You are on page 1of 4

320D & 320D L Excavators PHX00001-UP (MACHINE) POWERED ... https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?return...

Bienvenido: r080jdr
Producto: EXCAVATOR
Modelo: 320D L EXCAVATOR PHX
Configuración: 320D & 320D L Excavators PHX00001-UP (MACHINE)
POWERED BY C6.4 Engine

Localización y Solución de Problemas


Product Link 121S/300
Número de medio -RENR7911-13 Fecha de publicación -01/10/2014 Fecha de actualización -19/09/2016

i05662643

Event Code List


SMCS - 7569

Event codes alert the operator or the technician that an abnormal operating condition exists in one of the
machine systems.

When an Electronic Control Module (ECM) activates an event code, the operator or the technician will be
alerted by the Messenger. Most active events will be logged by the ECM. Some events are active only. Active
only events are not logged. The events that are active and the events that are logged can be viewed with the
following equipment:

Messenger

Caterpillar Electronic Technician (Cat ET)

Warning Levels
The ECM will assign a warning level to an active event code. Event codes are one of three levels. The level is
according to the severity of the abnormal condition. Each warning level requires a specific response from the
operator. The warning levels and the required operator response are listed below.

Warning Level 1

Warning level 1 alerts the operator that a machine system requires attention. The operator should check that
the involved system condition or the operator should perform maintenance on the involved system at the
earliest possible time.

Warning Level 2

Warning level 2 requires changing the operation of the machine or performing a maintenance procedure.
Failure to correct a problem that caused this warning may result in damage to the components involved in the

1 of 4 5/28/2018, 5:53 PM
320D & 320D L Excavators PHX00001-UP (MACHINE) POWERED ... https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?return...

system.

Warning Level 2S

Warning level 2S requires an immediate change in machine operation in order to avoid possible damage to
the system.

Warning Level 3

Warning level 3 requires an immediate safe shutdown of the machine in order to avoid damage to the
machine or injury to personnel around the machine. The problem that caused the event must be corrected
before machine operation can resume.

Indications and System Response


Caterpillar Electronic Technician (Cat ET) Service Tool

When an abnormal operating condition occurs, the status screen on the Cat ET indicates that there is an active
event.

Event codes are displayed on Cat ET in the following format:

EXXXX Description of the code

The "E" means that the code is an event code. The "XXXX" is a numeric identifier. The numeric identifier is
followed by a description of the code.

Active event codes are listed in ascending numerical order. The code with the lowest number is listed first.
The active event code is removed from the list when the condition is no longer present.

Logged Event Codes

Some event codes are logged in the ECM memory. Some event codes are active only. The logged event codes
are listed in chronological order. The most recent code is listed first.

A logged code is cleared from memory when one of the following conditions occur:

The service technician manually clears the code.

The code does not reoccur for 1000 hours.

A new code is logged and there are already ten logged codes in memory. In this case, the oldest logged
code is cleared.

Note: Always clear logged event codes after investigating and correcting the problem which generated the
code.

List of Event Codes

2 of 4 5/28/2018, 5:53 PM
320D & 320D L Excavators PHX00001-UP (MACHINE) POWERED ... https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?return...

The following table lists event codes and the recommended responses. Use the Cat ET service tool in order to
determine the event codes that are active or logged.

Table 1
List of Event Codes (EID)

EID Level Description Possible Cause and Recommended Response

In a PL321 system using sync-clock and Product Link is not the


master ECM, the Product Link module will automatically sync to the
Synchronized
master ECM hours if the difference is not greater than 50 hours. If
clock notification
861 1 the difference is greater than 50 hours, a diagnostic will be generated
of manual synch
in Cat ET that indicates that a manual sync is required. In that
required
instance, sync the hours. In Cat ET, use "Service/Synchronize Service
Meter Hours".

Inclusion Geo- Inclusive Geo-Fence sets up a "virtual fence" around a work site.
2131 2 Fencing boundary Once Inclusive Geo-Fence is activated, a report is generated if the
violated machine leaves the work site area. No repair or service is required.

Exclusion Geo- Exclusive Geo-Fence sets up a "virtual fence" around areas that the
2132 2 Fencing boundary machine is not allowed to enter. A report is generated if a machine
violated enters a restricted area. No repair or service is required.

Time Based Fence allows the owner of a machine to choose the time
Time-Fencing that a machine can be operated. A report is generated if the machine
2133 2
boundary violated is operated outside of the time that is set for machine operation. No
repair or service is required.

The Product Link PL300 has four additional inputs that can be
Switched Sensor
configured in order to monitor switches on the machine. These inputs
630 2 #1 trip condition is
can be configured by using Caterpillar Electronic Technician (Cat ET
activated
service tool). Troubleshoot input as setup by the dealer.

The Product Link PL300 has four additional inputs that can be
Switched Sensor
configured in order to monitor switches on the machine. These inputs
631 2 #2 trip condition is
can be configured by using Caterpillar Electronic Technician (Cat ET
activated
service tool). Troubleshoot input as setup by the dealer.

The Product Link PL300 has four additional inputs that can be
Switched Sensor
configured in order to monitor switches on the machine. These inputs
632 2 #3 trip condition is
can be configured by using Caterpillar Electronic Technician (Cat ET
activated
service tool). Troubleshoot input as setup by the dealer.

The Product Link PL300 has four additional inputs that can be
Switched Sensor
configured in order to monitor switches on the machine. These inputs
633 2 #4 trip condition is
can be configured by using Caterpillar Electronic Technician (Cat ET
activated
service tool). Troubleshoot input as setup by the dealer.