• Precise and reliable system that delivers • Unattended operation of the FlashSmart EA: analyses
Lead the way in elemental analysis with accurate results can run 24/7 for complete results anytime, anywhere
a single instrument handling all applications. • Easy maintenance • Dedicated Thermo Scientific™ EagerSmart™ Data
Handling Software controlling all analytical
• Easy to use for reduced need for staff training
parameters, Thermo Scientific™ OxyTune™ Function,
You and your team can solve more laboratory challenges, improve workflow and minimize downtime. • Modern design combines simple user input with solid and liquid autosamplers, MVC Module and
The Thermo Scientific™ FlashSmart™ Elemental Analyzer (EA), based on the modified Dumas Method, is a dedicated software features FPD Detector
flexible solution that expands your CHNS/O analysis with over 20 configurations in one system. Powerful
software supports automated and precise reports, making everything easier for you and your team. • Better return on investment as the system is modular • Lower cost per analysis and greater productivity
and grows with your analytical requirements
Accurate
24/7 Determine Simple
automated 1 to 5 • Certified and uncompromised precision and
operation Elements
• Gas chromatographic method for real-time view of accuracy for a wide range of applications, from
the analytical process and pathway: anytime, anywhere research to routine analysis
• Streamlined sample preparation without the • Compliance with most recognized EA Official Methods:
need for dangerous chemicals as Kjeldahl Method AOAC, AOCS, AACC, ASTM, ASBC, ISO, EN, CEN,
MultiValve • Complete EA software for effortless operation: virtually EPA, IFFO
Kjeldahl Control the most complete EA dedicated software • OEA CookBook with thousands of determinations
alternative Module and methods for optimal results
for N/Protein for extended
capabilities Modular • IQ/OQ Qualification available
• Different autosamplers can be accepted on the • Robust, specially designed features that you can
1000 TOC same analyzer rely on for decades
Analysis Kit determinations
• Coupling capabilities with Flame Photometric • GC separation column operating for years without
for every configuration after acid
pretreatment Detector (FPD), for trace sulfur analysis, and with the need for replacement: it is not a consumable
in standard outfit
Isotope Ratio Mass Spectrometry (IRMS)
• 15-year warranty on combustion/reduction furnaces
Analyze from Furnaces and • Higher sample throughput and automation with and TCD detector
few ppm, TCD detector with
the Thermo Scientific™ MultiValve Control (MVC)
to 100% 15-year warranty* Module, without manual intervention
• Long term investment for your laboratory, which
guarantees reliability and accuracy of analysis
• Operates with helium and argon as carrier gas
2 *All furnaces and TCD except for furnaces used for HT. For more information, 3
contact your local Thermo Fisher Scientific Technical Representative.
Access more applications: become
MultiValve Control
the reference laboratory in your field Module for improved
productivity
No matter which direction you take, your lab and equipment will be able to adapt to support any strategy.
CHN/O MVC
CHNS/O MVC
Flexible systems enable you to react to the new, whilst delivering accurate and reproducible results.
CHN/CHN MVC
With the FlashSmart EA your lab can easily handle varying sample types, obtain from 1 to 5 element Material CHNS/CHNS MVC
determinations and achieve maximum sample throughput. Characterization Option to add the MVC Module
• Glue/resins to your customized
NC Soil Configuration • Papers FlashSmart EA
configuration.
Environmental Determination of Total
• Rubbers
CHNS/O Analyzer • Cement
• Soils, sediments, and rocks Nitrogen, Total Carbon,
Configuration • Ceramics
Organic Chemistry • Composts and Total Organic Carbon. • Carbon/Glass fibers
• Wastes
& Pharmaceuticals Perform 5 elements with TCD,
• Sewage/Sludge
• Tires
and trace sulfur determination • Pigments and dyes
• Fine chemicals
with the Flame Photometric
• Pesticides Agronomy & • Refractory materials
• Pharmaceuticals products • Water solution
• Organo-metallic compounds
Detector (FPD).
• Waste water
Marine Science • Building materials
• Inorganic materials
• Polymers • Particulates in air by filters • Soil N/Protein Analyzer
• Metals
• Plastic • Particulates in water by filters • Plants (leaves, roots, fruit) Configuration
• Synthetic rubbers Petro-chemistry • Woods • Sediments
• Textile fibers
• Wood powders
• Fibers & Energy • Humus Determine crude protein in
• Explosives • Algae human food and animal
• Coals
• Catalysts • Plankton feed using quality certified
• Cokes
• Textiles • Particulate matter Reference Material,
• Crude oils in water by filters
• Pesticides included as standard.
• Gasoline/Diesel • Water
• Detergents
• Alternative fuels • Fertilizer
• Fluorine-compounds
• Petroleum derivates
• Lubricants
Food Safety
• Oil additives • Human food and animal feed
• Graphite • Beverages (beer, juice,
milk, wine, soft drinks...)
• FlashSmart CHNS
• FlashSmart CHNS
• FlashSmart CHNS/O
• FlashSmart CHNS/O
• FlashSmart NCS
• FlashSmart N Org
• FlashSmart NC Soils
• FlashSmart NC Org
• FlashSmart NCS
NCS Analyzer • FlashSmart NC Soils
Configuration • FlashSmart N Org
• FlashSmart CHN
• FlashSmart CHN/O • FlashSmart NC Org CFR21 Validation
Achieve nitrogen, carbon
• FlashSmart CHNS • FlashSmart NCS
and sulfur determination by
• FlashSmart CHNS/O • FlashSmart NC Soils Required for the
• FlashSmart CHNS TCD detector and trace sulfur
pharmaceutical and • FlashSmart N/Protein
• FlashSmart CHNS/O determination with a flame
food safety industries. • FlashSmart N Brew
• FlashSmart N Lubricants photometric detector.
4 5
Performance that takes you further Software automates consistent
With powerful yet easy operation, your team can process more samples every day.
When you need to analyze more elements, you can adapt the FlashSmart EA on-site
sampling and reports
to your applications or add a second reactor to unlock more capabilities.
MultiValve Control Module: future-proof
Software
lab with more throughput and less costs
Instantly connect Carrier gas options The Thermo Scientific EagerSmart Data Handling By switching the analysis from the left channel to the
Software allows you to leave the FlashSmart EA right one (or viceversa), the MVC Module increases your
• Thermal Conductivity Detector • Helium unattended to get completed analysis, with full, analysis throughput. When the system is not in use
(TCD) user-friendly reports. The software controls all analytical overnight, on weekends, or for a prolonged period of
• Argon option for lower cost parameters, flows, autosamplers and detectors, time you can also reduce helium consumption and overall
• Flame Photometric Detector and regular supply by suggesting the most favourable analytical cost of analysis by switching from helium to nitrogen
(FPD) for trace sulfur analysis conditions for your samples. or argon.
• Switch to nitrogen or argon
• Isotope Ratio Mass Spectrometer when in Stand-By Mode • Automated transfer of the sample weight from • Fully automated and software controlled
(IRMS) the balance to the software
• No need to change hardware or software configuration
• Automated evaluation of Heat Values (Gross and
Gas chromatographic method: • Optional feature for extended lab throughput
Sample introduction modularity Net Heat Values) for fuels and alternative fuels
real-time analysis • Easy to add
• CO2 Emission Trade for environmental control
• Two solid autosamplers • Proper quantification of the five elements
• Different Protein Factors for food and animal feed
• Two liquid autosamplers • “Open window” function giving information
on what is happening inside the analyzer • Inserting of the Humidity value for solid samples
• One solid and one liquid autosampler and of the Density for liquid samples
in real-time
• One solid autosampler and one manual liquid sampler • Automated Minimal Formula determination for
• Straightforward and intuitive workflow
without valves pharmaceutical or fine chemicals applications
• No absorption or desorption of gases needed • Automated evaluation of C/N, C/H and C/S ratio