This document from the Civil Defence Department of Qatar outlines fire safety standards for low-rise residential apartments and penthouses. It provides minimum requirements including the provision of fire extinguishers and a dry rising main, a minimum of two exits complying with NFPA 101, permanently fixed staircase ventilation openings covering 20% of the area at each floor, a fire alarm system per QCDD requirements, and smoke vents for any basement parking covering at least 2.5% of the floor area and within 12 meters of all points.
This document from the Civil Defence Department of Qatar outlines fire safety standards for low-rise residential apartments and penthouses. It provides minimum requirements including the provision of fire extinguishers and a dry rising main, a minimum of two exits complying with NFPA 101, permanently fixed staircase ventilation openings covering 20% of the area at each floor, a fire alarm system per QCDD requirements, and smoke vents for any basement parking covering at least 2.5% of the floor area and within 12 meters of all points.
This document from the Civil Defence Department of Qatar outlines fire safety standards for low-rise residential apartments and penthouses. It provides minimum requirements including the provision of fire extinguishers and a dry rising main, a minimum of two exits complying with NFPA 101, permanently fixed staircase ventilation openings covering 20% of the area at each floor, a fire alarm system per QCDD requirements, and smoke vents for any basement parking covering at least 2.5% of the floor area and within 12 meters of all points.
MINIMUM REQUIREMENTS Subject: FIRE SAFETY PROVISIONS FOR LOW RISE FSS No: 1.4 RESIDENTIAL APARTMENT OR PENTHOUSE Low rise residential apartment or penthouse development is allowed to be exempted from approved automatic sprinkler system provided the following conditions are met: 1.0 Fire Suppression System • Provision of fire extinguisher in accordance with NFPA 10 throughout the building inclusive of dwelling unit; • 100mm diameter dry rising main with breeching inlet located not more than 18M from fire engine hardstanding/fire engine access road 2.0 Exit • Minimum two numbers • Comply with NFPA 101 Life Safety Code 3.0 Staircase • Permanently fixed ventilation openings of area not less than 20% of the staircase floor area at each floor; • Ventilation opening shall open to external or air-well having horizontal plan area of not less than 10m2. The minimum with of such air-well shall not be less than 3000mm. • Ventilation opening shall not be less than 3000mm from any opening. 4.0 Fire Detection System • Fire alarm system shall be provided throughout the building as required by QCDD Fire Alarm System Requirements 6.1; • Manual call point shall be provided not more than 1.5M away from any entry to the exit. 5.0 Car Park • At grade or above grade car park shall comply with NFPA 5000 Section 30.8.1.3 on open parking structure. • Only one basement car park is allowed and no other type of occupancy is allowed in the basement; • Basement car park shall have adequately distributed smoke vents. The number and their sizes shall be such that the aggregate effective vent openings shall not be less than 2.5% of the basement floor area served. No part of the basement shall be more than 12M form the smoke vents
Prepared by Yeo Swee Khiank Date: 23rd July, 2007
QCDFSS-1.4_Low Rise Residential Apartments Page 1 of 1