You are on page 1of 52

METELX

TECHNOLOGIES

The Instrument Transformer Company


METELX
TECHNOLOGIES

up
power

accuracy
factor

resistance
current

voltage
electronics
stepped flow
down
winding

range
instrument see
electrical

range
transformer
magnetic
flux

equipments primary
turn

load
grounded secondary
Introduction
Metelx Technologies was established in 2006 in Lahore. The company manufactures current
and voltage transformers up-to 24 KV application, both indoor and outdoor. METELX Technolo-
gies is an ISO 9001: 2015 certified company. MeteIx's products have wide acceptance. Products
are manufactured to WAPDA/NTDC, BS, IEC, and AS standards and dimensions are to DIN stan-
dards. Products have been type-tested. The company has vast expertise in the design and man-
ufacture of current and voltage transformers for metering, protection and special protection
applications.

The manufacturing unit of the Metelx Technologies is well-equipped with manufacturing and
testing equipment. Testing of instrument transformers is done using International standard
Equipment required for this purpose

Approvals
METELX Technologies is an ISO 9001: 2015 certified company. The products manufactured are
the routine and type tested to domestic and international standards at NV & SC Lab, Rawat
Laboratory, Pakistan. The performed type-tests include short time tests, impulse tests, partial
discharge and temperature rise. Our Instrument transformers meet the requisite international
standards including stringent requirements of partial discharge.

www.metelx.com
03
Mission Values
We are a growing and profitable supplier of We value honesty, integrity and
transformers and complementary products ethical behavior in our relationships
dedicated to satisfying the collective needs with all stakeholders.
of our shareholders, customers, suppliers, We value innovation and a relentless
employees and community.
pursuit of continuous Improvement
Visions in all our processes.
We value timely decisions based on
To be the leader in our industry facts and knowledge.
by delivering: We value a team-oriented approach.
Lead times as defined by our customers We believe in treating all stakehold-
Abroad range of competitive products ers with dignity and respect.
Quality and service excellence
Technical expertise
Strong financial performance

www.metelx.com
04
Products
The company manufacture three type of instruments transformers
Medium Voltage Instrument Transformer
Medium Current Transformer (CT)
Medium Voltage Transformer (LV)
Low Voltage Current Transformers
Low Voltage WAPDA CT’s (LVW)
Low Voltage Private (LVP)
Low Voltage Split Core (LVS)
Epoxy Insulator (Bus Bar Support)
Epoxy Bushing

Instrument Transformer
Instrument Transformers is a special transformer that is used in electrical power system (Indus-
trial Area) for stepping down currents and voltages of the system for measuring, metering and
protection purpose. The primary winding of the transformer is connected to the high voltage
or high current circuit, and the meter or relay is connected to the secondary circuit.
The electrical instruments are not directly connected to the meters or control apparatus of
high voltage for safety purpose. The instrument transformers (like voltage transformer and
current transformer) are used for connecting the electrical instruments to the measuring instru-
ments. These transformers reduce the voltage and current from high value to the low value
which can be measured by conventional instruments (Non-Risky Instruments).
The measuring instrument like Ammeter, Voltmeter, Wattmeter, etc. designs for low voltages. If
the measuring apparatus connects to the high voltage lines for measurement, the devices may
get burned or damage. Thus, the Instrument transformer (CT, PT) uses for measurement.

www.metelx.com
05
Current Transformer (CT)
A Current Transformer (CT) is the principal measuring device for protection and metering
schemes in any power system. The primary current of the CT is transformed into the required
secondary current, usually 5A or 1A. Not only is the accuracy of the transformation of prime
importance, but also the isolating function. In fact there is no matter what the system voltage
on the primary circuit, the secondary circuit need to be insulated only for a low voltage.

METELX Technologies manufactures given below medium current transformer (MCT)

MCT-01 MCT-11
MCT-02 MCT-13
MCT-03 MCT-14
MCT-04 MCT-16
MCT-04B MCT-17
MCT-08 MCT-18
MCT-09 CBCT-19
MCT-10 CBCT-20

www.metelx.com
06
Potential Transformer (PT)
Potential Transformer is also known as Voltage Transfromer. It consist of primary and secondary
windings which are electrically isolated but coupled magnetically by a core. Their role in electri-
cal systems is of primary importance as they “step down” the voltage of a system to measurable
values, such as 110 V or 100 V, thus enabling Standardization of equipment
Voltage Transformer Measurement For Metering:
A voltage Transformer with typical accuracy class: 0.1, 0.2, 0.5, 1.0 and 3.0 used mainly for mea-
suring through meters and similar apparatus.
Voltage Transformer Measurement For Protection:
A Voltage Transformer with typical accuracy class 3P, 6P are used mainly for protection Relays.

METELX Technologies manufactures given below medium voltage transformer (MVT)

MVT-05
MVT-06
MVT-07
MVT-12
MVT-15
3 Phase PT

www.metelx.com
07
Low Voltage Current Transformer (LV)
METELX produces a comprehensive range of Low Voltage Current Transformer according to
International/Local Standards. A variety of designs are available to suit individual require-
ments. Ring Type (bus bar mounted) CTs with different sizes of windows are available that
provides easy mounting for any position in LV appliances. All current transformers are
constructed from high-grade material and are individually tested for compliance with the spec-
ifications. A team of qualified and experienced staff is assigned for the design and testing of
current transformers. Strict quality control is exercised to provide a reliable product.

METELX Technologies manufactures given below low voltage current transformer (LVP,LVS & LVK )

LVP-20 LVS-20X30
LVP-30 LVS-50X80
LVP-40 LVS-80X80
LVP-60 LVS-120X80
LVP-80 LVS-80X160
LVP-100 LVK-125
LVK-65
LVK-35

www.metelx.com
08
Low Voltage Current Transformer (LVW)
Having a variety of low voltage instrument current transformers METELX also manufactures
special instrument transformers for WAPDA which is used for measuring purposes. Before
copper winding on the steel core, annealing process is used to removes stress from the core,
which is critical to ensure the core will deliver optimum accuracy and minimum excitation loss.
These trasfromers are the current-sensing units of the power system and are used at generat-
ing stations, electrical substations, and in industrial and commercial electric power distribu-
tion.

METELX Technologies manufactures given below low voltage transformer (LVW)

LVW-100
LVW-200
LVW-300
LVW-400
LVW-600
LVW-800
LVW-1000

www.metelx.com
09
Epoxy Insulator And Bushing
Keeping our synchronization with the engineering development taking place in this industry,
METELX is engrossed in delivering a broad range of Epoxy Insulator. The 00KV high-voltage
insulators are made of high-quality insulating materials which have superior electrical insula-
tion performance, superior mechanical strength, and reliable dimensional stability. Epoxy
resins are widely used as insulation material in electrical and electronic applications and these
manufactured insulators are used in electrical equipment to support and separate electrical
conductors without allowing current through themselves.

METELX Technologies manufactures given below epoxy insulators

Epoxy Insulator (Bus Bar Support)


Expoxy Busshing

www.metelx.com
10
Quality
The certification to ISO 9001 ensures that established procedures are followed in all areas of
operation such as design, marketing, planning, purchase, production, inspection at all stages
and dispatch.
All designs developed are planned, reviewed, verified and completely validated by routine and
type testing to the specified standards prior to production.
Each range of products is covered by a detailed quality plan that tabulates all related activities.
All instruments used are calibrated from an ISO 17025 accredited lab with traceability to
relevant standards.
METELX technologies design, marketing, planning, purchasing and manufacturing activities
are computerized.
Our Customers repose complete confidence in our Products and services.

Testing Facilities
METELX Technologies provide given below tests for all kind of CT’s & PT’s

Accuracy Test
Temperature-Rise Test
Induced Voltage Withstand Test
Power Frequency Withstand Test
Inter-Turn Over Voltage Test
Instrument Security Test

www.metelx.com
11
Products

~ Available Shades ~

www.metelx.com
12
MCT-01
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA

25/1A to 1000/5A 0.1 M5 5 P10


to to Up-to 40 Up-to 40
50:25/1A to 1000:500/5A 1.0 M10 10 P10

188
50

220
4

137 137
150
40

155

0mm
ø14x2

120
120
20

30

274
300

www.metelx.com
13
MCT-02
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


25/1A to 1000/5A 0.1 M5 5 P10
25/1/1A to 1000/5/5A to to Up-to 50 Up-to 40
50:25/1A to 1000:500/5A 1.0 M10 10 P20

240
50
240
4

137 137
158
40

155

0mm
ø14x2

120
20

60 30

274
300

www.metelx.com
14
MCT-03
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


25/1A to 1000/5A
25/1/1A to 1000/5/5A 0.1 M5 5 P10
25/1/1/1A to 1000/5/5/5A to to Up-to 60 Up-to 40

50:25/1A to 1000:500/5A 1.0 M10 10 P20

50:25/1/1A to 1000:500/5/5A
270
50
COPPER PAD
4

137 137
150
40

120

mm
x20
ø14
120
40

20

60 30

274
300

www.metelx.com
15
MCT-04
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


1000/1A to 3200/5A
1000/1/1A to 3200/5/5A 0.1 M5 5 P10
1000/1/1/1A to 3200/5/5/5A to to Up-to 80 Up-to 40

1600:800/1A to 3200:1600/5A 1.0 M10 10 P20

1600:800/1/1A to 3200:1600/5/5A

270
90
COPPER PAD
220
211
4

141 153
170
80
220

160

190
130
40

2
M1

190
335

www.metelx.com
16
MCT-04-B
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


25/1A to 1000/5A
25/1/1A to 1000/5/5A 0.1 M5 5 P10
25/1/1/1A to 1000/5/5/5A to to Up-to 80 Up-to 40

50:25/1A to 1000:500/5A 1.0 M10 10 P20

50:25/1/1A to 1000:500/5/5A

300
60
220
4

141 153

170
40

160

230
50

130
40

2
M1
50

294
335

www.metelx.com
17
MVT-05
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA


3.3KV/√3 / 100V/√3 to 24KV/√3 / 110V/√3
3.3KV/√3 / 100V/√3, 100V/3 to 24KV/√3 / 110V/√3, 110V/3 1.0 to 0.1 3P & 6P Up-to 300

3.3KV/√3 / 100V/√3,100V/√3,100/3 to 24KV/√3 /110V/√3,110V/√3 110V/3

260

280

260
4

152 212

148

150

34 95
80

364
390

www.metelx.com
18
MVT-06
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA


3.3KV/√3 / 100V/√3 to 24KV/√3 / 110V/√3
3.3KV/√3 / 100V/√3, 100V/3 to 24KV/√3 / 110V/√3, 110V/3 1.0 to 0.1 3P & 6P Up-to 300

3.3KV/√3 / 100V/√3,100V/√3,100/3 to 24KV/√3 /110V/√3,110V/√3 110V/3

220

260
4

152 212
264

150

mm
x20
ø14
80

364
390

www.metelx.com
19
MVT-07
TECHNICAL DATA
Insulation Level Frequency International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz IEC - 61869

Ratio M Class VA

3.3KV / 100V to 24KV / 220V 1.0 to 0.1 Up-to 600

165

268
275

266
4

152 212

158
271

150

mm
x20
ø14
80

364
390

www.metelx.com
20
MCT-08
TECHNICAL DATA
Insulation Level Frequency K.E. Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


25/1A to 1000/5A
25/1/1A to 1000/5/5A 0.1 M5 5 P10
25/1/1/1A to 1000/5/5/5A to to Up-to 60 Up-to 40

50:25/1A to 1000:500/5A 1.0 M10 10 P20

50:25/1/1A to 1000:500/5/5A
260
10 90
70

70

210
214
4

137 137
300
150
R8
40
3
Ø1

40 40

R8
R8
20
25

3
Ø1

30

0.6
Ø1
20

P1 P2

155

0mm
ø14x2

10

P1 P2
120

40

www.metelx.com
21
MCT-09
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


25/1A to 1000/5A 0.1 M5 5 P10
25/1/1A to 1000/5/5A to to Up-to 50 Up-to 40
50:25/1A to 1000:500/5A 1.0 M10 10 P20

308
240
214
128
4

137 137

158
214

155
0
Ø1
120

24

274
300

www.metelx.com
22
MCT-10
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA

25/1A to 1000/5A 0.1 M5 5 P10


to to Up-to 40 Up-to 40
25/1/1A to 1000/5/5 A 1.0 M10 10 P10
258

160

60

140

80
Ø1
50

150
175
390
440

www.metelx.com
23
MCT-11
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


25/1A to 400/5A 0.1 M5 5 P10
to to Up-to 40 Up-to 30
25/1/1A to 400/5/5A 1.0 M10 10 P20

320
487

260
40
90

www.metelx.com
24
MVT-12
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA


3.3KV/√3 / 100V/√3 to 24KV/√3 / 110V/√3
3.3KV/√3 / 100V/√3, 100V/3 to 24KV/√3 / 110V/√3, 100V/3 1.0 to 0.1 3P & 6P Up-to 300

3.3KV/√3 / 100V/√3,100V/√3,100/3 to 24KV/√3 /110V/√3,110V/√3 100V/3


257
-1

M10x16
14

220

(24) 135 (15)


(148)
(45)
125
)
20

) 9

(9)

(6) (207)
(270)
<=325

www.metelx.com
25
MCT-13
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


25/1A to 800/5A
0.1 M5 5 P10
25/1/1/1A to 800/5/5/5A to to Up-to 60 Up-to 40

50:25/1A to 800:400/5A 1.0 M10 10 P20

50:25/1/1A to 800:400/5/5A
135 55
70

283
325
32
186

148
184 Gewinde gerollt M12x23mm
15 32 120 rolled thread M12x23mm
125

32
80

72 72 24
135 6
270
270

www.metelx.com
26
MCT-14
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


25/1A to 1000/5A 0.1 M5 5 P10
25/1/1A to 1000/5/5A to to Up-to 50 Up-to 40
50:25/1A to 1000:400/5A 1.0 M10 10 P20

250

185 150
148
220

148

Ø11

32 60
40

120

270

www.metelx.com
27
MVT-15
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA


3.3KV/√3 / 100V/√3 to 24KV/√3 / 110V/√3
3.3KV/√3 / 100V/√3, 100V/3 to 24KV/√3 / 110V/√3, 100V/3 1.0 to 0.1 3P & 6P Up-to 300

3.3KV/√3 / 100V/√3,100V/√3,100/3 to 24KV/√3 /110V/√3,110V/√3 100V/3

250

120

185 150
220

148

1
Ø1
125
148

270

www.metelx.com
28
MCT-16
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


1200/1A to 2500/5A 0.1 M5 5 P10
1200/1/1A to 2500/5/5A to to Up-to 60 Up-to 40
1200/1/1/1A to 2500/5/5/5A 1.0 M10 10 P20
219

153
435

148

375
24 184 Gewinde gerollt M12x23mm
120 32 rolled thread M12x23mm
9

125
70
40

70 70
Ø9

260 136
396 17

www.metelx.com
29
MCT-17
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


25/1A to 1000/5A 0.1 M5 5 P10
25/1/1A to 1000/5/5A to to Up-to 80 Up-to 60
50:25/1A to 1000:500/5A 1.0 M10 10 P20
2
219
4

153
435

148

435
24 184 Gewinde gerollt M12x23mm
32 120 32 rolled thread M12x23mm
9

125
Ø9

22 260 135 18
435

www.metelx.com
30
MCT-18
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA


1200/1A to 2500/5A 0.1 M5 5 P10
1200/1/1A to 2500/5/5A to to Up-to 60 Up-to 40
1200/1/1/1A to 2500/5/5/5A 1.0 M10 10 P20

135 52
70

283
325

70
186

148

184 Gewinde gerollt M12x23mm


32 120 32 rolled thread M12x23mm
125
80
40

Ø9

70 70 24
135 6
270

www.metelx.com
31
CBCT-19
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA

www.metelx.com
32
CBCT-20
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA

www.metelx.com
33
3Phase PT
TECHNICAL DATA
Insulation Level Frequency WAPDA Spec. International Spec.
3.6/10/40 KV to 24/50/125 KV 50/60 Hz P-44: 2018 IEC - 61869

Ratio M Class P Class VA KA

www.metelx.com
34
LVP-20
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 30/5 A 1 1.25 Product Code
LVP-20
2. 60/5 A 1 1.25
3. 100/5 A 0.5 1.25
1
Ø2

77

29

35 60

LVP-30
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 100/5 A 0.5 1.25
2. 150/5 A 0.5 1.25
3. 200/5 A 0.5 2.5 Product Code
LVP-30
4. 250/5 A 0.5 2.5
5. 300/5 A 0.5 5
6. 400/5 A 0.5 5

31.2 31.5
11.8

62.5
36

www.metelx.com
35
LVP-40
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 300/5 A 0.5 2.5
Product Code
2. 400/5 A 0.5 5
LVP-40
3. 500/5 A 0.5 7.5
4. 600/5 A 0.5 7.5

16
77.1

31.5
11

36 63

LVP-60
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 500/5 A 0.5 5
2. 600/5 A 0.5 5 Product Code
LVP-60
3. 700/5 A 0.5 5
4. 800/5 A 0.5 7.5

21
110
0

52.4
Ø5
50.5

12.5

61.5

35 85.5

www.metelx.com
36
LVP-80
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 700/5 A 0.5 5
2. 800/5 A 0.5 5 Product Code
3. 1000/5 A 0.5 10 LVP-80
4. 1200/5 A 0.5 10

127.5

80.7
13.70

50.5
60

50
30

105 36 105

LVP-100
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 700/5 A 0.5 5
2. 800/5 A 0.5 5 Product Code
LVP-100
3. 1000/5 A 0.5 10
4. 1200/5 A 0.5 10
R34

154
31.5
81

100.5
70
51

35 140

www.metelx.com
37
LVS-20x30
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 100/5 A 1.0 1.0
2. 150/5 A 1.0 1.0
3. 200/5 A 1.0 1.0
Product Code
LVS - 20x30
4. 250/5 A 1.0 1.0
5. 300/5 A 0.5 1.0
6. 400/5 A 0.5 2.5

S2 S1
P2
28

92
100

22

40
K - 30 X 20
P1

LVS-50x80
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 250/5 A 1.0 1.0
2. 300/5 A 1.0 1.0
3. 400/5 A 0.5 1.5
Product Code
LVS - 50x80
4. 600/5 A 0.5 2.5
5. 800/5 A 0.5 3.75
6. 1000/5 A 0.5 5.0

S1 S2
P1
145
152
82

40

52

K - 80 X 50
P2

www.metelx.com
38
LVS-80x80
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 250/5 A 1.0 1.0
2. 300/5 A 1.0 1.0
3. 400/5 A 1.0 1.0 Product Code
4. 600/5 A 0.5 1.5
LVS - 80x80
5. 800/5 A 0.5 3.75
6. 1000/5 A 0.5 7.50

S1 P1 S2
83

153

40
145

82

K-80 X 80
P2

LVS-120x80
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 600/5 A 1.0 1.0
2. 800/5 A 0.5 2.5 Product Code
3. 1000/5 A 0.5 5.0 LVS - 120x80
4. 1200/5 A 0.5 5.0
5. 1600/5 A 0.5 5.0

S2 P2 S1
193
123

185

40

83

K-120X80
P2

www.metelx.com
39
LVS-80x160
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 1000/5 A 0.5 5.0
2. 2000/5 A 0.5 7.5
3. 2500/5 A 5.0 15 Product Code
4. 3000/5 A 5.0 20 LVS - 80x160
5. 4000/5 A 0.5 20
6. 5000/5 A 0.5 20
7. 6000/5 A 0.5 20

196
238
162

52
82

LVK-125
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 0.5 5
2. 0.5 5 Product Code
LVK-125
3. 0.5 10
4. 0.5 10

Sealing Arrangement
186
186
125

55

S1 S2
53

P1
130
130 55

www.metelx.com
40
LVK- 65
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 0.5 5
2. 0.5 5 Product Code
3. 0.5 10 LVK-65
4. 0.5 10

Sealing Arrangement

139
65
139

55
S1 S2

P1
120

120 55

LVK- 35
TECHNICAL DATA
Sr. No. Ratio Class VA
1. 0.5 5
2. 0.5 5 Product Code
LVK-30
3. 0.5 10
4. 0.5 10

Sealing Arrangement
100
100

0
Ø3
45

S1 S2

P1
80

80 45

www.metelx.com
41
LVW-100
TECHNICAL DATA
Ratio Class VA
Product Code
100/5 A 0.5 5 LVW-100
Specification DDS:80-2007, IEC 61869

125

03
Ø1
0
Ø13
Ø3 Ø3
0 0

100/5

50 150 50

LVW-200
TECHNICAL DATA
Ratio Class VA
Product Code
200/5 A 0.5 5 LVW-200
Specification DDS:80-2007, IEC 61869

100
30
Ø1

0
Ø13
Ø5
Ø5

0
0

200/5

50 150 50

www.metelx.com
42
LVW-300
TECHNICAL DATA
Ratio Class VA
Product Code
300/5 A 0.5 5 LVW-300
Specification DDS:80-2007, IEC 61869

100

0 3
Ø1
0
Ø13
Ø5
Ø5

0
0

300/5

50 150 50

LVW-400
TECHNICAL DATA
Ratio Class VA
Product Code
400/5 A 0.5 5 LVW-400
Specification DDS:80-2007, IEC 61869

75
30
Ø1

0
Ø13 Ø6
Ø6 5
5

400/5

50 100 50

www.metelx.com
43
LVW-600
TECHNICAL DATA
Ratio Class VA
Product Code
600/5 A 0.5 5 LVW-600
Specification DDS:80-2007, IEC 61869

60

0 3
Ø1
0
Ø13

Ø7
Ø7

0
0

600/5

50 110 50

LVW-800
TECHNICAL DATA
Ratio Class VA
Product Code
800/5 A 0.5 5 LVW-800
Specification DDS:80-2007, IEC 61869

60
30
Ø1

0
Ø13
Ø7
Ø7

0
0

800/5

50 110 50

www.metelx.com
44
LVW-1000

TECHNICAL DATA
Ratio Class VA
Product Code
1000/5 A 0.5 5 LVW-1000
Specification DDS:80-2007, IEC 61869

0
Ø13
30
Ø1
Ø7

Ø7
5

5
1000/5

50 50

70

120

www.metelx.com
45
Epoxy Bus Bar Insulator

TECHNICAL DATA
Sr. No. Ratio Class VA
1.
2. Product Code
3. Insulator
4.
15

175

Ø90

45
Ø3
0

M10
M16 M20

www.metelx.com
46
Epoxy Bus Bar Insulator

TECHNICAL DATA
Sr. No. Ratio Class VA
1.
2. Product Code
3. Insulator
4.

Ø30
15
25

175

Ø90
M1
6

M10

www.metelx.com
47
Epoxy Bus Bar Insulator

TECHNICAL DATA
Sr. No. Ratio Class VA
1.
2. Product Code
3. Insulator
4.

www.metelx.com
48
Epoxy Bus Bar Insulator

TECHNICAL DATA
Sr. No. Ratio Class VA
1.
2. Product Code
3. Insulator
4.

www.metelx.com
49
Valueable Clients
Water & Power Development Authority
Peshawar Electric Supply Co. Limited (PECO)
Islamabad Electric Supply Co. Limited (lESCO)
Gujranwala Electric Power Co. Limited (GEPC0)
Lahore Electric Supply Co. Limited (LESCO)
Faisalabad Electric Supply Co. Limited (FESCC)
Hyderabad Electric Power Co. Omitted (MEPCO)
Quetta Electric Supply Co. Limited (QESCO)
Tribal Electric Supply Co. Limited (TESCO)
K-Electric Limited
Electricity Department, Government of Azad Jammu & Kashmir (AJK)
Sukkur Electric Power Company (SEPCO)

Private Sectors
Housing Societies
Textile Industries
Sugar Industries
Steel Mills
Govt. Institutions/Organization
CNS Station etc.
Export to Middle East, Far fact, Africa and South East Asia

Private Customers
SIEMENS PEMPAK
Schneider ZGL
PEL FICO ENGINEERING
TARIQ EIECTRIC (Pvt.) LTD. USMAN ENGINEERING
BILAL SWITCHGEAR Engineering (Pvt.) LTD M-TECH
M.K Engineering MICROTECH
GHAFOOR ENGINEERING TRIBROS ELECTRIC
SOUTH ASIA ELECTRICAL CONCERN KBK
GREEN T&D Find Tech
SIDDIQUE SONS Transfo Power
JEI
Company CEO Message

As the leading manufacturer of electrical equipment especially Instrument Transformersin in


Pakistan, We have a team of well-qualified and experienced Engineers who are always ready to
meet any challenging situation. Our mission is to develop a long-lasting relationship with our
suppliers and as well as with our customers by providing them the best quality of products.
Furthermore, the research and development department is linked with our design depart-
ment which is engaged in the improvement and modification of existing products and also to
come out with new products, providing timely and crucial solutions to a wide variety of indus-
trial needs.

We bring to you over 20 years of experience, combining the strength and innovation to provid-
ing superior quality, value-oriented pricing, standard as well as innovative/custom-made
design, and reliable performance upon which our reputation and success have been estab-
lished.

Last but not least, we serve this industry by offering quality products with dependable service
and ongoing support. We guarantee that working with trusted Business Partner, along with a
team of experts who are manufacturers, consultants, and service Professionals under the dedi-
cated phenomenon to meeting your specific needs.

CEO
Muhammad Khalid
HAMMAD GROUP OF COMPANIES
Head Office

METELX Manufacturers of Power 162, Muzammil Town, Opp, WAPDA


HAMMAD & Grid 19-Km, Multan Road, Lahore - Pakistan
TECHNOLOGIES Distribution Transformer Tel: 042-37510463, 37514687
infor@hammadengineering.com
Group of Companies
ISO 9005: 2008 Certified
Prepared by Transformer Reclamation Peshawar Office
Engr. Nasir Ali G.T Road Main Stop, Near Tarnab Farm
0315 6229395 Transformer Technologies &
(Pvt. Ltd.) Support Services Taru Jabba, Peshawar-KPK
Tel: 091-2964436, Fax: 091-2964437

Rana Nisar Ahmad Road, 1-Km Bhuptian Chowk


Defence Road Off Raiwind Road, Lahore, Pakistan
Tel: 042-35966161-2 www.metelx.com
Email: info@metelx.com

You might also like