POLYETHYLENE FOIL FOR WATER VAPOR 07

MOVEMENT REGULATION – TYPE A

Difol
PN-EN 13984:2013
Difol is a flexible product of plastic which function is to regulate water vapor movement through walls,
floors or roofs.

DECLARED PERFORMANCES:
Harmonized technical specification
PN-EN 13984:2013
Use Type of plastic
Vapour control layer – TYPE A LDPE

Value
Properties Testing method Unit
DIFOL DIFOL DIFOL DIFOL DIFOL
0,15 0,20 0,30 0,40 0,50
Normative part
PN-EN 1928
1. Watertightness (2kPa) - Pass
met. A
2. Resistance to impact PN-EN 12691 met. B mm NPD
Water vapour resistance
PN-EN 1296
Durability

after artificial ageing -


3. PN-EN 1931 Pass
(70°C/12 weeks)
Chemical resistance PN-EN 1847 -
MD 30 40 70 90 100
4. Resistance to tearing PN-EN 12310-1 N
TD 30 40 70 90 100
MD 50 60 90 100 120
5. Joint strength PN-EN 12317-2 N
TD 50 60 90 100 120
6. Water vapour resistance PN-EN 1931 2
(m *s*Pa)/kg 5*1011± 35%
MD 45 60 90 120 150
7. Tensile strength N/50mm
TD 35 45 70 90 115
PN-EN 12311-2
MD ≥ 100
8. Elongation at break %
TD ≥ 100
9. Reaction to fire PN EN ISO 11925-2 - Class F
10. Dangerous substances - - No dangerous substances
Information part
0,15 0,20 0,30 0,40 0,50
11. Thickness PN EN 1849-2 mm
(± 30%) (± 30%) (± 30%) (± 30%) (± 30%)
Resistance to impact * m (20-100) ± 2%
Dimensions

Width * m (5-12) ± 5% (5-8) ± 5% (5-6) ±5%


12. PN-EN 1848-2
Deviation from rectilinearity no more
Rectilinearity - than 60mm for 10m of the product length
13. Visible defects PN-EN 1850-2 - Lack of visible defects

RULES OF ASSEMBLY
The condition of effectiveness of thermal insulation and durability of a wooden construction is protection
against moisture. Vapor insulation film DIFOL is intended to build barriers which regulate water vapor
movement from usable spaces of a building to installation spaces of a roof, a ceiling or a wall. DIFOL film
is installed from the inside of the room. Strips of film are placed parallelly with an overlap of min. 10 cm
and connected to each other what ensures tightness. They are fastened directly to the rafter or the load-
bearing structure with staples or nails. The film may directly contact the thermal insulation. It is recom-
mended to leave a gap between the film and the building. It is recommended to use pressure bars
(counterlaths). OBR S.A. brand

Notes:
l The above rules are of general nature. Detailed technical solutions should be included in the technical
WARTER Polymers Sp. z o.o.
project.
ul. Koralowa Street 60
l The condition of proper indoor humidity at limited water vapor transmission is to ensure sufficient
gravity ventilation. 02-967 Warszawa
www.warterpolymers.pl

Rolls of the product should be stored in original wrappings in roofed spaces or in natural conditions with Department:
protection against direct influence of UV rays or precipitation. Transport with covered means of transport, ul. Otolińska Street 25
protecting against mechanical damages and movement during transportation, in accordance with 09-407 Płock
applicable law regulations. tel./faks: 24/ 365 39 17