You are on page 1of 3

BOQ for Civil & Interior Work at Residential Plot

Sl No. Description Unit Quantity Rate Amount


EARTH WORK :

Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in all


1 soils over areas (exceeding 30cm in depth, 1.5 mtr in width as well as 10 sqm on plan) CUM 0
including getting out and disposal of excavated earth inside the campus with all leads and
lifts directed by Engineer-in-charge.

Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc.
2 in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and CUM 0
watering, for all leads and all lifts.
3 Diluting and injecting chemical emulsion for pre constructional antitermite treatment Litre 0
(including the cost of chemical emulsion).
FOUNDATION WORK :

Providing and laying plain cement concrete of specified grade as bed concrete under
4 foundation upto 1 mtr deep, machine equipments, column footing, below road and 0
pathways, below floor consolidated and cured by covering with hessian cloth/ponding etc.
complete including finishing the top surface to receive the next course / layer as per
specification and drawing including the cost of centering and shuttering.
a 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm and down gauge) CUM 0
b 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm and down gauge) CUM 0
Reinforcement :
5 Providing & laying mild steel reinforcement KG 0
BRICK WORK :

6 Providing and laying FPS (Red) brick wall in 230mm of class designation 100 in cement CUM 0
mortar 1:6 (1 cement : 6 coarse sand) including raking of joints to 12mm depth, cleaning and
curing for 7 days etc complete. Including scaffolding, staging etc. complete and as directed.

7 Providing and laying FPS (Red)half brick wall in 115mm of class designation 100 in cement SQM 0
mortar 1:6 (1 cement : 6 coarse sand) including raking of joints to 12mm depth, cleaning and
curing for 7 days etc complete. Including scaffolding, staging etc. complete and as directed.

Protection on terrace and deck Waterproofing: Providing and laying, over waterproofing
8 courses average 75mm thick CC screed 1:2:4 (1 cement : 2 coarse sand : 4 graded stone SQM 0
aggregate 20 mm and down gauge) in required slope.
PLASTER WORK 0

Internal Plaster: Providing & laying 12 mm-15mm thick cement plaster to walls columns,
9 piers etc. in cement mortar 1:2:2 (1 cement : 2 fine sand: 2 coarse sand ) on plain & rough SQM 0
side of wall or R.C.C. surface rate shall include for curing, racking joints, hacking, scaffolding,
for all levels and heights complete as directed.

External Plaster: Plastering for external surfaces with base coat of 12 mm thick in cement
10 mortar 1:4 (1 cement : 4 coarse sand) mixed with waterproofing compound (CICO/Dr. Fixit or SQM 0
equivalent) in proportion as recommended by the manufacturer in external surface and
shafts etc including racking joints hacking, curing, scaffolding etc complete for all heights &
levels and finishing coat of 8 mm thick in cement mortar 1:4 (1 cement : 4 sand) using 50%
coarse sand and 50% fine sand mixed with waterproofing compound in proportion as
recommended by the manufacturer in external surface and shafts etc.

Providing & laying 6 mm thick cement plaster to ceilings in cement mortar 1 :3 (1 cement : 3
11 fine sand ) on R.C.C. surface including curing, hacking, scaffolding etc. complete for all levels SQM 0
and heights.

WOODWORK & HARDWARE

Providing and fixing factory made 38mm thick single leaf door finish with laminate. The
shutter made of Factory made 35 mm thick flush door shutter, exterior grade phenol
formaldehyde (PF) resin bonded, BWR grade, conforming to IS:2202 (Part-I), solid core block
12 board construction of approved manufacturer finished with 1.5 mm thick laminate of SQM 0
approved make and shade fixed in pattern to both faces to make overall thickness of shutter
as 38mm with second class 6mm thick teak wood lipping all around, cutting rebate in shutter,
including Stainless steel ball bearing hinges (6No.for one shutter) of approved make, 5
Knuckle, 2 ball bearing butt hinges of size 102x76x3mm, in SS304 grade fixed on steel door
frames as per Detail with S.S. screws of approved make etc., complete all floor height and
floor level, all including Dead Lock, Pull Handle etc, drawing detail and direction of Engineer-
In-Charge.
STONE & TILES WORK

Providing and fixing dry cladding for all heights with 30mm thick Gang Saw cut Granite
stone, cut-to-sizes making chamfers/grooves etc. factory finished as per approved drawings
13 of approved colour, texture and quality in External wall dry cladding using Stainless steel SQM 0
clamps of 5mm thick having grade 304 of approved make, anchor bolts / fasteners of
approved make (Clamps & Fasteners shall be paid separately), maintaining grooves at the
junction of stone panels as per approved drawing including drilling , anchoring , making
holes for fixing clamp pins , scaffolding , edge polishing, chamfering etc. complete as per
direction of Engineer-in-charge

Providing and Fixing Vitrified tiles of sizes 800mmx400mm (thickness to be specified by the
manufacturer) in external facade, with water absorption less than 0.08% and conforming to
14 IS: 15622, of approved brand & manufacturer in all colours and shade in skirting, wall SQM 0
facade, laid with cement based high polymer modified quick set tile adhesive (water based)
conforming to IS: 15477, in average 6 mm thickness, including grouting of joints. The item
includes grouting in joint and groove with 6mm wide PVC Spacer of approved make to match
the complete wall facade all complete in all respect etc. at all floor level, as per approved
drawing and direction of Engineer-In-Charge.

Providing and laying Granite stone work in flooring, landing and tread of steps in required
15 design and patterns, in linear as well as curvilinear portions of the building all complete as SQM 0
per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base
of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and
pointing with white cement slurry admixed with pigment of matching shade including
rubbing , curing, mirror polish and horned finish etc. all complete as specified and as
directed by the Engineer-in-Charge.
Providing and fixing 18mm thick granite stone of approved colour, shade, pattern,
texture for kitchen platforms, vanity counters, window sills, facia and similar locations
of required size, approved shade, colour & texture laid over 20 mm (average) thick
base of cement mortar 1:4 (1 cement : 4 coarse sand) and joint treated with white
16 cement mixed with matching pigment, epoxy touch ups including rubbing, curing, SQM 0
edge moulding and polishing to edges to give high gloss finish etc. all complete at all
levels per approved drawing and direction of Engineer-in-charge.

Interior :

Providing and fixing 12.5 mm thick Gypsum board false ceiling in horizontal/vertical and
curved surfaces, coffers coves etc. at all height including providing and fixing of frame work
17 made of special sections, power pressed from M.S. sheets and galvanized with zinc coating SQM 0
including jointing and finishing to a flush finish of tapered and square edges of the board
with recommended jointing compound , jointing tapes , finishing with jointing compound in 3
layers covering upto 150 mm on both sides of joint and two coats of primer suitable for
board, all as per manufacturer's specification and also including the cost of making openings
for light fittings, grills, diffusers, cut-outs made with frame of perimeter channels suitably
fixed, all complete as per drawings
18 Providing & Laying POP False Ceiling SQM 0
EXTERNAL TEXTURE PAINT & INTERNAL PAINT :

Providing and applying on external walls of ESTONIA of Acropaint make or approved


19 equivalent with Ceramic & Silicone technology, Ultra Violet resistant in approved shade SQM 0
including acrylic Sealer in desired shade as base coat, Covering up of hairline cracks wherever
required with acro Putty after that application of Estonia with ceramic & silicone as per
desired shade with Spray Gun and application of Protective Layer of Acro Pure as top coat.
20 Providing and applying plaster of paris putty of 2 mm thickness or as required over plastered SQM 0
surface to prepare the surface even and smooth complete.

21 Providing and applying of painting with premium acrylic emulsion paint 2or more coats of SQM 0
interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of
approved brand and manufacture in approved shade and color including applying additional
coats wherever required to achieve even shade and color and all complete for all floor
heights as per approved drawing and direction of Engineer-In-Charge.

TOTAL in INR 0