You are on page 1of 3

HAZARDOUS AREA

GROUP IIB RCI-4100 DISPLAY


(DISRCI4100)
RCI-4100 CONTROL UNIT
(CUFRCI4100-3)
SAFE AREA
ZONE 1, ZONE 2
A D G J

C F I

B E H K
OVERRIDE KEYSWITCH

CABLE ENTRY POSITIONS REFER


NOTE 3

F
MAIN WINCH
GLAND 4 CORE SCREENED CABLE (BLUE)
TENSION CELL 10mT CHASSIS
(CELTPT10) (CABBSHLD4CBL) 10m
A AUX LOAD GLATWAB1M13 REFER NOTE 3
AUX WINCH DYNAMOMETER (WITH PLAS10TF/BUSHR1015 X 2) B
B MAIN LOAD GLATWAB1M13 (DYNHRT3SS)
4 CORE OFFSHORE CABLE 10.5mm (BLUE) I
20MM SHEAVES (SHEH32020)
C UNUSED PLUGM25E (CABBSHLD4CBL)
JUNCTION BOX EXe
60m CUSTOMER SUPPLY
(JUNBOX4320-4) 10-40VDC
D UNUSED PLUGM25E POWER INPUT
E UNUSED PLUGM25E 6 WAY
(CABLD5298-11MM)

F DISPLAY GLATWAB1M13
J
G UNUSED PLUGM25E 4 CORE OFFSHORE CABLE 10.5mm (BLUE)
(CABBSHLD4CBL) 50m CUSTOMER SUPPLY
H ANGLE GLATWAB1M16
A DIGITAL OUTPUTS
I POWER GLATWAB1M13
J DIGITAL OUTPUTS GLATWAB1M13 K
H
K DIGITAL INPUTS GLATWAB1M13 CUSTOMER SUPPLY
4 CORE OFFSHORE CABLE DIGITAL INPUTS
(CAB4COREOS) 15m NOTE:
ANGLE SENSOR
(ANGES4130) CABLES MUST COMPLY WITH
RELEVANT INSTALLATION
STANDARDS.

CHASSIS PEDESTAL
(NOT SUPPLIED
BY ROBWAY)

NOTE 1: CAUTION:
MANUFACTURER'S INSTRUCTIONS MUST BE FOLLOWED WHEN INSTALLING Ex d CABLE GLANDS. The apparatus must be installed in
STEEL WIRE ARMOUR MUST BE CAPTURED IN GLAND. accordance with the manufacturer's
NOTE 2:
instructions and with the relevant
UNUSED CABLE ENTRIES MUST BE BLOCKED OFF WITH APPROPRIATE Ex d PLUG.
NOTE 3: hazardous area installations
REFERENCE DOCUMENTS CHASSIS EARTH STRAPS MUST BE CONNECTED TO EQUIPOTENTIAL EARTH. standards/codes of practices.
Doc No. Document Title REV DATE DESCRIPTION OF CHANGE APPR'D DRAWN DATE PART OF ASSY CUSTOMER: PROJECT:
TOL: X. +/- 1 OFFSHORE KESUMA SO 140373
SAC0011 Simple Apparatus Assessment, Kelba KPA6140 A 2022-06-03 INITIAL RELEASE J.K. X.X
X.XX
+/- 0.2
AS STATED H.VOGELS 2022-05-20 - TITLE: SCALE
SAC0009 Simple Apparatus Assessment, Delphi Tension Cell Range 32 West Thebarton Rd
GA RCI4100 NAUTILUS 340LA-130 N/A
DRAFTING STANDARD: AS1100
SAF0004 Safety Analysis, D1063S, Delphi Transducers, 4 pair cable
THEBARTON SN 010004C TW HAZ SHEET
DO NOT SCALE DRAWING SOUTH AUSTRALIA 5031 1 OF 3
ALL DIMENSIONS ARE IN MILLIMETERS web : www.robway.com
SAF0019 Safety Analysis, D1063S, Kelba Beam Cell, 4-core HCX185 UNLESS OTHERWISE STATED PH: +61 8 8238 3500 DRAWING No: FILE No: REV
FX: +61 8 8352 1684 5990 5990-A.DWG A
V+
V-

P19
RELAY 1

RELAY 2

RELAY 3
CIRPCB4205 V+
V-

P2

CIRPCB4234
P10 P10 P10 P15
P5 P7 P13 P20 P16 P17 P18 P2 P3

EX3
EX1

EX2

G
G

A3+
A3-
A1+
A1-

A2+
A2-
P1

GND

GND
SDA

SDA

DI1-
DI1+

DI2-
DI2+

DI3-
DI3+

DI4-
DI4+

DI5-
DI5+

DI6-
DI6+

DI7-
DI7+

DI8-
DI8+
24V

24V

24V

24V

24V

24V

24V

24V

24V

24V

24V

24V

24V

24V

24V

24V
IO1
IO2
IO3
IO4
IO5
IO6
IO7
IO8

6V
24V
GND

GND

OD1

OD2

OD3

OD4

OD5

OD6

OD7

OD8
SCL

SCL

NO
NC

NO
NC

NO
NC
COM

COM

COM
6V

6V
-

+
BK
RD
GN
WH
CIRPCB4311

BK
RD
GN
WH

TXA+

TXB+
RXA+

RXB+
SHLD

SHLD
TXA-

TXB-
RXA-

RXB-
1 2 3 4 1 2 3 4

5 6 7 8 5 6 7 8
1 2 3 4 5 6 7 8

SDA
SCL

SUPPLY -
n/c
n/c
SUPPLY +
n/c

n/c
D1063S D1063S
OD1 OD2 OD3 OD4 OD5 OD6 OD7 OD8
BAREX4120
MAIN AUX
G A3 EV -3 -2 -1 +3 +2 +1 -6 -5 -4 +6 +5 +4 G R- T- 24V R+ T+ NC 1C NO NC 2C NO NC 3C NO

COM

COM

COM

COM

COM

COM

COM

COM
CIRPCB4162 CIRPCB4162-1
3 AMP
CIRPCB4163 ANTI-SURGE

SDA
SCL
EXCE-

n/c

n/c

n/c
n/c
0V
6V
EXC+

EXC+

NO

NO

NO

NO

NO

NO

NO

NO
NC

NC

NC

NC

NC

NC

NC

NC
EXC-
Sig+

Sig+

BU

BN
Sig-

Sig-

BK
9 10 11 12 13 14 15 16

RD

GN
WH
BK
J

WH
WH
GN

GN
RD
RD

BK
BK

I
A K
F H 10-40VDC
B SUPPLY +
SUPPLY -

CONSTANT TENSION (OD8)


PERSONNEL LIFT INDICATOR (OD7)
EXTERNAL AUDIBLE ALARM (OD6)
UNUSED (OD5)
ON/OFF BOARD INDICATOR (OD4)
UNUSED (OD3)
UNUSED (OD2)
6 WAY PLUG
RD BOOM UP M/CUT (OD1)
A + EXC
GN AUX HOOK ATB OVERHOIST (RL3)
F + SIG
WH
E - SIG
MAIN C - EXC
BK MAIN HOOK ATB OVERHOIST (RL2)
B - GENERAL MOTION CUT (RL1)
D -

RD RD

GN GN

WH WH

AUX BK BK

DISPLAY AUX WINCH DIRECTION (DI2)


MAIN WINCH DIRECTION (DI1)

RD EXC+ BOOM EARTH STRAP


BN

YE SIG BK
ANGLE SENSOR BOOM EQUIPOTENTIAL
(BOOM) BK GND
BU EARTH
GY

PART OF ASSY CUSTOMER: PROJECT:


REV DATE DESCRIPTION OF CHANGE APPR'D DRAWN DATE
TOL: X.
X.X
+/- 1
+/- 0.2
OFFSHORE KESUMA SO 140373
X.XX AS STATED H.VOGELS 2022-05-20 - TITLE: SCALE
32 West Thebarton Rd
GA RCI4100 NAUTILUS 340LA-130 N/A
DRAFTING STANDARD: AS1100
THEBARTON SN 010004C TW HAZ SHEET
DO NOT SCALE DRAWING SOUTH AUSTRALIA 5031 2 OF 3
ALL DIMENSIONS ARE IN MILLIMETERS web : www.robway.com
UNLESS OTHERWISE STATED PH: +61 8 8238 3500 DRAWING No: FILE No: REV
FX: +61 8 8352 1684 5990 5990-A.DWG A
1 2 3 4 1 2 3 4

5 6 7 8 5 6 7 8
1 2 3 4 5 6 7 8

SCL
SDA

SUPPLY -
n/c
n/c
n/c
n/c
n/c
n/c
n/c
SUPPLY +
n/c

n/c
D1063S D1063S 1-8 Safe Area

0D1

0D4
0D5
0D6
0D7
0D8
0D3
0D2
MAIN AUX 2

1
NO NO NO NO NO NO NO NO

9-16 Haz Area

SDA
SCL
n/c

n/c

n/c
n/c
n/c
n/c
n/c
n/c
n/c
0V
6V
P4 P18 P17 P16 9 10 11 12 13 14 15 16 C C C C C C C C
RS232 RELAY 3 RELAY 2 RELAY 1
9 10 11 12 9 10 11 12
CIRPCB4205 RevB

NC NC NC NC NC NC NC NC

NO
NC

NO
NC
NO
NC
COM

COM
COM
RX
0V
TX
13 14 15 16 13 14 15 16

3.15A
P15

6V
SDA
SCL
GND

GND
6V
SDA
SCL
V+
F3 V+
V-
NO
V-
24V

24V
GND

GND
GND
485+
485-

GND
485+
485-
P14 P19

RS485 RS485
COMMON
X250 GROUND
X1
X2
5VEX
C
24VEX
P2
24V
24V
OD2

24V
24V
OD1

OD4
OD3

F5 F2
P10 F4 F1
EX1

EX2

EX3

EX4
G

G
A1+
A1-

A2+
A2-

A3+
A3-

A4+
A4-

DI1-
DI1+
DI2-
DI2+
DI3-
DI3+
DI4-
DI4+
24V-

24V

24V

24V

P5
500mA
500mA

NC
500mA

500mA

X250 DIGITAL INPUTS 1


X1 P3
X2
24V
24V
OD6

24V
24V
OD5

OD8
OD7

5VEX
24VEX

+ - + -
+
GND
DI7-
DI5-
DI5+
DI6-
DI6+

DI7+

DI8+
24V-

24V

DI8-
24V

24V

P11 P13
DAC0
DAC1
0V
0V

P1 P7
EX5

EX6

EX7

EX8
G

G
A5+
A5-

A6+
A6-

A7+
A7-

A8+
A8-

ATB1 ATB2
IO4
IO5
IO1
IO2
IO3

IO7
IO6

5V
IO8
GND

24V P6 P9
DIGITAL INPUTS 2 EV EV EV 1- 1+ 4- 4+ 7- 7+ T- T+ NONONO
P20
A3 A7 A8 2- 2+ 5- 5+ 8- 8+ R- R+ 1C 2C 3C

G G G 3- 3+ 6- 6+ G 24V NC NCNC

SET JUMPERS AS SHOWN

PART OF ASSY CUSTOMER: PROJECT:


REV DATE DESCRIPTION OF CHANGE APPR'D DRAWN DATE
TOL: X.
X.X
+/- 1
+/- 0.2
OFFSHORE KESUMA SO 140373
X.XX AS STATED H.VOGELS 2022-05-20 - TITLE: SCALE
32 West Thebarton Rd
GA RCI4100 NAUTILUS 340LA-130 N/A
DRAFTING STANDARD: AS1100
THEBARTON SN 010004C TW HAZ SHEET
DO NOT SCALE DRAWING SOUTH AUSTRALIA 5031 3 OF 3
ALL DIMENSIONS ARE IN MILLIMETERS web : www.robway.com
UNLESS OTHERWISE STATED PH: +61 8 8238 3500 DRAWING No: FILE No: REV
FX: +61 8 8352 1684 5990 5990-A.DWG A