Professional Documents
Culture Documents
WT04
WT04
03
1.3L
1019
lap splice lC lap splice lC
28Ø bar Beam 28Ø bar Beam
L/2
392
Staggered Splicing Of Bars 04
20Ø bar
lC lC
16Ø bar
(fy =Fe500)
L
>_ 1.3L
Transverse
Transverse bars
bars
Typical Lap Length Of Various Bars Transverse Reinforcement At A splice 05 NOTE: 1. Incase of more than half the bars shall
be spliced at a section, provide transverse
>/ 150mm >/ 150mm reinforcement as shown in figure 5. This spacing
shall not be considered at the section where
designed spacing of stirrups less than 150mm.
M20 - Fe 500 M25 - Fe 500 2. When more than one bar requires
splicing,it shall be ensured that the
Size Of Bar L=lap length Size Of Bar L=lap length splicing is staggered,with a minimum(c/c)
8mm 456mm 8mm 392mm separation of 1.3 times the lap length (L) as
indicated in figure 4.
10mm 570mm 10mm 490mm 3. When bars of two different diameters
12mm 684mm 12mm 588mm are to be spliced , the lap length (L)
should be based on smaller diameter bar,
16mm 912mm 16mm 784mm refer figure 2
20mm 1140mm 20mm 980mm 4. In the case of bundled bars,L can be
L/3 L/3 increased 1.1L,1.2L,1.3L for 2-bar bundles,3-bar
25mm 1425mm 25mm 1225mm bundles,4-bar bundles respectively.
L
GENERAL NOTES
ABBREVIATIONS
1) DRAWING SHOULD BE UNDERSTOOD IN CONJUNCTION WITH C
THE ARCHITECTURAL& MEP DRAWINGS AND DISCREPANCY IF DETAILS OF LAP SPLICES
ANY SHOULD BE BROUGHT TO NOTICE.
2) DRAWING SHALL NOT BE SCALED AND
U.N.O - UNLESS NOTED OTHERWISE ONLYWRITTEN DIMENSIONS,MEASUREMENTS
TYP. - TYPICAL SHALL BE FOLLOWED.
Ø - BAR DIAMETER
ALL DIMENSIONS ARE IN mm . U.N.O
3) CONCRETE - M20 GRADE AND STEEL - Fe 500 TMT
C/C - CENTER TO CENTER BARS U.N.O. Project Commercial
N.T.S - NOT TO SCALE 4) ALL DETAILING REQUIREMENTS ARE AS PER IS:456-2000
ARCHITECT