You are on page 1of 7

Booster Compressor Instrument Setpoints

Check by : Dat_EI Date: 31March2023

Tag Normal
Name Description Setpoint Value Unit value unit value Note
Sec Vent Flow - 1/2 Buff Flow
FT5108 Buffer Air Flow (Suction) HH > 0.142 scm/m >5.0 scfm

Buffer Air Flow Sec Vent Flow - 1/2 Buff Flow


FT5109 (Discharge) HH > 0.142 scm/m >5.0 scfm

Secondary Seal Vent


FT5165 Flow (Suction) HH 0.99 scm/m 35 scfm 7.17
Secondary Seal Vent
FT5175 Flow (Discharge) HH 0.99 scm/m 35 scfm 3.59

LT3100 Lube Oil Tank Level L 49.1 cm 19.32 inch


LL 43 cm 16.93 inch
H 60.3 cm 23.74 inch

LT4000 Seal Gas Filter H 12.7 cm 5 inch


Coaslescer Level HH 15.24 cm 6 inch

PCV1030 Exhaust Collector Drain 0.34 barg 5 psi

PCV1031 Exhaust Collector Drain 0.34 barg 5 psi

PCV2151 Torch Coarse Regulator 2.41 barg 35 psi

PCV2152 Torch Fine Regulator 0.69 barg 10 psi

Main Lube Oil Pressure


PCV3200 Control 2.41 barg 35 psi

PCV5100 Buffer Air Regulator 1.24 barg 18 psi

Differential
PCV5150 Seal Gas Regulator 1.38 bard 20 psi Regulator

Seal Gas Booster Pump


PCV5980 Reguator 5.5 - 6.9 barg 80-100 psi

PCV6410 Instrument Air Regulator 6.21 +/- 0.34 barg 90+/- 5 psi

PDS1500 Flameout Protection HH 0.138 incr bard 2 incr psi

PDS6210 Enclosure Inlet Filter H -2 inch H20

Enclosure Vent Fan


PDS6211 Running Feedback LL 0.00124 bard 0.5 inch H20

PDT3100 Lube Oil Tank Vent H 0.021 bard 8.5 inch H20
Pressure HH 0.0248 bard 10 inch H20

PDT3240 Lube Oil Filter DP H 2.07 bard 30 psi

Seal Gas Coaslescer


PDT4000 Filter DP H 0.55 bard 8 psi

PDT4410 Compressor Suction H 0.96 bard 14 psi


Strainer DP HH 1.24 bard 18 psi

PDT5100 Buffer Air DP L 1.03 bard 15 psi


LL 0.9 bard 13 psi

PDT5104 Buffer Air Filter DP H 2.07 bard 30 psi


Booster Compressor Instrument Setpoints
Check by : Dat_EI Date: 31March2023

Tag Normal
Name Description Setpoint Value Unit value unit value Note
PDT5130 Seal Gas Filter DP H 1.38 Delay 10Sec bard 20 psi

PDT5150 Seal Gas DP L 0.48 bard 7 psi


LL 0.28 bard 4 psi

PDT6180 Enclosure DP L 0.00062 bard 0.25 Inch H2O If Fire system


Inhibit only
LL 0.00037 Delay 30Sec bard 0.15 Inch H2O alarm

PDT6310 Turbine Air Inlet Filter H 0.012 bard 5 Inch H2O


DP HH 0.0174 bard 7 Inch H2O

PS3150 Pre/Post Pump Check 0.83 +/- 0.007 incr barg 12+/-1 psi
0.62 decr barg 9 psi

PS3170 Backup Pump Check 0.83 +/- 0.007 incr barg 12+/-1 psi
0.62 decr barg 9 psi

PS3200 Backup Pump Activation, 0.55 decr barg 8 psi


PLC Failure 0.69 incr barg 10 psi

PS4401 Compressor Case 0.28 decr barg 4 psi


Pressurized 0.55 incr barg 8 psi

PS6610 CO2 Release Confirm 1.38 barg 20 psi

CO2 Primary Release


PS6611 Confirm 1.38 barg 20 psi

CO2 Extended Release


PS6621 Confirm 1.38 barg 20 psi

Main Lube Oil Pump


PSV3110 Relief 10.34 barg 150 psi

PSV6410 Instrument Air Relief 6.9 barg 100 psi

PT2120 Gas Fuel Pressure H 34.47 barg 500 psi


HH 34.82 barg 505 psi

PT2121 Gas Fuel Valve Check H 34.47 barg 500 psi


HH 34.82 barg 505 psi

PT2126 Gas Fuel Upstream H 34.47 barg 500 psi


Pressure HH 34.82 barg 505 psi

PT2130 Gas Fuel Manifold 1 H 0.55 barg 8 psi Only before start

PT2131 Gas Fual Manifold 2 H 0.55 barg 8 psi Only before start

PT3200 Main Lube Oil Header


Engine Running
Pressure L 1.86 barg 27 psi

Engine Running
LL 1.72 barg 25 psi

Engine Running
H 3.1 Delay 30Sec barg 45 psi
Engine not
H 1.24 Delay 30Sec barg 18 psi running
Engine not
LL 0.55 Delay 05Sec barg 8 psi running
Booster Compressor Instrument Setpoints
Check by : Dat_EI Date: 31March2023

Tag Normal
Name Description Setpoint Value Unit value unit value Note

PT4410 Suction Pressure L 26 barg 261.06 psi


LL 21 barg 232 psi

PT4430 Discharge Pressure H 108 barg 1566.4 psi


HH 112 barg 1624.4 psi CDNL
HH 117.2 barg 1700 psi FSLO

PT5160 Primary Seal Vent H 0.55 barg 8 psi


Pressure (Suction) HH 1.38 Delay 5Sec barg 20 psi

PT5170 Primary Seal Vent H 0.55 barg 8 psi


Pressure (Discharge) HH 1.38 barg 20 psi

Seal Gas Boost Pump


PT5980 Leakage H 0.55 barg 8 psi

PT6400 Instrument Air Supply L 5.5 barg 80 psi


H 13.8 barg 200 psi

TE1260 Gas Producer Thrust H 115.5 C 240 F


Bearing HH 121.1 C 250 F
H Header Temp + 50 C 90 F
HH Header Temp + 55.5 C 100 F

TE1270 Power Turbine Thrust H 115.5 C 240 F


Bearding HH 121.1 C 250 F
H Header Temp + 50 C 90 F
HH Header Temp + 55.5 C 100 F

TE2120 Gas Fuel Temperature H 93.3 Delay 10Sec C 200 F


HH 101.6 Delay 120Sec C 215 F
HH 121.1 Delay 0.1Sec C 250 F
Lube Oil Tank
TE3100 Temperature L 11.1 C 52 F Start Permissive

TE3200 Lube Oil Header L 43.3 C 110 F Above 65%NGP


Temperature H 71.1 C 160 F Above 65%NGP
HH 73.8 C 165 F Above 65%NGP
HH 79.4 C 175 F up to 65%NGP

TE3510 #1 Bearing Drain H Header Temp + 25 C 45 F


Temperature HH Header Temp + 28 C 50 F

TE3520 #2 & #3 Bearing Drain H Header Temp + 61 C 110 F


Temperature HH Header Temp + 69 C 125 F

TE3540 #4 & #5 Bearing Drain H Header Temp + 25 C 45 F


Temperature HH Header Temp + 28 C 50 F

TT4002 Seal Gas Heater L 73.8 C 165 F Changed on


Temperature LL 60 After case pressurized C 140 F 16/11/2013
H 93.3 C 200 F
HH 100 C 212 F

TE4414 Compressor Suction H 115.5 C 240 F


Journal Bearing - Lower HH 121.1 C 250 F
Pad
TE4417 Compressor Inboard H 121.1 C 250 F
Thrust Bearing - Lower HH 126.6 C 260 F
Pad
TE4413 Compressor Suction H 115.5 C 240 F
Journal Bearing - Upper
Booster Compressor Instrument Setpoints
Check by : Dat_EI Date: 31March2023

Tag Normal
Name Description Setpoint Value Unit value unit value Note
Journal Bearing - Upper HH 121.1 C 250 F
Pad
TE4433 Compressor Discharge H 115.5 C 240 F
Journal Bearing - Upper HH 121.1 C 250 F
Pad
TE4418 Compressor Inboard H 121.1 C 250 F
Thrust Bearing - Upper HH 126.6 C 260 F
Pad
TE4430 Compressor Discharge H 160 C 320 F
Temperature HH 170 C 338 F

TE4434 Compressor Discharge H 115.5 C 240 F


Journal Bearing - Lower HH 121.1 C 250 F
Pad
TE4437 Compressor Outboard H 121.1 C 250 F
Thrust Bearing - Lower HH 126.6 C 260 F
Pad
TE4438 Compressor Outboard H 121.1 C 250 F
Thrust Bearing - Upper HH 126.6 C 260 F
Pad
TE6110 Enclosure Temperature H 75 C 167 F
Active SD when
Fire system
HH 85 C 185 F Auto

Enclosure Temperature Fire detected


TS6540 Switch 163 C 325 F shutdown

Enclosure Temperature Fire detected


TS6541 Switch 163 C 325 F shutdown

Enclosure Temperature Fire detected


TS6542 Switch 163 C 325 F shutdown

Enclosure Temperature Fire detected


TS6543 Switch 163 C 325 F shutdown

Enclosure Temperature Fire detected


TS6544 Switch 163 C 325 F shutdown
This list only contains alarm and shutdown list suitable for process operator to monitor and alert of EGC
Check by: Dat-EI Date: 31March2023

LUBE
TAG DESCRIPTION ALARM S/D UNITS NOTE
RT327-1 Brg1 Drain Temp Hdr Temp +25 - DegC
RT327-2 Brg2/3 Drain Temp Hdr Temp +61 Hdr Temp+69 DegC
RT327-4 Brg4/5 Drain temp Hdr Temp +25 - DegC
RT380 Lube Oil Header Temp 43 Low Alarm 74 High DegC
68 High - DegC
TL388 Lube Oil Tank Level 43.2 Low 40.6 Low cm
55.9 High - cm
TP380 Lube Oil Hdr. Pr. 1.86 Low 1.03 or 1.72 Delay 5 Sec Barg upto 70.637% NGP
1.86 Low 1.72 Low Barg Above 70.637% NGP
TPD324 Lube Oil Tank Vent Pr. 0.586 High 0.689 High Bard
TPD397 Lube Oil Filter 2.07 High Bard

Fuel
TAG DESCRIPTION ALARM S/D UNITS NOTE
RT389 Gas Fuel Temp. 85 Delay 10 Sec High 96 Delay 120 Sec DegC
or 121 Delay 0.1 Sec
TP342-1 Gas Valve Check 27.58 27.92 Barg
TP386 Gas Fuel Pr. 27.58 27.92 Barg
TP341 Instrument Air Pr. 5.5 - Barg
TP389 Fuel Control Upstream Pr. 27.58 27.92 Barg
T5 Temperature Delayed AL/SD >765.5 Delay 10Sec >765.5 Delay 20Sec DegC SetPoint-765.5
T5 Temp. Inst. S/D - 815.5 DegC
T5 Temp. Single Sensor High - 982 DegC
T5 Single T5 Sensor Higher than Avg 93.3 Delay 5 Sec - DegC
Ngp Over Speed - 102.5 % 100 % Speed=15200rpm
Ngp Under Speed - 76 % 20 Sec Delay Arm after Starter dropout
Ngp Back-Up Overspeed - 108 %
Ngp Failed to accelerate - <70 % 420 sec delay after ignition
Npt OverSpeed - 105 % 100 % Speed=12000rpm
Npt Under Speed - 42 % During running or When Compressor Unloaded
Npt Fail To Breakaway - 5 % At Ngp 65%
EGF388 Gas Fuel Valve FB Pos. Fail 10 % 2 Sec Delay 10% difference between Cmd & FB

Temperature/Vibration Compressor Turbine


TAG DESCRIPTION ALARM S/D UNITS NOTE
TV360Y/X HP Cmpr. Fwd Y & X axis 50.8 63.5 Micron
TV361Y/X HP Cmpr. Aft Y & X axis 50.8 63.5 Micron
TV360Z HP Cmpr. Axial +/-0.305 +/-0.432 mm
RT370-4 HP Compressor OutBrd. Thrust 121.1 126.6 DegC
RT370-5 HP Compressor InBrd. Thrust 121.1 126.6 DegC
RT370-6 HP Compressor Suction Jrnl. Brg 115.6 121.1 DegC
RT370-7 HP Compressor Disch. Jrnl. Brg 115.6 121.1 DegC

TV351Y/X GP Brg1 63.5 101.6 Micron


TV352Y/X GP Brg2 63.5 101.6 Micron
TV353Y/X GP Brg3 63.5 101.6 Micron
TV351Z GP axial +0.102/-0.508 +0.178/-0.584 mm

TV354Y/X PT Brg4 63.5 101.6 Micron


TV355Y/X PT Brg5 63.5 101.6 Micron
TV355Z PT axial +0.102/-0.508 +0.178/-0.584 mm
TV3501 Accessory Gear ox 5.08 7.11 mm/sec rms

Seal
TAG DESCRIPTION ALARM S/D UNITS NOTE
RT370 HPC seal gas Temperature Low 29 DegC
TIT207 Seal Gas Htr. Outlet temp. Low 115 and RT370 < 40.5 82 and RT370 < 35 DegC
Seal Gas Htr. Outlet temp.High 130 135 DegC
TP385-1 HPC Disch. Primary Seal Vent 0.55 1.38 Barg
TP385-4 HPC Suc. Primary Seal Vent 0.55 1.38 Barg
TPD379-1 HPC Seal Filter DP 1.37 Delay 10 Sec - Bard
TPD372 HPC Buffer air Filter DP 2.06 - Bard
TPD383-1 HPC Buffer air DP Low 1.52 1.38 Bard
HPC Buffer air DP High 2.41 - Bard
TPD346-1 HPC seal as DP low 0.48 0.276 Bard
S391-1 HPC Secondary Seal Flow High 0.13 0.13 nm3/min Activate SD when start up and alarm only when running

Enclosure ,Fire & Gas


TAG DESCRIPTION ALARM S/D UNITS NOTE
S799A/B Air Inlet Filter DP 5 7 inH20
RT396 Enclosure Tempr. 75 85 DegC
TPD396-2 Enclosure Pressure 0.25 0.15 Delay 90 Sec inH20 If Fire system Inhibit only alarm
Any Two UV Flame detector Fire detect SD
Any One Gas Detector High 15 % LEL Start Permissive
Any One Gas Detector High High 40 % LEL Shut down with Enclosure fan running
Any One thermal heat detector high Trip Fire detect SD
UCP 24V Dc 24 Vdc Low 21.5 21 Vdc
25 Vdc High 32 Vdc
Process
TAG DESCRIPTION ALARM S/D UNITS NOTE
TP363-1 Compr. Suction Pr. 66.88 Low 63.43 Barg Shutdown by Pr. Sw. S363-1
TP364-1 Compr. Disch. Pr. 168.23 High 176.5 High Barg Shutdown by Pr. Sw. S364-1
RTD364-1 Compr. Disch. temp. 115.55 High not avail. Deg C
This list only contains alarm and shutdown list suitable for process operator to monitor and alert of GTGs
Check by: Dat-EI Date: 31March2023

LUBE
TAG DESCRIPTION ALARM S/D UNITS NOTE
RT327-2 Brg2/3 Drain Temp 121.1 High DegC
RT380 Lube Oil Header Temp 79.4 High DegC upto 60% NGP
68.3 High 73.9 High DegC Above 60% NGP
43.3 Low Above 60% NGP
S388_3 Lube Oil Tank Level 16.5 Low 11.4 Low cm
31.8 High - cm
TP380 Lube Oil Hdr. Pr. 1.72 High Barg Engine Stopped
0.41 Low 0.275 Low Barg Engine Running
4.48 High Barg Engine Running
S324_1 Lube Oil Tank Vent Pr. 8.5 High Inch H2O
TPD397 Lube Oil Filter 2.07 High Bard

Fuel
TAG DESCRIPTION ALARM S/D UNITS NOTE
TP344 Liquid Fuel Pump Check Fuel transfer 6.75 - Barg
TP386 Gas Fuel Pr. 10.3 Low Barg Low pressure alarm transfer to liquid by S586_1
12.4 High 12.7 High Barg
TP387 Liquid Fuel Pressure 0.4 0.3 Barg
S342-1 Gas Fuel Valve Check Fail - 0.69 Bard Gas Fuel valve check sequence fail
T5 T5 Temperature delayed SD 654.4 Delay 10 Sec 654.4 Delay 20 Sec DegC
T5 Temp. Inst. S/D - 685 DegC
Ngp Over Speed - 106 % 100 % Speed=21562rpm
Ngp Delay Overspeed - 104 % 10 sec delay
Ngp Under Speed - 90 % 60 Sec Delay Arm after Starter dropout
Ngp Back-Up Overspeed - 108 %
Ngp Failed to accelerate - <60 % 120 sec delay after ignition
ELF344 Liquid Fuel Valve Deviation 10 % 2 Sec Delay 10% difference between Cmd & FB
EGF388 Gas Fuel Valve Deviation 10 % 2 Sec Delay 10% difference between Cmd & FB
S389 Liquid Fuel Purge Tank Level High - mm

Temperature/Vibration Turbine/Generator
TAG DESCRIPTION ALARM S/D UNITS NOTE
RT371-1 Generator Brg Drive end DE 85 95 DegC
RT371-2 Generator Brg Non-Drive end EE 85 95 DegC
RT370A Generator Winding Phase A 120 130 DegC
RT370B Generator Winding Phase B 120 130 DegC
RT370C Generator Winding Phase C 120 130 DegC

TV358 X/Y Generator Brg DE 88.9 114.3 Micron


TV359 X/Y Generator Brg EE (NDE) 88.9 114.3 Micron

TV384-1 Engine Velocity 12.7 16.51 mm/sec


TV385-1 Gearbox Acceleration 35 40 g RMS

Enclosure ,Fire & Gas


TAG DESCRIPTION ALARM S/D UNITS NOTE
S799A/B Air Inlet Filter DP 5 7 inH20
RT396 Enclosure Tempr. 75 85 DegC
TPD396-2 Enclosure Pressure 0.25/0.15 0.15 Delay 90 Sec inH20 If Fire system Inhibit only alarm
Any One UV Flame detector Fire detect SD
Any One Gas Detector High 15 % LEL Start Permissive
Any Two Gas Detector High High 40 % LEL Shut down with Enclosure fan running
Any One thermal heat detector high Trip Fire detect SD
UCP 24V Dc 24 Vdc Low 21.5 21 Vdc
25 Vdc High 32 Vdc

Generator
TAG DESCRIPTION ALARM S/D UNITS NOTE
27 Under Voltage - 85 % of rated 10sec delay
59 Overvoltage - 115 % of rated 2sec delay
51 Over Current - 175 % of rated
81U Under Frequency - 48 Hz 20sec delay
81O Overfrequency - 52 Hz 20sec delay
32R Reverse power - 5 % of rated VA 10sec
40Q Reverse kVARs - 40 % of rated VA 5sec
59F Over Excitation voltage - 124.8 Volts 10 sec delay
40 Loss Of Excitation - 0.25 Amps 0.5 Sec Delay
87G Differential Gnd Fault - Set in Switchgear
Common trip Switchgear Malfunction - Common shutdown from Switch gear
47 Phase Rotation - ABC Normal phase rotation Direction of rotation
60FL Loss Of PT Sensing - PT Fuse Blown or PT damaged

Generator rated Synronization limits Dead bus closure limits