You are on page 1of 1

Technical data sheet

MembranaVaxo®XL

Tolerance
Characteristic Testmethod Unit Result
Min. Max.
Lenght EN1848-2 m 50 0 +0,5
Width EN1848-2 m 1,5 -0,005 +0,005
Straightness EN1848-2 - Pass - -
Mass per unit area EN1848-2 g/m2 110 -15 +15
Thickness EN1848-2 mm 0,6 -0,2 +0,2
Reaction to fire(free-hanging) EN11925-2 class F - -
Resistance to water penetration EN1928A class W1 - -
Water vapour transmission
ENISO12572C m 0,03 -0,015 +0,015
Properties
Resistance to penetration of air EN 12114 m3/(m2xhx50Pa) Max0,05 - -

Tensile properties: MD265 -60 +60


EN12311-1 N/50mm
Maximum tensile force CD180 -60 +60
MD95 -70 +70
Tensile properties: elongation EN12311-1 %
CD110 -60 +60

Resistance to tearing MD165 -55 +55


EN12310-1 N
(nail shank) CD225 -75 +75
Dimensional Stability EN1107-2 % 2 - -
Stability at low temperature EN1109 °C -40 - -
Elongation MD50 -25 +25
%
EN13859-1annexC CD60 -25 +25
Artificial ageing by long term MD230 -55 +55
Tensile strength
exposure to the combination N/50mm
EN13859-1annexC CD130 -40 +40
Of UV radiation and elevated
Temperature at (80°C) Resistancetowater
penetration class W1 - -
EN13859-1annexC
Water vapour transmission
Lyssy g/m2 x24h 1400 -200 +200
23°C/85%RH
Water vapour transmission
Lyssy g/m2 x24h 3200 -400 +400
38°C/90%RH
The above product technical datasheet will be valid from 01.01.2019
Bielsko Biała,
Place and date of issue 8.06.2018