You are on page 1of 44

VOCAL FOR LOCAL

ABOUT US

ISO 9001:2015 company


recognised
“OPTIMIZING LIFE” Central
idea for product & solutions German Technology
development Transfer in India

India’s first fully


automatic wind-tunnel 20+ year’s worldwide proven
calibration facility product

MTS Engineers Pvt. Ltd Mr. Frank Mohns as a Technical


group promoted company advisor for product development.
LEOMI @GANDHINAGAR
GIDC,GUJARAT, INDIA

2
FACTORY
PREMISES
TEST &
CALIBRATION
SETUP

4
ABOUT US

Latest state-of-the-art facilities at Gandhinagar, Gujarat

5
INDIA’S FIRST IN-HOUSE FULLY CALIBRATION FACILITY

DAkkS Traceable Calibration Facility as per ISO17025


Velocity Ranges : 0.2 m/s to 75m/s
Flow Uniformity : ±0.2% 6
OUR SOLUTIONS

INSERTION TYPE FLANGE END


7
TECHNOLOGY ADVANCEMENTS AIR AND FLUEGAS FLOW MEASUREMENT

THERMAL MASS FLOW METERS WITH MANY ADVANCEMENT


PROVES TO BE
• LONG TERM PROVEN
• RUGGED DESIGNED
• AN ECONOMICAL
• RELIABLE TECHNOLOGY
• AGAINST DP TYPE FLOW METER SOLUTIONS

INSERTION TYPE
8
MEASUREMENT PRINCIPLE

WORKS ON KING’S LAW

• Constant temperature anemometry principle


• Higher the mass flowrate higher the cooling
effect of the heater sensor thus higher the
power required to maintain the differential
temperature constant.
• Heater power consumption is proportional to
mass flowrate

9
MEASUREMENT PRINCIPLE

Reference Heater
UH
Resistor RR Resistor RH = Power PH = U H  I H
IH

Linearization Linearization Calibration curve**


Pt100 = TR Pt100 = TH Output in Nm/s

Comparison Error Tdiff


TR = TH − TH + TR  TH − TH +

Conductivity
Compensation

Pipe Volume flow


Dimension Calculated in Nm³/h
LEOMI FLOW SENSOR

Density for air at Mass flow


norm conditions Calculated in kg/h
0°C und 1,01325bar = Volume x Density
= 1,293kg/m³
10
CURVES AFTER CALIBRATION @ DIFFERENT DELTA-T

11
THERMAL CONDUCITIVITY CORRECTION

12
LEOMI – INSERTION THERMAL MASS FLOWMETER

MAIN FEATURES :

• No Moving parts, Pt-100 RTD rugged sensor


• 100:1 Turndown ratio allow the leak detections
• Measuring mass flow rate independent of pressure and
temperature variations
• Programmable pipe diameters from 15mm & 10 mtrs
• Programmable for standard gas and gas mixtures
• Easy Installation & maintenance Leomi – 586 / 587

13
W/o. Safety head With Safety head
SENSOR PROBE GENERAL SPECIFICATIONS

Rugged stainless
steel & Alloy C276
Flow velocity range from
sensor probe
0.6 to 150 Nm/s

Working temperature
up to 420⁰C
Accuracy ±2% reading* or
better

16 bar(g) max. operating


pressure or higher on request
IP 67
protection

14
*Note: Accuracy overall temperature range
SENSOR GENERAL SPECIFICATIONS

HALAR COATED PROBES PFA COATED PROBES

• Can be used from 0-14pH corrosive gases • Can be used from 0-14pH corrosive gases
• Max. Operating Temperature up to 75⁰C • Max. Operating Temperature up to 175⁰C
• Abrasion resistance coating • Abrasion resistance coating

15
STANDARD FLOWRATE – TRANSMITTER : LEOMI-586

Enclosure : IP 65
Drift free digitally controlled
/ IP66 / IP67
heater temperature design

Communication: RS-232,
RS-485 Modbus RTU;
Ethernet; HART Compatible;
Profibus Terminal
Built-in thermal conductivity software pack
compensation of air with In-built
Large LCD display data-logging

Outputs : 4-20mA DC / 0-10VDC; 24VDC or 230VAC 16


Programmable Pulse or Relay (1 NO/NC)
power supply options
ACTUAL FLOWRATE – TRANSMITTER : LEOMI-587
Customized software available

measure Actual volumetric or


mass flowrate

Wet to Dry air correction


conversion possible

Data-logging with USB


stick of all parameters Terminal
Calculates Actual (Operating software pack
Flowrate of Compressed air with add on
Auto Purging Timer control or Combustion air or Flue gas board controller
for dusty application & logs all input given such as
pressure, power,
humidity(dew point) or other
Up to 4 analogue inputs
can be configured 17
VERSATILE SOFTWARE PROVIDES ALL PARAMETERS - DASHBOARD

18
LEOMI-586 INSTALLATION RECOMMENDATION

Recommended

Recommended for
high moisture pipes
X
19
LEOMI-586 INSTALLATION RECOMMENDATION

CIRCULAR SQUARE RECTANGULAR


PIPE DUCT DUCT

SUGGESTION FOR SIZES > 2 MTRS


20
LEOMI-586 INSTALLATION RECOMMENDATION

LARGE RECTANGULAR DUCT ( > 4MTRS)


MULTIPLE POINT MEASUREMENT SUGGESTION
21
LEOMI-586 INSTALLATION RECOMMENDATION

Flue gas or stack gas flows in large stacks more than 4 metres have a large volumetric flow rates

As per installation standards suggestion multiple thermal flow sensor can be Mounted 22
at equal distance in duct for achieving better accuracy.
LEOMI-586 INSTALLATION RECOMMENDATION

23
STRAIGHT LENGTH RECOMMENDATION

24
INSTALLATION IN PRESSURED LINE

Probe with Ball ½” Nipple & ½” Full Probe Insertion with safety chain
Valve Assembly port valve in pressurised pipe
25
LEOMI-586 SENSOR SURFACE INSERTION DEPTH CALCULATOR

26
LEOMI-586 GAS MIXTURE CALCULATOR

27
LEOMI-586 GAS VOLUME CALCULATOR

28
LEOMI-586 TERMINAL SOFTWARE

29
LEOMI 581 – INLINE THERMAL MASS FLOWMETER
MAIN FEATURES :

• No Moving parts, Pt-100 RTD rugged sensor


• Air / Gas Mass flowmeter independent of pressure and temperature.
• Meter sizes from DN 50 (2”) to DN150 (6”)
• Flow velocity ranges upto 120 Nm/s.
• Wide turndown ratio 100:1 allow the leak detections
• Accuracy better than +/-3% of reading
• Inline rugged stainless steel sensor and body in Aluminium and SS304.
• I/O plug-n-play connector
• Weather proof protection IP65
• Programmable for standard gas and gas mixtures
LEOMI 581

30
COMPARISON AGAINST OTHER FLOW TECHNOLOGIES

AEROFOIL (DP TYPE) AVERAGING PITOT/ ANNUBAR (DP TYPE)

INFRARED TIME CORRELATION

ULTRASONIC FLOWMETER
VORTEX TYPE 31
MAIN BENEFITS AGAINST OTHER FLOW TECHNOLOGIES
NO PRESSURE DROP : NO
CHANGE
• < 5mmwc across operating ranges IN
• Approx. 8 – 15 % power saving typically against DP & Vortex PIPE
DIAMETER

HIGHEST ACCURACY :
• Direct Mass Flow Measurement whereas DP, Vortex, Ultrasonic are Volumetric
• ±1.5% of reading better than most of DP Type & Ultrasonic flow meters having
±3% of reading

32
MAIN BENEFITS AGAINST OTHER FLOW TECHNOLOGIES

HIGHEST TURN-DOWN RATIO :


• Typically 100 : 1 Turn-down ratio proves to be most sensitive.
• Whereas DP Type 4:1; Vortex 10:1
• High measurement sensitive high signal resolution for fine analysis
than Orifice, Aerofoil, Pitot, Vortex & Ultrasonic.

LOW TOTEX ( TOTAL EXPENDITURE = CAPITAL + RECURRING ) COST :


• Installation needs < 1 hours with planned shutdown whereas
AEROFOIL needs around a day & more with installation cost.
• Virtually NO Maintenance as work same as Pt-100 Temperature
Sensor
• NO Shutdown required for preventive maintenance whereas Other
Vortex needs shutdown.
• Non contact flowmeter is high initial cost & with lower accuracy
33
MAIN BENEFITS AGAINST OTHER FLOW TECHNOLOGIES

CLEANABLE SENSORS :
• Can be cleaned by compressed air or by recommended liquid
solutions after removal from measuring stream for routine
maintenance & provides repeatable reading all the time.
• Whereas DP Type ports get clogging.

VERSATILE DESIGN :
• Insertion Type is adjustable & with programmable pipe diameters
whereas Inline type are for specified pipe size.
• Programmable gas other than air is possible

34
APPLICATIONS

VOCAL FOR LOCAL

35
SOME INSTALLATION

COMPRESSED AIR BIOGAS GAS NATURAL GAS


56
SOME INSTALLATION

HOT AIR HVAC HOT AIR AERATION AIR

57
SOME INSTALLATION

BLAST FURNACE GAS COMBUSTION AIR

58
SOME INSTALLATION

CORRISIVE TRACE GAS CHEMICAL VENT GAS BLAST FURNACE GAS

59
INSTALLATION IN WASTEWATER AERATION BASIN

60
SOME CUSTOMER REFERENCES

60
* Logo taken from Internet source for information only
CALIBRATION SERVICE

LEOMI provides Air Velocity calibration services for


other manufacturers of various type of Air Velocity
Instruments such as :

• Insertion Thermal Mass Flowmeter

• Hot-wire Anemometer

• Vane Anemometer

• S or L Type Pitot Tube etc.

61
QUESTIONS AND ANSWERS

62
VOCAL FOR LOCAL

• .

UP INSTRUMENTAÇÃO Ltda.
+55 19 3312 2900 / 9 7171 5241
mario@upinstrumentacao.com.br
www.upinstrumentacao.com.br

You might also like