You are on page 1of 4

RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEM

3264 W LAKEFIELD DR
MILWAUKEE, WI 53215
3.200 kW DC-STC / 3.800 kW AC +1 833 392 2887

26/MAY/22 208-888 DUPONT STREET


TORONTO, ON

+1 843-720-1844
1505 KING ST EXT #114,
CHARLESTON, SC 29405, USA
Digitally signed by David C. Hernandez
David C. Hernandez Date: 2022.05.26 16:30:04 -04:00
SHEET INDEX
C1 - COVER PAGE

N1 - GENERAL NOTES

S1 - SITE PLAN

S2 - PANEL LAYOUT

S3 - STRUCTURAL DETAIL

E1 - LINE DIAGRAM

E2 - WARNING LABELS

E3 - PLACARD

A1 - PANEL SPECIFICATIONS

A2 - RACKING SPECIFICATIONS

A3 - MOUNTING SPECIFICATIONS

A4 - INVERTER SPECIFICATIONS

A5 - OPTIMIZER SPECIFICATIONS

SYSTEM SPECIFICATIONS AHJ: CITY OF MILWAUKEE, WI


UTILITY: WISCONSIN ELECTRIC POWER CO ("WE ENERGIES")
SYSTEM SIZE: 3.200 kW GOVERNING CODE:
MODULE: HANWHA Q.PEAK DUO BLK ML-G10+ 400W WISCONSIN UNIFORM DWELLING CODE
NUMBER OF PANELS: 8 IBC 2015
INVERTER: SE3800H-US (240V) IRC 2015
OPTIMIZER: P401 IFC 2015
RACKING SYSTEM: IRONRIDGE XR-10-168M C1 - COVER PAGE
NEC 2017
GENERAL NOTES:

THE INSTALLATION OF PV SYSTEM SHALL BE IN ACCORDANCE WITH THE MOST RECENT


NATIONAL ELECTRICAL AND BUILDING CODES AND STANDARDS, AS AMENDED BY
JURISDICTION x WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE
x PV SYSTEMS SHALL BE PERMITTED TO SUPPLY A BUILDING OR OTHER STRUCTURE BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BUS BAR OF THE MAIN
IN ADDITION TO ANY OTHER ELECTRICAL SUPPLY SYSTEM(S) [NEC 690.4(A)] BREAKER.
x THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND x TO REDUCE FIRE HAZARDS, DC PV SYSTEMS WILL BE EQUIPPED WITH A GROUND
INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC FAULT PROTECTION SYSTEM IN ACCORDANCE WITH NEC 690.41(B)
690.4(C)] x WHERE GROUND-FAULT PROTECTION IS USED, THE OUTPUT OF AN INTERACTIVE
x EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATIONS INTAKE SYSTEM SHALL BE CONNECTED TO THE SUPPLY SIDE OF THE GROUND FAULT
AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM PROTECTION [NEC 705.32]
x INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC x ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL
PANELS, AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, AND CHARGE ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE
CONTROLLERS INTENDED FOR USE IN PV SYSTEMS SHALL BE LISTED OR FIELD PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV
LABELED FOR THE PV APPLICATION [NEC 690.4(B)] RESISTANT IF EXPOSED TO SUNLIGHT
x ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL x ALL THE NEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS SHALL BE
ROOF MOUNTED TRANSITION BOXES AND SWITCHES. POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY INSPECTIONS TO BE
x ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE PERFORMED BY THE BUILDING DEPARTMENT.
WITH NEC ARTICLE 250. x CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE
x SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41 READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO
x FOR PV MODULES, EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN 6AWG OPEN AND MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT
SHALL COMPLY WITH NEC 250.12(C) [NEC 690.46] INTERRUPTING". [NEC 690.33(C) & (E)(2)]
x ALL PV SYSTEM DC CIRCUIT AND INVERTER OUTPUT CONDUCTORS AND EQUIPMENT x FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS,
SHALL BE PROTECTED AGAINST OVERCURRENT UNLESS STATED OTHERWISE IN NEC LUGS, DEVICES, OR CONNECTORS IN ACCORDANCE WITH NEC 110.14
690.9(A) x WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER
x OVERCURRENT DEVICES USED IN PV SYSTEM DC CIRCUITS SHALL BE LISTED FOR NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3)
USE IN PV SYSTEMS [NEC 690.9(B)] x ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT AND
x PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID APPROVED FOR USE IN WET LOCATIONS PER NEC 314.15.
SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.12 x ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED,
x DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703
LOCATION OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)] x EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER
x ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND
x CONNECTORS SHALL REQUIRE A TOOL TO OPEN AND BE MARKED "DO NOT METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING
DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [NEC 690.33(E)] ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT
x ALL GROUNDED CONDUCTORS SHALL BE PROPERLY COLOR IDENTIFIED AS WHITE. IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING
[NEC 200.6] ELECTRODE.
x PV SYSTEM CONNECTED ON THE LOAD SIDE OF THE SERVICE DISCONNECTING x DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED "CAUTION DC
MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE CIRCUIT" OR EQUIV. EVERY 5 FT
PREMISES SHALL MEET THE FOLLOWING [NEC 705.12(B)]: x CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING
1. EACH SOURCE CONNECTION SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OF INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL
FUSIBLE DISCONNECTING MEANS. [NEC 705.12(B)(1)] RANGE.
2. 125 PERCENT OF THE POWER SOURCE OUTPUT CIRCUIT CURRENT SHALL BE USED x SERVING UTILITY TO BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM.
IN AMPACITY CALCULATIONS. [NEC 705.12(B)(2)] x ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR
3. EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER CONDUIT RUNS AS REQUIRED PER NEC.
TO A BUS BAR OR CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF x THE HOMEOWNER IS RESPONSIBLE FOR ENSURING ALL EQUIPMENT OUTSIDE THE
ALL SOURCES. [NEC 705.12(B)(3)] SCOPE OF WORK IS NEC COMPLIANT.
4. CIRCUIT BREAKER, IF BACK FED, SHALL BE SUITABLE FOR SUCH OPERATION
[NEC 705.12(B)(4)]

PROJECT: 3264 W LAKEFIELD DR


PALMETTO AUTHOR: EE N1 - GENERAL NOTES
MUNICIPALITY: MILWAUKEE, WI
PHONE: +1 843-720-1844 ZIP CODE: 53215 DATE: 26/MAY/22
CLIENT: RAUL ESQUIVEL HERNANDEZ
WWW.PALMETTO.COM REV: -
3.200 KW DC-STC / 3.800 KW AC
3264 W LAKEFIELD DR
SHED

E
N
LI
TY
R
PE (N) SERVICE POINT & UTILITY METERING (EXT)
O
PR (E) DISTRIBUTION PANEL (1F)
(N) PV METER (EXT)
(N) AC DISCONNECT (EXT)
3264 W LAKEFIELD DR
(N) INVERTER (EXT)
DWELLING

6'
-1
"

1 "
-2
2

3'
2" 2
1
1
1'-4
26

3
'-1
3 "
4

"
'-8
30
38
W

'-3
LA

1
"4
KE
FI
EL
D
D
R

SCALE: 1"=16'

NOTES: SAFETY PLAN: NEAREST URGENT CARE FACILITY


- SCALE AS SHOWN - INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME NAME:
- ALL DIMENSIONS IN FEET UNLESS - INSTALLERS SHALL UPDATE NAME, ADDRESS, AND PHONE NUMBER OF ADDRESS:
OTHERWISE STATED NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING PHONE NUMBER:

WORK
PROJECT: 3264 W LAKEFIELD DR
PALMETTO AUTHOR: EE S1 - SITE PLAN
MUNICIPALITY: MILWAUKEE, WI
PHONE: +1 843-720-1844 ZIP CODE: 53215 DATE: 26/MAY/22
CLIENT: RAUL ESQUIVEL HERNANDEZ
WWW.PALMETTO.COM REV: -
3.200 KW DC-STC / 3.800 KW AC
SITE INFORMATION PANELS DATA
NO. OF ARRAY AREA FRAME MAX ATTACHMENT Q CELL Q.PEAK DUO
ARRAY AZIMUTH PITCH ROOF TYPE ATTACHMENT FRAME SIZE & FRAME TYPE OVERHANG PANEL TYPE
PANELS (SQ. FT.) SPACING SPAN BLK ML-G10+ 400W
ROOF 1 136° 34° 6 127 COMPOSITE SHINGLE L MOUNT 2" X 4" RAFTERS 2'-0" 4'-0" 1'-4" NO. OF
8
PANELS
ROOF 2 316° 34° 2 42 COMPOSITE SHINGLE L MOUNT 2" X 4" RAFTERS 2'-0" 4'-0" 1'-4"
PANEL SIZE 74.0" X 41.1"
PANEL
48.5
WEIGHT
PANEL AREA 21.12
LEGEND UNIT WEIGHT
2.30

3'
OF AREA

(T
METER
MOUNTING PATTERN SAMPLE

RU
36" FIRE

E)
ACCESS PATH
.)

(T
YP

YP
36" FIRE ROOF 2
(T

.)
3'
VENTILATION

PVC VENT

MAX. 48"
METAL VENT
MAXIMUM MOUNT SPACING: 48"
MOUNT PATTERN: STAGGERED
VENT BOX
" 1 "
-8
1 2
-0 3'
2

STRUCTURAL 3' ALL HARDWARE, INCLUDING MOUNTING


DELIMITER AND RACKING, TO BE INSTALLED
PER MANUFACTURER SPECIFICATIONS.
SERVICE
MAST

SATELLITE

ANTENNA

1 "

'-4
SNOW GUARD 2

31
26

DOWNSPOUT
'-1

1 "
3 "

-0
2
4

ELECTRICAL 3'
MOUNT
ROOF 1
RAIL

TOP CHORD

SCALE: 1"=8'

NOTES:
TOTAL ROOF AREA: 906.26 FT² MODULE WATTAGE: 400 W
- SOLAR PANEL LAYOUT SUBJECT TO CHANGE ACCORDING TO EXISTING CONDITIONS
TOTAL ARRAY AREA: 168.96 FT² NUMBER OF PANELS: 8
- SCALE AS SHOWN
TOTAL ARRAY PERCENT COVERAGE: 18.66% SYSTEM SIZE: 3.200 kW
- ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED

PROJECT: 3264 W LAKEFIELD DR


PALMETTO AUTHOR: EE S2 - PANEL LAYOUT
MUNICIPALITY: MILWAUKEE, WI
PHONE: +1 843-720-1844 ZIP CODE: 53215 DATE: 26/MAY/22
CLIENT: RAUL ESQUIVEL HERNANDEZ
WWW.PALMETTO.COM REV: -
3.200 KW DC-STC / 3.800 KW AC