You are on page 1of 8

Split Air Conditioner In 

NOTIFICATIONS

Home Distribution and Conditioning Systems and Equipment and Components


Heating and ventilation and air circulation Cooling equipment and parts and accessories
Split Air Conditioner Including Green AC (V3) (Q2 Category)

Carrier 1.5 Ton, 5 Start AC


CarrierR
(CARRIER Split Air Conditioner 18k/
5 STAR INVERTER)

Rs. 85,000.00
TRENDS

Price For : 1 pieces

MRP/Unit: R.s 95,000.00


O�er Price/Unit: R.s 85,000.00

Availability: 900 In Stock

Min. Qty. Per Consignee: 100

Product id: 5116877-45401547274


Country Of Origin: India
Local Content (MII): 66%

Sold by: OEM

OEM veri�ed catalogue

VIEW SELLER DETAILS

4.0 - 4.49

Ask GeMmy
PRODUCT COMPARE PRODUCT HISTORY 2

1 of 8 15-Jun-23, 12:01 PM
Report

This

Product

Availability of BIS/ISI Mark : No


certi�cation

Air Conditioner Compliance : AC

BEE Star rating of the product : 5


(in Nos. ) (Central Ministries/
Departments while procuring
shall ensure that the items
carry 5 star (where annual
usages is expected > 1000
hrs),3 Star (where usage is
Limited)
VIEW ("0" Star Rating
MORE
means "Not Aplicable")

Ask GeMmy
PRODUCT COMPARE PRODUCT HISTORY 2

2 of 8 15-Jun-23, 12:01 PM
Special Terms & Conditions

Central Ministries/ Departments while procuring electrical appliances noti�ed by the Department
of Expenditure (DoE) shall ensure that they carry the noti�ed threshold or higher Star Rating of
the Bureau of Energy E�ciency (BEE). In this regard, DoE OM No.26/6/2012-PPD dated 21.01.2013
may also be referred to wherein appliances and threshold star ratings have been circulated.

STC FOR SPLIT AIR CONDITIONERS

Scope of installation and Commissioning for Ceiling Mount / Cassette AC

Mounting/Fitting of indoor and outdoor units at the respective locations after cutting the false
ceiling/drilling holes into the roof, if required.

Laying of refrigerant piping and connecting with indoor and outdoor units after drilling hole/holes
in the wall, if required.
Checking / Charging Refrigerant gas in the unit.

Suitable electric wiring between indoor units and switches up to 3 meters in length.

Testing for satisfactory working without any abnormal noise as well as leakage test of entire

The following are not included in the scope of supply for Ceiling Mount / Cassette AC:

Refrigerant pipe of the required length.


Set of 4 nos. of Rods for �xing Cassette AC to the roof.
Chiselling / Ducting / grooving for concealing the Refrigerant piping/cabling
Switches/ Sockets / Plug Tops / Voltage Stabilizer./ Stand for ODU/Drain pipe/Angles
Scope of installation and Commissioning for Floor Standing / Tower type Split AC
Mounting/Fitting of indoor and outdoor units at the respective locations.
Laying of refrigerant piping and connecting with indoor and outdoor units after drilling hole/holes
in the wall, if required.
Checking / Charging Refrigerant gas in the unit.
Suitable electric wiring between indoor units and switches up to 3 meters in length.
Testing for satisfactory working without any abnormal noise as well as leakage test of entire
The following are not included in the scope of supply for Floor Standing / Tower type Split AC
Refrigerant pipe of the required length.
Chiselling / Ducting / grooving for concealing the Refrigerant piping/cabling
Switches/ Sockets / Plug Tops / Voltage Stabilizer / Stand for ODU/Drain pipe/Angles
Scope of installation and Commissioning for Wall Mount / High wall Split AC
Mounting/Fitting of indoor and outdoor units at the respective locations.
Laying of refrigerant piping and connecting with indoor and outdoor units after drilling hole/holes
in the wall, if required.
Checking / Charging Refrigerant gas in the unit.
Suitable electric wiring between indoor units and switch upto 3 meters in length
Testing for satisfactory working without any abnormal noise as well as leakage test of the entire
system
The following are not included in the scope of supply for Wall Mount / High wall Split AC
Chiselling / Ducting / grooving for concealing the Refrigerant piping/cabling, Switches/ Sockets /
Plug Tops / Voltage Stabilizer/Stand for ODU/Drain pipe/Angles

Ask GeMmy
Standards
PRODUCT COMPARE PRODUCT HISTORY 2

3 of 8 15-Jun-23, 12:01 PM
Split Air Conditioner Conforming to IS:1391 (Part 2) latest

Availability of BIS/ISI No
Mark certi�cation

Air Conditioner AC
Compliance

BEE Star rating of the 5


product (in Nos. )
(Central Ministries/
Departments while
procuring shall ensure
that the items carry 5
star (where annual
usages is expected >
1000 hrs),3 Star (where
usage is Limited) ("0"
Star Rating means
"Not Aplicable")

BEE star rating plan as per Gazette Noti�cation No. S.O. 3897 (E) daated. 29th October 2019
and as per BEE Noti�cation dated 19th April 2022

Generic

Nominal Marketing 1.5


capacity as per BEE
Star Rating Label (hint:
1 Ton = 3000 Kcal/Hr,
Tolerance +/- 10%) (in
Ton)

Rated cooling capacity 3501 ≤ 5200


(in Watts) as per
IS:1391 (Part 2)

Technology of air Inverter AC - Variable Speed


conditioner

Unit Mounting Indoor Unit - Wall Mount type


Arrangement

ISEER (Wh/Wh) values Not applicable for Non Green AC


for compliance of
Green AC

Rated voltage (in Volts) 230 V, 1 Phase, 50 Hz, AC

Tolerance Value for 10% of rated Voltage


Rated Voltage
Ask GeMmy
PRODUCT COMPARE PRODUCT HISTORY 2

4 of 8 15-Jun-23, 12:01 PM
Refrigerants

Eco-friendly Yes
Refrigerant

Refrigerant R 32
designation

Refrigerant Global 675 (for R32)


warming potential
(GWP)

Refrigerant Ozone No
Depletion Potential is
Zero

Construction

Classi�cation by Cooling only (Cooling and dehumidi�cation during cooling mode)


function

Heating capacity (in Not applicable for Cooling only (Cooling and dehumidi�cation during
Watts) Hint:- Seller cooling mode)
should select matching
Heating Capacity Value
with respect to their
Nominal Marketing
Capacity in Tonnage)

Unit type Single split ( Single Indoor and Single outdoor)

Compressor Type Rotary Type

Additional Not Applicable


Requirement

Material

Material of Evaporator Copper

Material of Condenser Copper

Material of Air Filter Synthetic Fiber


(on indoor unit)

Reusable air �lter Yes

Ask GeMmy
GeneralCOMPARE
PRODUCT Feature PRODUCT HISTORY 2

5 of 8 15-Jun-23, 12:01 PM
AC Modes Turbo Mode,Dehumidi�cation Mode,Power Saving Mode,Auto Clean
Mode,Self Diagnosis Mode,Quiet Mode,Dry Mode,Eco saving,Convertible
for energy consumption,Swing,Timer,Smart diagnosis

Remote Control Timer,Fan Speed Control,On/OFF


Features

Additional Features Anti Bacteria Filter,Sleep mode,Auto O�,Auto Restart,Auto Air Swing

Environmental Feature

Noise level As per IS:1391 (Part 2) latest

Environmental Friendly Yes


Paint

Recycled Plastic <80% by weight of total plastic components in product


Components

Marking And Packing

Marking on the Split as per Cl.17.1.1 and as per Cl.17.1.2 of IS:1391 (part 2)
AC

Mode of packing Packed with Recycled and Biodegradable Material

Accessories

Supply cord and the 3 m (PVC Insulated sheathed cables as per IS:694)
interconnecting cord
between the indoor
and outdoor unit

Accessories / 3 m Cu connecting pipe (for Wall Mount type upto 2 Ton), Remote control,
Installation kit with 2 nos.of battery for each remote, Operating Manual, Installation Manual,
each split air No Installation kit
conditioner

Warranty

AC Machine warranty 5
(in Years)

Warranty on 10 (for Inverter AC upto including 2 Ton capacity)


Ask GeMmy
compressor (in Years)
PRODUCT COMPARE PRODUCT HISTORY 2

6 of 8 15-Jun-23, 12:01 PM
Installation

Installation Standard installation(Scope of installation as per STC attached) with


uninstallation of existing AC included

Not included in the As per STC attached


scope of supply

Certi�cation

Availability of type test Yes. As per IS:1391 (Part 2) latest


report from Govt Lab/
NABL accredited lab /
ILAC accredited lab to
prove conformity of
the speci�cation

Test report number NABL / T-5424 20.07.2022


and date (Must
declare)

Name and address of National Accreditation Board for Testing and Calibration Laboratories
Lab (Must declare)

Environmental Not applicable


Management
Certi�cation

Other certi�cation Not applicable

Agreed to furnish all Yes


the test reports and
certi�cates to buyer on
demand

ABOUT GeM

Introduction to GeM

Statistics

Right to Information
Ask GeMmy
Analytics
PRODUCT COMPARE PRODUCT HISTORY 2
New on GeM

7 of 8 15-Jun-23, 12:01 PM
WEB INFO BRAND GeM

Terms of Use
NEWS & EVENTS
Website Policies
Newsroom
Document Help
Gallery
Sitemap
Noti�cations
Web Information Manager
CCM Schedule

Forums

TESTIMONIALS

RESOURCES TRAINING

GeM Handbook LMS

OM’s/Circulars Training Calendar

Terms and Conditions Training Module

Policies/Manuals Facilitators

Miscellaneous Download GeM Logo

MOU'S
NEED HELP ?

FAQs

Feedback

Raise a Ticket

Contact Us

Careers

© 2021 GeM All rights reserved Site operated and maintained by Managed Service Provider

Ask GeMmy
PRODUCT COMPARE PRODUCT HISTORY 2

8 of 8 15-Jun-23, 12:01 PM

You might also like