KS5
USER’S MANUAL
Contents
1 APPLICATION ........................................................................................................................... 2
2 METER SET............................................................................................................................... 2
3 BASIC REQUIREMENTS, OPERATIONAL SAFETY.................................................................. 3
4 INSTALLATION .......................................................................................................................... 3
5 DESCRIPTION OF THE INSTRUMENT ..................................................................................... 4
5.1 Voltage inputs ................................................................................................................... 4
5.2 External connections diagram ........................................................................................... 4
6 KS5 PROGRAMMING ................................................................................................................ 6
6.1 General description ........................................................................................................... 6
6.2 Starting operation .............................................................................................................. 9
7 CONFIGURATION OF THE METER .......................................................................................... 9
PARAMETERS.................................................................................................................................. 9
7.1 Measurement .................................................................................................................. 11
7.2 Parameters ..................................................................................................................... 11
7.3 Relays ............................................................................................................................. 13
7.4 Ethernet ......................................................................................................................... 15
7.5 Modbus ........................................................................................................................... 16
7.6 Settings ........................................................................................................................... 17
7.7 Information ...................................................................................................................... 17
8 SERIAL INTERFACES ............................................................................................................. 18
8.1 RS485 INTERFACE – the list of parameters ................................................................... 18
8.2 Examples of registers reading and saving ....................................................................... 18
8.3 Ethernet 10/100-BASE-T ................................................................................................. 21
8.3.1 Connection of 10/100 BASE-T interface ................................................................... 22
8.3.2 Web Server .............................................................................................................. 23
8.3.3 Modbus TCP/IP ........................................................................................................ 25
9 MAP OF REGISTERS OF KS5 METER ................................................................................... 25
10 FIRMWARE UPGRADE ........................................................................................................... 30
11 ERROR CODES....................................................................................................................... 31
12 TECHNICAL DATA .................................................................................................................. 31
13 ORDERING CODES ................................................................................................................ 34
KS5-09A User's manual 2
1 APPLICATION
The KS5 digital synchronizing unit has been designed for the synchronization of
generators switched for parallel operation with the grid or with other generators with rated
frequency of 50 or 60 Hz. Frequency differences, voltage values, and phase shifts are shown
on a 3.5“ color TFT display screen with a resolution of 320 x 240 pixels.
Bar graphs with zero in the middle marked f and δU indicate respectively the difference in
frequency and the difference in voltage values of the generator and network signals. Phase
shift φ of the generator and network voltage signals is indicated by a circular
synchronoscope. The spin speed corresponds to the difference between the network and the
generator frequency.
The synchronization point, i.e. the moment when the frequency, voltage and phase values of
the generator and the network are equal, is indicated by green indicators on the bar graphs
and inside the circle. With proper control of the BLK and START signals (detailed in p.7.3),
the SYNC synchronization relay will be activated.
The values of the measured quantities and deviations can be transferred to the master
system via RS485 interface or Ethernet.
The synchronizing unit has a galvanic separation between the individual blocks of:
- power supply,
- voltage inputs,
- Input control signals,
- RS485 Interface,
- Ethernet Interface:
- relay outputs
2 METER SET
Complete set of the Analyzer includes:
1. KS5 synchronizing unit 1 pc.
2. gasket 1 pc.
3. mounting brackets to fix the device in the panel 4 pcs.
4. connector with 16 screw terminals 1 pc.
5. connector with 14 screw terminals 1 pc.
KS5-09A User's manual 3
Safety instructions:
● The meter installation and connection should be made by qualified personnel.
All available protection requirements must be taken into consideration.
● Prior to turning the meter on verify the connections.
● Prior to removing the meter housing, always turn the supply off and disconnect the
measurement circuits.
● Removal of the meter housing during the warranty period voids the warranty.
● The synchronizing unit meets the requirements for electromagnetic compatibility in
industrial environment.
● A switch or a circuit-breaker should be installed inside the building or facility. It should
be located near the device, easily accessible to the operator, and suitably marked.
4 INSTALLATION
The synchronizing unit is adapted to be fixed to the panel by means of mounting brackets,
according to fig. 1. The housing is made of self-extinguishing plastic.
Housing dimensions 96 x 96 x 77 mm, mounting hole dimensions 92.5 x 92.5 mm. Outside the
meter there are screw terminals that allow connection of external wires with a cross-section up
to 2.5 mm2.
Ethernet
(Option)
Ethernet
(Option)
6 KS5 PROGRAMMING
6.1 General description
The spin speed and direction correspond to the difference between the network and the
generator frequency.
The values of measured parameters are presented on the next pages selected by pressing
the following buttons: (next page ) or (previous page).
Meter buttons can perform various functions depending on the operating location. Functions
are described on the bar at the bottom of the screen. If no description is present, it means that
the button is inactive at that moment.
The top of the screen shows the status of the relay outputs (SYNC, AL ),the status of
control input signals START, BLK, the Ethernet connection symbol , indicators of
receipt and transmit of the date at RS485 ( RX, TX )
KS5-09A User's manual 9
Exit
Return to normal operation by pressing the button
DHCP Mode IP Address Subnet Mask Gateway DNS Address MAC Address
Address
Addresse Deact. Auto 00.000.000.000 255.255.255.000 000.000.000.000 008.008.008.008 aa.bb.cc.00:21:01
s Act. 10Mb/s
100Mb/s Acquired from DHCP or entered manually when DHCP is
deactivated.
Ethernet
Port
WWW
00080
7.1 Measurement
Measurement – normal meter operation. Values of quantities characterizing the state and
the course of the synchronization process of the generator are displayed and signaled. The
KS5 meter performs voltage measurement functions (voltage difference), frequency
(frequency difference), and phase shift between the voltage signals of the network and the
generator.
7.2 Parameters
In this group the parameters of the meter are set. To enter the Parameters group
press the button Menu for about 3 seconds and then using the button or
select Parameters and confirm with the button Select .
KS5-09A User's manual 12
Measurement
Menu button
min 3 sec.
Button
Buttons
Select
and
Select
Using the buttons we select a parameter and confirm it using the button Select .
Then using the buttons you can select the parameter characteristics or set the
desired parameter values, i.e. the decimal digit position can selected with the button or
, the value of the digit with the button or . The active position is indicated by the
cursor. The selected characteristic or value of the parameter should be confirmed by pressing
the button OK or canceled by pressing the button Cancel . To exit the Parameter
Esc
procedure press the button or wait for about 120 seconds. To exit the Menu of the
Exit
parameter selection press the button or wait for about 120 seconds.
Table 1
No. Parameter name Characteristic / Description Default
value value
1 Primary voltage of transformer 1 .. 1245183 V 100
2 Secondary voltage of transformer 0.1 .. 1000.0 100.0
3 Compensation of fixed phase shift 0.0°
−90.0° .. +90.0°
4 Default settings of parameters No, Yes No
When a parameter changes, it is checked whether the value is within the range. In case of
setting the value out of range, the value is set to the maximum value (when the value is too
high) or to the minimum value (when the value is too low).
To configure KS5 synchronizing unit you can also use the free eCon software
available at manufacturer’s website.
7.3 Relays
Select
Select Relays in the options and confirm by pressing the button .
Button
Select Buttons
and
Select
Buttons
and
Select
Table 2
No. Parameter name range Notes / description Default
value
1 Low value of voltage difference -δU -20.0 .. 0 [%] -0.5
2 High value of voltage difference δU 0 .. 20.0[%] δU = 100 (UG-US)/US [%] 0.5
15 10..100.0 [%] 10
16 Phase shift Δϕ ≥ 20.0 .. 360.0 [°] 20
17 Set defaults No No
yes
KS5-09A User's manual 15
c) SYNC relay not energized despite meeting d) SYNC relay not energized despite meeting
synchronization conditions (START signal synchronization conditions (BLK signal did not
blocked by BLK signal) change its status from "1" to "0")
Fig.14, Graphic illustration of BLK and START input signals control with SYNC
synchronization relay
7.4 Ethernet
Select
Select Ethernet group in the options and confirm selection using the button .
Table 3
No. Parameter name range Notes / description Default
value
1 DHCP Deact./Act. Enabling/disabling DHCP Deact.
client (the service of
automatic acquiring the
parameters of Ethernet
interface IP protocol of the
meter from external DHCP
servers located within the
same LAN network).
Address
2 Mode Auto, 10Mb/s, 100Mb/s Auto
es
3 IP Address 0.0.0.0...255.255.255.255 10.0.1.161 Acquired from -
4 Subnet Mask 0.0.0.0...255.255.255.255 255.0.0.1 DHCP or -
0.0.0.0...255.255.255.255 entered
5 Gateway Address 0.0.0.0 -
manually when
6 DNS Address 0.0.0.0...255.255.255.255 10.0.0.44 DHCP is -
deactivated.
7 MAC Address Aa:bb:cc:00:21:01 -
8 Address 1 ... 247 1
9 Modbus Port 80 … 32000 1
10 TCP Max. connection limit 1…4 1
11 Waiting time 10 .. 360 60s
12 WWW Port 80 ... 32000 80
7.5 Modbus
Select
Select Modbus group in the options and confirm by pressing the button .
Table 4
No. Parameter name Characteristic / value Description Default value
1 Address 1…247 Address on the Modbus 1
network.
2 Baudrate 4800 b/s, 9600 b/s, 19,2 kb/s, Baud rate 9600 b/s
38,4 kb/s, 57,6 kb/s, 115,2
kb/s
3 Mode RTU 8N2, RTU 8E1, RTU Transmission mode RTU 8N2
8O1, RTU 8N1
KS5-09A User's manual 17
7.6 Settings
Select Settings group in the options and confirm by pressing the button Select .
Table 5
No. Parameter name Characteristic / Description Default
value value
1 Password 0 ... 9999 0 – off 0
2 Language English, Polish, Deutsch Polish
3 Backlight level Minimum, Medium, Maximum
Maximum
4 Set defaults meter params. No, Yes No
7.7 Information
Select Information group in the options and confirm by pressing the button Select .
8 SERIAL INTERFACES
8.1 RS485 INTERFACE – the list of parameters
The implemented protocol is in accordance with the standard PI-MBUS-300 Rev G of Modicon
Company. The list of serial link parameters of KS5 meter:
● ID 0xDF
● meter address 1..247,
● baud rate 4.8, 9.6, 19.2, 38.4, 57.6, 115.2 kb/s,
● operation mode Modbus RTU,
● information unit 8N2, 8E1, 8O1, 8N1,
● maximum time to commence the response 600 ms,
● maximum number of read registers in one query
- 61 registers – 4 byte,
- 122 registers – 2 byte,
● implemented functions - 03, 04, 06, 16, 17,
- 03, 04 registers reading,
- 06 one register record
- 16 n - registers record,
- 17 device identification
Default settings: address 1, baud rate 9.6 kbit/s, RTU 8N2 mode,
Example 1 . Readout of 2 16-bit registers of integer type, starting with the register addressed
0FA0h (4000) - registers values 10, 100.
Request:
01 03 0F A0 00 02 C7 3D
Response:
Address of Number of Value from the register Value from register Checksum
the device Function bytes 0FA0 (4000) 0FA1 (4001) CRC
B1 B0 B1 B0
01 03 04 00 0A 00 64 E4 6F
KS5-09A User's manual 19
Request:
01 03 1B 58 00 04 C3 3E
Response:
Address Number Value from the Value from the Value from the Value from Check
of the Function of bytes register register register the register sum
device 1B58 (7000) 1B59 (7001) 1B5A (7002) 1B5B (7003) CRC
B3 B2 B1 B0 B3 B2 B1 B0
01 03 08 41 20 00 00 42 C8 00 00 E4 6F
Request:
01 03 17 70 00 04 4066
Response:
Address Number Value from the Value from Value from Value from Check
of the Function of bytes register the register the register the register sum
device 1770h(6000) 1770h(6000) 1772h(6002) 1772h(6002) CRC
B1 B0 B3 B2 B1 B0 B3 B2
01 03 08 00 00 41 20 00 00 42 C8 E4 6F
KS5-09A User's manual 20
Example 4 . Readout of 2 32-bit registers of integer type, starting with the register addressed
1D4Ch (7500)
- registers values 10, 100.
Request:
01 03 1D 4C 00 02 03 B0
Response:
Address Number Value from the register Value from register Check
of the Function of bytes 1D4C (7500) 1D4D (7501) sum
device CRC
B3 B2 B1 B0 B3 B2 B1 B0
01 03 08 41 20 00 00 42 C8 00 00 E4 6F
01 06 0F A0 02 1F CA 54
Response:
01 06 0F A0 02 1F CA 54
Example 6. Readout of 2 registers, starting with the register addressed 0FA3h (4003)
Request:
Address of Address Address No. of No. of Number Value for reg. 0FA3 Value for reg. 0FA4 Checksum
the device Function of reg.Hi of reg.Lo reg. Hi reg. Lo of bytes (4003) (4004) CRC
B1 B0 B1 B0
01 10 0F A3 00 02 04 00 14 07 D0 BB 9A
Response:
01 10 0F A3 00 02 B2 FE
Address Function Number ID Device Information field for device software version Checksum
of bytes state (e.g. ”KS5-1.00 b-1.06” - KS5 device (CRC)
with software version 1.00 and bootloader
version 1.06)
01 11 19 CF FF 4E 34 33 20 2D 31 2E 30 30 20 20 20 20 20 20 E0 24
20 62 2D 31 2E 30 36 20
serial interface. Then the approval of changes is required by entering value “1” to the register
4149. After the changes are applied, the Ethernet interface is re-initialized according to the
new parameters - all Ethernet interface services will be restarted.
To access the Ethernet services, it is required to connect the meter to the network via the
RJ45 slot located at the rear / inside the panel part of the meter, operating in accordance
withTCP/IP protocol.
Description of RJ45 socket diodes function:
yellow LED - illuminates when the meter is properly connected to the Ethernet network
100 Base-T, does not light up when the meter is not connected to the network or is
connected to 10-Base-T network.
green LED - Tx/Rx illuminates when the meter sends and receives data, it flickers
irregularly, when no data is transmitted the diode lights up permanently
In order to connect the meter to the network the user should use twisted pair cable.
U/FTP – twisted pair cable with each pair foiled,
F/FTP – twisted pair cable with each pair foiled, additionally cable with foil shield,
S/FTP (formerly SFTP) – twisted pair cable with each pair foiled, additionally cable
with wire mesh shield,
SF/FTP (formerly S-STP) – twisted pair cable with each pair foiled, additionally with
foil and wire mesh shield,
Categories of twisted pair cable according to the European standard EN 50173 minimum:
Class D (category 5) - for high-speed local area networks, includes applications using the
frequency band up to 100 MHz. For Ethernet interface the user should use twisted pair cable
of STP type (shielded) category 5 with RJ-45 connector with conductors colors (in accordance
with the colors described in table 7) acc. to the following standard:
EIA/TIA 568A for both connectors at the so-called simple connection of KS5 to the
network hub or switch,
EIA/TIA 568A for the first connector and EIA/TIA 568B for the second connector at the
so-called patch cord connection (crossover) used, among others, when connecting
KS5 to the computer.
Table 7
Conductor Signal Conductor color acc. to standard
no.
EIA/TIA 568A EIA/TIA 568B
1 TX+ white-green white-orange
2 TX- green orange
3 RX+ white-orange white-green
4 EPWR+ blue blue
5 EPWR+ white-blue white-blue
KS5-09A User's manual 23
The access to the Web server is achieved by entering the meter IP address in the web
browser, e.g.: http://192.168.1.030 (where 192.168.1.030 is the set address of the
meter). The standard port for web server is port "80". Server port may be changed by
the user.
Caution: For proper website operation a browser with JavaScript enabled and
compatible with XHTML 1.0 is required (all popular browsers, Internet Explorer, version
8 minimum).
KS5-09A User's manual 24
Fig. 21. View of the synchronizing unit web server log window
Web server user names cannot be changed. However, it is possible to change the password
for each user - it is recommended to change passwords for security reasons. Password
change is only possible through the web page in "Ethernet” parameters group. Passwords can
have a maximum of 8 characters. If the password is lost - which will prevent you from using
KS5-09A User's manual 25
the web server, you must restore the Ethernet interface parameters e.g. from the menu:
Settings → Factory settings → Yes, or by entering a value of "1" in register 4152. All standard
parameters of the meter including the Ethernet parameters (according to Table 9) and user
passwords for WWW server will be restored:
user ”admin” → password: ”admin” ;
user ”user” → password ”pass”.
KS5 synchronizing unit allows access to internal registers via Ethernet and Modbus TCP/IP.
In order to set up a connection it is necessary to set a unique IP address for the meter and to
set the connection parameters listed in Table 8.
Table 8
Register Description Default value
4146 Device address for Modbus TCP/IP 1
4147 Port number of Modbus TCP 502
4145 Time to close the port of Modbus TCP/IP service [s] 60
4144 The maximum number of simultaneous connections to Modbus 4
TCP/IP service
The device address is the device address for Modbus TCP/IP protocol and is not the same as
the address value for Modbus RS485 protocol (Modbus Address 4100). By setting the "Device
Address for Modbus TCP/IP Protocol" parameter to "255", the meter will skip the address
analysis in the Modbus protocol frame (broadcast mode).
Table 9
Address
Value type Description
range
Value placed in one 16-bit register. Registers for the meter
Integer
4000 – 4053 configuration. Description of registers can be found in table 10.
(16 bits)
Registers for recording and reading.
Value placed in one 16-bit register. Registers of statuses,
Integer energy values, the meter MAC address, configuration data.
4400- 4420
(16 bits) Description of registers can be found in table 11. Read-only
registers.
Values placed in two successive 16-bit registers. Registers
Float
6000 – 6050 contain the same data as 32-bit registers of 7500 – 7530 range.
(2x16 bits)
Read-only registers. Byres order (1-0-3-2)
Float Values placed in a single 32-bit register. Description of registers
7500 – 7525 can be found in table 12. Read-only registers.
(32 bits)
Values placed in two successive 16-bit registers. Registers
Float
8000 - 8050 contain the same data as 32-bit registers of 7500 – 7525 range.
(2x16 bits)
Read-only registers. Byres order (3-2-1-0)
KS5-09A User's manual 26
Table 10
Address
Ope-
of the Range Description Default
rations
register
4000 RW 0…9999 Protection - password 0
4001 RW Reserved
4002 RW Reserved 0
4003 RW 0..18 Primary voltage of transformer, two older bytes 0
Primary voltage of transformer, two younger
4004 RW 0..65535 100
bytes
Secondary voltage of transformer x 10
1000
4005 RW 0..65535 500...1500 V (version 1)
or 2300
1500...4000 V (version 2)
SYNC relay - lower limit value of voltage
4006 RW -200 .. 0 [‰] -5
difference
SYNC relay - upper limit value of voltage
4007 RW 0 .. 200 [‰] 5
difference
Acceptable frequency difference when
4008 RW -300 .. 0 [%/100] -5
connecting "from below",
Acceptable frequency difference when
4009 RW 0 .. 300 [%/100] 5
connecting "from above",
4010 RW -900 .. 900 [°/10] Correction of combined voltages phase shift x 10 0.0
Permit to connect the generator “from below”
4011 RW 0.1 0 - No 1
1 - Yes
Permit to connect the generator “from above”
4012 RW 0.1 0 - No 1
1 - Yes
4013 RW 0 .. 200 [°/10] Acceptable phase shift x 10 20
4014 RW -999 .. 999 [ms] Lead/delay time of SYNC relay switching 0
Switching pulse
4015 RW 0.1 0 - permanent switching 0
1 - switching pulse
4016 RW 100 .. 999 [ms] Length of switching pulse 150
External lock
4017 RW 0.1 0 - No 1
1 - Yes
4018 RW 0.1 Deleting minimum and maximum values 0
4019 RW Reserved
4020 RW 200 .. 1000 [‰] AL relay - relative voltage difference ≥ 200
4021 RW 100 .. 1000 [‰] AL relay - relative frequency difference ≥ 100
4022 RW 200 .. 3600 [°/10] AL relay - phase shift x10 ≥ 200
4023 RW Reserved
4024 RW Reserved
4025 RW 1..247 Address on the Modbus network. 1
Transmission mode: 0->8n2, 1->8e1, 2->8o1, 3-
4026 RW 0..3 0
>8n1
Transmission speed: 0->4800, 1->9600
4027 RW 0..5 1
2->19200, 3->38400, 4->57600, 5->115200
4028 RW Reserved
4029 RW 0.1 Update the change of transmission parameters 0
4030 RW Reserved
4031 RW Reserved
49320
Third and second byte (B3.B2) of meter IP
4032 RW 0...65535 (0xC0A8 =
address, format IPv4: B3.B2.B1.B0
192.168)
4033 RW 0...65535 First and zero byte (B1.B0) of meter IP address, 356 (0x0164
KS5-09A User's manual 27
Table 11
Address
Ope-
of the Range Description Default
rations
register
4400 R Reserved
4401 R 0..65535 Identifier DF
4402 R 0..65535 Bootloader version x 100 -
4403 R 0..65535 Program version x100 -
4404 R Reserved
4405 R 0..65535 Ordering code -
1000
4406 R 0..65535 Nominal voltage x10
or 2300
4407 R Reserved
4408 R Reserved
4409 R Reserved
4410 R Reserved
4411 R Reserved
4412 R Reserved
Third and second byte (B3.B2) of serial
4413 R 0..65535
number, format B7:B6:B5:B4:B3:B2:B1:B0
First and zero byte (B1.B0) of serial
4414 R 0..65535 -
number, format B7:B6:B5:B4:B3:B2:B1:B0
4415 R 0..65535 Status register 1– description below -
4416 R 0..65535 Status register 2– description below -
4417 R Reserved
4418 R Reserved
4419 R Reserved
4420 R Reserved
Fifth and fourth byte (B5.B4) of meter MAC
4421 R 0...65535 -
address, format B5:B4:B3:B2:B1:B0
Third and second byte (B3.B2) of meter
4422 R 0...65535 -
MAC address, format B5:B4:B3:B2:B1:B0
First and zero byte (B1.B0) of meter MAC
4423 R 0...65535 -
address, format B5:B4:B3:B2:B1:B0
4424 R Reserved
Table 12
Address of
16-bit Address of
registers the register Operations Description Unit
2x16 1032/ 32 bits
2x16 3210
6000/8000 7500 R Network voltage US V
6002/8002 7501 R Generator voltage UG V
6004/8004 7502 R Network frequency fS Hz
6006/8006 7503 R Generator frequency fG Hz
6008/8008 7504 R Value of voltage difference δU %
6010/8010 7505 R Value of frequency difference δf %
6012/8012 7506 R Phase shift ϕ, range: 0..360 °
6014/8014 7507 R Phase shift ϕ, range: -180..+180 °
6016/8016 7508 R Reserved
6018/8018 7509 R Reserved
6020/8020 7510 R Reserved
6022/8022 7511 R Reserved
6024/8024 7512 R Reserved
6026/8026 7513 R Reserved
6028/8028 7514 R Reserved
6030/8030 7515 R Status register 1 -
6032/8032 7516 R Status register 2 -
6034/8034 7517 R Reserved
6036/8036 7518 R Reserved
6038/8038 7519 R Reserved
6040/8040 7520 R Voltage US min V
6042/8042 7521 R Voltage US max V
6044/8044 7522 R Voltage UG min V
6046/8046 7523 R Voltage UG max V
6048/8048 7524 R Frequency fS min Hz
6050/8050 7525 R Frequency fS max Hz
6052/8052 7526 R Frequency fG min Hz
6054/8054 7527 R Frequency fG max Hz
6056/8056 7528 R Value of voltage difference δUmin V
6058/8058 7529 R Value of voltage difference δUmax V
6060/8060 7530 R Value of frequency difference δf min %
6062/8062 7531 R Value of frequency difference δf max %
6064/8064 7532 R Reserved
6066/8066 7533 R Reserved
KS5-09A User's manual 30
10 FIRMWARE UPGRADE
KS5 meters have a feature that allows the user to upgrade the software using a PC with eCon
software. Free eCon software and update files are available at www.lume.com.pl. Software
update of the meter (firmware) can be performed via RS485 interface. The update is done in
LUMEL UPDATER tab.
a) b)
11 ERROR CODES
During operation of the meter, error messages may appear on the display. The causes of
the errors are listed below.
- Err bat – displayed when the battery of the internal RTC clock is worn. Battery
check is performed after powering. The message can be turned off with the button .
Disabled message remains inactive until the sync meter is turned on again;
- Err CAL, Err EE – displayed when the memory in the sync meter has been
damaged. The meter must be returned to the manufacturer.
- Err PAr – displayed when the operating parameters of the meter are incorrect.
Restore the factory settings (from the menu or via RS485). The message can
be turned off with the button .
- ∧ ∧ ∧ ∧ – upper overrun. The value is measured outside the measurement range.
- ∨ ∨ ∨ ∨ – lower overrun. The value is measured outside the measurement range.
12 TECHNICAL DATA
Measurement ranges and acceptable errors
Table 13
Measured quantity Measurement range Resolution Class / intrinsic error
Power consumption:
- in power supply circuit ≤ 6 VA
≤ 0.5 VA
- in voltage circuit
Readout field color graphic screen TFT 3.5” with resolution of 320 x 240
pixels
Relay outputs (AL, SYNC) 2 programmable relays, volt free NO contacts, resistive load
0.5 A/250 V a.c. or 5 A/30 V d.c.
Relay switching time 8 ms (max),
Number of switchings: mechanical minimum 5 × 10 6
electric minimum 1 x 10 5
KS5-09A User's manual 32
Terminals
Cross-section 0.05 .. 2.5 mm²
Clamping screws M3
Tightening torque 0.5 Nm
Degree of protection provided by housing
from the front side IP 65
from the panel side IP 20
Weight 0.3 kg
Dimensions 96 x 96 x 77 mm
Reference and rated operating conditions
- power supply 85..253 V a.c. (40..50..400) Hz or 90..300 V d.c.
or 20..40 V a.c. (40..50..400) Hz or 20..60 V d.c.
- input signal: 0,4..1,2Un
frequency 40..50 .. 60 ..100 Hz; sinusoidal ( THD ≤ 8% )
- phase shift 0 .. 360° or -180..+180o for frequency fn±5 Hz ( fn =50
or 60 Hz)
- ambient temperature -10..23..+55 °C, K55 class acc. to EN61557-12
- storage temperature -20..+70 °C
- humidity 0 .. 40 ..60 ..95 % (no condensation)
- acceptable crest factor :
- voltage 2
- external magnetic field ≤ 40...400 A/m d.c.
≤ 3 A/m a.c. 50/60 Hz
- short-term overload
voltage inputs 5 sec. 2 Un
- operation position any
- warm-up time 15 min.
Real-time clock battery: CR2032
KS5-09A User's manual 33
Additional errors:
in % of intrinsic error
- due to ambient temperature changes < 50 % / 10 °C
- for THD > 8% < 50 %
Standards met by the synchronizing unit
Electromagnetic compatibility
- immunity to interference in accordance with EN 61000-6-2
- noise emission acc. to EN 61000-6-4
Safety requirements:
according to PN-EN 61010-1 standard
● insulation between circuits: basic,
● installation category III for voltages up to 300V in relation to earth
● degree of pollution 2
● maximum operating voltage relative to earth
- for power and relay outputs circuits 300 V
- for measurement input 300 V
- for RS485, Ethernet circuits: 50 V
● altitude < 2000m
KS5-09A User's manual 34
13 ORDERING CODES
Ordering code for KS5 synchronizing unit
Table 14
Meter KS5 X X X XX X X
Input voltage Un*
50...150 V 1
150...400 V 2
Interfaces
RS485 1
RS485 and Ethernet 2
Power supply
85..253 V a.c., 90..300 V d.c. 1
20..40 V a.c., 20..60 V d.c. 2
Versions
standard 00
special** XX
Language
Polish P
English E
other** X
Acceptance tests:
without additional requirements 0
with quality inspection certificate 1
With calibration certificate 2
acc. to customer’s requirements** X
* Un - phase or phase-to-phase voltage (programmable in the selected range); maximum
operating voltage relative to earth 300 V,
*after agreement with the manufacturer
Export department:
tel.: (+48 68) 45 75 139, 45 75 233, 45 75 321, 45 75 386
fax.: (+48 68) 32 54 091
KS5-09A
60-006-00-00772