1. The pressure reducing valve (1) provides the remote “Load Sense Signal” to the "IN" port of the Main
Valve through the pilot control valve (2). This signal will increase the
pump discharge pressure to the level required by the operation of the pot 1
lock cylinders (6).
2. The flow from the main pump will be directed to the cylinders through
the isolation valve (3) and the check valve (10). PRESSURE REDUCING VALVE
(143956)
3. The relief valve (5) protects the piston side of the pot lock cylinders against over-pressurizing.
4 POT LOCK
402412 10 CONTROL MANIFOLD
190583
(190585)
12/12/11 1 FS190585_D
POT LOCK CYLINDERS
EXTEND TO LOCK
RETRACT TO UNLOCK
16
6
143956
5
PRESS. REDUCING 184529
PSI VALVE 8
(A) (B) (C) 224599
800 190569 190310 402412
1 1 GALLON
500PSI
190583 139173 7
190981
2 3 4 10 9
12/12/11 2 FS190585_D
POT LOCK SOLENOID ARRANGEMENT
Summary of General Operation
LOCKS ENGAGING
To engage the locks the Pot Lock Rocker Switch is toggled to the closed position (the straight line side of
switch pushed in).
At this point the following solenoids are energized: Lock Sol (A), Lock Sol (B).
Lock Sol (A) and Lock Sol (B) will remain energized until the pot lock limit switches make contact
indicating the locks are fully closed.
Lock Sol (C) remains de-energized until the Pot Lock Rocker Switch is toggled to the open position.
LOCKS DISENGAGING
To disengage the locks the Pot Lock Rocker Switch is toggled to the open position (the circle side of the
switch is pushed in).
At this point the following solenoids are energized: Lock Sol (A), Lock Sol (B), Lock Sol (C). Lock Sol
(A) and Lock Sol (B) remain energized for 10 seconds after the Pot Lock Rocker Switch is toggled to the
open position.
Lock Sol (C) remains energized until the Pot Lock Rocker Switch is toggled to the closed position.
In Summary: Lock Sol (A) & Lock Sol (B) allow extra flow from the main hydraulic circuit into the pot
lock hydraulic circuit to speed up the pot lock movements. Pot Lock Sol (C) controls whether the locks are
engaging or disengaging.
When commanding Pot Locks to Open IQAN digital input should be false. Physically, the rocker
switch should be shown with the circle part of the switch pushed in.
12/12/11 3 FS190585_D
LOCK ROCKER SWITCH SHOWING TRUE WHEN LOCKS COMMANDED TO DISENGAGE
If this is incorrect, the wiring between the IQAN system and the pot lock rocker switch is
incorrect.
LEFT LOCK LIMIT SWITCH & RIGHT LOCK LIMIT SWITCH (DIGITAL INPUTS MEASURE SCREEN)
The Left and Right Lock Limit Switches are digital inputs to the IQAN system that signals that
the pot locks are currently engaged. These are based on limit switches physically connected to
the lock structure on the tilt frame. When the locks are engaged, this should be True. When the
locks are disengaged, this should be False. If this is not the case, be sure to check the appropriate
Interlock Switch Setup procedure.
LEFT LOCK LIMIT SWITCH AND RIGHT LOCK LIMIT SWITCH WITH LOCKS ENGAGED
12/12/11 4 FS190585_D
LEFT LOCK LIMIT SWITCH AND RIGHT LOCK LIMIT SWITCH WITH LOCKS DISENGAGED
LOCK SOL (A) AND LOCK SOL (B) (CURRENT OUTPUTS MEASURE SCREEN)
These solenoids will always actuate at the same time. They operate together to allow more flow
to the pot lock extend / retract solenoids enabling faster operation of the pot locks.
When the pot locks are commanded closed, these solenoids will be on until the pot lock limit
switches read True meaning that the locks are fully closed.
When the pot locks are commanded open, these solenoids will be on for 10 seconds by default. If
adjusted, this could be set to anything between 1 second to 10 seconds. In order to adjust the time
these solenoids are on, go to the Pot Lock Retract Timer adjust screen and enter 2698. This should
NEVER be changed without first consulting the Electrical Engineering Department.
This solenoid controls the extend / retract motion of the pot locks. When the locks are
commanded closed (the Lock Rocker Switch Digital Input Reads True), this solenoid should be
de-energized. This ensures that when the machine is shut off, the locks will stay closed. When
the locks are commanded open, this solenoid should be energized.
12/12/11 5 FS190585_D
LOCK (A), (B), AND (C) SOLS FROM POT LOCKS ENGAGED TO DISENGAGED
12/12/11 6 FS190585_D
POT LOCKS DISENGAGED – STEADY STATE
LOCK (A), (B), AND (C) SOLS FROM POT LOCKS DISENGAGED TO ENGAGED
12/12/11 7 FS190585_D
POT LOCKS COMMANDED TO ENGAGE – TRANSIENT
(Will be in this state until Left Lock Limit Switch and Right Lock Limit Switch read True)
12/12/11 8 FS190585_D