.255.255.192
86-TDC-003A Management

DMZ SWITCH B IP Address Check Interface


9 10.80.30.132 / 255.255.255.192
86-TDC-003B Management

PTZ Camera
10 IP Address Check 10.80.30.195 / 255.255.255.192
86-TQN-3001

Fixed Camera
11 IP Address Check 10.80.30.196 / 255.255.255.192
86-TQN-3002

VSAT MODEM IP Address Check Interface


12 10.80.30.129 / 255.255.255.192
86-TVC-001 Management

Note : 1. Layer 3 Switch with a premium license for routing protocol will be used instead of the Router due to
delivery time constraints.
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 8 of 13

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 9 of 13

2.2 BRONANG WHP TELECOM SYSTEM LOCAL PARAMETER


Acceptance
Result
NO Item Activity Description Objective
PASS FAIL

IP Address Check Int. Aux 10.80.32.3 / 255.255.255.240

ODU A Frequency 5.725 MHz


1
86-TAP-4001A Chanel Spacing 20 MHz

Link Name FR-BR-L1


IP Address Check Int. Aux 10.80.32.19 / 255.255.255.240

ODU B Frequency 5.825 MHz


0B 2
86-TAP-4001B Chanel Spacing 20 MHz
Link Name FR-BR-L2
VLAN 10 10.80.32.4 / 255.255.255.240

Router (Note 1) VLAN 20 10.80.32.20 / 255.255.255.240


3
86-TDC-006 VLAN 100 10.80.31.129 / 255.255.255.224
VLAN 200 10.80.31.1 / 255.255.255.224
CCTV Switch
4 VLAN 200 10.80.31.130 / 255.255.255.224
86-TDC-008
ICSS Switch A
5 VLAN 100 10.80.31.2 / 255.255.255.224
86-TDC-007A

ICSS Switch B
6 VLAN 100 10.80.31.3 / 255.255.255.224
86-TDC-007B

Fixed Camera 1
7 IP Address Check 10.80.31.131 / 255.255.255.224
86-TQN-4001

Fixed Camera 2
8 IP Address Check 10.80.31.132 / 255.255.255.224
86-TQN-4002

Note : 1. Layer 3 Switch with a premium license for routing protocol will be used instead of the Router due to
delivery time constraints.

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 10 of 13

2.3 BRONANG WHP – FOREL WHP AND FOREL FPSO END-TO-END COMMUNICATION TEST
This test is intended to verify Ping test for Integration Telecommunication System with expected result
“Replay” from destination. Make sure that all communication data traffics related to integration are up
and running.

Acceptance Result
NO Item Activity Description Objective
PASS FAIL
Test Ping to Destination IP

86-TDC-003A IP 10.80.30.131
DMZ Switch A Pass : Replay
1 86-TDC-003B IP 10.80.30.132
Forel FPSO Fail : RTO Request Time Out)
86-TVC-001 IP 10.80.30.129
86-TDC-003A IP 10.80.30.131
DMZ Switch B Pass : Replay
2 86-TDC-003B IP 10.80.30.132
Forel FPSO Fail : RTO Request Time Out)
86-TVC-001 IP 10.80.30.129

LAN/WAN Switch 86-TDC-002 IP 10.80.30.130 Pass : Replay


3
Forel FPSO 86-TVC-001 IP 10.80.30.129 Fail : RTO Request Time Out)

86-TDC-001 IP 10.80.30.1
86-TDC-004A IP 10.80.30.2

ICSS Switch A 86-TDC-004B IP 10.80.30.3 Pass : Replay


4
Forel FPSO 86-TDC-006 IP 10.80.31.1 Fail : RTO Request Time Out)

86-TDC-007A IP 10.80.31.2
86-TDC-007B IP 10.80.31.3
86-TDC-001 IP 10.80.30.1
86-TDC-004A IP 10.80.30.2

ICSS Switch B 86-TDC-004B IP 10.80.30.3 Pass : Replay


5
Forel FPSO 86-TDC-006 IP 10.80.31.1 Fail : RTO Request Time Out)

86-TDC-007A IP 10.80.31.2
86-TDC-007B IP 10.80.31.3
86-TDC-001 IP 10.80.30.193
86-TDC-005 IP 10.80.30.194
86-TQN-3001 IP 10.80.30.195

CCTV Switch 86-TQN-3002 IP 10.80.30.196 Pass : Replay


6
Forel FPSO 86-TDC-006 IP 10.80.31.129 Fail : RTO Request Time Out)

86-TDC-008 IP 10.80.31.130
86-TQN-4001 IP 10.80.30.131
86-TQN-4002 IP 10.80.30.132
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 11 of 13

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 12 of 13

2.4 BRONANG WHP – FOREL WHP FUNCTIONAL TEST


The test is intended to verify :
1. Active + Active configuration for Microwave Radio System
2. CCTV monitoring and function control
3. Bandwidth monitoring
4. BER/Ethernet test or link availability test on certain time and measure the available bandwidth.

Acceptance
NO Item Activity Description Result
PASS FAIL
Bronang WHP Telecom Check that all communication data traffics are up and
1
equipments running
Forel WHP Telecom Check that all communication data traffics are up and
2
equipments running
0B Check that the Active + Active of DMR communication
between Bronang WHP and Forel WHP is correct.
DMR Link A and B at Bronang
3 Simulate link failure between Link A and Link B by
WHP / Forel WHP
disconnecting Link A DMR and ensuring that Link B is
takes over the communication link and vice versa.
Open web browser and access the specified IP provided
CCTV monitoring via
for each Bronang WHP CCTVs. Check that 2 (two)
4 temporary laptop at Forel
CCTVs Bronang WHP could be monitored from
WHP
temporary laptop at Forel WHP via DMR communication.
Monitor and records bandwidth utilization via PRTG
software. Monitor bandwidth utilization on the following
devices:
• 86-TDC-001 (IP 10.80.30.1/25)
• 86-TDC-004A (IP 10.80.30.2/25)
Bandwidth Monitoring during • 86-TDC-004B (IP 10.80.30.3/25)
5
test integration • 86-TDC-005 (IP 10.80.30.194/26)
• 86-TDC-006 (IP 10.80.31.1/27)
• 86-TDC-007A (IP 10.80.30.31.2/27)
• 86-TDC-007B (IP 10.80.31.3/27)
• 86-TDC-008 (IP 10.80.31.130/27)

BER/Ethernet Test with Monitor and Record the following value for :
estimation 1 (one) hour for • Throughput
6 Link A DMR and Link B DMR • Latency
on Forel WHP and Bronang • Frame Loss
WHP. Ensure the overall test result are “PASS”

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Integration Telecom System Procedure with FPSO Telecom System
Appendix B – Bronang WHP – Forel WHP and Forel FPSO Integration Test Procedure Page 13 of 13

2.5 BRONANG WHP – FOREL WHP AND FOREL FPSO UHF RADIO COMMUNICATION TEST
The test is intended to verify communication between UHF handheld radio Bronang WHP, Forel WHP
and Forel FPSO.

Acceptance
Result
NO Item Activity Description
PASS FAIL

Communication Between UHF Check that Radio Handheld can communicate using
1
Handheld Radio in Bronang WHP Repeater in Bronang WHP

Communication UHF Radio


Check that Radio Handheld in Bronang WHP can
Between Handheld in Bronang
2 communicate with radio Base Station in Forel FPSO
WHP to Base Station in Forel
and vice versa
0B
FPSO

REMARK :

Completed By Approved by Witnessed By


PT. JETEC Indonesia PT. Meindo Elang Indah Medco E&P Natuna Ltd.

Signature: Signature: Signature:

Name: Name: Name:


Date: Date: Date:
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 18 of 23

Appendix C – Certificate of Completion Bronang WHP – Belanak FPSO


CERTIFICATE OF COMPLETION
INTEGRATION TELECOM SYSTEM BRONANG WHP – BELANAK FPSO FOR
TELECOM SYSTEM EPCI OF WELLHEAD PLATFORMS AND PIPELINE FOR FOREL
BRONANG PROJECT

THE UNDERSIGNED HAS INSPECTED AND WITNESSED THE TESTS WITHIN THIS PROCEDURE
(PROJECT DOCUMENT ID-F-FT-P-TD001-A08-00001) AND ITS APPENDICES.

THE UNDERSIGNED ACCEPTS THAT THE SYSTEMS HAVE BEEN TESTED TO THE AGREED
PROCEDURES (PROJECT DOCUMENT ID-F-FT-P-TD001-A08-00001 AND ITS APPENDICES) AND
MEETS THE REQUIREMENTS OF THE CLIENT ORDER.

THE INTEGRATION TELECOM SYSTEM IS ATTENDED, WITNESSED, VERIFIED AND APPROVED BY


THE FOLLOWING REPRESENTATIVE(S):

PT. JETEC INDONESIA PT. MEINDO ELANG INDAH MEDCO E&P NATUNA
Representative Representative Representative

Name : Name : Name :

Position : Position : Position :

Date : Date : Date :

Signature : Signature : Signature :

Name : Name : Name :

Position : Position : Position :

Date : Date : Date :

Signature : Signature : Signature :

Name : Name : Name :

Position : Position : Position :

Date : Date : Date :

Signature : Signature : Signature :

Name : Name : Name :

Position : Position : Position :

Date : Date : Date :

Signature : Signature : Signature :


Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 19 of 23

Appendix D – Certificate of Completion Bronang WHP – Forel WHP -


Forel FPSO
CERTIFICATE OF COMPLETION
INTEGRATION TELECOM SYSTEM BRONANG WHP - FOREL WHP - FOREL FPSO
FOR
TELECOM SYSTEM EPCI OF WELLHEAD PLATFORMS AND PIPELINE FOR FOREL
BRONANG PROJECT

THE UNDERSIGNED HAS INSPECTED AND WITNESSED THE TESTS WITHIN THIS PROCEDURE
(PROJECT DOCUMENT ID-F-FT-P-TD001-A08-00001) AND ITS APPENDICES.

THE UNDERSIGNED ACCEPTS THAT THE SYSTEMS HAVE BEEN TESTED TO THE AGREED
PROCEDURES (PROJECT DOCUMENT ID-F-FT-P-TD001-A08-00001 AND ITS APPENDICES) AND MEETS
THE REQUIREMENTS OF THE CLIENT ORDER.

THE INTEGRATION TELECOM SYSTEM IS ATTENDED, WITNESSED, VERIFIED AND APPROVED BY THE
FOLLOWING REPRESENTATIVE(S):

PT. JETEC INDONESIA PT. MEINDO ELANG INDAH MEDCO E&P NATUNA
Representative Representative Representative

Name : Name : Name :

Position : Position : Position :

Date : Date : Date :

Signature : Signature : Signature :

Name : Name : Name :

Position : Position : Position :

Date : Date : Date :

Signature : Signature : Signature :

Name : Name : Name :

Position : Position : Position :

Date : Date : Date :

Signature : Signature : Signature :

Name : Name : Name :

Position : Position : Position :

Date : Date : Date :

Signature : Signature : Signature :


Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 20 of 23

Appendix E – Job Safety Analysis (JSA)


Doc No:

DATE ISSUED:
JOB SAFETY ANALYSIS LAST REVIEWED DATE:

Job Description:
REVIEWED BY:
Area/Unit: Forel WHP, Bronang WHP and Belanak FPSO
(Name & Signature)
SUPERVISOR.
Tag No/Equipment Description:
(Name & Signature)
RESPONSIBLE PERSON:
References:
(Name & Signature)
PPE Required to do this Job: Yes Page: 1 of 2

Potential Hazard Risk Level before Control Statement Risk Level after
Job Step Potential Event Mitigation (H,M,L)
(Physical, Chemical, Biological, Mitigation
(C x L) (Required to reduce severity & likelihood)
Psychosocial, Ergonomic)

Work preparation 1. Psychosocial: Miscommunication 1. Miscommunication M (2x3) 1. Conducting toolbox meeting/Pre-Job Safety Meeting before L (2x1)
2. Physical: Mechanical, Gravity, 2. First Aid because of Pinch, doing work and delegating work according to competencies.
- PTW already been approved
Noise Slip, Trip & Fall 2. Work leader to ensure all team member understand with the
- Coordination with PROJECT &
OPS 3. Ergonomic: Mismatch, Awkward risk and its mitigation.
- Pre-Job Safety Meeting 3. Work leader must ensure all team member understand the
scope of work and its boundaries.
1. Psychosocial: Miscommunication 1. Miscommunication M (2x3) 4. Use
1. Competent
proper person.
PPE. L (1x2)
Material Preparation
2. Physical: Mechanical, Electricity, 2. First Aid because of Pinch, 5. Installing
2. Make surebarricade.
your hands and fingers are free from pinched point.
- Prepare Tools & Equipment at Site 6.
Weather. Slip, Trip & Fall. 3. Obtain
Proper weather forecast from Radio
body position/ergonomic Operator.
position
3. Ergonomic: Mismatch, Awkward 3. Pinch point. 4. Using full body harness at high location activities.
5. Make sure your hands and fingers are free from pinched point.
6. Housekeeping of the equipment must be maintained to prevent
the equipment from falling from a height and a tripping hazard.

Telecom System Operating 1. Psychosocial: Miscommunication 1. Miscommunication M (3x2) 1. Use proper PPE. L (2x1)
2. Physical: Electricity. 2. First Aid because of Pinch, 2. Installing barricade/sign at work activities.
- Check and identify the tag number
3. Ergonomic: Mismatch, Awkward Slip, Trip & Fall. 3. Activities done by in-charge and authorized personnel.
to be tested at Telecom Panels,
UHF Radio Panel, CCTV Junction 4. Pinch point. 3. Mechanical 4. Make sure your hands and fingers are free from pinched point.
Boxes and CCTV Washer 4. Trigger Alarm
- Installation of DMR Antennas, UHF
Antenna, ODU, LPU, Telecom
Panels, UHF Radio Panel, CCTV
Cameras, CCTV Junction Boxes
and CCTV Cameras.
- Operating of Data Network, DMR.
UHF Repeater and CCTVs.
Doc No:

DATE ISSUED:
JOB SAFETY ANALYSIS LAST REVIEWED DATE:

Job Description:
REVIEWED BY:
Area/Unit: Forel WHP, Bronang WHP and Belanak FPSO
(Name & Signature)
SUPERVISOR.
Tag No/Equipment Description:
(Name & Signature)
RESPONSIBLE PERSON:
References:
(Name & Signature)
PPE Required to do this Job: Yes Page: 2 of 2

Potential Hazard Risk Level before Control Statement Risk Level after
Job Step Potential Event Mitigation (H,M,L)
(Physical, Chemical, Biological, Mitigation
(C x L) (Required to reduce severity & likelihood)
Psychosocial, Ergonomic)

CCTV Workstation, NVR, joystick 1. Psychosocial: Miscommunication 1. Miscommunication M (3x2) 1. Use proper PPE. L (2x1)
and Monitor Operating 2. Physical: Electricity. 2. First Aid because of Pinch, 2. Installing barricade/sign at work activities.
3. Ergonomic: Mismatch, Awkward Slip, Trip & Fall. 3. Activities done by in-charge and authorized personnel.
- Check and identify the tag number
to be tested at CCTV Workstation, 4. Pinch point. 3. Mechanical 4. Make sure your hands and fingers are free from pinched point.
NVR, joystick and Monitor 4. Trigger Alarm
- Installation of CCTV Workstation,
NVR, joystick and Monitor.
- Operating of CCTV Workstation,
NVR joystick and Monitor.

Housekeeping 1. Psychosocial: Miscommunication 1. Miscommunication M (2x3) 1. Use proper PPE. L (1x2)


2. Physical: Mechanical, Gravity, 2. First Aid because of Pinch, 2. Waste segregation.
- Clear the cut/unused material from
Noise. Slip, Trip & Fall. 3. Sufficient rubbish bins shall be made available at each work
job location activities.
- Ensure there are no small 3. Ergonomic: Awkward position 3. Pinch point. area.
equipment or material on the floor. 4. Drop Object 4. All material or equipment to be stacked properly and secured.
- Restore remaining material and 5. Make sure your hands and fingers are free from pinched point.
keep save the equipment 6. Housekeeping of the equipment must be maintained to prevent
the equipment from falling from a height and a tripping hazard.

Revalidation by the Responsible Person is required prior to commencing the activity or the Work Leader has changed or if the method of work has changed significantly.

Responsible Person Name & Signature Date Responsible Person Name & Signature Date

Remarks: Example of Hazard:


• Physical: Machine, Electricity, Noise, Vibration, Heat, Radiation, Gravity, Temperature, Mechanical, Air/Water Pressure, Motion, Ground, Light, Weather, etc.
• Chemical: H2S, Mercury, Acid, Benzene, Toluene, Xylene, Gas/Hydraulic/Fuel Pressure, Liquid, etc.
• Biological: Virus, Snake, Germ, Microbe, Anthrax, Bacteria, etc.
• Psychosocial: Stress, Worker Phobias, Fatigue, etc.
• Ergonomic/Manual Handling: Mismatch, Awkward, Overreaching, etc.
Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 21 of 23

Appendix F – Livening Up Notice (LUN)


LIVENING - UP NOTICE (LUN)

LUN No : xx
System No :
Sub-System No :
Reference Drawing No :
(to be attached)

This System and Sub-System, including the following components and all associated cabling and control devices will
be energised,
Date : Time :

The energisation will not occur until relevant Mechanical Completion Acceptance Certificate (MC-SAC) is approved
relating to each piece of equipment to be livened up.

No equipment will be livened up unless a Permit is obtained and warning sign and barriers is installed.

System Components to be energised

No Tag Number Description Area


1 Forel WHP
2 Forel WHP
3 Forel WHP
4 Forel WHP
5 Forel WHP
6 Forel WHP
7 Forel WHP

Proposed By, Proposed By, Accepted By,


Lead Cons. and Precom, Topside Coordinator, Topside Coordinator,
MEPN - Project

(_________________) (_________________) (_________________)

Accepted By, Approved By, Approved By,


Commissioning Lead, MEPN - Operation MEPN - Operation
MEPN - Project

(_________________) (_________________) (_________________)


LIVENING - UP NOTICE (LUN)

LUN No : xx
System No :
Sub-System No :
Reference Drawing No :
(to be attached)

This System and Sub-System, including the following components and all associated cabling and control devices will
be energised,
Date : Time :

The energisation will not occur until relevant Mechanical Completion Acceptance Certificate (MC-SAC) is approved
relating to each piece of equipment to be livened up.

No equipment will be livened up unless a Permit is obtained and warning sign and barriers is installed.

System Components to be energised

No Tag Number Description Area


1 Bronang WHP
2 Bronang WHP
3 Bronang WHP
4 Bronang WHP
5 Bronang WHP
6 Bronang WHP
7 Bronang WHP

Proposed By, Proposed By, Accepted By,


Lead Cons. and Precom, Topside Coordinator, Topside Coordinator,
MEPN - Project

(_________________) (_________________) (_________________)

Accepted By, Approved By, Approved By,


Commissioning Lead, MEPN - Operation MEPN - Operation
MEPN - Project

(_________________) (_________________) (_________________)


LIVENING - UP NOTICE (LUN)

LUN No : xx
System No :
Sub-System No :
Reference Drawing No :
(to be attached)

This System and Sub-System, including the following components and all associated cabling and control devices will
be energised,
Date : Time :

The energisation will not occur until relevant Mechanical Completion Acceptance Certificate (MC-SAC) is approved
relating to each piece of equipment to be livened up.

No equipment will be livened up unless a Permit is obtained and warning sign and barriers is installed.

System Components to be energised

No Tag Number Description Area


1 Belanak FPSO
2 Belanak FPSO
3 Belanak FPSO
4 Belanak FPSO
5 Belanak FPSO
6 Belanak FPSO
7 Belanak FPSO

Proposed By, Proposed By, Accepted By,


Lead Cons. and Precom, Topside Coordinator, Topside Coordinator,
MEPN - Project

(_________________) (_________________) (_________________)

Accepted By, Approved By, Approved By,


Commissioning Lead, MEPN - Operation MEPN - Operation
MEPN - Project

(_________________) (_________________) (_________________)


Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 22 of 23

Appendix G – Bronang WHP – Belanak FPSO Integration Architecture


Project Procedure / Plans ID-F-FT-P-TD001-A08-00001 Rev. 0B
Integration Procedure of Telecom System WHP and FPSO
Medco E&P Natuna Ltd. Page 23 of 23

Appendix H – Bronang WHP – Forel WHP and Forel FPSO Integration


Architecture