You are on page 1of 25

Technical Site Survey Report

STL Site ID HGSDR67


Operator Robi
Operator Site ID
Option A
Division Sylhet
District Habiganj
Union Teghoria
Mouza Shikerpur
Thana Habiganj Sadar

Site Address Noyakhal, ward-02,Shikondarpur-3300

Longitude 24.424968
Latitude 91.46295

TSS Date 25-May-23


Submission Date 27-May-23

Final Approval :
Name Signature Phone no
Radio Engineer
Transmission Engineer
Civil Engineer

Comments (If any):

Site Approval Accepted Rejected On Hold

Survey Participants:
Name Company Signature Phone no
Radio Representative
Transmission Representative
Civil Representative Humayun KRONE 01829703323
SAQ Representative Md. Jewel BATMO LTD 01755376474
House Owner Representative Polash Mia HO 01772531387
STL Representative

Note:
1. This Survey shouldn't take more than 2.5 hours to perform
2. Site approval box should be cheked before leaving the site.
3. If the site is rejected, the reason should be mentioned in the Comments section of the cover page.
4. All the items should be filled before leaving site as there is no optional item.
5. All signature should be collected from concern participants before leaving the site.

680205963.xlsx
General Information

STL Site Operator: Robi Operator Site ID:


ID: HGSDR67
Option: A Date:

1 Type of site Green Roof



Field Top
2 If GF site, proposed site on water body Yes ✘ No
3 Existing Ground Level (m) 0

4 Road Level (m) 2


2
5 Flood Level (m)

6 Distance from site to vehicle drop off point (m) 4400

7 Building height, m (if Roof Top) N/A

8 Site type ✘ Tower Pole


9 Frame height, m (if required) N/A

10 Height of Tower/ Pole (m) 3-Feb

11 Number of poles required N/A

12 Any dismantling works required for pole & ladder installation N/A

13 Type of Building Resident Commer Industria Others


ial cial l
14 Ownership type Two or Others
Single ✘
More
15 24 hours access available ✘ Yes No If no, explain

16 Any existing operator site on proposed building Yes ✘ No If yes, detail

17 Chain pulley is required for material lifting Yes ✘ No


18 Vehicle access up to site Yes ✘ No
18 Distance from main road to site (m)

19 Access road width (m)

20 Head-carrying required ✘ Yes No


21 Power authority ✘ REB DPDC DESCO
22 Phase ✘ Single Three
23 Distance from power meter to nearest power pole (1-phase/3-phase)

24 Distance from power meter to MDB

25 Substation available Yes ✘ No


26 Generator available Yes ✘ No
27 Space for Grounding Pit available (2 pit with 10 feet distance) ✘ Yes No
28 Owner agree for new power connection ✘ Yes No
29 Owner agree to lay any types of cable out side the house/ land ✘ Yes No
30 Power cable laying over other owner's house/ land Yes ✘ No
Total Available area, m x m
31 12x10
(length x width)
32 Proposed area, m x m (length x width) 10x10

Remarks:

680205963.xlsx
General Sketch

STL Operator: Robi Operator Site ID: 0


Site ID: HGSDR67
Option: A Date:
Site Layout Plan/ Rooftop Plan (hardcopy hand sketch)

680205963.xlsx
General Sketch

STL Operator: Robi Operator Site ID: 0


Site ID: HGSDR67
Option: A Date: 25-May-23
Building Information

1 Rebar grade 60 40 Others


2 Material used Brick Stone Others
chips chips
3 Construction year
4 Column rebar condition Extended
Flashed
5 Slab type Flat slab/
Beam slab plate
6 Slab thickness (mm)
7 Stair width (mm)

Roof entrance door


8
width (mm)

9 HO observation on column and beam size

10 Ground floor casting RCC CC

10 Structural drawing to as built matched Yes No Comments:


(If No then validate in comment)

Column and Rebar Details (hardcopy hand sketch)

680205963.xlsx
680205963.xlsx
STL Operator: Robi Operator Site ID:
Site ID: HGSDR67
Option: A Date:
Groundfloor Plan (hardcopy hand sketch)

680205963.xlsx
General Sketch
STL Operator: Robi Operator Site ID: 0
Site ID: HGSDR67
Option: A Date:
Elevation of Building (hardcopy hand sketch)

680205963.xlsx
STL Operator: Robi Operator Site ID:
Site ID: HGSDR67
Option: A Date:
Location Map (hardcopy hand sketch)

680205963.xlsx
Antenna Information

1. MW Antenna Information
Height Position (Tower
MW Dia Azimuth Remarks
(HBA) leg/Pole/WM)

2. GSM Antenna Information


New GSM Feeder/
Antenna length Position (Tower
information HBA Azimuth CPRI RRU nos.
& Number leg/Pole/WM)
Length
Sector-1
Sector-2
Sector-3

For Sharing site only:


Existing GSM Antenna length Position (Tower RRU
HBA Azimuth
information & Number leg/Pole/WM) nos.
Remarks
Sector-1
Sector-2
Sector-3 Survey Date

Sector-1 Sector-2 Sector-3


Side-arm required (Yes/No)
Number of req. side arm

Ladder Ladder Type Outdoor Ladder Indoor Ladder Other


Information Ladder Length

Other Observations:
Site Pictures-1
STL Operator: Operator Site ID:
Site ID:
Option: Date:
Front View of Proposed Site Building/ Site View (surround)

Building/ Site Main Road Site/Roof Access/Enterance

680205963.xlsx
680205963.xlsx
Site Pictures-2
STL Operator: Operator Site ID:
Site ID:
Option: Date:
Existing MDB/ Power Meter Location Proposed Power Meter Location

Nearest Power Pole Proposed Grounding PIT Location

680205963.xlsx
Site Pictures-3
STL Operator: Operator Site ID:
Site ID:
Option: Date:
proposed space View-Front proposed space View-Rear

proposed space View-Right proposed space View-Left

680205963.xlsx
680205963.xlsx
Site Pictures-4
STL Operator: Operator Site ID:
Site ID:
Option: Date:
Ground Floor Beam View 1'st Floor Beam View

2'nd Floor Beam View 3'rd Floor Beam View

4'th Floor Beam View 5'th Floor Beam View

6'th Floor Beam View 7'th Floor Beam View

680205963.xlsx
680205963.xlsx
Site Pictures-5
STL Operator: Operator Site ID:
Site ID:
Option: Date:
Access road View-1 Access road View-2

Location sketch (Google Maps screenshot with


Additional Picture
Longitude-Latitude/ GPS Picture)

680205963.xlsx
Azimuth view-1
STL Operator: Robi Operator Site ID: 0
Site ID: HGSDR67
Option: A Date: 25-May-23
Azimuth 0° Azimuth 30°

Azimuth 60° Azimuth 90°

680205963.xlsx
680205963.xlsx
Azimuth view-2
STL Operator: Robi Operator Site ID: 0
Site ID: HGSDR67
Option: A Date: 25-May-23
Azimuth 120° Azimuth 150°

Azimuth 180° Azimuth 210°

680205963.xlsx
680205963.xlsx
Azimuth view-3

Option: A Date: 25-May-23


Azimuth 240° Azimuth 270°

Azimuth 300° Azimuth 330°

680205963.xlsx
Existing Room Survey (For Sharing site only)

Equipment Room Investigation Actual Remarks

BTS Room Size (L*W) (m):

Security Guard Room Available? Yes No


Generator Room Available? Yes No
Generator room Type Brick/ Grill

Power & Battery Backup Actual Remarks


Power Connection Type Commercial/ Generator/ Solar/ Other
Power Phase: Single Phase / 3-Phase
Active MCCB Qty:
Active MDB Qty:
Idle MDB Qty:

Cable Inlet (roxtec) & Route


Actual Remarks
(ladder)
No. of Existing Roxtec/Feeder Hole:
Total holes available at Roxtec/Feeder
Hole:
No.of free holes available at
Roxtec/Feeder Hole:
New Roxtec/Feeder Hole Required?

Outdoor Investigation Actual Remarks


Site Type
(GF/GFRT/RT/RTP/CoW/Monopole)
Building Height (m)
Tower / Pole Height (m)
No. of Pole
Tower Painting Condition
Qty of Aviation Light
Aviation Light Type
Lightning Arrestor Available on Top of
Tower?
Access Road availability (in case of
existing site)
New access road required (in case of
new BTS location)
HFL
Height from EGL/FGL to existing BTS
floor level

Outdoor Grounding Actual Remarks


Existing Tower Already Grounded?
Existing Poles are grounded?
Grounding point available for
RRU/TMF?
EM survey scope (For Sharing Site Only)

1. Equipment Room Investigation Actual Remarks

No. of Active Airconditioning unit:


No. of Idle Airconditioning unit:
Airconditioning Unit Type:
No. of Active IVS/FCU unit:
No. of Idle IVS/FCU unit:

Voltage Stabilizer Brand:


Voltage Stabilizer Capacity:
Active Voltage Stabilizer Qty:
Idle Voltage Stabilizer Qty:
Alarm System/Automatic Monitoring System (AMS)
Brand:

MDB Circuit Breaker Details: Actual Remarks


Existing 3P CB ratings & Qty:
Existing 1P CB ratings & Qty:
Free 3P CB ratings & Qty:
Free 1P CB ratings & Qty:
Rectifier CB rating:
Lighting CB rating:
Free space in MDB
(in terms of 1P CB):

DCDB Details: Actual Remarks


DCDB QTY:
No. & Capacity of used CB in DCDB
No.& Capacity of Free CB in DCDB:

Existing Rectifier Cabinet Information: Actual Remarks


Brand:
Cabinet Qty:
Output Voltage:
Idle Rectifier Cabinet Qty:
Rectifier Module Qty:
Rectifier Module Capacity (watt):
Idle Rectifier Module Qty:
Total DC load (watt):
No. & Capacity of used CB in Rectifier
No. & Capacity of free CB in Rectifier

Existing Battery Bank Information: Actual Remarks


Brand:
No. of Battery Bank:
No. of cell in each Bank:
Total Cell Qty:
Cell Ampere Hour (AH) Capacity:
Volt / Bank:
Volt / Cell:
Remarks:
Tenant1 Operator Name
(applicable for room sharing):
Cabinet Qty:
Equipment Vendor:
Model & Qty:

Tenant2 Operator Name


(applicable for room sharing):
Cabinet Qty:
Equipment Vendor:
Model & Qty:

Indoor Grounding Actual Remarks


AC Bas Bar available inside equipment room?
DC Bas Bar available inside equipment room?
Bas Bar properly Grounded?
No. of free position on AC Bas Bar
No. of free position on DC Bas Bar
Remarks:

Site dependent Material data


Types of Materials Required Actual Remarks
AC Power Cable
(Other Operator MDB to Proposed MDB)
DC Power Cable
(Rectifier to Battery Bank)
DC Power Cable
(Other Operator Rectifier to Proposed DCDB)
Grounding Cable
(Proposed DCDB/MDB to Bas Bar)
Grounding Cable
(Tx Rack, BTS Cabinet to Bas Bar)
Indoor Cable Ladder requirements
Outdoor Cable Ladder requirements
Antenna mounting side arm
MW mounting side arm

You might also like