You are on page 1of 19

TOPIC:

RETROFITTING FOR ENERGY EFFICIENCY

SUBJECT: ENERGY EFFICIENT DESIGN STUDIO

ANKITA KALE , SIDDHANT LALWANI , SEJAL MANDLECHA


PROJECT OVERVIEW Location - Reliance Mall, Garkheda, Chhatrapati
Sambhajinagar, India
Objective:
1. Reduce energy consumption in building.
2. Improve living comfort in commercial and residential space .
3. It act as a economical solution

INDIA MAHARASHTA SAMBHAJINAGAR RELIANCE MALL VIEW

Working Hours -
8:00 AM - 10:00 PM (Departmental Store)
9.00 AM - 1.00 AM (Theatre)
10.00 AM - 10.00 AM (Remaining Mall Timing)

Front Road - 24 M Wide


Front Setback - 9 M
Side And Back Setbacks - 6 M
Building is Tilted towards East

RELIANCE MALL AT SAMBHAJINAGAR


Base Case Design

Category Description

Building Type Commercial


Category Description
Total building 18035.28 SQ.M
Climate type Hot & Dry Area
Temperature Max - 45.6 C (114.0 F) on 25th May Construction • Exterior wall – 230mm thick both side
1905. plaster & colour
Minimum temp. – 24 degree C • Flat roof – 126 mm cast concrete with
50 mm screed
Diurnal Range Approx 23 degree C • Internal partitions – 150 mm thick
Humidity Mean humidity is around 56.9%, & brick wall plastered and coloured both
varies from 16.4% to 97.8%. sides.
Openings • Glass – clear glass 6 mm thk
Rainfall 725.8 mm
• Aluminium framing
Wind direction West • U value of glass-
• Window wall ratio – 8.56 %
• Skylight roof ratio - 0.94 %
Light fixtures

HVAC VAV, water-cooled chiller, Air-side HR,


Outdoor air reset
Not Conditioned 5578.53 SQ.M
Area
Conditioned Area 12456.75 SQ.M

BASE CASE
Basement floor Ground Floor

BASE CASE
First Floor Second Floor

BASE CASE
Third Floor

BASE CASE
HVAC Description ROOF Description

Base case VAV , Water – cooled chiller ,Air – Base case Rcc slab with 5 layer at all the floors
side HR, Outdoor air reset having u value 2.07

Solution case 1 Green roof on existing slab


Solution case 1 VRF (Air –cooled , Heat recovery
,DOAS, Solution case 2 Clay tiles on existing slab

Solution case 2 VRF ( Air –Cooled) , Heat Recovery


,DOAS,DCV

Area [m2]

Total Building Area 18035.28

Net Conditioned Building Area 12456.75

Unconditioned Building Area 5578.53

SIMULATION TYPES
HVAC Description

Base case VAV , Water – cooled chiller ,Air –


side HR, Outdoor air reset

Solution 1 VRF (Air –cooled , Heat recovery


,DOAS

Solution 2 VRF ( Air –Cooled) , Heat Recovery


,DOAS,DCV

Conclusions –
• VRF (Air- cooled), heat recovery, DOAS,DCV is more efficient than first two cases because –
• Gives more cooling in less energy usage
• DCV is a type of ventilation system that adjusts the amount of outdoor air brought into a
building based on occupancy and other factors.
• Main difference between the two systems is that the "VRF (air-cooled) heat recovery DOAS, DCV"
system has the capability to adjust the amount of outdoor air based on the actual needs of the
building, while the "VRF (air-cooled) heat recovery DOAS" system brings in a fixed amount of
outdoor air. This can potentially lead to better indoor air quality and energy efficiency with the DCV
system.

HVAC SIMULATION ANALYSIS


HVAC SIMULATION
ANALYSIS
(BASE CASE)
HVAC SIMULATION
ANALYSIS
(VRF (Air –cooled ,
Heat recovery
,DOAS)
HVAC
SIMULATION
ANALYSIS
(VRF ( Air –
Cooled) , Heat
Recovery
,DOAS,DCV)
ROOF Description

Base case Rcc slab with 5 layer at all the


floors having u value 2.07
Solution 1 Green roof on existing slab
Solution 2 Clay tiles on existing slab

BASE CASE
DAYLIGHT SIMULATION (BASE CASE) (TIME : 1:00 PM)
DAYLIGHT SIMULATION (BASE CASE) (TIME : 5:00 PM)
DAYLIGHT SIMULATION (BASE CASE)(TIME : 10:00 PM)
RETRIFIT PROPOSALS
PARAMETER BASE CASE SOLUTION CASE SOLUTION CASE 2 SOLUTION CASE 3 SOLUTION CASE 4 SOLUTION CASE 5
1

Wall Exterior wall – Exterior wall – Exterior wall – Exterior wall –


230mm thick both 230mm thick 230mm thick both 230mm thick both
side plaster & colour both side plaster side plaster & side plaster &
Internal partitions – & colour colour colour
150 mm thick brick Internal Internal partitions Internal partitions
wall plastered and partitions – 150 – 150 mm thick – 150 mm thick
coloured both sides. mm thick brick brick wall plastered brick wall plastered
wall plastered and coloured both and coloured both
and coloured sides. sides.
both sides.

Roof 126 mm cast 126 mm cast 126 mm cast Green roof on Clay tiles on
concrete with 50 concrete with 50 concrete with 50 existing slab existing slab
mm screed mm screed mm screed

HVAC VAV , Water – cooled VRF (Air –cooled , VRF (Air –cooled , VRF (Air –cooled , VRF (Air –cooled ,
chiller ,Air – side HR, Heat recovery Heat recovery Heat recovery Heat recovery
Outdoor air reset ,DOAS ,DOAS,DCV ,DOAS,DCV ,DOAS,DCV

Electricity

Retrofit cost
Strategies