You are on page 1of 1

+Y

0°/360°

50.0
Ø5 75.0
0
5.

Ø63

0.0
27

0
80
Ø6
) 202
175 1.4(
. 4(R3 1246.8 R3 1
202
1 5) 75)
(R317 ( R3175
1246.8 ) 22.500°
TBM BORING

67
50
DIRECTION

.5
A

00
.
67
) 77

°
75 4.6
31 ( R3 F
(R 1 B
4.6 75
77 ) -X +X
E 270° 90°
F AC 1452.2
R E

°
67.
TE 1138.8 C

500
0)
U (R290 (R290
O 1138.8

500
cd2 0) cd4 INNER FACE cd3

67.
de2 D

°
E 185 72

275.3

275.3
F AC 00
)
900
) 9.2( 0.4
R 29 . 2(R2 R 290 (R 67.500°
NE
0 .4( R 185
9 0) 290
IN 72 0) de4
cd4 cd2 cd1
OUTER FACE
R2 037

1454.2
90 .5
R
3

0.

R3
0

17
5.
0

-Y
SECTION B-B SECTION C-C 180°
SCALE: 1/20 SCALE: 1/20 VIEW TO TBM BORING
DIRECTION
1718
175) .9(R3
1 8.9(R3 1 75) RING LAYOUT
17 5) 1246.8
( R3 1 7 ( R3175 SCALE: NOT TO SCALE
1246.8 )

5) 47 TBM BORING
17 2 .1
R3 (R3
.1( CE 17 DIRECTION
2 FA 5)
47 R
TE
OU
de1 cd1 1424.7
0) 1138.8
CE (R290 (R290
FA 1138.8 0) INNER FACE
ER
INN 00) 1557 418
00)

275.0

275.0
29 .3(
de3 3(R 7 .1 (R29 .1(R2
900) R2
900 cd3
4 1 8 . 155 )
R2

OUTER FACE
90
R3

0.
03

1427.0
R3

0
7.
17

5
5.
0

SECTION A-A SECTION D-D


SCALE: 1/20 SCALE: 1/20

C D E

2021.4(R3175) 2021.4(R3175) TBM BORING


774.6(R3175) 1246.8(R3175) 1246.8(R3175) 774.6(R3175) DIRECTION
1859.2(R2900) 1859.2(R2900)
720.4(R2900) 1138.8(R2900) 1138.8(R2900) 720.4(R2900)

cd2 cd4 de4 de2


B 1452.2
B
de3 INNER FACE de4

275.3

275.3
+Z
1422.4(R3175)

1420.5(R2900)

1420.5(R2900)

1422.4(R3175)

TBM BORING de1 de2


"C" "E" OUTER FACE
DIRECTION
1454.2

-Z
SECTION E-E
SCALE: 1/20
A A
cd1 cd3 de3 de1
418.3(R2900) 1138.8(R2900) 1138.8(R2900) 418.3(R2900)
1557.1(R2900) 1557.1(R2900)

472.1(R3175) 1246.8(R3175) 1246.8(R3175) 472.1(R3175)


1718.9(R3175) 1718.9(R3175)

C D E

SEGMENT GEOMETRY D
(PROJECTED VIEW)
SCALE: 1/20

REFERENCE DRAWING / NOTES REVISIONS NO OBJECTION FROM CMRL LEAD DESIGN DETAIL DESIGN CONSULTANT CLIENT PACKAGE NO

NOTES:
The design and drawings as certified and submitted by the designer have been reviewed and proof checked.
CHECKER CERTIFICATION
P2C4/04
No Objection No Objection subjected to Revision and Resubmission Required
1. DIMENSIONS IN mm. comments as noted subjected to comments as noted DRAWING TITLE DRG.ISSUE RECORD STATUS
2. PRECAST CONCRETE SEGMENTS WILL BE DESIGNED TO CONFORM WITH INDIAN STANDARD IS-456:2000.
3. PROPOSED TAPER (27 mm) FULFILLS MINIMUM CURVE RADIUS ALIGNMENT OF 80% OF 205 m EQUAL TO
CHECKED BY REVIEWED BY APPROVED BY DATE Concept Design
164 m.
4. CONCRETE COMPRESSIVE STRENGTH OF 150 mm CUBE AT 28 DAYS WILL BE 50 MPa.
5. GUIDING RODS, PLASTIC CONNECTORS AND SELAING GASKETS WILL BE CHOOSEN ACCORDING TO
TUNNEL Preliminary Design
APPLICABLE SPECIFICATIONS AND CALCULATION.
6. ANCHORED GASKET WILL BE VERIFIED IN ORDER TO FULFILL SPECIFICATIONS REQUIREMENTS ENSURING PROJECT TITLE Segmental Lining - Geometry Segment D Definitive Design
WATERTIGHTNESS.
7. LINING ASSEMBLY AND OTHER DEVICES WILL BE VERIFIED IN FURTHER STAGES OF DESIGN.
By Detail Design Consultant Construction Reference X
8. THIS PROPOSAL IS FOR TENDER PURPOSE, NOT FOR CONSTRUCTION. Chennai Metro Rail Detail Design Consultancy SHEET 04 OF 06
9. THIS RING IS PROPOSED TO BE INSTALLED ALONG STRAIGTH PARTS OF THE ALIGNMENT AND ALONG
CURVES WITH RADIUS EQUAL AND HIGUER THAN 205 m. DESIGNED BY CHECKED BY APPROVED BY DATE Corridor-4,Phase-2 Good for Construction
10. ALL SEGMENTAL LINING COMPONENTS WILL BE DESIGNED FOR A MINIMUM SERVICE LIFE OF 120 YEARS. for the works and Services of the Detailed Design and Drawings for the Alignment,
A 18.01.2022 DMC ISSUED FOR APPROVAL AM RN Civil,Structural,Architectural, MEP,TVS,VAC & Track Works Covering the Alignment and DRAWING NUMBER SCALE REV
Underground Stations from Lighthouse to Meenakshi college in Corridor 4 of phase-II of
REV DATE BY DESCRIPTIONS CHEKD APPD
DMC AM RN 18.01.2022 Chennai Metro Rail Project. P20C40UG02PRW-MMSO-CIVTUNDWG-02404(A) INDICATED A