You are on page 1of 25

RBS 6000 Family

WCDMA RAN System


Description and
RBS 6000 Survey

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 1 RBS 6601 Installation
LTE RAN Interfaces
External
External
Core Network Management
Management
System
System

Radio Access Mun


S1
Network
OSS-RC

Mun
Mul TEMS

X2
Network
Management
Uu
Environment
RBS
RBS RBS User Equipment

User Equipment

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 2 RBS 6601 Installation
RBS 6000 family

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 3 RBS 6601 Installation
RBS 6102

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 4 RBS 6601 Installation
RBS 6101

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 5 RBS 6601 Installation
RBS 6201

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 6 RBS 6601 Installation
RBS 6202

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 7 RBS 6601 Installation
RBS 6601

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 8 RBS 6601 Installation
RBS 6301

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 9 RBS 6601 Installation
RRUW/S 01

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 10 RBS 6601 Installation
RRUS 11

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 11 RBS 6601 Installation
RBS 6000 Unit Positions
143.5cm

Radio Units
GSM/WCDMA/LTE

Transmission
Module

Site Power

Cooling

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 12 RBS 6601 Installation
Comparison Between RBS
Families
Cabinet Vision

RBS 2206 RBS 2216 RBS 3206 RBS 3216

RBS 6201

RBS 3106 RBS 3116

RBS 2106 RBS 2116

RBS 6102 RBS 6101 RBS 3107

RBS 2308

RBS 3308 RBS 3418 RBS 3518

RBS 2111 RBS 6301 RBS 6601

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 14 RBS 6601 Installation
RBS 6000 Radio Modules
DPU

DPU
DC

DC

E1
1-2
E1
12
-
E1
3-4
E1
34
- Site
LAN
Site
LAN
EC

EC
GPS

GPS
Debu g
Sync
Debu g
Sync

F
O
F
I
O
I
TN lin k
Test
TN lin k
Test Sec
DPU
Sec
DPU
Eth
STM
-1
Eth
STM
-1
1
RU
GSM

1
RU
RU
2

RU
2
3
RU

3
RU
RU
4

RU
4
RU
5

RU
5
RU
6

RU
6

DUG 01 RUG DUG 02 RUS


DXU DRU E1/T1 2 TRX/SCPA IP 6 TRX/MCPA

DPU

DC DPU

DC

E1
WCDMA

1-2

E1
E1
1-2
3-4

E1
Site 3-4
LAN

Site
EC LAN

EC
GPS

Debu g GPS
Sync

Debu g
Sync
F
O
I F
O
TN lin k I
Test

Sec TN lin k
DPU Test

Sec
Eth DPU
STM-1

Eth
STM
-1
RU1

RU2 1
RU

RU3 RU
2

RU4 RU
3

RU5 RU
4

RU6 RU
5

RU
6

BB RU FU BB RUW DUW RUS DUS RUS

DPU

DC

E1
1-2

E1
3-4

Site
LAN
LTE

EC

GPS

Debu g
Sync

F
O
I

TN lin k
Test

Sec
DPU

Eth
STM
1
-

1
RU

RU
2

RU
3

RU
4

RU
5

RU
6

DUL RUS

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 15 RBS 6601 Installation
2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 16 RBS 6601 Installation
RBS 6201 Installation

RBS 6201
Technical Data

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 17 RBS 6601 Installation
Course Objective
At the end of this module, you will be able to:

 List the hardware units in the RBS 6201 and


RBS 6201 V2.

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 18 RBS 6601 Installation
RBS 6201
• Supports GSM, WCDMA and LTE
• Standard indoor RBS footprint
• Can be equipped with various Digital Units (DU)
and Radio Units (RU)
• Can be configured with up to 12 RUs and 2 DUs
(if width is 62mm) or 4 DU (if width is 31mm)
•4U Transmission spaces
• GPS
• External alarms
• Power consumption – 1.5 to 3 kW (configuration
dependent)

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 19 RBS 6601 Installation
Technical Data

Dimensions (in mm)


Height (w/ Base Frame) 1485
Width 600
Depth 483
Weight (in kg)
RBS fully equipped w/o 175 (w/ transmission, 190)
transmission equipment
Base Frame 12
Color
White Ref. No.: 1002-R

All measurements in mm

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 20 RBS 6601 Installation
Hardware Architecture
Based on a fully equipped cabinet, hardware units found
inside the RBS 6201 will depend on the RBS type, both
mandatory and optional.

RBS 6201 Types


•Control Base Unit (CBU)- based RBS
•Digital Unit (DU)-based RBS

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 21 RBS 6601 Installation
Hardware Architecture of 6201
RBS Overview for a CBU-based RBS
No.
Pos. Name of Units of Description
Units
Fan 3 Cools the RBS.
A

Support Connection 1 Controls the fans and supports the external EC-
B Unit (SCU) bus including power to the SAU.

C Power Connection 0–1 A DC or AC interface for the RBS.


Unit (PCU)

D Power Connection 0-1 Connects -48 V DC power from the site batteries
Filter (PCF) ʿ¹ʾ to the BFU. If internal BFU is used, PCF is
positioned on Dʿ²ʾ
E Radio Unit (RU) 1-6 Receives digital data and converts to analog
signal. Also, receives radio signal and converts to
digital signals.
F Power subrack containing the ff.: (for info. on unit locations in the power subrack, see
Non-RF Connections)

Power Distribution 1–2 Distributes -48 V DC power to the units in the


Unit (PDU) RBS.

Support Hub Unit 0–1 Connects peripheral units such as PSUs, PDUs,
(SHU) DUs and the SCU to the EC bus. Required if RBS
is equipped with PSUs.
Power Supply Unit 0-4 Converts incoming voltage to -48 V DC system
(PSU) voltage. Available for 120 – 250 V AC, +24 V DC,
-48 V DC and -60 V DC.

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 22 RBS 6601 Installation
Hardware Architecture (Cont.)
RBS Overview for a CBU-based RBS
No. of
Pos. Name of Units Description
Units

F Power Filter Unit 0 - 1ʿ³ʾ Mandatory for a -48 V DC powered RBS or an


(PFU) AC fed RBS with external battery backup.
Takes care of current ripple generated by RUs
on system voltage -48 V DC.
Power Connection 0-1 Connects -48 V DC power from the site to the
Filter (PCF) busbar.

Battery Fuse Unit 0-1 Supervises, connects and disconnects the


(BFU) battery backup. Can be installed internal or
external.
G Space for optional Space is 4 U high, 19” wide, extends 250mm
transmission behind and 50mm in front of the 19” mounting
equipment rails. There are 40mm spaces for cables at the
front and the rear. 400W is reserved in the
power consumption budget and 240W for heat
dissipation.
H Baseband cassette Contains the ff. boards: CBU (1), ET (0 – 4),
RAX (1 – 6), TX (1 – 2), RUIF (1)

I Connection Field 0-1 See Slide 36

(1) PCF 0202 is used for internal BFU.


(2) Depending on whether the BFU is internal or external, there are two types of PCFs (PCF
0201 and PCF 0202), the PCFs can be positioned in different locations of the RBS.
(3) One PFU can support up to six RUs.

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 23 RBS 6601 Installation
Hardware Architecture 6201 V2
Pos Name of Unit No. of Description
Units
A Fan 3-4 Cools the RBS

B Power Connection Filter 1 Connects external input -48 V DC power for


(PCF) supply to the RBS cabinet.
C Support Hub Unit (SHU) 0-1 Connects peripheral units such as PDUs and
the SCU to the DU.
D Support Control Unit (SCU) 1 Controls the fans and supports the external
EC-bus including power to the SAU.
Can act as a limited HUB in a -48 V DC two-
wire RBS, that is, no SHU is necessary.
E Power Distribution Unit 1-2 Distributes fused +48 V DC power to the units
(PDU) in the RBS.
F Radio Unit (RU) 1 - 12 Receives digital data and converts it to analog
signals. Also receives radio signals and
converts these to digital signals.
G Digital Unit (DU) 1-4 Provides switching, traffic management,
timing, baseband processing and radio
interface
H Power Filter Unit (PFU) 0-2 Stabilizes the -48 V DC system voltage in the
RBS.
I Cabinet busbar 1 Distributes power from the PCF to the PDUs
and the PFUs
J Space for optional -
transmission equipment

2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 24 RBS 6601 Installation
2/038 13-LZU 108 7975 Uen, Rev A © 2010 Ericsson AB 25 RBS 6601 Installation