You are on page 1of 1

01

COLUMN POSITIONS & GRID

1 2 3 4 5 6
Project COMMERCIAL BUILDING
4000 3435 3330 3630 1445 Client Mr. BAREEQ SAJID
6765
Date 10/08/2022 Drawn Favas
Designed AK Sheet No W02
Revision
ARCHITECT
A A
C1 C1 C C C1

2600
ENGINEERS & CONTRACTORS , KINASSERY
Mobil : 9995 607760 Email: homelineclt@gmail.com

B B
C1 C1

1410
STRUCTURAL CONSULTANT
C C
C2

5385
3975
D C1 C1 C C
D
C1 Iringallur jctn, near Hilite mall
Shafeeq Arcade, door number 10
www.catenoid.space
Mob: 09447760662

ALL DIMENSIONS ARE IN mm . U.N.O


GENERAL NOTES

1) DRAWING SHOULD BE UNDERSTOOD IN


1 2 3 4 5 6 CONJUNCTION WITH THE ARCHITECTURAL& MEP
COLUMN SCHEDULE DRAWINGS AND DISCREPANCY IF ANY SHOULD BE
BROUGHT TO NOTICE.
250 2) DRAWING SHALL NOT BE SCALED AND
ONLY WRITTEN DIMENSIONS,MEASUREMENTS
2-Ø20+1Ø16 SHALL BE FOLLOWED.
2-Ø16 3) CONCRETE - M20 GRADE AND STEEL - Fe 415 TMT
BARS U.N.O.

500
160
C 4) ALL DETAILING REQUIREMENTS ARE AS PER
2-Ø16 IS:456-2000
2-Ø20+1Ø16 5) CLEAR COVER FOR REINFORCEMENT:
Y8 TIES @ 150C/C COLUMN SCHEDULE FOOTING 50 mm
PILE CAP 50 mm
PLINTH BEAM 30 mm
200 200
BEAM 25 mm
3-Ø16 2-Ø16 COLUMN 30 mm
SLAB 15 mm
2-Ø16 C1 2-Ø16

400
400
C2 COLUMN SIZE ABBREVIATIONS
3-Ø16 2-Ø16 U.N.O - UNLESS NOTED OTHERWISE
Y8 TIES @ 150C/C Y8 TIES @ 150C/C C 250X500
TYP. - TYPICAL
C1 Ø - BAR DIAMETER
200X400
C/C - CENTER TO CENTER
C2 200X400 N.T.S - NOT TO SCALE
EQ. - EQUAL