PVVPH1739aprv

Preview

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
Exceeding boundaries
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
with innovative energy savings
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

VRV is a trade mark of Daikin Industries, Ltd.


VRV Air Conditioning System is the world's first individual air conditioning system with variable refrigerant flow control and was commercialised by Daikin in 1982.
VRV is the trade mark of Daikin Industries, Ltd., which is derived from the technology we call "variable refrigerant volume."

•Specifications, designs and other content appearing in this brochure are current as of August 2017 but subject to change without notice.
c All rights reserved
AD. Cooling Only 60 Hz
New heights in energy efficiency
during actual operation
Hardware
New Scroll Compressor* technology
The key to innovative energy •Correlation between the load factor for the rated capacity and operation time
(in office buildings in Singapore)
savings is to increase efficiency *According to a survey by Daikin (based on Air Conditioning Network Service System data)
Refrigerant leakage is minimised during low-load operation.
Operation loss due to refrigerant leakage is reduced by the proprietary
during low-load operation.
back pressure control mechanism to ensure stable low-load operation.

Using data gathered from actual operation, Load factor of 50% or less Back pressure control mechanism
Daikin discovered that air conditioning accounts for 80% of
Conventional mechanism New intermediate pressure mechanism
annual operation period. New

Operation period
systems operate at a load factor of 50% or
The movable scroll is pressed by The force pressing the movable scroll
less for 80% of their annual operation the pressure difference between
high and low pressures.
is optimised according to operating
period. conditions. The behavior of the
The force pressing the movable
This inspired us to develop new scroll decreases during low-load movable scroll has been stabilised to
technologies to enhance energy efficiency operation, resulting in
compression leakage from
increase efficiency during low-load
during low loads. movable parts. operation.
Utilising these technologies, Daikin’s new •Compressor efficiency*
VRV X and A series raise the standard for Intermediate pressure
New compressor
adjustment port
energy efficiency. Conventional compressor

Compressor efficiency
0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% The intermediate pressure
(back pressure) optimises
the force pressing the
Load factor for the rated capacity movable scroll depending
on the operating condition.

Energy saving The force pressing the


movable scroll decreases
during low-load operation.
The intermediate pressure
keeps pressing the movable
scroll during
The back pressure control mechanism
increases the efficiency during
low-load operation.
low-load operation.
Uniting advanced software and hardware technologies for greater Load factor

energy savings during actual operation. * The new mechanism is used in all models except for RXUQ8A, RXQ6, 8, 16, and 18A. *Graph shown above is for illustration purpose only.

Software
Variable Refrigerant Temperature Smart Control (Fully Automatic Energy-saving Refrigerant Control) technology
Optimally supply only for the needed capacity of indoor units Other technologies to increase efficiency
Daikin developed Variable Refrigerant Temperature smart control by combining air volume control (VAV: valuable air Optimal amount of refrigerant is Standby power consumption is reduced
volume) for indoor units with conventional Variable Refrigerant Temperature control, which optimises compressor charged automatically The advanced oil temperature control reduces standby
speed by calculating the required load for the entire system and optimal target refrigerant temperature based on data The automatic refrigerant charge function automatically power consumption by up to 82.7%* annually compared to
sent from each indoor unit. Coordination with the air volume control reduces compressor load and minimises determines the optimal amount of refrigerant to be charged. conventional models. Standby power needed for preheating
operation loss based on detailed control. Variable Refrigerant Temperature smart control ensures energy savings and This function prevents a capacity shortage or energy loss refrigerator oil, which consumed substantial standby power,
comfortable air conditioning to meet actual operating conditions. due to excessive or insufficient refrigerant. was reduced to save energy when the air conditioner is
•Overview of the control (system control flow) stopped.
Different automatic energy-saving refrigerant control applies depending on the indoor units connected. Two compressors provide optimum operation* * Operation calculation conditions: VRV A series 14 HP
Location: Singapore
The outdoor unit is equipped with two compressors. Operation time: 08:00–18:00 on weekdays
Target indoor units
1
Temperature The speed of each compressor is automatically controlled to
Subject to Variable Refrigerant Subject to Variable Refrigerant
data received constantly optimise the overall efficiency depending on the Effective use of heat exchange area*
from indoor units
Temperature smart control Temperature control load. The start-stop loss during low-load operation is also The heat exchanger area is larger than that of conventional
minimised to increase efficiency. systems in which one compressor is operated.
C oord i nated co ntrol *Only available for VRV X series. This helps improve the efficiency of heat exchange during
low-load operation.
*Only available for VRV X series.
The following items are
The Variable Refrigerant Temperature
forecast and calculated based smart control also controls the airflow
on the required capacity: rate of indoor units automatically*, to
•Indoor fan air volume attain detailed energy-saving control. When one New Even when one

2
Select the target
3
•Target value of refrigerant * Airflow rate should be set to “Auto”. Compressor High-COP type compressor stops,
compressor stops,
refrigerant the heat exchange
temperature speed control (12 HP) area decreases to half. the heat exchange
temperature area does not decrease.
(12 HP)

The smooth control •Changes in the air-conditioned room temperature during low-load operation*
(which keeps the compressor Conventional air-conditioning method Fully automatic energy-saving Higher efficiency is provided during rated operation.
refrigerant control
running) saves energy and Changes in the room temperature: Large COP at 100% operation load
The power consumption attributed to the Changes in the room temperature: Small
ensures comfort during low-load star t-stop loss also increases the load. Wasted power consumption is also 5 4.82 4.75 4.71
Start minimised. 4.40 4.33
Cooling operation COP

operation. 4.32 4.13


4.07
Temperature 4 3.80 3.74 3.78 New
Room temperature setting 3.46
Turned off by Turned off by Turned off by 3.25
3.11
the thermostat the thermostat the thermostat 3
*Graph shown above is for illustration purpose only.

Note: VRV IV VRV


•For the classification of indoor units (Variable Refrigerant Temperature smart control and Variable Refrigerant Temperature control), refer to pages 5–6. X SERIES
•If a system has indoor units subject to both Variable Refrigerant Temperature smart and Variable Refrigerant Temperature control, the system is operated under 0
Variable Refrigerant Temperature control. 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP
•If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, Variable Refrigerant Temperature smart control and
Variable Refrigerant Temperature control are disabled. Cooling operation conditions : Indoor temp, of 27°CDB, 19°CWB, and outdoor temp, of 35°CDB.
1 2
New heights in energy efficiency
during actual operation
Hardware
New Scroll Compressor* technology
The key to innovative energy •Correlation between the load factor for the rated capacity and operation time
(in office buildings in Singapore)
savings is to increase efficiency *According to a survey by Daikin (based on Air Conditioning Network Service System data)
Refrigerant leakage is minimised during low-load operation.
Operation loss due to refrigerant leakage is reduced by the proprietary
during low-load operation.
back pressure control mechanism to ensure stable low-load operation.

Using data gathered from actual operation, Load factor of 50% or less Back pressure control mechanism
Daikin discovered that air conditioning accounts for 80% of
Conventional mechanism New intermediate pressure mechanism
annual operation period. New

Operation period
systems operate at a load factor of 50% or
The movable scroll is pressed by The force pressing the movable scroll
less for 80% of their annual operation the pressure difference between
high and low pressures.
is optimised according to operating
period. conditions. The behavior of the
The force pressing the movable
This inspired us to develop new scroll decreases during low-load movable scroll has been stabilised to
technologies to enhance energy efficiency operation, resulting in
compression leakage from
increase efficiency during low-load
during low loads. movable parts. operation.
Utilising these technologies, Daikin’s new •Compressor efficiency*
VRV X and A series raise the standard for Intermediate pressure
New compressor
adjustment port
energy efficiency. Conventional compressor

Compressor efficiency
0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% The intermediate pressure
(back pressure) optimises
the force pressing the
Load factor for the rated capacity movable scroll depending
on the operating condition.

Energy saving The force pressing the


movable scroll decreases
during low-load operation.
The intermediate pressure
keeps pressing the movable
scroll during
The back pressure control mechanism
increases the efficiency during
low-load operation.
low-load operation.
Uniting advanced software and hardware technologies for greater Load factor

energy savings during actual operation. * The new mechanism is used in all models except for RXUQ8A, RXQ6, 8, 16, and 18A. *Graph shown above is for illustration purpose only.

Software
Variable Refrigerant Temperature Smart Control (Fully Automatic Energy-saving Refrigerant Control) technology
Optimally supply only for the needed capacity of indoor units Other technologies to increase efficiency
Daikin developed Variable Refrigerant Temperature smart control by combining air volume control (VAV: valuable air Optimal amount of refrigerant is Standby power consumption is reduced
volume) for indoor units with conventional Variable Refrigerant Temperature control, which optimises compressor charged automatically The advanced oil temperature control reduces standby
speed by calculating the required load for the entire system and optimal target refrigerant temperature based on data The automatic refrigerant charge function automatically power consumption by up to 82.7%* annually compared to
sent from each indoor unit. Coordination with the air volume control reduces compressor load and minimises determines the optimal amount of refrigerant to be charged. conventional models. Standby power needed for preheating
operation loss based on detailed control. Variable Refrigerant Temperature smart control ensures energy savings and This function prevents a capacity shortage or energy loss refrigerator oil, which consumed substantial standby power,
comfortable air conditioning to meet actual operating conditions. due to excessive or insufficient refrigerant. was reduced to save energy when the air conditioner is
•Overview of the control (system control flow) stopped.
Different automatic energy-saving refrigerant control applies depending on the indoor units connected. Two compressors provide optimum operation* * Operation calculation conditions: VRV A series 14 HP
Location: Singapore
The outdoor unit is equipped with two compressors. Operation time: 08:00–18:00 on weekdays
Target indoor units
1
Temperature The speed of each compressor is automatically controlled to
Subject to Variable Refrigerant Subject to Variable Refrigerant
data received constantly optimise the overall efficiency depending on the Effective use of heat exchange area*
from indoor units
Temperature smart control Temperature control load. The start-stop loss during low-load operation is also The heat exchanger area is larger than that of conventional
minimised to increase efficiency. systems in which one compressor is operated.
C oord i nated co ntrol *Only available for VRV X series. This helps improve the efficiency of heat exchange during
low-load operation.
*Only available for VRV X series.
The following items are
The Variable Refrigerant Temperature
forecast and calculated based smart control also controls the airflow
on the required capacity: rate of indoor units automatically*, to
•Indoor fan air volume attain detailed energy-saving control. When one New Even when one

2
Select the target
3
•Target value of refrigerant * Airflow rate should be set to “Auto”. Compressor High-COP type compressor stops,
compressor stops,
refrigerant the heat exchange
temperature speed control (12 HP) area decreases to half. the heat exchange
temperature area does not decrease.
(12 HP)

The smooth control •Changes in the air-conditioned room temperature during low-load operation*
(which keeps the compressor Conventional air-conditioning method Fully automatic energy-saving Higher efficiency is provided during rated operation.
refrigerant control
running) saves energy and Changes in the room temperature: Large COP at 100% operation load
The power consumption attributed to the Changes in the room temperature: Small
ensures comfort during low-load star t-stop loss also increases the load. Wasted power consumption is also 5 4.82 4.75 4.71
Start minimised. 4.40 4.33
Cooling operation COP

operation. 4.32 4.13


4.07
Temperature 4 3.80 3.74 3.78 New
Room temperature setting 3.46
Turned off by Turned off by Turned off by 3.25
3.11
the thermostat the thermostat the thermostat 3
*Graph shown above is for illustration purpose only.

Note: VRV IV VRV


•For the classification of indoor units (Variable Refrigerant Temperature smart control and Variable Refrigerant Temperature control), refer to pages 5–6. X SERIES
•If a system has indoor units subject to both Variable Refrigerant Temperature smart and Variable Refrigerant Temperature control, the system is operated under 0
Variable Refrigerant Temperature control. 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP
•If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, Variable Refrigerant Temperature smart control and
Variable Refrigerant Temperature control are disabled. Cooling operation conditions : Indoor temp, of 27°CDB, 19°CWB, and outdoor temp, of 35°CDB.
1 2
Easy installation New indoor units are designed with Variable Refrigerant Temperature
Contribute to simple on-site installation and higher quality smart control to be more energy efficient and comfortable.
Automatic Refrigerant Charge Function
The automatic refrigerant charge function automates the charging of the proper refrigerant amount
Ceiling Mounted Cassette Type
and the closing of shut-off valves with just one press of the switch after pre-charging. Ceiling Mounted Cassette Ceiling Mounted Cassette
Simplified installation eliminates excessive and insufficient refrigerant charge amounts due to ( Round Flow with Sensing ) Type ( Round Flow ) Type
calculation mistakes, and this has led to higher installation quality.

VRV IV New FXFSQ-AVM New FXFQ-AVM


1 2 3 4 5
Calculate necessary Recalculate refrigerant Charge refrigerant Regularly check refrigerant Complete by manually
refrigerant amount from amount from final weight on weighing scale closing valves when proper
design drawing installation drawing weight is reached

Circulation Airflow Configurations of Circulation Airflow


1 2 3 Automatic completion by proper Operation Performs repeatedly
Calculation of necessary Pre-charge of refrigerant* Start of automatic refrigerant amount (at start) Airflow
direction
refrigerant amount from refrigerant charge operation 1. Blows horizontally changes
design drawing Monitoring refrigerant charging is
unnecessary 2. Strikes the wall

No recalculation of charge amounts due Cools areas around Cools entire room Cools areas around Cools entire room
walls using using 4-way walls using using 4-way swing flow
to minor design changes locally 2-way horizontal flow swing flow 2-way horizontal flow

*Pre-charge amount changes according to conditions, 3. Reaches every When the target temperature is reached,
and there are cases when pre-charging is unnecessary. corner of the room normal operation (all-round flow) begins.

High reliability
Note: Results may vary depending on equipment conditions, room size,
and distance from indoor unit to walls.

Long-lasting, reliable operation Individual Airflow Direction Control Dual Sensors*


Daikin Advanced Sensing Technology
Backup Operation to Avoid Shutdown due to Failure* Airflow direction can be
individually adjusted for
The outdoor unit is equipped with two compressors. Even if one compressor each air discharge outlet to
malfunctions, the other compressor provides emergency operation, reducing Emergency deliver optimal air Infrared presence sensor
the risk of air conditioning shutdown due to compressor failure. operation Malfunction distribution.
(The capacity is saved during backup operation.) The 4 sensors detect
Position 0
human presence.
* This feature is available in all models of the VRV X series and models with the capacity of 16 HP or higher
of the VRV A series. On-site settings are required using the printed circuit board of the outdoor unit. (Fixed airflow to
highest position) Detecting the Infrared floor sensor
The illustration shows typical airflow. presence of people
Improved Anti-corrosion Specifications in 4 areas The sensor detects the
floor temperature and
Daikin has developed proprietary models to meet the operating conditions New Heavy anti-corrosion model C
automatically adjusts
found in ASEAN countries (installation in humid/coastal areas, operation Casing colour : Metallic brown B D
operation of the indoor unit
A
throughout the year). Resistance to salt damage is four times greater for No individual
to reduce the temperature
anti-corrosion than in conventional models. setting
(Auto airflow) difference between the
* This model is a made-to-order product. Because more days are required before factory shipment, please confirm the delivery day when ordering. Detecting the
average temperature
ceiling and the floor.
Swing Position 4 of indoor floor

Extensive product lineup


(Up/down) (Fixed airflow to the
New lowest position)
*Applicable when sensing panel is installed.
•The lineup consists of 2 series with the VRV X series featuring new models specially developed for high efficiency.
•The VRV X series achieves higher efficiency in a design that is more compact and lightweight than the VRV IV High-COP type,
and the capacity of the lineup has been further expanded. (12 HP– 50 HP 8 HP–60 HP)
Direct Air* When human
presence detected.
With Auto airflow direction mode, when
VRV human is detected, air direction is set to
New
High-COP type (12 HP) (12 HP) “Swing(narrow)” to deliver cool air to users.

COP 4.41 4.71 7% Increase *Applicable when sensing panel is installed.


Optimal air direction Swing (narrow)
Installation space 0.95 m 2 37% Decrease by “Auto”
1.42 m 2

1,860 mm 765 mm Product weight 370 kg 312 kg 16% Decrease 1,240 mm


765 mm
Ceiling Mounted Duct Type
Lineup Mo/C New lineup
Slim Ceiling Mounted Duct Type (Standard Series) Middle Static Pressure Ceiling Mounted
HP 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Ceiling Mounted Duct Type Duct Type
— — — — — — — — — — — — — — — — — — — — —
New FXDQ-PDVE New FXDQ-NDVE
Single module (with drain pump) (with drain pump)
VRV X SERIES — — — — — —
Multi type
New FXDQ-PDVET New FXDQ-NDVET
Single module — — — — — — — — — — — — — — — — — — — — (without drain pump) (without drain pump) (900 / 1,100mm width type)
(700mm width type) New
FXSQ-PAVE New
FXMQ-PAVE
VRV A SERIES
Multi type — — — — — —

3 4
Easy installation New indoor units are designed with Variable Refrigerant Temperature
Contribute to simple on-site installation and higher quality smart control to be more energy efficient and comfortable.
Automatic Refrigerant Charge Function
The automatic refrigerant charge function automates the charging of the proper refrigerant amount
Ceiling Mounted Cassette Type
and the closing of shut-off valves with just one press of the switch after pre-charging. Ceiling Mounted Cassette Ceiling Mounted Cassette
Simplified installation eliminates excessive and insufficient refrigerant charge amounts due to ( Round Flow with Sensing ) Type ( Round Flow ) Type
calculation mistakes, and this has led to higher installation quality.

VRV IV New FXFSQ-AVM New FXFQ-AVM


1 2 3 4 5
Calculate necessary Recalculate refrigerant Charge refrigerant Regularly check refrigerant Complete by manually
refrigerant amount from amount from final weight on weighing scale closing valves when proper
design drawing installation drawing weight is reached

Circulation Airflow Configurations of Circulation Airflow


1 2 3 Automatic completion by proper Operation Performs repeatedly
Calculation of necessary Pre-charge of refrigerant* Start of automatic refrigerant amount (at start) Airflow
direction
refrigerant amount from refrigerant charge operation 1. Blows horizontally changes
design drawing Monitoring refrigerant charging is
unnecessary 2. Strikes the wall

No recalculation of charge amounts due Cools areas around Cools entire room Cools areas around Cools entire room
walls using using 4-way walls using using 4-way swing flow
to minor design changes locally 2-way horizontal flow swing flow 2-way horizontal flow

*Pre-charge amount changes according to conditions, 3. Reaches every When the target temperature is reached,
and there are cases when pre-charging is unnecessary. corner of the room normal operation (all-round flow) begins.

High reliability
Note: Results may vary depending on equipment conditions, room size,
and distance from indoor unit to walls.

Long-lasting, reliable operation Individual Airflow Direction Control Dual Sensors*


Daikin Advanced Sensing Technology
Backup Operation to Avoid Shutdown due to Failure* Airflow direction can be
individually adjusted for
The outdoor unit is equipped with two compressors. Even if one compressor each air discharge outlet to
malfunctions, the other compressor provides emergency operation, reducing Emergency deliver optimal air Infrared presence sensor
the risk of air conditioning shutdown due to compressor failure. operation Malfunction distribution.
(The capacity is saved during backup operation.) The 4 sensors detect
Position 0
human presence.
* This feature is available in all models of the VRV X series and models with the capacity of 16 HP or higher
of the VRV A series. On-site settings are required using the printed circuit board of the outdoor unit. (Fixed airflow to
highest position) Detecting the Infrared floor sensor
The illustration shows typical airflow. presence of people
Improved Anti-corrosion Specifications in 4 areas The sensor detects the
floor temperature and
Daikin has developed proprietary models to meet the operating conditions New Heavy anti-corrosion model C
automatically adjusts
found in ASEAN countries (installation in humid/coastal areas, operation Casing colour : Metallic brown B D
operation of the indoor unit
A
throughout the year). Resistance to salt damage is four times greater for No individual
to reduce the temperature
anti-corrosion than in conventional models. setting
(Auto airflow) difference between the
* This model is a made-to-order product. Because more days are required before factory shipment, please confirm the delivery day when ordering. Detecting the
average temperature
ceiling and the floor.
Swing Position 4 of indoor floor

Extensive product lineup


(Up/down) (Fixed airflow to the
New lowest position)
*Applicable when sensing panel is installed.
•The lineup consists of 2 series with the VRV X series featuring new models specially developed for high efficiency.
•The VRV X series achieves higher efficiency in a design that is more compact and lightweight than the VRV IV High-COP type,
and the capacity of the lineup has been further expanded. (12 HP– 50 HP 8 HP–60 HP)
Direct Air* When human
presence detected.
With Auto airflow direction mode, when
VRV human is detected, air direction is set to
New
High-COP type (12 HP) (12 HP) “Swing(narrow)” to deliver cool air to users.

COP 4.41 4.71 7% Increase *Applicable when sensing panel is installed.


Optimal air direction Swing (narrow)
Installation space 0.95 m 2 37% Decrease by “Auto”
1.42 m 2

1,860 mm 765 mm Product weight 370 kg 312 kg 16% Decrease 1,240 mm


765 mm
Ceiling Mounted Duct Type
Lineup Mo/C New lineup
Slim Ceiling Mounted Duct Type (Standard Series) Middle Static Pressure Ceiling Mounted
HP 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Ceiling Mounted Duct Type Duct Type
— — — — — — — — — — — — — — — — — — — — —
New FXDQ-PDVE New FXDQ-NDVE
Single module (with drain pump) (with drain pump)
VRV X SERIES — — — — — —
Multi type
New FXDQ-PDVET New FXDQ-NDVET
Single module — — — — — — — — — — — — — — — — — — — — (without drain pump) (without drain pump) (900 / 1,100mm width type)
(700mm width type) New
FXSQ-PAVE New
FXMQ-PAVE
VRV A SERIES
Multi type — — — — — —

3 4
Indoor unit lineup
Enhanced range of choices
A mixed combination of VRV indoor units and residential indoor units is enabled all in one system, opening the door to stylish and quiet indoor units.
New lineup smart Indoor units subject to Variable Refrigerant Temperature smart control

VRV indoor units basic Indoor units subject to Variable Refrigerant Temperature control
Residential indoor units with connection to BP units
25 35 50 60 71
Type Model Name Type Model Name Rated Capacity (kW) 2.5 3.5 5.0 6.0 7.1
Capacity Index 25 35 50 60 71
New
Ceiling Mounted Cassette New FXFSQ-AVM smart
capacity

(Round Flow with Sensing) Slim Ceiling (700 mm width type)


Mounted CDKS-KVM basic
New
Ceiling Mounted Cassette capacity Duct
New FXFQ-AVM smart
(Round Flow) (900/1,100 mm width type)

Ceiling Mounted Cassette FTKJ-NVMW basic


FXZQ-MVE basic
(Compact Multi Flow)
FTKJ-NVMS basic
Ceiling Mounted Cassette FXCQ-MVE basic
(Double Flow) Wall VRT
Mounted
Ceiling Mounted FTKS-KVM basic
FXKQ-MAVE basic
Cassette Corner

New FXDQ-PDVE smart


(with drain pump) Note: BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ8-20A and RXQ6-20A) can be connected.
New FXDQ-PDVET smart (700mm width type)
Slim Ceiling (without drain pump)
Mounted Duct
FXDQ-NDVE
(Standard Series) New
(with drain pump)
smart
VRV indoor units combine with indoor units, all in one system.
FXDQ-NDVET smart (900 / 1,100mm width type)
VRV indoor unit only system
New
(without drain pump)

Middle Static
Pressure Ceiling New FXSQ-PAVE smart
Mounted Duct
New FXMQ-PAVE smart
Ceiling Mounted
Duct
FXMQ-MAVE basic VRV indoor units only
Max. • If a system has indoor units subject to both Variable Refrigerant Temperature smart and Variable Refrigerant Temperature
Outdoor-Air FXMQ-MFVJU 64 indoor
units
control, the system is operated under Variable Refrigerant Temperature control.
• If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, Variable Refrigerant
Processing Unit Temperature smart control and Variable Refrigerant Temperature control are disabled.

4-Way Flow Ceiling FXUQ-AVEB basic


Suspended Residential indoor unit and VRV indoor unit mix system

Ceiling Suspended FXHQ-MAVE basic

Wall Mounted FXAQ-PVE basic BP unit

Floor Standing FXLQ-MAVE basic


Max.
Residential indoor units VRV indoor units
Concealed FXNQ-MAVE basic
32 indoor
units
Floor Standing • BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ8-20A and RXQ6-20A) can be connected.
• If a system has both residential indoor units and VRV indoor units, the system is operated under Variable Refrigerant
Temperature control.
Floor Standing FXVQ-NTL basic
Duct
Residential indoor unit only system
FXBQ-PVE basic
Clean Room
Air Conditioner
FXBPQ-PVE basic
BP unit BP unit
Heat Reclaim Ventilator VAM-GJVE Airflow rate 150-2000 m 3/h

* For connection of the air handling unit, please contact our sales office. Max. Residential indoor units only
32 indoor
units • BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ8-20A and RXQ6-20A) can be connected.
• If a system has only residential indoor units, the system is operated under Variable Refrigerant Temperature control.

5 6
Indoor unit lineup
Enhanced range of choices
A mixed combination of VRV indoor units and residential indoor units is enabled all in one system, opening the door to stylish and quiet indoor units.
New lineup smart Indoor units subject to Variable Refrigerant Temperature smart control

VRV indoor units basic Indoor units subject to Variable Refrigerant Temperature control
Residential indoor units with connection to BP units
25 35 50 60 71
Type Model Name Type Model Name Rated Capacity (kW) 2.5 3.5 5.0 6.0 7.1
Capacity Index 25 35 50 60 71
New
Ceiling Mounted Cassette New FXFSQ-AVM smart
capacity

(Round Flow with Sensing) Slim Ceiling (700 mm width type)


Mounted CDKS-KVM basic
New
Ceiling Mounted Cassette capacity Duct
New FXFQ-AVM smart
(Round Flow) (900/1,100 mm width type)

Ceiling Mounted Cassette FTKJ-NVMW basic


FXZQ-MVE basic
(Compact Multi Flow)
FTKJ-NVMS basic
Ceiling Mounted Cassette FXCQ-MVE basic
(Double Flow) Wall VRT
Mounted
Ceiling Mounted FTKS-KVM basic
FXKQ-MAVE basic
Cassette Corner

New FXDQ-PDVE smart


(with drain pump) Note: BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ8-20A and RXQ6-20A) can be connected.
New FXDQ-PDVET smart (700mm width type)
Slim Ceiling (without drain pump)
Mounted Duct
FXDQ-NDVE
(Standard Series) New
(with drain pump)
smart
VRV indoor units combine with indoor units, all in one system.
FXDQ-NDVET smart (900 / 1,100mm width type)
VRV indoor unit only system
New
(without drain pump)

Middle Static
Pressure Ceiling New FXSQ-PAVE smart
Mounted Duct
New FXMQ-PAVE smart
Ceiling Mounted
Duct
FXMQ-MAVE basic VRV indoor units only
Max. • If a system has indoor units subject to both Variable Refrigerant Temperature smart and Variable Refrigerant Temperature
Outdoor-Air FXMQ-MFVJU 64 indoor
units
control, the system is operated under Variable Refrigerant Temperature control.
• If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, Variable Refrigerant
Processing Unit Temperature smart control and Variable Refrigerant Temperature control are disabled.

4-Way Flow Ceiling FXUQ-AVEB basic


Suspended Residential indoor unit and VRV indoor unit mix system

Ceiling Suspended FXHQ-MAVE basic

Wall Mounted FXAQ-PVE basic BP unit

Floor Standing FXLQ-MAVE basic


Max.
Residential indoor units VRV indoor units
Concealed FXNQ-MAVE basic
32 indoor
units
Floor Standing • BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ8-20A and RXQ6-20A) can be connected.
• If a system has both residential indoor units and VRV indoor units, the system is operated under Variable Refrigerant
Temperature control.
Floor Standing FXVQ-NTL basic
Duct
Residential indoor unit only system
FXBQ-PVE basic
Clean Room
Air Conditioner
FXBPQ-PVE basic
BP unit BP unit
Heat Reclaim Ventilator VAM-GJVE Airflow rate 150-2000 m 3/h

* For connection of the air handling unit, please contact our sales office. Max. Residential indoor units only
32 indoor
units • BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ8-20A and RXQ6-20A) can be connected.
• If a system has only residential indoor units, the system is operated under Variable Refrigerant Temperature control.

5 6
Specifications
Outdoor Units

Model RXUQ8AYM(W) RXUQ10AYM(W) RXUQ12AYM(W) RXUQ14AYM(W) RXUQ16AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AMYM(W) RXUQ20AMYM(W) RXUQ22AMYM(W) RXUQ24AMYM(W) RXUQ26AMYM(W) RXUQ28AMYM(W) RXUQ30AMYM(W) RXUQ32AMYM(W) RXUQ34AMYM(W)
― ― ― ― ― ― ― RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ12AYM(W) RXUQ12AYM(W) RXUQ16AYM(W)
Combination units
― ― ― ― ― ― ― RXUQ10AYM(W) RXUQ12AYM(W) RXUQ14AYM(W) RXUQ16AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AYM(W)
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
kcal/h 19,300 24,100 28,800 34,400 38,700 43,000 48,200 43,300 48,100 53,700 58,000 62,300 67,400 71,800 77,000 81,700
Cooling capacity Btu/h 76,400 95,500 114,000 136,000 154,000 171,000 191,000 172,000 191,000 213,000 230,000 247,000 268,000 285,000 305,000 324,000
kW 22.4 28.0 33.5 40.0 45.0 50.0 56.0 50.4 55.9 62.4 67.4 72.4 78.4 83.5 89.5 95.0
Power consumption kW 4.65 5.89 7.11 9.09 10.4 12.1 14.8 10.5 11.8 13.7 15.1 16.8 19.5 19.2 21.9 22.5
Casing colour Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown
Airflow rate m3/min 163 192 213 218 268 163+192 163+213 163+218 163+268 213+268 218+268
Dimensions (H×W×D) mm 1,657×1,240×765 (1,657×1,240×765)+(1,657×1,240×765)
Machine weight kg 273 312 318 273+312 273+318 312+318 318+318
Sound level dB(A) 55 57 60 61 65 59 61 62 65 66
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 8.1 11.3 11.4 11.5 11.7 8.1+11.3 8.1+11.4 8.1+11.5 8.1+11.7 11.4+11.7 11.7+11.7
Piping Liquid mm φ9.5 (Brazing) φ12.7 (Brazing) φ15.9 (Brazing) φ15.9 (Brazing) φ19.1 (Brazing)
connections Gas mm φ19.1 (Brazing) φ22.2 (Brazing) φ28.6 (Brazing) φ28.6 (Brazing) φ34.9 (Brazing)

Model RXUQ36AMYM(W) RXUQ38AMYM(W) RXUQ40AMYM(W) RXUQ42AMYM(W) RXUQ44AMYM(W) RXUQ46AMYM(W) RXUQ48AMYM(W) RXUQ50AMYM(W) RXUQ52AMYM(W) RXUQ54AMYM(W) RXUQ56AMYM(W) RXUQ58AMYM(W) RXUQ60AMYM(W)
RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ12AYM(W) RXUQ12AYM(W) RXUQ18AYM(W) RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W)
Combination units RXUQ18AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ16AYM(W) RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ20AYM(W)
― ― ― RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W)
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
kcal/h 86,000 91,200 96,300 101,000 105,000 110,000 115,000 120,000 126,000 129,000 134,000 139,000 144,000
Cooling capacity Btu/h 341,000 362,000 382,000 399,000 416,000 437,000 457,000 478,000 498,000 512,000 532,000 553,000 573,000
kW 100 106 112 117 122 128 134 140 146 150 156 162 168
Power consumption kW 24.2 26.9 29.6 27.2 28.9 31.6 34.3 34.0 36.7 36.3 39.0 41.7 44.4
Casing colour Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown
Airflow rate m3/min 268+268 163+218+268 163+268+268 213+268+268 268+268+268
Dimensions (H×W×D) mm (1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)
Machine weight kg 318+318 273+318+318 312+318+318 318+318+318
Sound level dB(A) 68 67 68 69 70
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 11.7+11.7 8.1+11.7+11.7 11.4+11.7+11.7 11.7+11.7+11.7
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ41.3 (Brazing) φ41.3 (Brazing)
Note: 1. Models with (W) are the outdoor units with heavy anti-corrosion specifications. Please refer to Engineering Data Book for details.
2. Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27℃DB, 19℃WB, Outdoor temp.: 35℃DB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

7 8
Specifications
Outdoor Units

Model RXUQ8AYM(W) RXUQ10AYM(W) RXUQ12AYM(W) RXUQ14AYM(W) RXUQ16AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AMYM(W) RXUQ20AMYM(W) RXUQ22AMYM(W) RXUQ24AMYM(W) RXUQ26AMYM(W) RXUQ28AMYM(W) RXUQ30AMYM(W) RXUQ32AMYM(W) RXUQ34AMYM(W)
― ― ― ― ― ― ― RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ12AYM(W) RXUQ12AYM(W) RXUQ16AYM(W)
Combination units
― ― ― ― ― ― ― RXUQ10AYM(W) RXUQ12AYM(W) RXUQ14AYM(W) RXUQ16AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AYM(W)
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
kcal/h 19,300 24,100 28,800 34,400 38,700 43,000 48,200 43,300 48,100 53,700 58,000 62,300 67,400 71,800 77,000 81,700
Cooling capacity Btu/h 76,400 95,500 114,000 136,000 154,000 171,000 191,000 172,000 191,000 213,000 230,000 247,000 268,000 285,000 305,000 324,000
kW 22.4 28.0 33.5 40.0 45.0 50.0 56.0 50.4 55.9 62.4 67.4 72.4 78.4 83.5 89.5 95.0
Power consumption kW 4.65 5.89 7.11 9.09 10.4 12.1 14.8 10.5 11.8 13.7 15.1 16.8 19.5 19.2 21.9 22.5
Casing colour Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown
Airflow rate m3/min 163 192 213 218 268 163+192 163+213 163+218 163+268 213+268 218+268
Dimensions (H×W×D) mm 1,657×1,240×765 (1,657×1,240×765)+(1,657×1,240×765)
Machine weight kg 273 312 318 273+312 273+318 312+318 318+318
Sound level dB(A) 55 57 60 61 65 59 61 62 65 66
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 8.1 11.3 11.4 11.5 11.7 8.1+11.3 8.1+11.4 8.1+11.5 8.1+11.7 11.4+11.7 11.7+11.7
Piping Liquid mm φ9.5 (Brazing) φ12.7 (Brazing) φ15.9 (Brazing) φ15.9 (Brazing) φ19.1 (Brazing)
connections Gas mm φ19.1 (Brazing) φ22.2 (Brazing) φ28.6 (Brazing) φ28.6 (Brazing) φ34.9 (Brazing)

Model RXUQ36AMYM(W) RXUQ38AMYM(W) RXUQ40AMYM(W) RXUQ42AMYM(W) RXUQ44AMYM(W) RXUQ46AMYM(W) RXUQ48AMYM(W) RXUQ50AMYM(W) RXUQ52AMYM(W) RXUQ54AMYM(W) RXUQ56AMYM(W) RXUQ58AMYM(W) RXUQ60AMYM(W)
RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ8AYM(W) RXUQ12AYM(W) RXUQ12AYM(W) RXUQ18AYM(W) RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W)
Combination units RXUQ18AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ16AYM(W) RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ20AYM(W)
― ― ― RXUQ18AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W)
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
kcal/h 86,000 91,200 96,300 101,000 105,000 110,000 115,000 120,000 126,000 129,000 134,000 139,000 144,000
Cooling capacity Btu/h 341,000 362,000 382,000 399,000 416,000 437,000 457,000 478,000 498,000 512,000 532,000 553,000 573,000
kW 100 106 112 117 122 128 134 140 146 150 156 162 168
Power consumption kW 24.2 26.9 29.6 27.2 28.9 31.6 34.3 34.0 36.7 36.3 39.0 41.7 44.4
Casing colour Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown
Airflow rate m3/min 268+268 163+218+268 163+268+268 213+268+268 268+268+268
Dimensions (H×W×D) mm (1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)
Machine weight kg 318+318 273+318+318 312+318+318 318+318+318
Sound level dB(A) 68 67 68 69 70
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 11.7+11.7 8.1+11.7+11.7 11.4+11.7+11.7 11.7+11.7+11.7
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ41.3 (Brazing) φ41.3 (Brazing)
Note: 1. Models with (W) are the outdoor units with heavy anti-corrosion specifications. Please refer to Engineering Data Book for details.
2. Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27℃DB, 19℃WB, Outdoor temp.: 35℃DB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

7 8
Specifications
Outdoor Units

Model RXQ6AYM(W) RXQ8AYM(W) RXQ10AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ18AMYM(W) RXQ20AMYM(W) RXQ22AMYM(W) RXQ24AMYM(W) RXQ26AMYM(W) RXQ28AMYM(W) RXQ30AMYM(W)
― ― ― ― ― ― ― ― RXQ8AYM(W) RXQ8AYM(W) RXQ10AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ12AYM(W)
Combination units
― ― ― ― ― ― ― ― RXQ10AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W)
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
kcal/h 13,800 19,300 24,100 28,800 34,400 38,700 43,000 48,200 43,300 48,100 52,900 57,600 63,200 67,500 71,800
Cooling capacity Btu/h 54,600 76,400 95,500 114,000 136,000 154,000 171,000 191,000 172,000 191,000 210,000 229,000 251,000 268,000 285,000
kW 16.0 22.4 28.0 33.5 40.0 45.0 50.0 56.0 50.4 55.9 61.5 67.0 73.5 78.5 83.5
Power consumption kW 3.38 5.17 6.84 8.70 10.7 12.9 15.3 17.7 12.0 13.9 15.5 17.4 19.4 21.6 24.0
Casing colour Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown
Airflow rate m3/min 119 178 191 257 297 178+178 178+191 191+191 191+257
Dimensions (H×W×D ) mm 1,657×930×765 1,657×1,240×765 1,657×1,240×765 (1,657×930×765)+(1,657×930×765) (1,657×930×765)+(1,657×1,240×765)
Machine weight kg 175 185 233 276 312 175+185 185+185 185+233 185+276
Sound level dB(A) 56 57 59 60 61 65 60 61 62 63
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 5.9 6.7 6.8 7.4 8.2 8.4 11.8 5.9+6.7 5.9+6.8 6.7+6.8 6.8+6.8 6.8+7.4 6.8+8.2 6.8+8.4
Piping Liquid mm φ9.5 (Brazing) φ12.7 (Brazing) φ15.9 (Brazing) φ15.9 (Brazing) φ19.1 (Brazing)
connections Gas mm φ19.1 (Brazing) φ22.2 (Brazing) φ28.6 (Brazing) φ28.6 (Brazing) φ34.9 (Brazing)

Model RXQ32AMYM(W) RXQ34AMYM(W) RXQ36AMYM(W) RXQ38AMYM(W) RXQ40AMYM(W) RXQ42AMYM(W) RXQ44AMYM(W) RXQ46AMYM(W) RXQ48AMYM(W) RXQ50AMYM(W) RXQ52AMYM(W) RXQ54AMYM(W) RXQ56AMYM(W) RXQ58AMYM(W) RXQ60AMYM(W)
RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ14AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W)
Combination units RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ20AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ20AYM(W)
― ― ― ― ― RXQ18AYM(W) RXQ20AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ20AYM(W) RXQ20AYM(W)
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
kcal/h 77,400 81,700 86,000 91,200 96,300 101,000 106,000 112,000 116,000 120,000 125,000 129,000 134,000 139,000 144,000
Cooling capacity Btu/h 307,000 324,000 341,000 362,000 382,000 399,000 420,000 444,000 461,000 478,000 495,000 512,000 532,000 553,000 573,000
kW 90.0 95.0 100 106 112 117 123 130 135 140 145 150 156 162 168
Power consumption kW 26.0 28.2 30.6 33.0 35.4 32.7 35.1 36.7 38.9 41.3 43.5 45.9 48.3 50.7 53.1
Casing colour Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown
Airflow rate m3/min 257+257 257+297 297+297 191+191+257 191+191+297 257+257+257 257+257+297 257+297+297 297+297+297
(1,657×930×765)+(1,657×930×765)+
Dimensions (H×W×D) mm (1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)
(1,657×1,240×765)
Machine weight kg 233+276 276+276 276+312 312+312 185+185+276 185+185+312 233+233+276 233+276+276 276+276+276 276+276+312 276+312+312 312+312+312
Sound level dB(A) 64 66 68 65 67 65 66 68 69 70
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 7.4+8.4 8.2+8.4 8.4+8.4 8.4+11.8 11.8+11.8 6.8+6.8+8.4 6.8+6.8+11.8 7.4+7.4+8.4 7.4+8.2+8.4 7.4+8.4+8.4 8.2+8.4+8.4 8.4+8.4+8.4 8.4+8.4+11.8 8.4+11.8+11.8 11.8+11.8+11.8
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ34.9 (Brazing) φ41.3 (Brazing) φ41.3 (Brazing)

Note: 1. Models with (W) are the outdoor units with heavy anti-corrosion specifications. Please refer to Engineering Data Book for details.
2. Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27℃DB, 19℃WB, Outdoor temp.: 35℃DB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

9 10
Specifications
Outdoor Units

Model RXQ6AYM(W) RXQ8AYM(W) RXQ10AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ18AMYM(W) RXQ20AMYM(W) RXQ22AMYM(W) RXQ24AMYM(W) RXQ26AMYM(W) RXQ28AMYM(W) RXQ30AMYM(W)
― ― ― ― ― ― ― ― RXQ8AYM(W) RXQ8AYM(W) RXQ10AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ12AYM(W)
Combination units
― ― ― ― ― ― ― ― RXQ10AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W)
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
kcal/h 13,800 19,300 24,100 28,800 34,400 38,700 43,000 48,200 43,300 48,100 52,900 57,600 63,200 67,500 71,800
Cooling capacity Btu/h 54,600 76,400 95,500 114,000 136,000 154,000 171,000 191,000 172,000 191,000 210,000 229,000 251,000 268,000 285,000
kW 16.0 22.4 28.0 33.5 40.0 45.0 50.0 56.0 50.4 55.9 61.5 67.0 73.5 78.5 83.5
Power consumption kW 3.38 5.17 6.84 8.70 10.7 12.9 15.3 17.7 12.0 13.9 15.5 17.4 19.4 21.6 24.0
Casing colour Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown
Airflow rate m3/min 119 178 191 257 297 178+178 178+191 191+191 191+257
Dimensions (H×W×D ) mm 1,657×930×765 1,657×1,240×765 1,657×1,240×765 (1,657×930×765)+(1,657×930×765) (1,657×930×765)+(1,657×1,240×765)
Machine weight kg 175 185 233 276 312 175+185 185+185 185+233 185+276
Sound level dB(A) 56 57 59 60 61 65 60 61 62 63
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 5.9 6.7 6.8 7.4 8.2 8.4 11.8 5.9+6.7 5.9+6.8 6.7+6.8 6.8+6.8 6.8+7.4 6.8+8.2 6.8+8.4
Piping Liquid mm φ9.5 (Brazing) φ12.7 (Brazing) φ15.9 (Brazing) φ15.9 (Brazing) φ19.1 (Brazing)
connections Gas mm φ19.1 (Brazing) φ22.2 (Brazing) φ28.6 (Brazing) φ28.6 (Brazing) φ34.9 (Brazing)

Model RXQ32AMYM(W) RXQ34AMYM(W) RXQ36AMYM(W) RXQ38AMYM(W) RXQ40AMYM(W) RXQ42AMYM(W) RXQ44AMYM(W) RXQ46AMYM(W) RXQ48AMYM(W) RXQ50AMYM(W) RXQ52AMYM(W) RXQ54AMYM(W) RXQ56AMYM(W) RXQ58AMYM(W) RXQ60AMYM(W)
RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ14AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W)
Combination units RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ20AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ20AYM(W)
― ― ― ― ― RXQ18AYM(W) RXQ20AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ20AYM(W) RXQ20AYM(W)
Power supply 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz 3 phase 4-wire system, 380-415V/ 380V, 50Hz/ 60Hz
kcal/h 77,400 81,700 86,000 91,200 96,300 101,000 106,000 112,000 116,000 120,000 125,000 129,000 134,000 139,000 144,000
Cooling capacity Btu/h 307,000 324,000 341,000 362,000 382,000 399,000 420,000 444,000 461,000 478,000 495,000 512,000 532,000 553,000 573,000
kW 90.0 95.0 100 106 112 117 123 130 135 140 145 150 156 162 168
Power consumption kW 26.0 28.2 30.6 33.0 35.4 32.7 35.1 36.7 38.9 41.3 43.5 45.9 48.3 50.7 53.1
Casing colour Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown Without (W): Ivory white (5Y7.5/1), With (W): Metallic brown
Airflow rate m3/min 257+257 257+297 297+297 191+191+257 191+191+297 257+257+257 257+257+297 257+297+297 297+297+297
(1,657×930×765)+(1,657×930×765)+
Dimensions (H×W×D) mm (1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)
(1,657×1,240×765)
Machine weight kg 233+276 276+276 276+312 312+312 185+185+276 185+185+312 233+233+276 233+276+276 276+276+276 276+276+312 276+312+312 312+312+312
Sound level dB(A) 64 66 68 65 67 65 66 68 69 70
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 7.4+8.4 8.2+8.4 8.4+8.4 8.4+11.8 11.8+11.8 6.8+6.8+8.4 6.8+6.8+11.8 7.4+7.4+8.4 7.4+8.2+8.4 7.4+8.4+8.4 8.2+8.4+8.4 8.4+8.4+8.4 8.4+8.4+11.8 8.4+11.8+11.8 11.8+11.8+11.8
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ34.9 (Brazing) φ41.3 (Brazing) φ41.3 (Brazing)

Note: 1. Models with (W) are the outdoor units with heavy anti-corrosion specifications. Please refer to Engineering Data Book for details.
2. Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27℃DB, 19℃WB, Outdoor temp.: 35℃DB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

9 10
PVVPH1739aprv
Preview

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
Exceeding boundaries
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
with innovative energy savings
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

VRV is a trade mark of Daikin Industries, Ltd.


VRV Air Conditioning System is the world's first individual air conditioning system with variable refrigerant flow control and was commercialised by Daikin in 1982.
VRV is the trade mark of Daikin Industries, Ltd., which is derived from the technology we call "variable refrigerant volume."

•Specifications, designs and other content appearing in this brochure are current as of August 2017 but subject to change without notice.
c All rights reserved
AD. Cooling Only 60 Hz