L A B 4 . 5 0 D E H Y D R AT O R
F O R W AV E G U I D E S A N D C O A X I A L C A B L E S

key features
 output pressure programmable up to 50 kPa
 flow rate up to 300 l/h
 dew point better than -45 °C
 two pumps and two drying chambers running alternatively
 continuous duty and automatic operation
 drying chambers automatic regeneration
 microprocessor control and monitoring with digital display
 low/high pressure, high humidity, power and system failures alarms
 local and remote alarm signaling
 optional remote control through SNMP protocol and WEB browser or
through serial link
 optional digital flowmeter for air flow measurement
 output pressure, hour meter, alarms readout
 low power consumption and low acoustic noise
 wide-range power supply: both 110-240 VAC 50/60 Hz and 48/60 VDC
always available
 high reliability and long life
 mounting flexibility: wall, floor, 19” and ETSI N3 racks
description
The LAB4.50 dehydrator provides continuous dry air The following devices are available on the front panel:
flow up to 300 l/h with a dew point better than  monitoring digital display
 function keyboard to scroll and modify settings
-45°C. Output pressure can be set in the range from
 power on and alarms LED
10 kPa to 50 kPa.  on/off outlet valves

The LAB4.50 achieves reduced mechanical wear and Output air pressure, hour meter, active alarm
noise and therefore a long lifetime by output pressure messages, output pressure setting and alarm
thresholds are available on the digital display.
measurement, microprocessor control and pump
The basic version has low pressure, high pressure,
speed regulation. Pumps speed control avoids
high humidity, power and system failures alarms. The
mechanical pressure regulators eliminating alarms are remotely signaled by one SPDT relay.
undesirable pressure losses and a worse response to
As option are available:
plant air flow regulation.  remote control through SNMP protocol and HTTP
WEB browser by an Ethernet interface,
Two drying chambers contain the desiccant and dry
 remote control by a RS485/RS422 or R232 serial
airstream by adsorption process. The chambers link,
operate on alternate cycles so while the first chamber  digital flowmeter with data showed on the display
dries, the second one regenerates the desiccant by On the rear panel are available the AC and DC power
supply connectors, the connector for remote alarm
heating and backwashing with a small reverse dry air
and the optional RJ45 connector for Ethernet interface
flow.
or D-Sub 9 pins for serial link.
This technology reduces overall power consumption. The LAB4.50 always includes wall, floor, 19” and ETSI
N3 rack mountings.

pneumatic scheme

 DRYING CHAMBER

 HEATER

 PUMP

 AIR BACKWASHING HOLE

 HUMIDITY PROBE

 DIGITAL PRESSURE GAUGE

 RELIEF VALVE

 SHUT OFF VALVE

 DRY AIR OUTLET


performance
Output pressure : factory set at 20 kPa
programmable from 10 kPa to 50 kPa
Maximum flow rate : 300 l/h
Safety valve : built in, factory set at 70 kPa
Output air dew point : better than -45°C at 80% RH at 20°C
Regeneration : automatic by heating
Local alarms : low pressure, high pressure, high humidity, power
and system failures alarms
Remote alarms : all the alarms are remotely signaled by SPDT relay
Optional remote monitoring interface Web Browser and SNMP, others on request
Optional measures : air flow by a digital flowmeter
LED indications : power on, alarms
Readouts : output pressure, low/high pressure alarm thresholds,
hour meter
European Community Directives : 2014/35/EU “Low Voltage Directive”
2014/30/EU “Electromagnetic Compatibility Directive”
2015/863/UE Environmental compliance (RoHS3)
Safety Normative : EN 62368-1
Electromagnetic Compatibility Normative : EN 55032; EN 55024

electrical specifications
Power supply : both 110-240 VAC 50/60 Hz and 48/60 VDC always
available
Power consumption
Average : < AC: 60 VA, DC: 35 W
Max during regeneration phase : < AC: 100 VA, DC: 60 W

mechanical and environmental characteristics


Temperature °C (°F)
Operating : -10 to + 50 (+14 to +122)
Storage : -30 to + 60 (-22 to +140)
Mountings : Wall, floor, 19” and ETSI N3 racks
Acoustic noise :  50 dBA at 1 m far and 1,5 m height
Dimensions mm (in)
Wall and floor mounting : width 487 (19.2)
height 132 (5.2)
depth 360 (14.2)
19” rack mounting : height 3U
depth 260 (10.2)
ETSI – N3 mounting : height 6U
depth 260 (10.2)
Weight kg (lb) : about 9 (30)
Standard outlets : 6 outlets, each with ON/OFF valve
Outlets fitting mm (in) : 9,5 (3/8”) diameter, others on request
LAB4.50

The equipment illustrated are fully equipped versions. CIBRED SUD reserves the right to modify without notice characteristics and data supplied herein.
Via Catania 2  00041 Albano Laziale Loc. Pavona (RM) - Italy
T el. +3 9 0 6 93 4 40 0 9  Fax + 3 9 0 69 3 44 0 35
ww w.c i bre d .c om  e - m ail : c i bre d @c i bre d .c om